Magnetic sensors MTRM 16G2524/M100 Hall sensors 29 3,3 0 -0,1 +0,15 0 o 26 o 9 60 42 7,3 5,5 o 15,9 x5 16 3 2 H1 o 20 7 o 22 0,1 dimension drawing 33 10 29 0 -0,1 93 general data photo version full metal sensor type differential hall sensor working distance max. 1,0 mm (module 1) min. gear size module 1 gear width > 10 mm gear material ferromagnetic gear shape involute gear (DIN867) electrical data switching frequency range 2 ... 20 kHz voltage supply range +Vs 8 ... 28 VDC current consumption max. (no load) 20 mA output A push-pull output B push-pull output current < 30 mA voltage drop Vd < 5 VDC short circuit protection yes reverse polarity protection yes, Vs to GND connection diagram 1 Push Pull 3 Z Z Z Z 2 4 +VS output CHB output CHA 0V mechanical data type cylindrical, with flange housing material brass nickel plated dimension 16 mm housing length 93 mm installation aid pin hole connection types cable Radox, 2 m front of sensor durable against pressure 20 bar output signal CHA CHB ambient conditions operating temperature -40 ... +120 C protection class (sensing face) IP 68 protection class (sensor) IP 67 Fulfilled standards: EN 50155:2007 (class S1) EN 50121-3-2:2006 tables 7,8,9 EN 61373:1999 (cat. 3) www.baumer.com Fire protection (cable): CEN/TS 45545 2/7/2013