FEATURES Small size - High voltage - General purpose
APPLICATIONS Inverters – DC link – AC/DC motor controls – Solar inverters
Operating
Temperature Range -40°C to +85 °C
Capacitance
Tolerance +20% at 120 Hz, 20°C
WVDC 10 16 25 35 50
Surge
Voltage SVDC 13 20 32 44 63
WVDC 10 16 25 35 50
Dissipation
Factor Tan δ .2 .16 .14 .12 .1
2 Minutes
Leakage Current .002CV or 0.4uA,
Whichever is greater
WVDC 10 16 25 35 50
-25°C to
+20°C 3 2 2 2 2
Low
Temperature
Stability
Impedance
Ratio
(120 Hz) -40°C to
+20°C 8 6 4 3 3
2000 hours at 105°C with rated WVDC and ripple current applied
Capacitance Change <20% of initial measured value
Dissipation Factor <150% of maximum specified value
Load Life
Leakage Current >100% of maximum specified value
1000 hours at 105°C with no voltage applied
Capacitance Change <20% initial measured value
Dissipation Factor <200% of maximum specified value
Shelf Life
Leakage Current >100% of maximum specified value
Capacitance Frequency (Hz) Temperature (°C)
uF 50 120 400 1k 10k 50k +85 +70 +60 +30
C<10 .8 1.0 1.3 1.45 1.65 1.7 1.0 1.3 1.5 1.8
Ripple Current
Multipliers 10<C<100 .8 1.0 1.23 1.36 1.48 1.53 1.0 1.3 1.5 1.8
D 5 6.3 8
d 0.5 0.5 0.6
B 0.5 0.5 0.5
L1=L+1.0mm Max. mm
D1=D+B Max.