9.38
Max. Operating Voltage - UL:
Voltage
300 V RMS
Maximum DCR Unbalanced:
DCR Unbalance @ 20°C (%)
3
Electrical Characteristics-Premise (Overall)
Premise Cable Electrical Table 1:
Freq. (MHz) Max. Attenuation (dB/100 m) Min. NEXT (dB) Min. PSNEXT (dB) Min. ACR (dB) Min. PSACR (dB) Min RL (dB) Min. SRL (dB)
12.0 65.3 62.3 63.0 60.3 20.0 23
44.1 56.3 53.3 51.0 49.2 23.0 23.0
85.8 51.8 48.8 46.0 43.0 24.5 24.5
10 6.5 50.3 47.3 43.0 40.8 25.0 25.0
16 8.2 47.3 44.3 39.0 36.0 25.0 25.0
20 9.3 45.8 42.8 36.5 33.5 25.0 25.0
25 10.4 44.3 41.3 33.9 30.9 24.3 24.3
31.25 11.7 42.9 39.9 31.0 28.2 23.6 23.6
62.5 17.0 38.4 35.4 22.0 19.0 21.5 21.5
100 22.0 35.3 32.3 14.0 10.3 20.1 20.1
155 28.1 32.5 29.5 4.4 1.4 15.8
200 32.0 30.8 27.8 4.0 1.0 15.0
Premise Cable Electrical Table 2:
Freq. (MHz) Input (Unfitted) Imp. (Ohms) Fitted Impedance Min. ELFEXT (dB) Min. PSELFEXT (dB)
1100 ± 15 100 ± 15 63.8 60.8
4100 ± 15 100 ± 15 51.7 48.7
8100 ± 15 100 ± 15 45.7 42.7
10 100 ± 15 100 ± 15 43.8 40.8
16 100 ± 15 100 ± 15 39.7 36.7
20 100 ± 15 100 ± 15 37.7 34.7
25 100 ± 15 100 ± 15 35.8 32.8
31.25 100 ± 15 100 ± 15 33.9 30.9
62.5 100 ± 15 100 ± 15 27.8 24.9
100 100 ± 15 100 ± 15 23.8 20.8
155 100 ± 25 100 ± 15 19.9 16.9
200 100 ± 25 100 ± 15 17.7 14.7
Notes (Overall)
Notes: Jacket sequentially marked at 2 ft. intervals. Third party verified to TIA/EIA-568-C.2, Category 5e.
Put Ups and Colors:
Item # Putup Ship Weight Color Notes Item Desc
1594A 008U1000 1,000 FT 25.000 LB GRAY CAT5E 4PR U/UTP CMR/CMX BOX
1594A 009U1000 1,000 FT 25.000 LB WHITE CAT5E 4PR U/UTP CMR/CMX BOX
1594A 1GFU1000 1,000 FT 25.000 LB IVORY 1GF CAT5E 4PR U/UTP CMR/CMX BOX
Revision Number: 2 Revision Date: 08-14-2013
© 2013 Belden, Inc
All Rights Reserved.
Although Belden makes every reasonable effort to ensure their accuracy at the time of this publication, information and specifications
described herein are subject to error or omission and to change without notice, and the listing of such information and specifications does not
ensure product availability.
Belden provides the information and specifications herein on an "AS IS" basis, with no representations or warranties, whether express,
statutory or implied. In no event will Belden be liable for any damages (including consequential, indirect, incidental, special, punitive, or
exemplary damages) whatsoever, even if Belden has been advised of the possibility of such damages, whether in an action under contract,
negligence or any other theory, arising out of or in connection with the use, or inability to use, the information or specifications described herein.