Detailed Specifications & Technical Data METRIC MEASUREMENT VERSION 9451 Multi-Conductor - Single-Pair Cables For more Information please call 1-800-Belden1 General Description: 22 AWG stranded (7x30) TC conductors, polypropylene insulation, twisted pair, overall Beldfoil shield (100% coverage), 22 AWG stranded TC drain wire, PVC jacket. Physical Characteristics (Overall) Conductor AWG: # Pairs AWG Stranding Conductor Material 1 22 7x30 TC - Tinned Copper Total Number of Conductors: 2 Insulation Insulation Material: Insulation Material Wall Thickness (mm) PP - Polypropylene 0.2032 Outer Shield Outer Shield Material: Outer Shield Trade Name Type Outer Shield Material Beldfoil(R) Coverage (%) Tape Aluminum Foil-Polyester Tape 100 Outer Shield Drain Wire AWG: AWG Stranding Drain Wire Conductor Material 22 7x30 TC - Tinned Copper Outer Jacket Outer Jacket Material: Outer Jacket Material Nom. Wall Thickness (mm) PVC - Polyvinyl Chloride 0.508 Overall Cable Overall Nominal Diameter: 3.429 mm Pair Pair Color Code Chart: Number Color 1 Black & Red Mechanical Characteristics (Overall) Operating Temperature Range: -20C To +75C UL Temperature Rating: 60C Bulk Cable Weight: 20.835 Kg/Km Max. Recommended Pulling Tension: 120.101 N Min. Bend Radius/Minor Axis: 38.100 mm Applicable Specifications and Agency Compliance (Overall) Applicable Standards & Environmental Programs NEC/(UL) Specification: CMR Page 1 of 3 10-30-2013 Detailed Specifications & Technical Data METRIC MEASUREMENT VERSION 9451 Multi-Conductor - Single-Pair Cables CEC/C(UL) Specification: CMG EU Directive 2011/65/EU (ROHS II): Yes EU CE Mark: Yes EU Directive 2000/53/EC (ELV): Yes EU Directive 2002/95/EC (RoHS): Yes EU RoHS Compliance Date (mm/dd/yyyy): 01/01/2004 EU Directive 2002/96/EC (WEEE): Yes EU Directive 2003/11/EC (BFR): Yes CA Prop 65 (CJ for Wire & Cable): Yes MII Order #39 (China RoHS): Yes Flame Test UL Flame Test: UL1666 Vertical Shaft CSA Flame Test: FT4 Plenum/Non-Plenum Plenum (Y/N): No Electrical Characteristics (Overall) Nom. Characteristic Impedance: Impedance (Ohm) 45 Nom. Inductance: Inductance (H/m) 0.55777 Nom. Capacitance Conductor to Conductor: Capacitance (pF/m) 114.835 Nom. Capacitance Cond. to Other Conductor & Shield: Capacitance (pF/m) 219.827 Nominal Velocity of Propagation: VP (%) 66 Nominal Delay: Delay (ns/m) 4.9215 Nom. Conductor DC Resistance: DCR @ 20C (Ohm/km) 46.2621 Nominal Outer Shield DC Resistance: DCR @ 20C (Ohm/km) 46.9183 Max. Operating Voltage - UL: Voltage 300 V RMS Max. Recommended Current: Current 2.9 Amps per conductor @ 25C Notes (Overall) Notes: The jacket and shield are bonded so both can be removed on automatic stripping equipment. Drain wire is inside foil shield. Page 2 of 3 10-30-2013 Detailed Specifications & Technical Data METRIC MEASUREMENT VERSION 9451 Multi-Conductor - Single-Pair Cables Notes: The jacket and shield are bonded so both can be removed on automatic stripping equipment. Drain wire is inside foil shield. For cross-connect use with 1814R (et. al.) Snake Cables. Put Ups and Colors: Item # Putup Ship Weight Color 9451 N3UU1000 305 MT 7.258 KG GREEN, MIL Notes Item Desc 9451 N3U5000 1,524 MT 31.752 KG GREEN, MIL 9451 001U1000 305 MT 7.258 KG BROWN 9451 0015000 1,524 MT 31.752 KG BROWN 9451 002U1000 305 MT 7.258 KG RED 9451 0025000 1,524 MT 34.020 KG RED 9451 003U1000 305 MT 7.258 KG ORANGE 9451 0035000 1,524 MT 34.020 KG ORANGE 9451 004U1000 305 MT 7.258 KG YELLOW 9451 0045000 1,524 MT 34.020 KG YELLOW 9451 006U1000 305 MT 7.258 KG BLUE, LIGHT 9451 0065000 1,524 MT 34.020 KG BLUE, LIGHT 9451 007U1000 305 MT 7.258 KG VIOLET 9451 0075000 1,524 MT 34.020 KG VIOLET 9451 008T1000 305 MT 7.258 KG GRAY 2 #22 PP FS PVC FR 9451 008U1000 305 MT 7.258 KG GRAY 2 #22 PP FS PVC FR 9451 008U500 152 MT 3.856 KG GRAY 2 #22 PP FS PVC FR 9451 008500 152 MT 3.629 KG GRAY 9451 0085000 1,524 MT 34.020 KG GRAY 9451 009U1000 305 MT 7.258 KG WHITE 9451 0095000 1,524 MT 34.020 KG WHITE 9451 010U1000 305 MT 7.258 KG BLACK 9451 0101000 305 MT 7.258 KG BLACK 9451 0105000 1,524 MT 34.020 KG BLACK 2 #22 PP FS PVC FR CN 2 #22 PP FS PVC FR 2 #22 PP FS PVC FR CN 2 #22 PP FS PVC FR 2 #22 PP FS PVC FR CN 2 #22 PP FS PVC FR 2 #22 PP FS PVC FR CN 2 #22 PP FS PVC FR 2 #22 PP FS PVC FR CN 2 #22 PP FS PVC FR 2 #22 PP FS PVC FR CN 2 #22 PP FS PVC FR 2 #22 PP FS PVC FR CN 2 #22 PP FS PVC FR 2 #22 PP FS PVC FR CN 2 #22 PP FS PVC FR 2 #22 PP FS PVC FR CN 2 #22 PP FS PVC FR 2 #22 PP FS PVC FR 2 #22 PP FS PVC FR CN 2 #22 PP FS PVC FR Notes: C = CRATE REEL PUT-UP. N = FINAL PUT-UP LENGTH MAY VARY -0% TO +10% FROM LENGTH SHOWN. Revision Number: 1 Revision Date: 08-08-2012 (c) 2013 Belden, Inc All Rights Reserved. Although Belden makes every reasonable effort to ensure their accuracy at the time of this publication, information and specifications described herein are subject to error or omission and to change without notice, and the listing of such information and specifications does not ensure product availability. Belden provides the information and specifications herein on an "AS IS" basis, with no representations or warranties, whether express, statutory or implied. In no event will Belden be liable for any damages (including consequential, indirect, incidental, special, punitive, or exemplary damages) whatsoever, even if Belden has been advised of the possibility of such damages, whether in an action under contract, negligence or any other theory, arising out of or in connection with the use, or inability to use, the information or specifications described herein. All sales of Belden products are subject to Belden's standard terms and conditions of sale. Belden believes this product to be in compliance with EU RoHS (Directive 2002/95/EC, 27-Jan-2003). Material manufactured prior to the compliance date may be in stock at Belden facilities and in our Distributor's inventory. The information provided in this Product Disclosure, and the identification of materials listed as reportable or restricted within the Product Disclosure, is correct to the best of Belden's knowledge, information, and belief at the date of its publication. The information provided in this Product Disclosure is designed only as a general guide for the safe handling, storage, and any other operation of the product itself or the one that it becomes a part of. This Product Disclosure is not to be considered a warranty or quality specification. Regulatory information is for guidance purposes only. Product users are responsible for determining the applicability of legislation and regulations based on their individual usage of the product. Belden declares this product to be in compliance with EU LVD (Low Voltage Directive 73/23/EEC), as amended by directive 93/68/EEC. Page 3 of 3 10-30-2013