2. UL Approved Equipment UL was established in 1894 by William Henry Merrill for the testing of products' safety against fire and other dangers related to electricity for the purposes of U.S. insurance companies. The institute has since been testing materials, apparatuses, products, equipment, buildings, systems, etc., concerning the danger to life and property under the auspices of American Insurance Association. It is not directly related with the association but is a completely independent non-profit-making organization, which is known as the world-oldest and greatest authority for safety testing. To ensure the safety of life and property against fire, electric shock or other dangers which may arise in using equipment, UL assumes the following missions from the consumers' point of view: Table 1 Indication of UL approval Indication of UL approval (1) To establish safety standards (2) To test products based on those established standards (3) To make the test results known to insurers, government agencies, related organizations and general consumers Listing Publication method Indication on Publication by UL product Listing mark Categorized White card products list (Green Book) Recognition Recognition mark Registered Yellow card parts list (Yellow Book) UL executes tests for above purposes, approves the products which clear applicable standards, and makes them known to the public. There are two methods for indicating UL approval: (1) Listing service This is generally referred to as "listing" and is applied to the products and parts which are manufactured so as to ensure safety under any working conditions. Considering that they are used by general consumers, comprehensive investigation and testing are made as to their safety. When accepted, they are given the "listing mark" and made known to the public by means of the categorized products list (Green Book) which is published by UL. Table 2 Indication of ULCSA approval Indication of Indication on ULCSA approval product Listing Listing mark Recognition (2) Recognition service This is applied mainly to the materials or parts which are assembled in final products in manufacturers' factories. When accepted, they are included in the registered parts list (Yellow Book). Outline - Listing for USA and Canada UL and CSA certification by testing organization UL Recognition mark - Listing for USA and Canada - UL and CSA certification by testing organization UL Contactors and Starters z Standard magnetic contactors and starters (non-reversing, open type) Series Magnetic Standard contactors Type Magnetic starters Continuous Auxiliary contact current [A] arrangement Max. motor capacity [HP] Type NEW SC Series SC-03, 03Y SC-0, 0Y SC-05, 05Y SC-4-0 SC-4-1 SC-5-1, 5-1Y Single-phase 110220120V 240V SW-03/3H, 03Y/3H 1/3 1 SW-0/3H, 0Y/3H 1/3 1 SW-05/3H, 05Y/3H 1/3 1 SW-4-0/3H 1 2 SW-4-1/3H 1 2 SW-5-1/3H, 5-1Y/3H 1 2 NEO SC Series SC-N1 SC-N2 SC-N2S SC-N3 SC-N4 SC-N5 SC-N6 SC-N7 SC-N8 SC-N10 SC-N11 SC-N12 SC-N14 SC-N16 SW-N1/3H SW-N2/3H SW-N2S/3H SW-N3/3H SW-N4/3H SW-N5/3H SW-N6/3H SW-N7/3H SW-N8/3H SW-N10/3H SW-N11/3H SW-N12/3H SW-N14/3H - 2 3 3 5 7 1/2 7 1/2 10 15 - 5 7 1/2 10 15 15 15 20 25 - 3-phase squirrel-cage 200V 220- 400- 550240V 480V 600V 2 2 5 5 3 3 5 5 3 3 5 5 5 5 7 1/2 7 1/2 5 5 10 10 5 5 10 10 11 13 13 20 20 20 7 1/2 10 15 20 25 30 40 50 60 75 100 125 200 250 50 60 80 100 135 150 150 200 260 260 350 450 660 800 Note 1: Contactor ratings refer to the continuous current value. 11 10 15 20 25 30 30 40 50 60 75 100 150 200 300 25 30 40 50 60 60 75 100 150 150 200 300 500 600 25 30 40 50 60 75 100 125 150 200 250 350 600 700 UL File No. Standard On request 1NO 1NO 1NO+1NC 1NO 1NO 1NO+1NC 2NO+2NC 2NO+2NC 2NO+2NC 2NO+2NC 2NO+2NC 2NO+2NC 2NO+2NC 2NO+2NC 2NO+2NC 2NO+2NC 2NO+2NC 2NO+2NC 2NO+2NC 2NO+2NC E42419 1NC 1NC 2NO, 2NC 1NC 1NC 2NO, 2NC 2NO+2NC 4NO+4NC 4NO+4NC 4NO+4NC 4NO+4NC 4NO+4NC 4NO+4NC 4NO+4NC 4NO+4NC 4NO+4NC 4NO+4NC 4NO+4NC 4NO+4NC 4NO+4NC 4NO+4NC zReversing standard contactors and starters (reversing open type) Series Standard NEW SC Series NEO SC Series Magnetic contactors Type Magnetic starters Max. motor capacity [HP] Type SC-03RM SC-0RM SC-05RM SC-4-0RM SC-4-1RM SC-5-1RM SC-N1RM SC-N2RM SC-N2SRM SC-N3RM SC-N4RM SC-N5RM SC-N6RM SC-N7RM SC-N8RM SC-N10RM SC-N11RM SC-N12RM SC-N14RM SW-03RM/3H SW-0RM/3H SW-05RM/3H SW-4-0RM/3H SW-4-1RM/3H SW-5-1RM/3H SW-N1RM/3H SW-N2RM/3H SW-N2SRM/3H SW-N3RM/3H SW-N4RM/3H SW-N5RM/3H SW-N6RM/3H SW-N7RM/3H SW-N8RM/3H SW-N10RM/3H SW-N11RM/3H SW-N12RM/3H SW-N14RM/3H 3-phase squirrel-cage 200V 220-240V 2 2 3 3 3 3 5 5 5 5 5 5 7 1/2 10 10 15 15 20 20 25 25 30 30 30 40 40 50 50 60 60 75 75 100 100 125 150 200 200 440-480V 5 5 5 7 1/2 10 10 25 30 40 50 60 60 75 100 150 150 200 300 500 550-600V 5 5 5 7 1/2 10 10 25 30 40 50 60 75 100 125 150 200 250 350 600 Continuous current [A] UL File No. 11 13 13 20 20 20 50 60 80 100 135 150 150 200 260 260 350 450 660 E42419 Notes 1: Contactor ratings refer to the continuous current value. 2: To use type -03 to -N3 "reversing" magnetic contactors or starters as UL or CSA approved equipment, it is necessary to replace the operation circuit wires with UL or CSA approved ones. z DC operated magnetic contactors and starters (non-reversing, open type) Series Standard NEW SC Series NEO SC Series Magnetic contactors Type Magnetic starters Max. motor capacity [HP] Type Single-phase 110220120V 240V SC-03/G, 03Y/G SW-03/G3H, 03Y/G3H 1/3 1 SC-0/G, 0Y/G SW-0/G3H, 0Y/G3H 1/3 1 SC-05/G, 05Y/G SW-05/G3H, 05Y/G3H 1/3 1 SC-4-0/G SW-4-0/G3H 1 2 SC-4-1/G SW-4-1/G3H 1 2 SC-5-1/G, 5-1Y/G SW-5-1/G3H, 5-1Y/G3H 1 2 SC-N1/G SW-N1/G3H 2 5 SC-N2/G SW-N2/G3H 3 7 1/2 SC-N2S/G SW-N2S/G3H 3 10 SC-N3/G SW-N3/G3H 5 15 SC-N1/SE SW-N1/SE3H 2 5 SC-N2/SE SW-N2/SE3H 3 7 1/2 SC-N2S/SE SW-N2S/SE3H 3 10 SC-N3/SE SW-N3/SE3H 5 15 SC-N4/SE SW-N4/SE3H 7 1/2 15 SC-N5 SW-N5/3H 7 1/2 15 SC-N6 SW-N6/3H 10 20 SC-N7 SW-N7/3H 15 25 SC-N8 SW-N8/3H SC-N10 SW-N10/3H SC-N11 SW-N11/3H SC-N12 SW-N12/3H SC-N14 SW-N14/3H SC-N16 - Note 1: Contactor ratings refer to the continuous current value. 12 3-phase squirrel-cage 200V 220440240V 480V 2 2 5 3 3 5 3 3 5 5 5 7 1/2 5 5 10 5 5 10 7 1/2 10 25 10 15 30 15 20 40 20 25 50 7 1/2 10 25 10 15 30 15 20 40 20 25 50 25 30 60 30 30 60 40 40 75 50 50 100 60 60 150 75 75 150 100 100 200 125 150 300 200 200 500 250 300 600 550600V 5 5 5 7 1/2 10 10 25 30 40 50 25 30 40 50 60 75 100 125 150 200 250 350 600 700 Continuous current [A] UL File No. 11 13 13 20 20 20 50 60 80 100 50 60 80 100 135 150 150 200 260 260 350 450 660 800 E42419 z Magnetic starters with 2E thermal overload relay (open type) Series Standard NEW SC Series NEO SC Series *1 Non reversing Type Reversing Type DC operated (non reversing) Max. motor capacity [HP] Type 3-phase squirrel-cage 200V 220- 440- 550240V 480V 600V SW-03/2E, 03Y/2E SW-03RM/2E SW-03/G2E,03Y/G2E 2 2 5 5 SW-0/2E, 0Y/2E SW-0RM/2E SW-0/G2E, 0Y/G2E 3 3 5 5 SW05/2E, 05Y/2E SW-05RM/2E SW-05/G2E, 05Y/G2E 3 3 5 5 SW-4-0/2E SW-4-0RM/2E SW-4-0/G2E 5 5 7 1/2 7 1/2 SW-4-1/2E SW-4-1RM/2E SW-4-1/G2E 5 5 10 10 SW-5-1/2E, 5-1Y/2E SW-5-1RM/2E SW-5-1/G2E, 5-1Y/G2E 5 5 10 10 SW-N1/2E SW-N1RM/2E SW-N1/G2E, SW-N1/SE2E 7 1/2 10 25 25 SW-N2/2E SW-N2RM/2E SW-N2/G2E, SW-N2/SE2E 10 15 30 30 SW-N2S/2E SW-N2SRM/2E SW-N2S/G2E, SW-N2S/SE2E 15 20 40 40 SW-N3/2E SW-N3RM/2E SW-N3/G2E, SW-N3/SE2E 20 25 50 50 SW-N4/2E SW-N4RM/2E SW-N4SE/2E 25 30 60 60 SW-N5/2E SW-N5RM/2E SW-N5/2E 30 30 60 75 SW-N6/2E SW-N6RM/2E SW-N6/2E 40 40 75 100 SW-N7/2E SW-N7RM/2E SW-N7/2E 50 50 100 125 SW-N8/2E SW-N8RM/2E SW-N8/2E 60 60 150 150 SW-N10/2E SW-N10RM/2E SW-N10/2E 75 75 150 200 SW-N11/2E SW-N11RM/2E SW-N11/2E 100 100 200 250 SW-N12/2E SW-N12RM/2E SW-N12/2E 125 150 300 350 SW-N14/2E SW-N14RM/2E SW-N14/2E 200 200 500 600 Continuous UL File No. current [A] 11 13 13 20 20 20 50 60 80 100 135 150 150 200 260 260 350 450 660 E42419 Notes 1: Contactor ratings refer to the continuous current value. 2: To use type -03 to -N3 "reversing" magnetic contactors or starters as UL or CSA approved equipment, it is necessary to replace the operation circuit wires with UL or CSA approved ones. *1 Max. motor capacity for single-phase motors is the same as that for standard magnetic starters. 13 z Standard auxiliary relays Series Type Standard Poles Contact arrangement NEW SC Series 4 SH-4, SH-4Y 8 SH-5 *1 4NO, 3NO+1NC, 2NO+2NC *1 5 4NO, 3NO+1NC, 2NO+2NC, 5NO+3NC, 4NO+4NC Continuous Operational current [A] current [A] AC Volts [V] Make Break 10 120 60 6 240 30 3 480 15 1.5 600 12 1.2 10 120 60 6 5NO, 10 4NO+1NC, 3NO+2NC, 2NO+3NC, 1NO+4NC, 5NC 240 480 30 15 3 1.5 600 12 1.2 120 240 480 60 30 15 6 3 1.5 600 12 1.2 Code DC AC DC Volts [V] Make Break 125 0.55 0.55 A600 Q300 250 0.27 0.27 125 0.55 0.55 250 0.27 0.27 125 0.55 0.55 250 0.27 0.27 A600 Q300 A600 Q300 UL File No. E44592 8-contact products of SH-4(Y) type are a combination of SH-4(Y) (4 contacts) and auxiliary contact block SZ-A(Y) (Front mounting, 4 contacts). z DC operated auxiliary relays Series Type Standard NEW SC Series Poles Contact arrangement SH-4/G, 4 SH-4Y/G 8 SH-5/G *1 5 4NO, 3NO+1NC, 2NO+2NC *1 8NO, 7NO+1NC, 6NO+2NC, 5NO+3NC, 4NO+4NC Continuous Operational current [A] current [A] AC Volts [V] Make Break 10 120 60 6 240 30 3 480 15 1.5 600 12 1.2 10 120 60 6 5NO, 10 4NO+1NC, 3NO+2NC, 2NO+3NC, 1NO+4NC, 5NC 240 480 30 15 3 1.5 600 12 1.2 120 240 480 60 30 15 6 3 1.5 600 12 1.2 Code DC AC DC Volts [V] Make Break 125 0.55 0.55 A600 Q300 250 0.27 0.27 125 0.55 0.55 250 0.27 0.27 125 0.55 0.55 250 0.27 0.27 A600 Q300 A600 Q300 UL File No. E44592 8-contact products of SH-4(Y)/G type are a combination of SH-4(Y)/G (4 contacts) and auxiliary contact block SZ-A(Y) (Front mounting, 4 contacts). 14 z Standard application of built-in thermal overload relays of magnetic contactors (protection coordination with over current relay) Type of magnetic contactor Type of built-in thermal overload relay SW-03/3H, 03Y/3H Heat element ratings of built-in thermal overload relay [A] 0.1 - 0.15 0.13 - 0.2 0.15 - 0.24 0.2 - 0.3 0.24 - 0.36 0.3 - 0.45 0.36 - 0.54 0.48 - 0.72 0.64 - 0.96 0.8 - 1.2 0.95 - 1.45 1.4 - 2.2 1.7 - 2.6 2.2 - 3.4 2.8 - 4.2 4-6 5-8 TR-0N/3, 0NY/3 SW-0/3H, SW-05/3H, 0Y/3H SW-4-0/3H SW-4-1/3H SW-5-1/3H, SW-N1/3H SW-N2/3H SW-N2S/3H SW-N3/3H 0Y/3H 5-1Y/3H TR-5-1N/3, 5-1NY/3 TR-2N/3 TR-3N/3 0.1 - 0.15 0.13 - 0.2 0.15 - 0.24 0.2 - 0.3 0.24 - 0.36 0.3 - 0.45 0.36 - 0.54 0.48 - 0.72 0.64 - 0.96 0.8 - 1.2 0.95 - 1.45 1.4 - 2.2 1.7 - 2.6 2.2 - 3.4 2.8 - 4.2 4-6 5-8 6-9 7 - 11 0.1 - 0.15 0.13 - 0.2 0.15 - 0.24 0.2 - 0.3 0.24 - 0.36 0.3 - 0.45 0.36 - 0.54 0.48 - 0.72 0.64 - 0.96 0.8 - 1.2 0.95 - 1.45 1.4 - 2.2 1.7 - 2.6 2.2 - 3.4 2.8 - 4.2 4-6 5-8 6-9 7 - 11 9 - 13 12 - 18 4-6 5-8 6-9 7 - 11 9 - 13 12 - 18 18 - 26 24 - 36 4-6 5-8 6-9 7 - 11 9 - 13 12 - 18 18 - 26 24 - 36 7 - 11 9 - 13 12 - 18 18 - 26 24 - 36 28 - 40 7 - 11 9 - 13 12 - 18 18 - 26 24 - 36 28 - 40 34 - 50 45 - 65 34 - 50 45 - 65 48 - 68 32 - 42 *1 *2 Use UL or CSA approved fuses. However, the current values for current limiting fuses are when time-delay fuses (rated current of heat element of thermal overload relay: max. 2.8 to 4.2A) or instantaneous fuses (rated current of heat element of thermal overload relay: min. 4 to 6A) is used. Figures in [ ] are the rating of CSA approved fuses. Use UL or CSA approved molded case circuit breakers. However, the working voltage is 480V or less when combined with SW-03(Y)/3H to -05(Y)/3H types; 600V or less when combined with SW-4-0/3H or greater starters. 15 SWN4/3H TR4N/UL SWSWN5/3H N6/3H TR-6N/UL SWN7/3H SWN8/3H TR8N/UL SWN10/3H TR10N/UL SWN11/3H TR11N/UL SWN12/3H TR12N/UL 18 - 26 18 - 26 24 - 36 24 - 36 28 - 40 28 - 40 34 - 50 34 - 50 45 - 65 45 - 65 53 - 80 53 - 80 65 - 95 85 - 105 45 - 65 53 - 80 65 - 95 85 - 125 45 - 65 53 - 80 65 - 95 85 - 125 110 - 160 65 - 95 85 - 125 110 - 160 125 - 185 85 - 125 110 - 160 110 - 160 125 - 185 125 - 185 160 - 240 160 - 240 200 - 300 110 - 160 125 - 185 160 - 240 200 - 300 240 - 360 300 - 450 16 SWN14/3H TR-N14/3 max *1 Current limiting fuses Operational current [A] 1 [15] 1 [15] 1 [15] 1 [15] 2 [15] 2 [15] 3 [15] 3 [15] 3 [15] 5 [15] 5 [15] 10 [15] 10 [15] 15 15 15 20 30 30 30 50 20 20 20 20 20 50 50 50 70 70 70 125 125 150 150 150 150 150 150 150 200 225 225 225 225 300 300 300 300 450 450 450 240 - 360 800 300 - 450 800 400 - 600 800 max *2 Molded case circuit breaker Operational UL approved FUJI current [A] auto breaker types 15 15 15 15 15 15 15 15 15 15 15 15 15 15 15 15 15 15 15 20 40 60 60 60 60 60 60 60 60 70 70 70 125 125 125 125 125 175 175 175 175 225 400 400 400 400 400 400 400 400 600 600 600 800 800 800 BU-3EHC BU-3EHC BU-3EHC BU-3EHC BU-3EHC BU-3EHC BU-3EHC BU-3EHC BU-3EHC BU-3EHC BU-3EHC BU-3EHC BU-3EHC BU-3EHC BU-3EHC BU-3EHC BU-3EHC BU-3EHC BU-3EHC BU-3EHC BU-ESB BU-ESB BU-ESB BU-ESB BU-ESB BU-ESB BU-ESB BU-ESB BU-ESB BU-ESB BU-ESB BU-ESB BU-FSB BU-FSB BU-FSB BU-FSB BU-FSB BU-JSB BU-JSB BU-JSB BU-JSB BU-JSB BU-KSB BU-KSB BU-KSB BU-KSB BU-KSB BU-KSB BU-KSB BU-KSB BU-LSB BU-LSB BU-LSB BU-MSB BU-MSB BU-MSB z Standard thermal overload relays (with 3 heat elements), 2E thermal overload relays Series Type NEW SC TR-0N/3, TR-0NY/3 *4 Series TK-0N *4 TK-0NY TR-5-1N/3 TR-5-1NY/3 *4 TR-5-1N *4 TK-5-1NY NEO SC TR-N2/3 *4 Series [TK-N2] *4 No. of Reset heat elements 3 3 3 Auxiliary contact Heat element 1 rating [A] * Manual/Auto 1NO+1NC 0.1 - 0.15 (0.1) 0.13 - 0.2 (0.13) 0.15 - 0.24 (0.15) 0.2 - 0.3 (0.2) 0.24 - 0.36 (0.24) 0.3 - 0.45 (0.3) 0.36 - 0.54 (0.36) 0.48 - 0.72 (0.48) 0.64 - 0.96 (0.64) 0.8 - 1.2 (0.8) 0.95 - 1.45 (0.95) 1.4 - 2.2 (1.4) 1.7 - 2.6 (1.7) 2.2 - 3.4 (2.2) 2.8 - 4.2 (2.8) 4 - 6 (4) 5 - 8 (5) 0.1 - 0.15 (0.1) 0.13 - 0.2 (0.13) 0.15 - 0.24 (0.15) 0.2 - 0.3 (0.2) 0.24 - 0.36 (0.24) 0.3 - 0.45 (0.3) 0.36 - 0.54 (0.36) 0.48 - 0.72 (0.48) 0.64 - 0.96 (0.64) 0.8 - 1.2 (0.8) 0.95 - 1.45 (0.95) 1.4 - 2.2 (1.4) 1.7 - 2.6 (1.7) 2.2 - 3.4 (2.2) 2.8 - 4.2 (2.8) 4 - 6 (4) 5 - 8 (5) 6 - 9 (6) 7 - 11 (7) Manual/Auto 1NO+1NC 0.1 - 0.15 (0.1) 0.13 - 0.2 (0.13) 0.15 - 0.24 (0.15) 0.2 - 0.3 (0.2) 0.24 - 0.36 (0.24) 0.3 - 0.45 (0.3) 0.36 - 0.54 (0.36) 0.48 - 0.72 (0.48) 0.64 - 0.96 (0.64) 0.8 - 1.2 (0.8) 0.95 - 1.45 (0.95) 1.4 - 2.2 (1.4) 1.7 - 2.6 (1.7) 2.2 - 3.4 (2.2) 2.8 - 4.2 (2.8) 4 - 6 (4) 5 - 8 (5) 6 - 9 (6) 7 - 11 (7) 9 - 13 (9) 12 - 18 (12) Manual 1NO+1NC 4 - 6 (4) 5 - 8 (5) 6 - 9 (6) 7 - 11 (7) 9 - 13 (9) 12 - 18 (12) 18 - 26 (18) 24 - 36 (24) 17 Protection coordination Max. rated Max. rated current of current of current molded case limiting fuse circuit breaker 2 [A] [A] * 1 (15) 15 1 (15) 15 1 (15) 15 1 (15) 15 2 (15) 15 2 (15) 15 3 (15) 15 3 (15) 15 3 (15) 15 5 (15) 15 5 (15) 15 10 (15) 15 10 (15) 15 15 15 15 15 15 15 20 15 1 (15) 15 1 (15) 15 1 (15) 15 1 (15) 15 2 (15) 15 2 (15) 15 3 (15) 15 3 (15) 15 3 (15) 15 5 (15) 15 5 (15) 15 10 (15) 15 10 (15) 15 15 15 15 15 15 15 20 15 30 15 30 15 1 (15) 15 1 (15) 15 1 (15) 15 1 (15) 15 2 (15) 15 2 (15) 15 3 (15) 15 3 (15) 15 3 (15) 15 5 (15) 15 5 (15) 15 10 (15) 15 10 (15) 15 15 15 15 15 15 15 20 15 30 15 30 15 30 20 50 40 20 60 20 60 20 60 20 60 20 60 50 60 50 60 50 60 Applicable magnetic UL File No. starter types SW-03/3H, 03Y/3H *3 E44592 [SW-03/2E, 03Y/2E] SW-0/3H, 0Y/3H *3 SW-05/3H, 05Y/3H *3 SW-0/2E, 0Y/2E SW-05/2E, 05Y/2E SW-4-0/3H, SW-4-1/3H, SW-5-1/3H, 5-1Y/3H SW-4-0/2E SW-4-1/2E SW-5-1/2E, 5-1Y/2E SW-N1/3H [SW-N1/2E] E42419 Series Type No. of Reset heat elements Auxiliary contact NEO SC TR-N2/3 *4 Series [TK-N2] *4 3 Manual TR-N3/3 *4 [TK-N3] *4 3 Manual 1NO+1NC 4 - 6 (4) 5 - 8 (5) 6 - 9 (6) 7 - 11 (7) 9 - 13 (9) 12 - 18 (12) 18 - 26 (18) 24 - 36 (24) 32 - 42 (32) 1NO+1NC 7 - 11 (7) 9 - 13 (9) 12 - 18 (12) 18 - 26 (18) 24 - 36 (24) 28 - 40 (28) 34 - 50 (34) 45 - 65 (45) 7 - 11 (7) 9 - 13 (9) 12 - 18 (12) 18 - 26 (18) 24 - 36 (24) 28 - 40 (28) 34 - 50 (34) 45 - 65 (45) 48 - 68 (48) 1NO+1NC 7 - 11 (7) 9 - 13 (9) 12 - 18 (12) 18 - 26 (18) 24 - 36 (24) 28 - 40 (28) 34 - 50 (34) 45 - 65 (45) 53 - 80 (53) 7 - 11 (7) 9 - 13 (9) 12 - 18 (12) 18 - 26 (18) 24 - 36 (24) 28 - 40 (28) 34 - 50 (34) 45 - 65 (45) 53 - 80 (53) 65 - 95 (65) 1NO+1NC 45 - 65 (45) 53 - 80 (53) 65 - 95 (65) 85 - 125 (85) 1NO+1NC 45 - 65 (45) 53 - 80 (53) 65 - 95 (65) 85 - 125 (85) 110 - 160 (110) 1NO+1NC 53 - 80 (53) 65 - 95 (65) 85 - 125 (85) 110 - 160 (110) 125 - 185 (125) 1NO+1NC 85 - 125 (85) 110 - 160 (110) 125 - 185 (125) 160 - 240 (160) 1NO+1NC 110 - 160 (110) 125 - 185 (125) 160 - 240 (160) 200 - 300 (200) 1NO+1NC 110 - 160 (110) 125 - 185 (125) 160 - 240 (160) 200 - 300 (200) 240 - 360 (240) 300 - 450 (300) 1NO+1NC 240 - 360 (240) 300 - 450 (300) 400 - 600 (400) TR-N5/3 [TK-N5] 3 Manual TR-N6/3 *4 [TK-N6] *4 3 Manual TR-N7/3 [TK-N7] 3 Manual TR-N8/3 [TK-N8] 3 Manual TR-N10/3 *4 [TK-N10] *4 3 Manual TR-N12/3 *4 [TK-N12] *4 3 Manual TR-N12/3 *4 [TK-N12] *4 3 Manual TR-N14/3 *4 [TK-N14] *4 3 Manual Heat element rating [A] *1 *1 Protection coordination Max. rated Max. rated current of current of molded current limiting case circuit *2 fuse [A] breaker [A] 20 60 20 60 20 60 20 60 20 60 50 60 50 60 50 60 70 70 20 60 20 60 50 60 50 60 50 60 70 70 70 70 125 125 20 60 20 60 50 60 50 60 50 60 70 70 70 70 125 125 125 125 20 60 20 60 50 60 50 60 50 60 70 70 70 70 125 125 150 125 20 60 20 60 50 60 50 60 50 60 70 70 70 70 125 125 150 125 180 125 150 175 150 175 150 175 150 175 150 175 150 175 150 175 150 175 200 225 225 400 225 400 225 400 225 400 225 400 300 400 300 400 300 400 300 400 300 400 300 400 300 400 450 600 300 400 300 400 300 400 450 600 450 600 450 600 800 800 800 800 800 800 Applicable UL File No. magnetic starter types SW-N2/3H [SW-N2/2E] SW-N2S/3H [SW-N2S/2E] SW-N3/3H [SW-N3/2E] SW-N4/3H [SW-N4/2E] SW-N5/3H [SW-N5/2E] SW-N6/3H [SW-N6/2E] SW-N7/3H [SW-N7/2E] SW-N8/3H [SW-8N/2E] SW-N10/3H [SW-N10/2E] SW-N11/3H [SW-N11/2E] SW-N12/3H [SW-N12/2E] SW-N14/3H *3 [SW-N14/2E] Parenthesized values in the "Heat element rating" column are the nominal rating to be specified at order placement. Parenthesized values in the "Fuse rating" column are for CSA approved starters. 480V or less for a combination of SW-03(Y)/3H, -0(Y)/3H or -05(Y)/3H, SW-N14/3H and molded case circuit breaker *4 Separate mounting is available. *2 *3 18 E42419 z SC and SW series optional units Series Standard NEW SC Series NEO SC Series Name Type Auxiliary contact SZ-A40 block (Front SZ-A31 mounting) SZ-A22 SZ-A20 SZ-A11 SZ-A02 Auxiliary contact SZ-AS1 block SZ-AS2 (Side mounting) Interlock unit SZ-RM Coil surge SZ-Z1 suppression SZ-Z2 unit SZ-Z3 SZ-Z6 SZ-Z7 SZ-Z31 SZ-Z32 SZ-Z33 SZ-Z41 SZ-Z42 SZ-Z43 SZ-Z4 SZ-Z5 SZ-Z8 SZ-Z9 SZ-Z34 SZ-Z35 SZ-Z36 SZ-Z37 SZ-Z44 SZ-Z45 Main circuit SZ-ZM1 surge SZ-ZM2 suppression SZ-ZM3 unit SZ-ZM4 Terminal covers SZ-T5 SZ-T6 SZ-T7 SZ-T1 SZ-T2 SZ-T3 SZ-T4 SZ-T22 SZ-T23 SZ-T10 SZ-T11 SZ-T12 SZ-T13 SZ-T14 SZ-T15 SZ-T16 SZ-T17 SZ-N4T SZ-N6T SZ-N7T SZ-N8T SZ-N11T SZ-WN4T SZ-WN6T SZ-WN7T SZ-WN8T SZ-WN10T SZ-WN11T Separate SZ-HB mounting unit SZ-HC SZ-HD SZ-HE Reset release SZ-R1 button SZ-R2 SZ-R3 Dial cover SZ-DA Specification Applicable types UL File No. 4NO 3NO+1NC 2NO+2NC 2NO 1NO+1NC 2NC 1NO+1NC (mounted on both left and right sides) SC-03, 0, 05, 4-0, 4-1,5-1 *1, SH-4 *3, 5 SC-N1, N2, N2S, N3 E42419 A set of interlock and joint block Varistor 24 - 48V AC/DC Varistor 100 - 240V AC/DC Varistor 380 - 440V AC Varistor 24 - 48V AC/DC LED Varistor 100 - 240V AC/DC LED Varistor 24 - 48V AC/DC Varistor 100 - 250V AC/DC Varistor 380 - 440V AC Varistor 24 - 48V AC Varistor 100 - 250V AC Varistor 380 - 440V AC CR 24 - 48V AC/DC CR 100 - 240V AC/DC CR 24 - 48V AC/CD LED CR 100 - 240V AC/DC LED CR 24 - 48V AC CR 100 - 250V AC CR 24 - 48V DC CR 100 - 250V DC CR 24 - 48V AC CR 100 - 250V AC Front mounting 3-phase CR 250V AC Side mounting 3-phase CR 250V AC SC-03, 0, 05, 4-0, 4-1, 5-1, N1, N2, N2S, N3 SC-03 - 5-1, SH-4, 5 SC-03/G - 5-1/G, SH-4/G, 5/G SC-03 - 5-1, SH-4, 5 SC-03 - 5-1, SH-4, 5 SC-03/G - 5-1/G, SH-4/G, 5G SC-N1 - N3 SC-N1/G - N3/G SC-N1 - N3 SC-N4 SC-03, 0, 05, 4-0, 4-1, 5-1, N1, N2, N2S, N3, SH-4, 5 SC-N4, N5, N6, N7, N8, N10, N11, N12 SC-03 - 5-1, SH-4, 5 SC-N1 - N3 SC-N1/G - N3/G SC-N4 SC-03 - 5-1 *2 SC-N1 - N3 For auxiliary contact block (front mounting:) 4 poles SZ-A40, A31, A22, A20, A11, A02 For auxiliary contact block (front mounting:) 3 poles For auxiliary contact block (front mounting:) 2 poles SZ-AL, AR, AS1, AS2 For contactors (main terminals and coil terminals) SC-03, 0, SH-4 SC-05, SH-5 SC-4-0, 4-1, 5-1 SC-5-1 SC-N1, N2 SC-N2S, N3 For thermal overload relay separate mounting unit SZ-HB SZ-HC TR-0N For thermal overload relays TR-5-1N For separate mounting thermal overload relay TR-N2H TR-N3H For thermal overload relays TR-N2 TR-N3 For magnetic contactors (Terminal on power supply SC(SW)-N4, N5 side) SC(SW)-N6 For magnetic contactors (Terminal on load side) SC(SW)-N7 For magnetic starters (Terminal on power supply SC(SW)-N8, N10 side) SC(SW)-N11, N12 For magnetic starters (Terminal on load side) SW-N4, N5 SW-N6 SW-N7 SW-N8 SW-N10 SW-N11, N12 Separate mounting thermal overload relay TR-0N assembly TR-5-1N TR-N2 TR-N3 For resetting thermal overload relay (L=300mm) TR-0N, 5-1N For resetting thermal overload relay (L=500mm) For resetting thermal overload relay (L=700mm) For locking the current setting dial of thermal TR-0N, 5-1N overload relay Note 1: The main unit is approved to satisfy the UL/CSA standard when it is combined with operation counter (SZ-J) and/or live-section cover (SZ-JC, or JW). *1 Can not be mounted on 5-1(Y) type of 2NO+2NC auxiliary contacts. *2 SZ-ZM1 type can not be mounted on 5-1(Y) type of 2NO+2NC auxiliary contacts. *3 Can not be mounted on SH-4 type of 8 auxiliary contacts. 19 zContactors / SC-M series - AC operated non-reversing magnetic contactors Series Standard Type Max. motor capacity [HP] ( ): Rated operational current Continuous UL File No. current [A] Single-phase 3-phase squirrel-cage 110-120V 220-240V 200V 220-240V 400-480V 550-600V 1/3 (7.2A) 1 (4.2A) 1.5 (6.9A) 1.5 (6A) 3 (4.8A) 3 (3.9A) 20 E42419 SC-M Series SC-M01 SC-M02 1/2 (9.8A) 1.5 (6A) 3 (11A) 3 (9.6A) 5 (7.6A) 5 (6.1A) 20 - DC operated non-reversing magnetic contactors Series Standard Type Max. motor capacity [HP] ( ): Rated operational current Single-phase 3-phase squirrel-cage 110-120V 220-240V 200V 220-240V 400-480V 550-600V 1/3 (7.2A) 1 (4.2A) 1.5 (6.9A) 1.5 (6A) 3 (4.8A) 3 (3.9A) 1/3 (7.2A) 1 (4.2A) 1.5 (6.9A) 1.5 (6A) 3 (4.8A) 3 (3.9A) 1/3 (7.2A) 1 (4.2A) 1.5 (6.9A) 1.5 (6A) 3 (4.8A) 3 (3.9A) 1/2 (9.8A) 1.5 (6A) 3 (11A) 3 (9.6A) 5 (7.6A) 5 (6.1A) 1/2 (9.8A) 1.5 (6A) 3 (11A) 3 (9.6A) 5 (7.6A) 5 (6.1A) 1/2 (9.8A) 1.5 (6A) 3 (11A) 3 (9.6A) 5 (7.6A) 5 (6.1A) SC-M Series SC-M01/G SC-M01/G1 SC-M01/G2 SC-M02/G SC-M02/G1 SC-M02/G2 Continuous UL File No. current [A] 20 20 20 20 20 20 E42419 - AC operated reversing magnetic contactors Series Standard Type SC-M Series SC-M01RM SC-M02RM Max. motor capacity [HP] ( ): Rated operational current 3-phase 200V 220-240V 400-480V 550-600V 1.5 (6.9A) 1.5 (6A) 3 (4.8A) 3 (3.9A) Continuous UL File No. current [A] 3 (11A) 20 3 (9.6A) 5 (7.6A) 5 (6.1A) 20 E42419 -DC operated reversing magnetic contactors Series Standard Type Max. motor capacity [HP] ( ): Rated operational current 3-phase 200V 220-240V 400-480V 550-600V 1.5 (6.9A) 1.5 (6A) 3 (4.8A) 3 (3.9A) 1.5 (6.9A) 1.5 (6A) 3 (4.8A) 3 (3.9A) 1.5 (6.9A) 1.5 (6A) 3 (4.8A) 3 (3.9A) 3 (11A) 3 (9.6A) 5 (7.6A) 5 (6.1A) 3 (11A) 3 (9.6A) 5 (7.6A) 5 (6.1A) 3 (11A) 3 (9.6A) 5 (7.6A) 5 (6.1A) SC-M Series SC-M01/GRM SC-M01/G1RM SC-M01/G2RM SC-M02/GRM SC-M02/G1RM SC-M02/G2RM Continuous UL File No. current [A] 20 20 20 20 20 20 E42419 - 2E thermal overload relay Series Standard Type SC-M Series TK-M0 TK-M0Q No. of heat Reset elements Auxiliary contact 3 Manual/Auto 1NC 3 Manual/Auto 1NC 20 Heat element Applicable Protection UL File No. rating [A] magnetic coordination contactor types Fuse rating [A] Class K-5 E44592 0.11-0.17 1 SC-M01 SC-M01/G 0.17-0.26 1 0.26-0.43 1 SC-M01RM SC-M01/GRM 1 0.43-0.65 0.65-1.0 3 SC-M02 SC-M02/G 0.85-1.3 3 SC-M02RM 1.1-16 6 SC-M02/GRM 6 1.35-2.0 1.7-2.4 6 2.2-3.2 10 2.5-4.0 15 3.0-4.7 15 4.0-6.3 20 5.5-8.0 30 7.5-10.5 40 1.35-2.0 6 1.7-2.4 10 2.2-3.2 15 3.0-4.7 15 4.0-6.3 20 5.5-8.0 30 7.4-10.5 40 - SC-M Series optional accessories Series Model Standard SC-M Series Auxiliary contact block (Front mounting) Type SZ-MA40 SZ-MA31 SZ-MA22 SZ-MA13 SZ-MA04 SZ-MA20 SZ-M11 SZ-MA02 Auxiliary contact block SZ-MAS10 (Side mounting) SZ-MAS01 Coil surge suppression SZ-MZ1 unit SZ-MZ2 SZ-MZ3 Interlock unit SZ-MRM Reversing connection kit SZ-MRWC Solid-state time-delay SZ-MT2 unit SZ-MT5 Input terminal SZ-MHT Base unit SZ-MHB Auxiliary contact block SZ-MA10 Specification Applications UL File No. 4NO, A600, Q600 3NO+1NC, A600, Q600 2NO+2NC, A600, Q600 1NO+3NC, A600, Q600 4NC, A600, Q600 2NO, A600, Q600 1NO+1NC, A600, Q600 2NC, A600, Q600 1NO, A600, Q600 1NC, A600, Q600 CR 12 - 60V AC/DC 50/60Hz CR 72 - 250V AC/DC 50/60Hz Built-in diode (6 - 250V DC) A set of interlock and joint block Reversing circuit wiring kit ON delay 0.2 - 24s ON delay 0.5 - 60s Separate mounting thermal relay input terminal DIN 35mm-wide rail mounted, screw mounted Contact arrangement : 1NC, A600, Q600 SC-M01 SC-M01/G SC-M02 SC-M02/G E44592 TK-M0 TK-M0Q z Contactors / SC-E Series - AC operated / Non-reversing contactors Series Standard Type SC-E Series SC-E02 SC-E03 SC-E04 SC-E05 SC-E1 SC-E2 SC-E2S SC-E3 SC-E4 SC-E5 SC-E6 SC-E7 Rated capacity [HP] Single-phase motor 110-120V 220-240V 1/3 (7.2A) 1 (8A) 1/2 (9.8A) 2 (12A) 1 (16A) 3 (17A) 2 (24A) 3 (17A) 2 (24A) 3 (17A) 3 (34A) 5 (28A) 3 (34A) 10 (50A) 5 (56A) 15 (68A) 5 (56A) 15 (68A) 7.5 (80A) 15 (68A) 10 (100A) 20 (88A) 15 (135A) 25 (110A) ( ): Rated operational current 3-phase squirrel cage motor 200V 220-240V 440-480V 2 (7.8A) 2 (6.8A) 5 (7.6A) 3 (11A) 3 (9.6A) 7 1/2 (11A) 5 (17.5A) 5 (15.2A) 10 (14A) 5 (17.5A) 7 1/2 (22A) 15 (21A) 7.5 (25.3A) 10 (28A) 25 (34A) 10 (32.2A) 15 (42A) 30 (40A) 15 (48.3A) 20 (54A) 30 (40A) 20 (62.1A) 25 (68A) 50 (65A) 25 (78.2A) 30 (80A) 50 (65A) 30 (92A) 30 (80A) 60 (77A) 40 (119.6A) 40 (104A) 75 (96A) 50 (149.5A) 50 (130A) 100 (124A) Continuous UL File No. current [A] 550-600V 5 (6.1A) 7 1/2 (9A) 10 (11A) 15 (17A) 25 (27A) 30 (32A) 30 (32A) 50 (52A) 50 (52A) 75 (77A) 100 (99A) 125 (125A) 20 20 25 32 50 60 65 100 105 150 150 200 E42419 - DC operated / Non-reversing contactors Series Standard Type SC-E Series SC-E02/G SC-E03/G SC-E04/G SC-E05/G SC-E1/G SC-E2/G SC-E2S/G SC-E3/G SC-E4/G SC-E5 SC-E6 SC-E7 Rated capacity [HP] Single-phase motor 110-120V 220-240V 1/3 (7.2A) 1 (8A) 1/2 (9.8A) 2 (12A) 1 (16A) 3 (17A) 2 (24A) 3 (17A) 2 (24A) 3 (17A) 3 (34A) 5 (28A) 3 (34A) 10 (50A) 5 (56A) 15 (68A) 5 (56A) 15 (68A) 7.5 (80A) 15 (68A) 10 (100A) 20 (88A) 15 (135A) 25 (110A) ( ): Rated operational current 3-phase squirrel cage motor 200V 220-240V 440-480V 2 (7.8A) 2 (6.8A) 5 (7.6A) 3 (11A) 3 (9.6A) 7 1/2 (11A) 5 (17.5A) 5 (15.2A) 10 (14A) 5 (17.5A) 7 1/2 (22A) 15 (21A) 7.5 (25.3A) 10 (28A) 25 (34A) 10 (32.2A) 15 (42A) 30 (40A) 15 (48.3A) 20 (54A) 30 (40A) 20 (62.1A) 25 (68A) 50 (65A) 25 (78.2A) 30 (80A) 50 (65A) 30 (92A) 30 (80A) 60 (77A) 40 (119.6A) 40 (104A) 75 (96A) 50 (149.5A) 50 (130A) 100 (124A) 21 Continuous UL File No. current [A] 550-600V 5 (6.1A) 7 1/2 (9A) 10 (11A) 15 (17A) 25 (27A) 30 (32A) 30 (32A) 50 (52A) 50 (52A) 75 (77A) 100 (99A) 125 (125A) 20 20 25 32 50 60 65 100 105 150 150 200 E42419 - 2E thermal overload relay Series Standard Type No. of heat Reset elements SC-E Series TK-E02 3 Auxiliary Heat element contact ratings [A] arrangement Manual / Auto 1NO + 1NC 0.1-0.15 0.13-0.2 0.15-0.24 0.2-0.3 0.24-0.36 0.3-0.45 0.36-0.54 0.48-0.72 0.64-0.96 0.8-1.2 0.95-1.45 1.4-2.2 1.7-2.6 2.2-3.4 2.8-4.2 4-6 5-8 6-9 7-11 0.1-0.15 0.13-0.2 0.15-0.24 0.2-0.3 0.24-0.36 0.3-0.45 0.36-0.54 0.48-0.72 0.64-0.96 0.8-1.2 0.95-1.45 1.4-2.2 1.7-2.6 2.2-3.4 2.8-4.2 4-6 5-8 6-9 7-11 9-13 0.1-0.15 0.13-0.2 0.15-0.24 0.2-0.3 0.24-0.36 0.3-0.45 0.36-0.54 0.48-0.72 0.64-0.96 0.8-1.2 0.95-1.45 1.4-2.2 1.7-2.6 2.2-3.4 2.8-4.2 4-6 5-8 6-9 7-11 9-13 12-18 0.1-0.15 0.13-0.2 0.15-0.24 0.2-0.3 0.24-0.36 0.3-0.45 0.36-0.54 0.48-0.72 0.64-0.96 0.8-1.2 0.95-1.45 1.4-2.2 1.7-2.6 2.2-3.4 2.8-4.2 4-6 5-8 6-9 7-11 22 (0.1) (0.13) (0.15) (0.2) (0.24) (0.3) (0.36) (0.48) (0.64) (0.8) (0.95) (1.4) (1.7) (2.2) (2.8) (4) (5) (6) (7) (0.1) (0.13) (0.15) (0.2) (0.24) (0.3) (0.36) (0.48) (0.64) (0.8) (0.95) (1.4) (1.7) (2.2) (2.8) (4) (5) (6) (7) (9) (0.1) (0.13) (0.15) (0.2) (0.24) (0.3) (0.36) (0.48) (0.64) (0.8) (0.95) (1.4) (1.7) (2.2) (2.8) (4) (5) (6) (7) (9) (12) (0.1) (0.13) (0.15) (0.2) (0.24) (0.3) (0.36) (0.48) (0.64) (0.8) (0.95) (1.4) (1.7) (2.2) (2.8) (4) (5) (6) (7) Protection coordination AC 600V Max. AC 600V Max. rated current of rated current of UL breaker [A] UL fuse [A] 15 15 15 15 15 15 15 15 15 15 15 15 15 15 15 15 15 15 15 15 15 15 20 15 20 15 20 15 20 15 20 15 20 15 20 30 20 30 15 15 15 15 15 15 15 15 15 15 15 15 15 15 15 15 15 15 15 15 15 15 20 15 20 15 20 15 20 15 20 15 20 15 20 30 20 30 30 30 15 15 15 15 15 15 15 15 15 15 15 15 15 15 15 15 15 15 15 15 15 15 20 15 20 15 20 15 20 15 20 15 20 15 20 30 20 30 30 30 30 50 15 15 15 15 15 15 15 15 15 15 15 15 15 15 15 15 15 15 15 15 15 15 20 15 20 15 20 15 20 15 20 15 20 15 20 30 20 30 Applicable UL File No. magnetic contactor types SC-E02, E02/G SC-E03, E03/G SC-E04, E04/G SC-E05, E05/G E44592 Series Standard Type No. of heat Reset elements SC-E Series TK-E02 3 Manual / Auto 1NO + 1NC TK-E2 3 Manual / Auto 1NO + 1NC TK-E3 3 Auxiliary Heat element contact ratings [A] arrangement Manual / Auto 1NO + 1NC TK-E5 3 Manual / Auto 1NO + 1NC TK-E6 3 Manual / Auto 1NO + 1NC 9-13 12-18 16-22 20-25 4-6 5-8 6-9 7-11 9-13 12-18 18-26 24-36 4-6 5-8 6-9 7-11 9-13 12-18 18-26 24-36 32-42 4-6 5-8 6-9 7-11 9-13 12-18 18-26 24-36 32-42 40-50 44-54 7-11 9-13 12-18 18-26 24-36 28-40 34-50 45-65 48-68 7-11 9-13 12-18 18-26 24-36 28-40 34-50 45-65 48-68 64-80 18-26 24-36 28-40 34-50 45-65 65-95 85-105 45-65 53-80 65-95 85-125 45-65 53-80 65-95 85-125 110-160 23 (9) (12) (16) (20) (4) (5) (6) (7) (9) (12) (18) (24) (4) (5) (6) (7) (9) (12) (18) (24) (32) (4) (5) (6) (7) (9) (12) (18) (24) (32) (40) (44) (7) (9) (12) (18) (24) (28) (34) (45) (48) (7) (9) (12) (18) (24) (28) (34) (45) (48) (64) (18) (24) (28) (34) (45) (65) (85) (45) (53) (65) (85) (45) (53) (65) (85) (110) Protection coordination AC 600V Max. AC 600V Max. rated current of rated current of UL breaker [A] UL fuse [A] 30 30 30 50 50 50 50 50 60 20 60 20 60 20 60 20 60 20 60 50 60 50 50 50 60 20 60 20 60 20 60 20 60 20 60 50 60 50 50 50 70 70 60 20 60 20 60 20 60 20 60 20 60 50 60 50 50 50 70 70 70 70 70 70 60 20 60 20 60 50 60 50 50 50 70 70 70 70 125 125 125 125 60 20 60 20 60 50 60 50 50 50 70 70 70 70 125 125 125 125 125 125 60 50 50 50 70 70 70 70 125 125 125 150 125 150 175 150 175 150 175 150 175 150 175 150 175 150 175 150 175 150 225 200 Applicable UL File No. magnetic contactor types SC-E05, E05/G SC-E1, E1/G SC-E2, E2/G SC-E2S, E2S/G SC-E3, E3/G SC-E4, E4/G SC-E5 SC-E6 SC-E7 E44592 z SJ series high-sensitivity contactor (open type) Standard Non-reversible types Magnetic Magnetic starters contactor Type Type SJ Series SJ-0G, 06G SJ-0WG/N3H, 06WG/N3H SJ-0WG/2E, 06WG/2E SJ-1SG SJ-1SWG/3H SJ-1SWG/2E Standard Reversible types Magnetic Magnetic starters contactor Type Type SJ Series SJ-0G, 06G SJ-0WGRM/N3H, 06WGRM/N3H SJ-0WGRM/2E, 06WGRM/2E SJ-1SG SJ-1SWGRM/3H SJ-1SWGRM/2E Max. motor capacity [HP] Continuous Auxiliary Coil *1 current [A] contact voltage arrangement code Single-phase 110- 220120V 240V 1/3 1 3-phase 110- 220V 220- 440120V 240V 480V 1 2 3 15 1 2 2 5 5 12V DC 24V DC E42419 Continuous Auxiliary Coil *1 current [A] contact voltage arrangement code UL File No. 7 1/2 25 Max. motor capacity [HP] Single-phase 110- 220120V 240V 1/3 1 3-phase 110- 220V 220- 440120V 240V 480V 1 2 3 15 1 2 2 5 5 1NO, 1NC UL File No. 2NO, 2NO+2NC 1NO, 1NC 7 1/2 25 12V DC 24V DC E42419 2NO, 1NO+1NC *1 Applicable when used as magnetic contactor Notes 1: Allowable voltage variation is 85% to 110% of rated voltage. 2: Be careful of the polarity of operation coil terminals. z FC Series AC operated magnetic contactors (open type) Series Standard Type FC Series FC-0UL FC-0TUL FC-0SUL FC-0STUL FC-0/GUL FC-0T/GUL FC-1UL FC-1SUL FC-2SUL FC-3UL FC-4UL Max. motor capacity [HP] Continuous current [A] Single-phase 3-phase 110-120V 220-240V 200V 220-240V 440-480V 550-600V 1/2 1 1 1 15 Auxiliary contact arrangement 1NO, 1NC 1 2 3 3 5 20 26 35 45 65 1NO+1NC 1NO+1NC 1NO+1NC 1NO+1NC 1NO+1NC Continuous current [A] Auxiliary contact arrangement 1NO, 1NC 2 3 5 7.5 10 5 5 10 10 15 5 7.5 10 15 20 7.5 10 15 25 30 7.5 7.5 10 15 25 UL File No. E42419 z FC Series DC operated magnetic contactors (open type) Series Standard Type FC Series FC-0/GUL FC-0T/GUL FC-0S/GUL FC-0ST/GUL Max. motor capacity [HP] Single-phase 3-phase 110-120V 220-240V 200V 1/2 1 1 220-240V 1 24 380-440V - 15 UL File No. E42419 z SB series DC magnetic contactors Continuous UL File current [A] No. DC motor (class DC2/DC4) NO contact Dynamic brake applied NO contact (2 serial poles) NC contact (2 serial poles) (activation time: 3 seconds) 110V 240V 440V 550V 110V 240V 440V 550V 110V 240V 440V 550V NC contact Main contact Operational current [A] arrangement For variable-speed motor NO contact Series Type Standard SB Series SB-2N/UL 2NO E42419 50 50 35 35 75 75 75 75 40 35 18 15 50 50 SB-2NB/UL 2NO+1NC SB-2N/SEUL 2NO 50 50 35 35 75 75 75 75 40 35 18 15 50 50 SB-2NB/SEUL 2NO+1NC SB-5N/UL 2NO 110 110 110 110 165 165 165 165 85 85 60 45 110 100 SB-5NB/UL 2NO+1NC SB-6N/UL 2NO 140 140 140 140 210 210 210 210 125 120 80 50 140 100 SB-6NB/UL 2NO+1NC SB-10N/UL 2NO 240 240 240 240 360 360 360 360 240 200 120 100 240 160 SB-10NB/UL 2NO+1NC SB-11N/UL 2NO 320 320 320 320 480 480 480 480 320 290 200 150 320 200 SB-11NB/UL 2NO+1NC Notes 1: The duty for variable-speed motor control (NO contact) and that for dynamic brake (NC contact) are applicable to the no-voltage circuit of twice the making capacity and to that of one time the making capacity, respectively. 2: The continuous current values for dynamic brake application are for the intermittent operation of 600 cycle/hour and 3-second activation time. 3: The values for DC motor application are applicable to the motor load of class DC2 (start/stop of shunt motors - time constant L/R: 2ms when closed and 7.5ms when open) or DC4 (start/stop of series motors - time constant L/R: 7.5ms when closed and 10ms when open) under JEM1038. 25 z Standard application of built-in thermal overload relays Type No. of Reset heat elements Auxiliary contact arrangement Heat element ratings [A] Protection coordination Applicable Max. rated current Max. rated current magnetic starter types of current limiting of molded case *1 circuit breaker [A] fuse [A] TR-0/UL 3 1(NO+NC) 0.48 - 0.72 (0.48) 15 15 0.64 - 0.96 (0.64) 15 15 0.8 - 1.2 (0.8) 15 15 0.95 - 1.45 (0.95) 15 15 1.4 - 2.2 (1.4) 15 15 1.7 - 2.6 (1.7) 15 15 2.2 - 3.4 (2.2) 15 15 2.8 - 4.2 (2.8) 15 15 4 - 6 (4) 15 15 5 - 8 (5) 20 15 6 - 9 (6) 30 15 7 - 9.6 (7) 30 15 0.1 - 0.15 (0.1) 1 (15) - 0.15 - 0.24 (0.15) 1 (15) 0.24 - 0.36 (0.24) 2 (15) 0.36 - 0.54 (0.36) 3 (15) 0.54 - 0.72 (0.48) 3 (15) 0.64 - 0.96 (0.64) 3 (15) 0.8 - 1.2 (0.8) 5 (15) 0.95 - 1.45 (0.95) 5 (15) 1.4 - 2.2 (1.4) 10 (15) 1.7 - 2.6 (1.7) 10 (15) 2.2 - 3.4 (2.2) 15 2.8 - 4.2 (2.8) 15 4 - 6 (4) 15 5 - 8 (5) 20 TR-0N/3Z716 3 Manual Manual/Auto 1NO+1NC TK-0NZ716 TR-5-1N/3 TK-5-1N 3 Manual/Auto 1NO+1NC 6 - 9 (6) 30 7 - 11 (7) 30 0.1 - 0.15 (0.1) 1 (15) 0.15 - 0.24 (0.15) 1 (15) 0.24 - 0.36 (0.24) 2 (15) 0.36 - 0.54 (0.36) 3 (15) 0.48 - 0.72 (0.48) 3 (15) 0.64 - 0.96 (0.64) 3 (15) 0.8 - 1.2 (0.8) 5 (15) 0.95 - 1.45 (0.95) 5 (15) 1.4 - 2.2 (1.4) 10 (15) 1.7 - 2.6 (1.7) 10 (15) 2.2 - 3.4 (2.2) 15 2.8 - 4.2 (2.8) 15 4 - 6 (4) 15 5 - 8 (5) 20 6 - 9 (6) 30 7 - 11 (7) 30 9 - 13 (9) 30 12 - 18 (12) 30 *1 SJ-0WG/UL SJ-0WG/NUL SJ-0WG/2EUL - SJ-1SWG/UL SJ-1SWG/2EUL Parenthesized values in the fuse rating column are for CSA approved products. Note 1: Parenthesized figures in the "Heat element rating" column are the nominal rating to be specified at order placement. 26 Solid-state Contactors z 3-pole Solid-state contactors Series Standard Rated main-circuit voltage Type Main body SS Series 100-240V AC SS032 SS033 SS082 SS083 SS202 SS203 SS302 SS303 SS402 SS403 SS502 SS503 SS802 SS803 SS1202 SS1203 200-480V AC SS302H SS303H SS502H SS503H SS802H SS803H SS1202H SS1203H Number of main circuit elements 2 3 Fins 2 integrated into 3 main body SX1-D10 2 SX1-D10 3 SX1-D10 2 SX1-E12 3 SX1-D14 2 SX1-E12 3 SX1-E12 2 SX1-E17 3 SX1-C12 2 SX1-C12 3 SX1-C12 2 SX1-C12 3 SX1-E12 2 SX1-E12 3 SX1-E12 2 SX1-E17 3 SX1-C12 2 SX1-C12 3 SX1-C12 2 SX1-C12 3 Cooling fin Continuous Max. motor capacity [HP] (at 60 Hz) current [A] Single-phase 3-phase 110-120V 220-240V 220-240V 440-480V UL File No. 3 - 1/10 1/2 - E132864 8 1/10 1/4 3/4 - 20 1/6 1/2 1 1/2 - 30 1/3 1 2 - 40 1/2 1 1/2 3 - 50 1 3 5 - 80 3 5 10 - 120 3 5 10 - 30 - 1 5 - 50 - 3 5 10 80 - 5 10 20 120 - 5 10 20 Notes 1: Figures in "Continuos current" and "Max. motor capacity" columns are those when operated at 40 C in ambient temperature with cooling fins mounted. 2: Motor running conditions: make-break frequency =1200 times per hour; duty cycle = 25%; motor starting current = 6 times the total load current; motor starting time = 0.7 second or less. z Single-pole Solid-state contactors Series Standard SS Series Rated Type main-circuit voltage 100-240V AC SS101 SS201 SS301 SS401 SS501 SS701 SS1001 SS1501 SS2001 200-480V AC SS701H SS1001H SS1501H SS2001H Number of main circuit elements 1 1 1 1 1 1 1 1 1 1 1 1 1 Continuous current [A] 10 20 30 40 50 70 100 150 200 70 100 150 200 Max. motor capacity [HP] (at 60 Hz) Single-phase 3-phase 120V 240V 240V 2 5 3 3 7 1/2 5 5 10 10 7 1/2 15 10 5 10 10 7 1/2 15 15 10 25 20 20 40 30 z Solid-state contactor for DC load or exclusively for heater load Series Standard Rated Type main-circuit voltage For DC load 24 -240V DC SS031D Exclusively for 100-240V AC SS101C heater load SS201C SS301C Number of main circuit elements 1 1 Continuous current [A] UL File No. 3 10 20 30 E142975 27 UL File No. 480V 10 15 20 30 20 30 40 60 E132864 Molded Case Circuit Breakers/Earth Leakage Circuit Breakers z EA-UL Series Series Type Current [A] Poles 2 Voltage [V] AC 240 Interrupting capacity [kA] UL240V IEC230V 14 25 SA-UL Series EA100CUL 60, 70, 75, 80, 90,100 3 240 14 Poles Voltage [V] AC 240 240 240 240 480 480 240 240 480 480 240 240 480 480 480 480 Interrupting capacity [kA] UL240V IEC230V 14 25 14 25 35 50 35 50 85 100 85 100 35 50 35 50 85 100 85 100 42 50 42 50 85 85 85 85 85 85 85 85 UL File No. E90584 (UL489) 25 z SA-UL Series Series Type Current [A] SA-UL Series SA50RCUL 3, 5, 10, 15, 20, 30, 40, 50 SA100CUL SA100CUL SA225CUL SA225RCUL SA400CUL SA400RCUL SA600RCUL SA800RCUL 2 3 15, 20, 30, 40, 50, 60, 70, 75, 2 80, 90, 100 3 15, 20, 30, 40, 50, 60, 70, 75, 2 80, 90, 100 3 125, 150, 175, 200, 225 2 3 125, 150, 175, 200, 225 2 3 250, 300, 350, 400 2 3 250, 300, 350, 400 2 3 500, 600 3 700, 800 3 Note 1: Product conforming to UL508: indication in applicable load output [HP]. 28 UL File No. E90584 (UL489) z External operating handles Series V-type handle Type BZ6V10C BZ6V30C BZ6V40C BZ6V60C BZ6V70C N-type handle BZ6N10C BZ6N10CP BZ6N30CP BZ6N40CP BZ6N60CP BZ6N70CP Flange-type BZ6UF30D handle BZ6UF40D BZ6UF60D Applicable model MCCBs E series EA32AC, 33AC EA52AC. 53AC EA52C, 53C EA62C, 63C EA103AC, 102C, 103C EA102CUL, 103CUL - UL File No. S series SA32C, 33C SA52C, 53C SA52RC, 53RC SA62C, 63C SA62RC, 63RC SA52RCUL, 53RCUL SA102C, 103C SA102CUL, 103CUL SA102RC, 103RC SA102RCUL, 103RCUL EA202C, 203C SA202C, 203C SA202CUL, 203CUL SA202RC, 203RC SA202RCUL, 203RCUL EA402C, 403C SA402C, 403C SA402CUL, 403CUL SA402RC, 403RC SA402RCUL, 403RCUL EA603C, 803C SA603RC, 803RC SA603RCUL, 803RCUL EA32AC, 33AC SA32C, 33C EA52AC, 53AC SA52C, 53C EA52C, 53C SA52RC, 53RC EA62C, 63C SA62C, 63C EA103AC, 102C, 103C SA62RC, 63RC EA102CUL, 103CUL SA52RCUL, 53RCUL SA102CUL, 103CUL SA102RCUL, 103RCUL SA202CUL, 203CUL SA202RCUL, 203RCUL SA402CUL, 403CUL SA402RCUL, 403RCUL SA603RCUL, 803RCUL SA100CUL SA100RCUL SA225CUL SA225RCUL SA400CUL SA400RCUL 29 ELCBs E series EG32AC, 33AC, 33C EG52AC, 53AC, 53C EG63C EG103AC, 102C, 103C EG102CUL, 103CUL - S series SG33C SG53C SG53RC SG63C SG63RC SG53RCUL SG103C SG103CUL SG103RC EG203C SG203C SG203CUL SG203RC EG403C SG403C SG403CUL SG403RC EG603C EG803C EG32AC, 33AC, 33C EG52AC, 53AC, 53C EG63C EG103AC, 102C, 103C SG603RC SG803RC SG33C SG53C SG53RC SG63C SG63RC EG102CUL, 103CUL SG53RCUL SG103CUL - SG203CUL - SG403CUL - SG103CUL - SG203CUL - SG403CUL E93289 (UL489) E216772 (UL508) E93289 (UL489) E93289 (UL489) z -TWIN Series (UL 508 listed ) Frame [A] Type Pole Rated operating voltage [V] Rated current [A] UL508 3-phase Applicable load output [Hp], for 3 poles 30 50 EA32AC EA33AC EA52AC EA53AC EA52C 2 3 2 3 2 240 240 550 AC AC550V (550-600V) AC440-480V AC220-240V AC110-120V Single- Applicable load AC550V phase output [Hp] (550-600V) AC440-480V AC220-240V AC110-120V UL File No. Frame [A] Type Pole Rated operating voltage [V] Rated current [A] UL508 3-phase Applicable load output [Hp], for 3 poles AC550V (550-600V) AC440-480V AC220-240V AC110-120V Single- Applicable load AC550V phase output [Hp] (550-600V) AC440-480V AC220-240V AC110-120V UL File No. EA103C 3 3 - 5 - 10 15 20 30 5 10 15 20 30 40 50 5 10 15 20 30 40 50 60 - - - - - - - 1 3 5 7.5 10 15 20 25 60 75 100 60 - - 25 75 30 100 40 - 0.5 - 1 0.5 - 10 3 - 10 5 - 15 7.5 - 20 10 15 25 10 20 30 15 25 5 2 5 3 10 7.5 5 3 - 15 5 - 20 7.5 - 2 3/4 - 2 1 - 3 2 - 0.5 - - - 1 2 2 0.5 3/4 1 - - - 3 2 - 5 2 - - 1 2 3 5 10 1 2 2 3 3 - - - - - 0.5 1.5 3 3 5 10 15 20 5 7.5 10 - - 7.5 10 15 7.5 0.5 - - - - - - - - 1 2 3 5 5 7.5 10 0.1 1/6 1/3 3/4 1 2 1/6 1/3 3/4 1 2 3 3 1/6 1/3 3/4 1 2 3 3 5 1/6 1/4 1/3 3/4 - 1/6 1/4 1/3 3/4 1 1.5 - 1/6 1/4 1/3 3/4 1 1.5 - E216772 30 SA32C 2 550 AC 60 100 EA62C EA63C EA103AC EA102C 2 3 3 2 550 240 600 EA53C 3 50 SA52C 2 600 SA33C 3 SA53C 3 3 5 10 15 20 30 5 3/4 0.5 - 1 1 0.5 - 3 2 1 - 5 3 2 - 7.5 5 2 - 10 10 3 - 3 2 0.5 1 - - 0.5 1/6 - 1.5 1 1/3 - 3 2 3/4 - 3 3 1 - 5 5 2 - 0.5 1.5 3 SA53RC 3 60 SA62C 2 600 SA63C 3 10 15 20 30 40 50 10 15 20 30 40 50 60 1 1 5 3 2 - 7.5 10 15 20 3 5 2 - 3 3 1/6 1/3 3/4 1 - SA52RC 2 600 1 2 10 10 15 2 3 5 7.5 1 5 5 2 - 5 3 2 - 7.5 5 2 - 7.5 10 1.5 3 5 3 - 3 2 3 1/3 3/4 1 - 7.5 1 3 - SA62RC 2 600 SA63RC 3 60 10 10 3 - 15 10 5 - 20 15 7.5 - 25 20 10 - 25 20 10 - 5 5 2 - 7.5 5 3 - 10 7.5 3 - 15 10 5 - 15 10 5 - E216772 z EG-UL Series Series Type Rated current Poles SG-UL, EG-UL Series EG100CUL 60, 75, 100 2 3 Rated operating voltage [V] AC 240 240 Interrupting capacity [kA] UL240V IEC230V UL File No. 14 14 E90584 (UL489) 10 10 z SG-UL Series Series Type Current [A] Poles 3 Voltage [V] AC 240 Interrupting capacity [kA] UL240V IEC230V 14 25 SA-UL Series SG50RCUL 3, 5, 10, 15, 20, 30, 40, 50 SG100CUL 32, 40, 50, 60, 75,100 3 240 35 50 SG225CUL 125, 150, 175, 200, 225 3 240 35 50 SG400CUL 250, 300, 350, 400 3 480 42 50 Note 1: Product conforming to UL508: indication in applicable load output [HP]. 30 UL File No. E90584 (UL489) z -TWIN Series (UL 508 listed ) Frame [A] Type Pole Rated operating voltage [V] AC Rated current [A] UL508 3-phase Applicable load AC220-240V output [Hp], for 3 poles Single- Applicable load AC220-240V phase output [Hp] High-speed Rated operating AC type voltage [V] [UL508 (cUL) ] Rated sensitive current In [mA] [UL508 (cUL) ] Pick-up current [UL1053] 30 EG32AC EG33AC EG33C 2 3 3 240 5 10 15 20 30 0.5 1 2 2 3 50 EG52AC EG53AC EG53C 2 3 3 240 5 10 15 20 30 40 50 0.5 1 2 2 3 5 7.5 60 EG63C 3 240 60 10 100 EG103AC 3 240 60 75 100 10 10 15 1/6 1/6 5 5 240 240 240 30,100/200 100/200 Tripping time (S) [UL1053] UL File No. 0.1 or less E216772 Frame [A] Type Pole Rated operating voltage [V] AC Rated current [A] UL508 3-phase Applicable AC220-240V load output [Hp], for 3 poles Single- Applicable AC220-240V phase load output [Hp] High-speed Rated operating AC type voltage [V] [UL508 (cUL) ] Rated sensitive current In [mA] [UL508 (cUL) ] Pick-up current [UL1053] 30 50 SG33C SG53C 3 3 240 240 3 5 10 15 20 30 5 10 - 0.5 1 2 2 3 0.5 1 15 2 20 2 30 3 40 5 - 3/4 1 2 3 Tripping time (S) [UL1053] UL File No. 0.1 or less E216772 1/3 3/4 1 2 240 1/3 3/4 1 2 3 3 240 15, 30, 100 15, 30, 100/200 5 EG102C EG103C 2 3 240 60 75 100 10 10 15 7.5 5 5 0.7 x rated sensitive current 1/6 1/3 3/4 1 240 2 1/6 50 7.5 60 SG63C 3 240 60 10 60 10 3 5 5 240 240 SG53RC 3 1/3 240 240 30, 100/200/500 0.7 x rated sensitive current 31 SG63RC 3 7.5 100/200/500 z BU A series Series UL approved Type BU-240V dedicated BU-ECA BU-GCA BU-GDA BU-KDA Current [A] Poles Voltage [V] AC DC 5, 10, 15, 20, 30, 40, 50, 60, 2 70, 80, 100 3 125, 150, 175, 200, 225 2 3 125, 150, 175, 200, 225 2 3 250, 300, 350, 400 2 3 240V - Interrupting capacity [kA] AC [V] DC [V] 240 480 250 125/250 10 - 240V - 10 - - - 240V - 22 - - - 240V 250 - 22 - 10 - 10 - Voltage [V] AC DC UL File No. E90584 z BU B series Series UL approved Type Current [A] BU standard BU-JSB 125, 150, 175, 200, 225, 250 2 3 250, 300, 350, 400 2 3 500, 600 2 3 700, 800 2 3 1000, 1200 2 3 125, 150, 175, 200, 225, 250 2 3 250, 300, 350, 400 2 3 500, 600 2 3 700, 800 2 3 1000, 1200 2 3 600 Type Current [A] Poles Voltage [V] AC DC Interrupting capacity [kA] AC V AC V 240 480 250 BU2EHC 15,20,25,30,35,40,45, 2 480 18 BU3EHC 50,60,70,80,90,100 3 600 18 14 10 BU2FHC BU3FHC 15,20,25,30,35,40,50, 2 3 480 600 65 25 20 65 25 20 42 25 20 BU-KSB BU-LSB BU-MSB BU-NSB BU high-performance BU-JHB BU-KHB BU-LHB BU-MHB BU-NHB Poles 600 250 250 250 - Interrupting capacity [kA] AC [V] DC [V] 600 480 240 250 22 30 50 10 22 30 50 10 22 30 50 10 22 30 50 - 125/250 10 E90584 10 10 - 600 - 22 30 50 - - 600 25 35 65 25 35 65 25 35 65 600 250 250 250 - 25 42 65 10 10 10 - 10 10 10 - 600 - 25 42 65 - - 600 600 600 600 UL File No. z BU C series Series UL approved BU-UL/CE certificate Series 60,70,80,90,100 125,150 32 250 14 10 UL File No. E90584 Manual Motor Starters Series Type Standard BM3 Series Thermal current setting range Operational current le [A] BM3RSB 0.1-0.16 0.16-0.25 0.25-0.4 0.4-0.63 0.63-1 1-1.6 1.6-2.5 2.5-4 4-6.3 6.3-10 9-13 11-16 14-20 19-25 24-32 BM3RHB 0.1-0.16 0.16-0.25 0.25-0.4 0.4-0.63 0.63-1 1-1.6 1.6-2.5 2.5-4 4-6.3 6.3-10 9-13 11-16 14-20 19-25 24-32 BM3VSB 6.3-10 BM3VHB 9-13 11-16 14-20 19-25 24-32 28-40 35-50 45-63 Max. motor capacity and full-load current Group Installation 3-phase [HP] Rated breaking capacity [kA] UL File No. AC200208V AC220240V AC440480V AC550600V AC240V AC480V AC600V Max. fuse /MCCB Rated current [A] 1/4 1/2 3/4 1 2 3 3 5 7 1/2 10 1/4 1/2 3/4 1 2 3 3 5 7 1/2 10 2 3 3 5 7 1/2 10 10 15 20 1/3 1/2 3/4 1 1/2 3 3 5 5 7 1/2 10 1/3 1/2 3/4 1 1/2 3 3 5 5 7 1/2 10 3 3 5 5 7 1/2 10 10 15 20 1/2 3/4 1 2 3 5 7 1/2 10 10 15 20 1/2 3/4 1 2 3 5 7 1/2 10 10 15 20 5 7 1/2 10 10 15 20 30 30 40 1/2 3/4 1 1/2 3 5 7 1/2 10 10 15 20 30 1/2 3/4 1 1/2 3 5 7 1/2 10 10 15 20 30 7 1/2 10 10 15 20 30 30 40 60 100 100 100 100 100 100 100 100 100 100 100 100 50 50 50 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 50 50 50 50 50 50 50 50 50 22 22 22 22 22 22 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 (22) 50 (22) 50 (22) 50 (22) 50 (22) 50 (22) 50 (22) 50 (22) 50 (22) 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 600 600 600 600 600 600 600 600 600 E163944 (UL508) Note 1: The figures in parentheses ( ) are for BM3VSB. Circuit Protector Series Type Standard E CP3 E V CP3 V T CP3 T F CP3 F P CP3 P B CP5 B Voltage [V] Current [A] Interrupting capacity (250V AC) Internal circuit UL File No. 250V AC 60V DC 0.05-30A 1,000A E96846 E83461 (Switch type) 240V AC 60V DC 240V AC 60V DC 240V AC 60V DC 240V AC 60V DC 0.1-30A 1,000A Series type Shunt type Relay type (current tripping) Switch type Series type 0.1-30A 2,500A Series type 0.3-25A 1,000A Series type 0.3-50A 1,500A Series type 33 E96846 Super-rapid Fuses Type Standard CR2LS-10/UL CR2LS-20/UL CR2LS-30/UL CR2LS-50/UL CR2LS-75/UL CR2LS-100/UL CR2L-150/UL CR2L-200/UL CR2L-260/UL CR2L-350/UL CR2L-400/UL CR6L-20/UL CR6L-30/UL CR6L-50/UL CR6L-75/UL CR6L-100/UL CR6L-150/UL CR6L-200/UL CR6L-300/UL Rating Voltage [V] 250V AC, 400V DC UL File No. Current [A] Interrupting capacity 10kA (pf0.8) at 250V AC 10kA (time constant: 2.0ms) at 400V DC 10 20 30 50 75 100 150 200 260 350 400 20 30 50 75 100 150 200 300 600V AC, 600V DC 600V AC 600V AC, 600V DC 50kA (pf0.8) at 600V AC 10kA (time constant: 1.0ms) at 600V DC 100kA (pf0.8) at 600V AC 10kA (time constant: 3.0ms) at 600V DC E92312 E92312 50kA (pf0.8) at 600V AC 10kA (time constant: 1.0ms) at 600V DC Pushbuttons, Selector Switches, Pilot Lights, Buzzers Command switches a. Illuminated pushbutton switches Bezel Round bezel Operator Flush round head Extended round head Mushroom head (40mm dia.) Mushroom head (29mm dia.) Extended with transparent full guard (24mm dia.) Extended with full guard (24mm dia.) Extended with full guard (24mm dia. with openings) Push-lock, turn-reset (40mm dia. with white arrow) Push-pull Square Flush square head bezel Extended square head Flush round head Extended round head Mushroom head (29mm dia.) Type AR22 Momentary AR22F0L AR22E0L AR22M0L AR22M4L AR22G4L AR22G1L AR22G2L UL File No. Alternate AR22F5L AR22E5L AR22M5L AR22M9L AR22G9L AR30 Momentary AR30E0L AR30G4L AR22G6L AR22G7L AR30G3L AR30G2L AR22V5L (Returning method : turn-reset) AR22F0M AR22E0M AR22F0P AR22E0P AR22M4P AR22F5M AR22E5M AR22F5P AR22E5P - 34 Alternate AR30E5L AR30G9L AM22 Momentary AM22F0L AM22E0L AM22M0L AM22M4L AM22G4L Alternate AM22F5L AM22E5L AM22M5L AM22M9L AM22G9L AR30G8L AR30G7L AM22G2L AM22G7L - - - - - - AR30V5L (Returning method : turn-reset) AR30Q7L (Returning method : automatic return) - E44592 b. Pushbutton switches Bezel Operator Round bezel Flush round head Extended round head Mushroom head (40mm dia.) Mushroom head (29mm dia.) Flush with full guard (24mm dia.) Extended with full guard (24mm dia.) Extended with half guard Pin lock Mushroom head with full guard (40mm dia.) Mushroom head with full guard (35mm dia. metal nut) Pushbutton with selector ring(2-position) Pushbutton with selector ring(2-position) Pushbutton with selector ring(2-position) Pushbutton with selector ring(2-position) Giant head Giant head with guard Giant head with full guard Giant head with full guard Push, turn-lock Push-lock, turn-reset (40mm dia. with white arrow) Pushbutton with emergency operating cap Square Flush square head bezel Extended square head Flush round head Extended round head Mushroom head (29mm dia.) Type AR22 Momentary AR22F0R AR22E0R AR22M0R AR22M4R AR22G2R AR22G3R AR22G0R AR22M3R Alternate AR22F5R AR22E5R AR22M5R AR22M9R AR22G8R AR22G5R - AR30 Momentary AR30F0R AR30E0R AR30M0R AR30M4R AR30G1R AR30G0R AR30GPR AR30M3R UL File No. - - AM22 Momentary AM22F0R AM22E0R AM22M0R AM22M4R AM22G3R AM22M3R Alternate AM22F5R E44592 AM22E5R AM22M5R AM22G8R AM22M8R AR30GSR - - - AR22S1R AR22S2R AR22S3R AR22S6R AR22V5R (Returning method : turn-reset) AR22F0S AR22F5S AR22E0S AR22E5S AR22F0Y AR22F5Y AR22E0Y AR22E5Y AR22M4Y - AR30S1R AR30S2R AR30S3R AR30S6R AR30B0R AR30B1R AR30B2R AR30B3R AR30N0R AR30V5R (Returning method : turn-reset) AR30FVR - - - - - Type AR22 With white arrow AR22VSR AR22V0R - No white arrow AR22V4R AR22V2R - AR30 With white arrow AR30V0R AR30V1R No white arrow AR30V2R - AM22 With white arrow AM22VSE AM22V0E - No white arrow - - AR22V7R - - - - - AR22Q2R - AR30Q2R - - - - - - - Type AR22 With white arrow AR22VSL AR22V0L No white arrow AR22V2L AR30 With white arrow AR30V0L No white arrow AR30V2L AM22 With white arrow AM22VSF AM22V0F No white arrow - AR22VDL AR22VAL - - AM22VDF - - - - - - Alternate AR30F5R AR30E5R AR30M5R AR30G6R AR30G5R - c. Emergency stop pushbutton switches Bezel Round bezel Operator Push-lock, turn-reset (29mm dia.) Push-lock, turn-reset (40mm dia.) Push-lock, turn-reset (65mm dia.) Key-release push-lock, turn-reset (40mm dia.) Push-lock, pull-reset (35mm dia.) UL File No. E44592 E44592 Unibody push-lock, turn-reset (40mm dia.) AR22VGE d. Emergency stop illuminated pushbutton switches Bezel Round bezel Operator Push-lock, turn-reset (29mm dia.) Push-lock, turn-reset (40mm dia.) Push-lock, turn-reset (40mm dia. Transparent in all colors) UL File No. E44592 E44592 Unibody push-lock, turn-reset (40mm dia.) AR22VGF 35 e. Pilot lights Bezel Round bezel Square bezel Note 1. Note 2. Lens Type DR22 Dome DR22D0L Extended round DR22E3L Faceted DR22K0L Flush square DR22F3M Flush square (Transparent lens) DR22F4M Flush square (12mm high frame) DR22F5M Extended square DR22E3M Flush rectangular DR22E3N Flush rectangular (Transparent lens) Flush square large type (Transparent lens) Extended round DR22E3P With resistor unit and resistor types : Not approved * LED 12V AC type : Not approved UL File No. DR30 DR30D0L DR30E3L DR30K0L DR30F4M* DR30F4N* DR30M4M* - DM22 DM22D0L DM22E3L DM22K0L - E44592 f. Selector switches Bezel Operator Round bezel Knob Lever Cylindrical knob Key Key (long durability) Square Knob bezel Lever Cylindrical knob Key Type AR22 Standard Type AR22PR AR22WR AR22RR AR22JR AR22JAR AR22PY AR22WY AR22RY AR22JY UL File No. AR30 Control Standard type type AR22PCR AR30PR AR22WCR AR30WR AR22RCR AR22JCR AR30JR AR30JAR AR22PCY AR22WCY AR22RCY AR22JCY - AM22 Control Standard type type AR30PCR AM22PR AR30WCR AM22WR AR30JCR AM22JR - Control type AM22PCR E44592 AM22WCR AM22JCR - g. Illuminated selector switches Bezel Operator Round Knob bezel Square Knob bezel Type AR22 Standard type AR30 Standard type AM22 Standard type UL File No. AR22PL AR30PL AM22PL AR22PP - - Type AR22 Manual return AR22A0 AR22A1 AR22A2 AR30 Manual return AR30A0 AR30A1 AR30A2 AM22 Manual return - E44592 h. Joy stick selector switches (Lever switches) Bezel Round bezel Handle Ball type (without lock) Ball type (with lock) Rubber cap type (without lock) UL File No. Spring return AR22A5 AR22A6 AR22A7 Spring return AR30A5 AR30A6 AR30A7 Spring return - E44592 i. Buzzers Bezel Round bezel Sound Electronic sound Electronic sound (economy) Electronic sound (IP54) Note: 6V AC, 110V DC types : Not approved Type DR22 Standard type DR22B5 DR22B8 UL File No. DR30 Standard type DR30B5 DR30B6 DR30B8 36 DM22 Standard type - E44592 j. Contact ratings AC (COS O=0.35) Contact rated code A600 B300 (AR22VG) 120V Making current 60A 30A Breaking current 6.0A 3.0A 240V Making current 30A 15A Breaking current 3.0A 1.5A 480V Making current 15A - 600V Making current 12A - Breaking current 1.5A - Breaking current 1.2A - DC T0.95 = 6P (Max. 300ms) Description Contact rated code Making current * Breaking current 125V 250V P600 1.1A 0.55A Illuminated pushbutton switch Pushbutton (With selector ring type: AR22S2R, AR30S2R only) Emergency stop pushbutton switch Emergency stop illuminated pushbutton switch Q300 0.55A 0.27A (Except the overlap contact types) (AR22VG) Overlap contact types of products shown above Q600 0.55A 0.27A Pushbutton (With selector ring type: AR22S1R, AR22S6R, AR30S1R and AR30S6R only) Selector switch (2-position only, except the overlap contact types) Illuminated selector switch (2-position only, except the overlap contact types) Pushbutton R300 0.22A 0.11A (With selector ring type: AR22S3R, AR30S3R only) Selector switch (2-pos./overlap contact type, 3-, 4-, 5-pos. Type) Illuminated selector switch (2-pos./overlap contact type, 3-pos. Type) Note : Joy stick selector switches (Lever switches): 250V AC, 5A (Res. load) 125V DC, 0.2A 24V DC, 1A (Res. load) 301V - 600V 0.2A 0.1A - k. Lamp ratings Full-voltage (without transformer) With transformer LED lamp Incandescent lamp Max. 24V AC/DC Max. 30V AC/DC Max. 550V AC (Short-body type: Max. 220V AC) 37 Neon lamp (AR22VGF type) Max. 240V AC - Command switches a. Pushbutton switches Name Pushbutton switches Wobble stick switch Pushbutton with selector ring (2-position) Mechanically interlocked pushbutton switches Type AH25 E E5 F F5 G G1 G5 G6 M M5 SE SE5 SF SF5 U S1 S2 S3 S4 S5 S6 F5/F F5/E F5/M E5/E E5/M M5/M Specification Contact arrangement 1NO 1NC 1NO+1NC 2NO 2NC 2NO+2NC 3NO, 3NC 3NO+3NC 4NO, 4NC 4NO+4NC (1NO+1NC or 2NO+2NC for E5, F5, G5, G6, M5, SF5 and SE5 types) UL File No. Color Green Red Black Dark green Yellow White Orange Blue E44592 2NO+2NC 1NO+1NC + 1NO+1NC b. Selector switches Name Selector switches (2-position) Selector switches (3-position) Type AH25 J0 J2 P0 P2 SJ2 SP2 J3 J5 P1 P3 P5 P6 J6 PC SJ3 SP3 Specification Contact arrangement 1NO, 1NC 1NO+1NC 2NO, 2NC 2NO+2NC 3NO, 3NC 3NO+3NC 4NO, 4NC 4NO+4NC (2NO+2NC for P1 and PC types) Type AH25 L L1 L2 L3 L4 L5 L6 L7 L8 SL SL1 SL5 SL6 Specification Contact arrangement Without transformer 1NO, 1NC, 1NO+1NC 2NO, 2NC, 2NO+2NC 3NO, 3NC, 3NO+3NC 4NO, 4NC, 4NO+4NC With transformer 1NO, 1NC, 1NO+1NC 2NO, 2NC, 2NO+2NC (1NO+1NC or 2NO+2NC for L5, L6, L7, L8, SL5 and SL6 types) UL File No. Color (For P type) Black Green Red E44592 c. Illuminated pushbutton switches Name Illuminated pushbutton switches 38 UL File No. Color Green Red White Blue (except LED) Yellow Orange E44592 d. Pilot lights Name Type AH25 ZK ZM ZN ZS Pilot lights Specification Lamp voltage Without transformer Incandescent Max. 30V AC/DC LED Max. 24V AC/DC With transformer Max. 600V AC UL File No. Color Green Red White Blue (except LED) Yellow Orange E44592 e. Contact ratings Voltage [V] Application UL Continuous current AC [A] Make [A] 60 10 CSA 110-120 120 220-240 240 440-480 480 550-600 600 Voltage [V] Application UL 30 3.0 15 1.5 12 1.2 DC Make and break currents [A] 1.1 CSA 115-125 115 125 230-250 0.55 Note: AH25-J3, -J5, -P3 and -P1 types cannot be used in DC circuit. 39 Break [A] 6.0 Command switches a. AH164/AH165 series Name Type Specification AH164 AH165 Contact Color arrangement Pushbutton switches E E 1NO+1NC Green SF SF 2NO+2NC Red TF TF 3NO+3NC Black TGF TGF Yellow M M White SM SM Orange TM TM Blue *1 V *1 V1 E5 SF5 TF5 TGF5 M5 SM5 TM5 Illuminated L pushbutton switches SL TL TGL L5 SL5 TL5 TGL5 Emergency stop pushbutton switches Selector switches P0 P1 P2 P3 P6 P7 SP0 SP1 SP2 SP3 SP6 SP7 J0 J1 J2 J3 J6 J7 SJ0 SJ1 SJ2 SJ3 SJ6 SJ7 Pilot lights Z ZS ZT Buzzers TX2 Numerical indicators TC4 Contact Indicator E44592 250V AC5A max, 24V DC1A 125V DC0.2A, Resistive load (Cannot be used when potential differs in the same contact or unit) E5 SF5 TF5 TGF5 M5 SM5 TM5 L SL TL TGL - Without transformer For incandescent lamps (120V AC/DC max 1.2W) 6V, 14V, 28V, 48V, AC/DC *3 For LED lamps 5V, 6V, 12V, 24V DC For neon lamps 110V, 120V, 220V AC - With transformer For incandescent/LED lamps: 110V, 220V AC 1NO+1NC 2NO+2NC 3NO+3NC Green Red White Yellow Orange Blue V5 V6 P0 P1 P2 P3 P6 P7 SP0 SP1 SP2 SP3 SP6 SP7 J0 J1 J2 J3 J6 J7 SJ0 SJ1 SJ2 SJ3 SJ6 SJ7 *2 RJM2 *2 JM2 Z ZS ZT ZM ZT1 NC NC 1NO+1NC 2NO+2NC 3NO+3NC Red - Green Red White Yellow Orange Blue - X TC4 - Black - - L5 SL5 TL5 TGL5 Knob color: black; key type: A, B, C, D, E and F - - Without transformer For incandescent lamps (except ZM types) (120V AC-DC max 1.2W) 6V, 14V, 28V, 48V, AC/DC 6.3V, 18V, 24V, 30V AC/DC (ZT1 types) *3 For LED lamps 5V, 6V, 12V 24V DC 6V DC, 12V, 15V, 24V AC/DC (ZT1 types) 12V, 24V DC (ZM types) For neon lamps 110V, 120V, 220V AC - With transformer For incandescent/LED lamps: 110V, 220V AC 6V, 12 - 24V, 35 - 48V AC/DC 24V DC *1 Contact arrangement is 1NC or 2NC; button color is red. Contact arrangement is 1NO+1NC or 2NO+2NC. *3 The spot LED type and 2-color LED type have not been approved. *2 40 UL File No. b. AH165-2/AH225/AG225/AH16P/AH22P/AH16P-2 series Name Type AH165-2 Pushbutton F, E, SF, SE, SCE, switches M, YM, S2, YS2, V, YV, SG *1 F5, E5, SF5, SE5, SCE5, SG5 *1 F5, E5 F5, E5, CE5 FL, EL, SFL, SEL, SCL, ML, YML, VL, YVL, SGL *1 FL5, EL5, SFL5, SEL5, SCL5, SGL5 *1 P YP H SH J YJ SP *1 SJ *1 FL, EL ML, VL FL, EL, CL, ML, VL P H J P H J P SP H J SJ P YP H SH J YJ P H J Knob color: black; 1NO+1NC key type: A, B, C, D, 2NO+2NC E and F 3NO+3NC (Items for P board: 3NO + 3NC not included) Illuminated selector switches PL PL PL - - - 1NO+1NC 2NO+2NC Green Red White Yellow Orange Bule (LED lamps are for AH-165-2 type only.) - Pilot lights Z ZE SZ SZE - - ZT ZS Z Z ZE SZ SZE - - Green Red White Yellow Orange Bule - Selector switches *1 AH16P-2 F, E, SF, SE, SCE M, YM, S2, YS2 V, YV TF5, SF5, F5, E5 SF5, SE5, E5, SCE5 TGF5, M5, SM5, TM5 TL, SL, L, TGL AH22P F, E, M, S2, V Contact AG225 F, E CE M, S2, V Illuminated pushbutton switches AH16P TF, SF, E, TGF, M, SM TM Specification Contact arrangement 1NO+1NC 2NO+2NC 3NO+3NC (Items for P board: 3NO + 3NC not included) AH225 F, E M, S2, V F5, E5 FL, EL, FL, EL SFL, SEL, ML, VL SCL ML, YML VL, YVL 1NO+1NC 2NO+2NC 3NO+3NC (Items for P board: 3NO + 3NC not included) FL5, EL5 FL5, EL5 TL5, SL5, FL5, EL5, FL5, EL5 SFL5, CL5 L5, SEL5, TGL5 SCL5 Color Green Red Black Yellow White Orange Blue Indicator UL File No. E44592 250V AC5A max 24V DC1A 125V DC0.2A Resistive load (Cannot be used when potential differs within the same contact or unit) For incandescent lamps 120V AC/DC max 1.2W 6V, 14V, 28V, 48V AC/DC For LED lamps 5V, 6V, 12V, 24V DC For neon lamps (Except for items for P board) 110V, 120V, 220V AC Green Red White Yellow Orange Blue (LED lamps are for AH165-2, AH16P and AH16P-2 types only.) For incandescent lamps 120V AC/DC max 1.2W 6V, 14V, 28V, 48V AC/DC For LED lamps 5V, 6V, 12V, 24V DC For incandescent lamps 120V AC/DC max 1.2W 6V, 14V, 28V, 48V AC/DC For LED lamps 5V, 6V, 12V, 24V DC For neon lamps (Except for items for P board) 110V, 120V, 220V AC Certified contact configuration: 1NO + 1NC only c. AG22/AG23 series LED Pilot lights Incandescent LED Illuminated pushbutton switches Type AG22 Incandescent Name LA, LB L5A, L5B Contact portion L1, L2 L51, L52 Illuminating portion LA 3, LB 3 Specification Contact arrangement LA, LB, LC, LD, LE, LF AG22; L5A, L5B, L5C, L5D, 1NO+1NC L5E, L5F 2NO+2NC AG23 ZA, ZB Contact portion L1, L2, L3, L4 L51, L52, L53, L54 Illuminating portion LA 3,LB 3, LC 3, LD 3, LE 3, LF 3 ZA, ZB, ZC, ZD, ZE, ZF Case Z6 Case Z6 AG23; 1NO+1NC 2NO+2NC 3NO+3NC 4NO+4NC - Contact Indicator Green Red White Yellow Orange Blue (except LED) 250V AC5A max 24V DC 1A 125V DC 0.2A Resistive load (Cannot be used when potential differs within the same contact or unit) For incandescent E44592 lamps 28V AC/DC max 1.2W For LED lamps max 24V DC - Illuminating portion Illuminating portion ZA 3, ZB 3 ZA 3, ZB 3, ZC 3, ZD 3, ZE 3, ZF 3 41 UL File No. Color Command switches a. Illuminated pushbutton switch, Pushbutton switch Bezel Square bezel Operator Flush square head Flush with full guard Pushbutton with selector ring (2-position, 24mm dia.) Type Illuminated pushbutton switch Momentary Alternate AG28F0M AG28F5M AG28G2M AG28G7M - UL File No. Pushbutton switch Momentary Alternate AG28F0S AG28F5S AG29G2S AG28G7S AG28S2Y - E44592 b. Selector switch, Illuminated pushbutton switch, Pilot light Bezel Square bezel Operator Knob Flush square head Type Selector switch Non-illuminated type AG28PY - UL File No. Pilot light Illuminated type AG28PP - DG28F3M E44592 c. Ratings Please refer to "j. Contact ratings" and "k. Lamp ratings" for command switches (AR22, DR22, AR30, and DR30 series) in the table above. 42 Control Relays Control relays Standard Type Contact arrangement Voltage Resistive load HH52 HH52 W 2(NO+NC) single contact, bifurcated contact 120V AC 240V AC 30V DC 120V DC 120V AC 240V AC 30V DC 120V DC 120V AC 240V AC 30V DC 120V DC 120V AC 240V AC 30V DC 120V DC 120V AC 240V AC 30V DC 120V DC 120V AC 240V AC 30V DC 120V DC 120V AC 240V AC 30V DC 120V DC 120V AC 240V AC 30V DC 120V DC 120V AC 240V AC 30V DC 120V DC 120V AC 240V AC 30V DC 120V DC 120V AC 240V AC 30V DC 120V DC 5A 5A 5A 0.3A 7A 7A 7A 0.3A 5A 5A 5A 0.3A 3A 3A 3A 0.3A 5A 5A 5A 0.3A 3A 3A 3A 0.2A 10A 10A 8A 0.3A 5A 5A 5A 0.3A 10A 10A 8A 0.3A 6A 6A 6A 0.5A 6A 6A 6A 0.5A Resistive load HH52 U HH53 HH54 HH54 U HH54 W HH62 HH62 W 2(NO+NC) high capacity single contact 3(NO+NC) single contact 4(NO+NC) single contact 4(NO+NC) high capacity single contact 4(NO+NC) bifurcated contact 2(NO+NC) single contact 2(NO+NC) bifurcated contact HH63 HH64 3(NO+NC) single contact 4(NO+NC) single contact HH22P -UL 2(NO+NC) single contact, bifurcated contact HH23P -UL 3(NO+NC) single contact, bifurcated contact Inductive load Continuous UL File No. current 1.5A 5A E42419 2A (15ms) 0.2A (15ms) 1.5A 7A E42419 2A (15ms) 0.2A (15ms) 1.5A 5A E42419 2A (15ms) 0.2A (15ms) 1A 3A E42419 2A (15ms) 0.2A (15ms) 1A 5A E42419 2A (15ms) 0.2A (15ms) 1A 3A E42419 2A (15ms) 0.2A (15ms) 1.5A 10A E42419 2A (15ms) 0.2A (15ms) 1.5A 7A E42419 2A (15ms) 0.2A (15ms) 1.5A 10A E142976 (HH63 ) E142975 (HH64 ) 2A (15ms) 0.2A (15ms) 2A 6A E42419 3A (15ms) 0.3A (15ms) 2A 6A E42419 3A (15ms) 0.3A (15ms) : P, B or S (mounting method) Card relays, terminal relays Standard Type Contact arrangement Voltage RT11-UL, 17-UL 1(NO+NC) RB104, 105 1NO RS4 RS6N (-P) RS16 (-P) 4-pole 6-pole 16-pole 120V AC 240V AC 30V DC 120V DC 120V AC 240V AC 30V DC 120V DC 120V AC 240V AC 30V DC 120V DC Inductive load Continuous current 3A 3A 1A 3A 3A 2A (7ms) 0.3A 0.2A (7ms) 1A 5A 5A 5A 2A (15ms) 0.5A 0.2A (15ms) 1A 5A (2A for RS6N 5A (2A for RS6N and RS16) and RS16) 5A (2A for RS6N 2A (15ms) and RS16) 0.5A 0.2A (15ms) 43 UL File No. E83461 E44592 E44592 Sockets Standard Type TP58 TP58B TP58R2 TP58X2 TP58X1 TP511 TP511B TP511R2 TP511X2 TP514 TP514B TP514R2 TP514X2 TP514X1 TP68 TP68B TP68R TP68X2 TP611X2 TP614X2 8GB-UL 11GB-UL Specification Soldering PC board Wire wrap Rail mounting (M3.5) Rail mounting (M3) Soldering PC board Wire wrap Rail mounting (M3.5) Soldering PC board Wire wrap Rail mounting (M3.5) Rail mounting (M3) Soldering PC board Wire wrap Rail mounting (M3.5) Rail mounting (M3.5) Rail mounting (M3.5) Soldering Soldering Used with HH52 UL File No. E90265 HH53 E90265 HH54 E90265 HH62 E42419 HH63 HH64 HH22 HH23 E142976 E142975 E42419 Timers Type and rating Standard Type Operation Mounting Indication Surface/ flush MS4SA On-delay Flicker One-shot momentary action Signal off-delay On-delay MS4SC On-delay MS4SR Repeat MS4SF MS4SM Power-on Time up Power-on Time up Power-on Time up Contact Control output arrangement See the UL Time-limit approved 2(NO+NC) type list shown at page 45 Time-limit 2(NO+NC) Time-limit 1(NO+NC) + instantaneous 1(NO+NC) Time-limit 2(NO+NC) Time-limit 2(NO+NC) Time-limit 1(NO+NC) + instantaneous reset Off-delay Power-on ON Power-on MS4SF-R Off-delay Power-on MS4SY contact input contact output Time-limit 1NO ( ) 1NO () instantaneous 1NO Power-on Time-limit 1(NO+NC) - Input voltage 100 to 240V AC 50/60Hz 24V AC/DC 48 to 127V DC Power consumption Approx. 10VA for AC type. Approx. 1W for DC type. Timing range From 0.6 seconds to 60 hours, 16 changeable ranges Full scale 6 12 30 60 Unit x 0.1s 0.05 to 0.6s 0.1 to 1.2s 0.25 to 3s 0.5 to 6s 100 to 240V AC 50/60Hz 24V AC/DC 50/60Hz 48 to 127V DC Approx. 1VA for AC type. Full scale Approx. 1W for 0.6 DC type. 1.2 100 to 240V AC 50/60Hz Approx. 10VA for AC type. s 0.5 to 6s 1 to 12s 2.5 to 30s 5 to 60s Electrically reset On-delay Approx. 10VA for AC type. Power-on Time up Power-on Time up Time-limit 2(NO+NC) Time-limit 4(NO+NC) 240V AC 3A (Resistive load) 8 operation modes Surface/ flush - Time-limit 1(NO+NC) 250V AC 5A (Resistive load) On-delay Time up Time-limit 1(NO+NC) 220V AC 1A (Resistive load) ST7P-2 On-delay Surface Full scale 6 12 60 120 Timing range ( 0.5 to 6s 1 to 12s 5 to 60s 10 to 120s ST7P-4 On-delay Surface MD4E MS7S1 Surface Note: For connection, use a socket applicable to the object type. 44 Full scale 6 12 60 120 Unit s 0.5 to 6s 1 to 12s 5 to 60s 10 to 120s ) 0.1s min 0.5 to 6min 1 to 12min 5 to 60min 10 to 120min 0.06 to 0.5s 0.25 to 3min 0.1 to 1s 1 to 10min 0.3 to 3s 2 to 30min 0.4 to 5s 4 to 60min 1 to 10s 0.2 to 2h 2 to 30s 0.5 to 6h 4 to 60s 1 to 12h 0.001s to 9999h 100 to 240V AC 100V AC 9.999s 99min 59s approx. 1.1VA 50/60Hz 99.99s 99h 59min 200V AV 24V AC/DC 999.9s 9999h approx. 1.5VA 50/60Hz 9999s 24V DC approx. 0.8W 24V AC approx. 1.1VA 0.5 to 3s Approx. 2VA 0.2 to 1.2s 100/200V AC 1 to 6s 2 to 12s for AC type. 110/220V AC 5 to 30s 10 to 60s Approx. 1W 50/60Hz 0.5 to 3min 1 to 6min for DC type. Terminal 2 to 12min switchover 5 to 30min 24V AC, 24V DC 10 to 60min 100V AC 200V AC 24V DC h 0.5 to 6h 1 to 12h 2.5 to 30h 5 to 60h Unit Second-scale Minute-scale sec min 0.05 to 0.6s 0.05 to 0.6min 0.1 to 1.2s 0.1 to 1.2min 6 0.5 to 6s 0.5 to 6min 12 1 to 12s 1 to 12min Second-scale: from 0.6 to 12 seconds, 4 changeable ranges Minute-scale: from 0.6 to 12 minutes, changeable ranges switching time 0.05s MS4SE min 0.5 to 6min 1 to 12min 2.5 to 30min 5 to 60min 100V AC approx. 1.2VA 200V AV approx. 1.5VA 24V DC approx. 1.1W 0.25s hrs 0.5 to 6hrs 1 to 12hrs 5 to 60hrs 10 to 120hrs 0.5s x 10 h 5 to 60h 10 to 120h 50 to 600h 100 to 1200h Supertimer Standard Type MS4SM MS4SA MS4SC MS4SR MS4SF MS4SF-R MS4SY MS4SE MS7S1 ST7P-2 ST7P-4 Operation On-delay Flicker One-shot momentary action Signal off-delay On-delay On-delay Repeat Off-delay Off-delay Star-delta Electrically reset off-delay On-delay On-delay On-delay Control output Contact rating: 5A, 250V AC (resistive load) UL File No. E44592 Contact rating: 5A, 240V AC (resistive load) Contact rating: 5A, 250V AC (resistive load) Contact rating: 3A, 250V AC (resistive load) Contact rating: 5A, 250V AC (resistive load) Contact rating: 5A, 240V AC (resistive load) Contact rating: 5A, 250V AC (resistive load) Contact rating: 1A, 220V AC (resistive load) Contact rating: 3A, 240V AC (resistive load) Digital timer Standard Type MD4E Operation 8 modes Control output Contact rating: 5A, 250V AC (resistive load) Type Standard TP411X Specification Rail mounting, screw terminal (11-pin) TP411SBA ATX2NS TP48X Flush mounting, screw terminal (11-pin) Flush mounting, solder terminal (11-pin) Rail mounting, screw terminal (8-pin) TP48SB ATX1NS TP88X1 TP88X2 TP88 TP88R2 TP88B TP814X1 TP814X2 TP814 TP814R2 TP814B Flush mounting, screw terminal (8-pin) Flush mounting, solder terminal (8-pin) Rail mounting, screw terminal (8-pin) UL File No. E42419 Sockets Standard L Surface mounting, solder terminal (8-pin) Surface mounting, wire wrap (8-pin) Surface mounting, PC board (8-pin) Rail mounting, screw terminal (11-pin) Surface mounting, solder terminal (11-pin) Surface mounting, wire wrap (11-pin) Surface mounting, PC board (11-pin) 45 Used with MS4SM UL File No. E195744 MS4SA MS4SC MS4SF MS4SY MS4SE MS4SR MD4E E90265 ST7P-2 E90265 ST7P-4 E90265 Terminal Blocks High-strength terminal blocks Standard L No. of poles 3 Type SKT14A-3C SKT38A-3C SKT60A-3C SKT100A-3C Connecting wire size 14-8AWG-Cu 14-6AWG-Cu 12-4AWG-Cu 12-2AWG-Cu Rated current [A] 50 65 85 115 UL File No. E45457 Rated current [A] 15 19 22 27 35 40 68 19 20 30 40 75 95 150 200 300 400 550 Connecting wire size 20-16AWG-Cu 16-14AWG-Cu UL File No. E45457 8-6AWG-Cu 18-14AWG-Cu 20-14AWG-Cu 18-12AWG-Cu 18-10AWG-Cu 10-6AWG-Cu 8-4AWG-Cu 4-2/0AWG-Cu 2-4/0AWG-Cu 2/0-300AWG-Cu 4/0-350AWG-Cu 300-600AWG-Cu Rated current [A] 1 Connecting wire size 22-16AWG-Cu Combination terminal blocks Standard Type LT2F-010 LT2F-020 Withstand voltage [V] 600 LT2F-030 LT2F-040 LT2F-080 LT2F-020W LT2E-020 LT2E-030 LT2E-040 LT2E-080 LT2E-090 LT2E-150 LT2E-200 LT2E-300 LT2E-400 LT2E-600 14-10AWG-Cu 12-10AWG-Cu Relaying connector terminal block Standard Type LP5W-20H5 LP5W-24H1 LP5W-26H5 LP5W-34H5 LP5W-40H1 LP5W-40H5 LP5W-50H5 Withstand voltage [V] 125 46 UL File No. E45457 Limit Switches AL type a. Type Standard Series Type General- AL-N11 purpose AL-N21 AL-N31 AL-P11 AL-P21 AL-P31 AL-F11 AL-S11 AL-S21 AL-W11 AL-Y11 AL-Y21 AL-Y31 Small AL-SN11 AL-SN21 AL-SN31 AL-SP11 AL-SP21 AL-SK11 AL-SK21 AL-SS11 UL UL UL UL UL UL UL UL UL UL UL UL UL UL UL UL UL UL UL UL UL Name of actuator Ratings Roller lever type Adjustable roller lever type Rod lever type Push plunger type Roller plunger type Ball plunger type Fork roller lever type DC Make and break currents [A] Coil spring type Voltage Spring rod type Load type Wire spring type Continuous current 5A Side push plunger type AC Contact current code Voltage Side roller plunger type B300 120V Side ball plunger type 240V Roller lever type Adjustable roller lever type Rod lever type Push plunger type Roller plunger type Roller arm type Reverse roller arm type Spring rod type Note: Symbols for lamp voltage and type are filled in UL File No. E44592 30V 125V Resistive load 5 Make 30A 15A 0.4 250V 0.2 Break 3A 1.5A . Lamp type Symbol 1 2 Type Neon lamp LED Lamp voltage Symbol Voltage A B E H 5 to 8V 10 to 15V 18 to 24V 110 to 220V Manufacture Neon lamp LED - b. Performance Item Insulation resistance Withstand voltage *1 Vibration resistance *1 Impact resistance Permissible operation cycle Temperature rise Life Mechanical Ambient temperature Ambient humidity General-purpose (AL) Small (AL-S) Min. 100M (by 500V DC megger) between non-continuous terminals or between each terminal and uncharged metal part. 1500V between each terminal and uncharged metal part Double amplitude 1.5mm, 10 to 55 Hz 300 m/s2 120 cycle/min. 50C or less 30 million cycles (N1 type) 10 million cycles 10 million cycles (other types) -10C to +80C 95% RH or less *1 Except coil spring, spring rod and wire spring types Contact reliability: It was confirmed that these switches work without problem under the circuit conditions of 5V AC/DC and 2mA. However, operation ranges may change depending on environmental conditions and load types. For details, contact Fuji Electric. 47 c. Operational characteristics - General-purpose (AL) Type Item Required operating force: OF max. Return force: RF min. Movement before operation: PT min. Movement after operation: OT min. Differential movement: MD max. Overall movement: TT min. *1 *2 AL-N11UL AL-N21UL 900g 50g 12deg. 65deg. 7deg. 75deg. 900g 50g 12deg. 65deg. 7deg. 75deg. *1 AL-N31UL 290g 15g 12deg. 65deg. 7deg. 75deg. *2 AL-P11UL AL-P21UL AL-P31UL AL-F11UL 1500g 820g 2mm 5mm 1mm - 1500g 820g 2mm 5mm 1mm - 1500g 820g 2mm 5mm 1mm - 950g 55deg. 35deg. 9010deg. When lever length is 38 mm When rod lever length is 135 mm Type Item Required operating force: OF max. Return force: RF min. Movement before operation: PT min. Movement after operation: OT min. Differential movement: MD max. AL-Y11UL AL-Y21UL AL-Y31UL AL-S11UL AL-S21UL AL-W11UL 4082g 907g 2.8mm 4mm 1mm 4082g 907g 2.8mm 4mm 1mm 4082g 907g 2.8mm 4mm 1mm 150g 30mm - 150g 30mm - 150g 40mm - - Small (AL-S) Type Item Required operating force: OF max. Return force: RF min. Movement before operation: PT min. Movement after operation: OT min. Differential movement: MD max. *1 AL-SP11UL AL-SP21UL AL-SK11UL AL-SK21UL AL-SN11UL AL-SN21UL AL-SN31UL AL-SS11UL 450g 200g 2mm 4mm 1mm 850g 450g 2mm 3mm 1mm 400g 180g 2.5mm 5mm 1.3mm 400g 180g 2.5mm 5mm 1.3mm 700g 50g 30deg. 40deg. 8deg. 700g 50g 30deg. 40deg. 8deg. 700g 50g 30deg. 40deg. 8deg. 150g 30mm - When lever/rod length is 25 mm 48 *1 *1