2000 Series Digital Panel Meters 2100 Series with DIP switch selections and multiple power options. Backlighting Options * * * * * Positive Green Black on Green Background Negative Green Green on Black Background Positive Red Black on Red Background Negative Red Red on Black Background Non-Backlit LCD Black on Grey Background Customize for features that are important to you and rely on industry standards for routine digital PM elements. Applications Telecommunications Water Purification Sewage Treatment Flow Process Desalinization Temperature AC & DC Amps AC & DC Volts You need flexibility. We provide it. We customize our meters to meet your specifications. * Scalable in engineering units * Custom labels for special readouts * User Selectable functions, decimal point, offset, span, process voltage or current, DC voltage * Red or green backlit display You need reliability. The MODUTEC 2000 Series operates in the harshest environments. * Splash and hose proof meeting NEMA 4, NEMA 12, and IPC 55 standards * Resistant to damage with a high impact polycarbonate case * Wide operating temperature ranging from -4F to +140F (-20C to +60C) You need standards. The MODUTEC 2000 Series gives you industry standards designed in. * 1/8 DIN industry standard cut-out and 1 inch depth * Screw terminals * Over range indication * Low cost * The MODUTEC 2100 includes user-friendly dipswitch selection features sales@jewellinstruments.com * www.jewellinstruments.com * 800 638-3771 2000 & 2100 Series Dimensional Drawings ( mm/in ) Panel Cutout Front View 92 3.620 Side View Non-backlit 7.1 .28 96 3.78 .25R MAX (4) .010R 45 1.770 Side View Backlit 7.1 .28 A A 42.9 1.69 48 1.89 42.9 1.69 DC VOLTS Panel Cutout Notes: B 1. For optimum water resistance use cutout height of 43 MM (1.693 Inches). Rear View B Figure A 89.9 3.54 V+ IN HI IN LO DP1 DP2 DP3 AC LO AC HI 2. Panel thickness .81 to 6.35 MM (.032 to .250 Inches). Figure B Input Type Figure A (mm/in) B (mm/in) AC DC Temperature 4-20mA Process Frequency A A A B A 25.1/.99 25.1/.99 25.1/.99 37.8/1.49 25.1/.99 29.2/1.15 29.2/1.15 29.2/1.15 50.8/2.00 29.2/1.15 AC Power 2000 and 2100 Series Specifications Connection for High Current Measurement Display Digits: 3 1/2 digits, 7 segments Backlit LCD (1999) Polarity: Automatic (-) displayed Overload: Three lower digits blank for readings greater than 1999 AC Amps 300:5A User Provided Transformer Supplied With Meter Digit Height: 0.5" (12.7 mm) Decimal Point: Three positions, external selection Performance Conversion Rate: 2.5 per second Common Mode Rejection: 100db 50 Hz-60 Hz1 Tempco: 200 PPM/C typical2 Normal Mode Rejection: 40 db 50Hz-60Hz Zero Adjust: Automatic Warmup: 10 minutes Environment Operating Range: -4F to 140F (-20C to + 60C) Storage Range: -22F to 158F (-30C to + 70C) Power Options 115V +10%, -15% 230V +10%, -15% 10 to 28VDC 10 to 15VDC or 20 to 32VDC 50Hz to 400Hz at 2VA 50Hz to 400Hz at 2VA 150 mA (including backlighting) 150mA (including backlighting) Weight 2 oz. FCC Compliance Complies with the class B Limits of FCC rules and regulations, part 15, sub part J for conducted and radiated emissions. 1 2 except isolated DC powered which is 80 db 50 Hz-60Hz except thermocouple inputs which are .1/ degree zero tempco for selectable process ranges is only .2 count/C Specifications continued on back page. sales@jewellinstruments.com * www.jewellinstruments.com * 800 638-3771 2000 & 2100 Series Connection Drawings Universal Switchable -- Model 2100 AC and DC Inputs (AC and Isolated DC power) Terminal Description Terminal IN+ IN- Signal Input AC Power Low AC Power HI AC Power Input, 115VAC or 230VAC depending on model selected Description V+ 10-28VDC power input IN HI IN LO Signal Input AC Power V+ IN HI IN LO DP1 DP2 DP3 AC LO AC HI (optional) Frequency Input 24V Power GND AC Power Input, 115VAC or 230VAC depending on model selected 12VDC power input 24VDC power input (optional) 12 or 24VDC Power Option 4-20mA Process & Flow Inputs Terminal AC LO AC HI Earth GND 12VDC Power GND Description Terminal Signal input and power, 115VAC or 230VAC depending on model selected. 12VDC power input 24VDC power input Ranging Header Zero Span IN+ IN- (optional) V+ 12 VDC DC GND 24 VDC EARTH GND AC LO AC HI DC Inputs (Non-Isolated DC Power) Description Signal Input DP1, DP2, DP3 -- Decimal point selection, connect to V+ as follows: DP1= XXX.X, DP2= XX.XX, DP3= X.XXX IN+ IN- DP1 DP2 DP3 V+ 24VDC Power GND DC voltage output to select decimal points Temperature Inputs V+ V- Description Terminal Zero F/C Selection Span Terminal 10-28VDC power input IN HI IN LO Signal Input BL + BL - Backlight power input DP1, DP2, DP3 -- Decimal point selection, connect to V+ as follows: DP1=XXX.X, DP2=XX.XX, DP3=X.XXX F C V+ V- IN HI IN LO BL+ BL- DP1 DP2 DP3 AC Power LO AC Power HI Description TC+ TC- Thermocouple Inputs AC Power Low AC Power HI AC Power Input, 115VAC or 230VAC depending on model selected 1 2 3 RTD inputs TC- AC LO AC HI DC Power (Optional) 24VDC Power GND AC Power 12V Power GND 12VDC power input 24VDC power input V+ IN HI IN LO DP1 DP2 12V PWR GND 24V IN + IN - 12 VDC PWR GND 24 VDC 12VDC Power GND F C TC+ AC LO AC HI IN + IN - DP1, DP2, DP3 -- Decimal point selection, connect to V+ as follows: DP1=XXX.X, DP2=XX.XX, DP3=X.XXX 1 2 3 2000 Series Scaling Chart Scaling Capability Model 2100, of the 2000 Series, provide the unique ability to switch-select a range and then scale and offset that range. Input will be displayed in engineering units. For example, by changing switch positions and recalibrating, a 2133-3419-04 may be set-up for any of the following displays: * 4 to 20mA input display -148F to 932F (-100C to +500C) temperature * 1 to 5V input displaying - 60kPa to 300kPa differential pressure * 0 to10V input displaying +700F to +950F (+682C to +932C) temperature * 0 to 50mV input displaying 0 to 300 amperes Zero Range Adjustment 4mA to 20mA, 1V to 5V -1000 counts to +1500 counts. Switch selectable in four ranges: a 25-turn potentiometer enables continuous adjustment. 0 to 200mV, 0 to 2V, 0 to 10V -1500 counts to +1500 counts. Switch selectable in six ranges: a 25-turn potentiometer enables continuous adjustment. Full Scale Span Adjustment All ranges 0 to 2000 counts. Switch selectable in four ranges: a 25-turn potentiometer enables continuous adjustment. Other ranges and scaling available. sales@jewellinstruments.com * www.jewellinstruments.com * 800 638-3771 How to Order 2 a b 0 3 1 3 - 3 c d 4 61 - e f 04 2 Configuration a 0 = 1/8 DIN 2 = TRMS (Inst) 1 = UPM 3 = TRMS (Power) 2000 and 2100 Series Specifications (continued) DC Inputs Input Resistance Overload Protection 200mVDC & 2VDC (.1% +1 count) typical (.2% +1 count) max. 100 Meg Ohms 200V continuous 300V intermittent 20VDC & 200VDC (.1% +1 count) typical (.2% +1 count) max. 1 Meg Ohm 350V continuous 500V intermittent DC Current (.1% +1 count) typical (.2% +1 count) max. 200mV drop full scale 3 times f.s. current 4 to 20mA, 10 Ohms 200mV, 200K Ohms 2V and up, 1Meg Ohm 4 to 20 mA, 100mA Voltage Inputs, 200V continuous 300V intermittent Display b 1 = Non Bklit 3 = Pos Grn Bklit 4 = Neg Grn Bklit 5 = Neg Red Bklit 6 = Pos Red Bklit DPM Power 2 0 = loop power c 2 = 5VDC 4 = 115VAC 6 = 10 to 28VDC 8 = 12 VDC 1 = 9 VDC 3 = +5 volts 5 = 230VAC 7 = 12 or 24VDC (Iso) 9 = 24VDC Input 00 = 100mVDC (1999 counts) 01 = 200mVDC scaled 0 to 199.9 02 = 2VDC scaled 0 to 1.999 03 = 20VDC 04 = 200VDC 05 = 1V to 5 VDC scaled 0 to 100.0 06 = 10VDC scaled 0 to 10.00 07 = 500VDC 10 = 200uADC 11 = 2mADC 12 = 20mADC 13 = 200mADC 18 = 4 to 20mADC Sq Rt 3 19 = 4 to 20mADC scaled 0 to 100.0 3 21 = 200.0mVAC RMS 22 = 2.000VAC RMS 23 = 20.00VAC RMS 24 = 200.0VAC RMS d 25 = 500VAC RMS 27 = 500VAC Avg 28 = 80.0 - 130.0VAC Avg 29 = 80 - 260VAC Avg 30 = 250VAC RMS 31 = 2.000mAAC RMS 32 = 20.00mAAC RMS 33 = 200.0mAAC RMS 34 = 2.000AAC RMS 36 = 5.00AAC4 RMS 37 = 50.0AAC4 RMS 38 = 0 - 5AAC4 AVG 39 = 0 - 50AAC4 AVG 60 = 40 to 440Hz 61 = 40.0 to 199.9Hz 70 = 100 Ohms Pt 1 Resolution 71 = 100 Ohms Pt .1 Resolution 80 = Type J Thermocouple 81 = Type K Thermocouple 82 = Type T Thermocouple Backlit Power 2 00 = No Backlight e 02 = 12VDC 04 = 115VAC 06 = 10 to 28VDC Display5 f 1 = 2000 4 = 600 7 = 200 01 = 5VDC 03 = 24VDC 05 = 230VAC 07 = 12 or 24VDC 2 = 1500 5 = 500 8 = 100 3 = 1000 6 = 300 Accuracy Universal Selectable (.1% +2 counts) Process AC Inputs Accuracy Input Resistance Overload Protection AC Voltage (.5% + 1 count) 1 Meg Ohm 350V continuous 500V intermittent 5A AC Current (.5% +1 count) Current transformer 3 times f.s. current 50A AC Current (.5% +5 counts) Current transformer 3 times f.s. current Frequency Inputs Accuracy Distortion 40.0 to 199.9Hz .2Hz (40 to 70Hz) .5Hz (above 70Hz) .1 Hz for up to 20% third harmonic distortion 40 to 440Hz 1Hz .1 Hz for up to 20% third harmonic distortion Temperature Inputs Accuracy Input Characteristic Overload Protection Type J thermocouple -10F to +1200F (.1% +1 count) accuracy (-23C to +649C) 1.3C (2.8F) conformity error 45 uV max per 100 Ohms 200V continuous thermocouple lead resistance Type K thermocouple -40F to +1500F (.1% +1 count) accuracy (-40C to +815C) 1.2C (2.5F) conformity error 45 uV max per 100 Ohms 200V continuous thermocouple lead resistance Type T thermocouple -100F to +600F (.1% +1 count) accuracy (-73C to +315C) 1.5C (3.5F) conformity error 45 uV max per 100 Ohms 200V continuous thermocouple lead resistance 100 Pt. =.00385 -200F to +600 F (-129C to +315C) (.2% + 1 count) max 1mA RTD current 5V 100 Pt. =.00385 -100.0F to +199.9F (-73C to +98C) (.2% + 1 count) max 1mA RTD current 5V 1 Change Order Number to "4" for 200 VDC Input 2 Backlit power must be the same as the selected DPM power. 3 Available on Non-Backlit meters only. 4 Rated for use with 5A or 50A external current transformer supplied with DPM. See high current connection on inside page. 5 For 5A current transformer inputs only. sales@jewellinstruments.com * www.jewellinstruments.com * 800 638-3771 850 Perimeter Road * Manchester, NH 03103 * USA