DATA SHEET Part Number: SL12 15004 Ordering Different Lead Types: Inside Kinked Leads Outside Kinked Leads Use -A after Ametherm's part # Use -B after Ametherm's part # For example: to order an inside kinked lead use part number SL12 15004-A D D D T C B L S S S STRAIGHT LEADS OUTSIDE KINKED LEADS INSIDE KINKED LEADS Electrical Specifications: Mechanical Specifications: Resistance @ 25C Max Steady State Current Up to 65C Max Recommended Energy Rating (Joules) Actual Failure Point of Instantaneous Energy (Joules) Resistance @ 100% of Max Current Resistance @ 50% of Max Current Body Temperature @ 100% Current Rating Dissipation Constant Thermal Time Constant Material Type Max Recommended Capacitance @ 120VAC/240VAC 15.0 15% 4.0 A 40.0 J 105.0 J 0.160 0.338 152 C 13.9mW/C 54 seconds "C' 2700F/690F CSA File Number: #CA118061 D T Lead Diameter S L Straight Leads Coating Run Down B C 12.0 0.5 mm 5.5 0.5 mm 0.80 0.1 mm 7.8 2.0 mm 20.0 1.5 mm See Dimension B below 5.10 mm Max 2.82 0.5 mm Revision Date: March 19, 2003 Ametherm, Inc. 3111 N. Deer Run Road #4 Carson City, NV 89701 Telephone: (800) 808-2434 (775) 884-2434 Fax: (775) 884-0670 www.ametherm.com