KBPC3500S
THRU
KBPC3510S
35 Amp Single Phase
Bridge Rectifier
50 to 1000 Volts
Features
Maximum Ratings
Operating Temperature: -55°C to +150°C
Storage Temperature: -55°C to +150°C
MCC
Catalog
Number
Device
Marking Maximum
Recurrent
Peak Reverse
Voltage
Maximum
RMS
Voltage
Maximum
DC
Blocking
Voltage
KBPC3500S KBPC3500S 50V 35V 50V
KBPC3501S KBPC3501S 100V 70V 100V
KBPC3502S KBPC3502S 200V 140V 200V
KBPC3504S KBPC3504S 400V 280V 400V
KBPC3506S KBPC3506S 600V 420V 600V
KBPC3508S KBPC350 8S 800V 560V 800V
KBPC3510S KBPC3510S 1000V 700V 1000V
Electrical Characteristics @ 25°C Unless Otherwise Specified
Average Forward
Current IF(AV) 35.0A TC = 60°C
Peak Forward Surge
Current IFSM
400A 8.3ms, half sine
Maximum Forward
Voltage Drop Per
Element VF
1.2V IFM = 17.5A per
element;
TA = 25°C
Maximum DC
Reverse Current At
Rated DC Blocking
Voltage
IR10µA
1.0mA TA = 25°C
TA = 100°C
*Pulse test: Pulse width 300 µsec, Duty cycle 1%
KBPC
Ideal for Printed Circuit Boards
Designed for Saving Mounting Space
Low Forward Voltage Drop
High Current Capability
High Reliability
High Surge Current Capability
www.mccsemi.com
INCHES MM
DIM MIN MAX MIN MAX NOTE
A 1.12 1.13 28.40 28.70
B .432 .442 10.97 11.23
C .547 --- 13.90 ---
D .752 --- 19.10 ---
E .201 --- 5.10 ---
G .047 --- 1.20 ---
H .120 .142 3.05 3.60
DIMENSIONS
omponents
21201 Itasca Street Chatsworth

 !"#
$% !"#
MCC
KBPC3500S thru KBPC3510S
Instantaneous Reverse Leakage Current - MicroAmperes versus
Percent Of Rated Peak Reverse Voltage - Volts
Average Forward Rectified Current - Amperes versus
Case Temperature - °C
Figure 3
Forward Derating Curve
25 50 100 150 175
0
0
10
20
30
Single Phase, Half Wave
60Hz Resistive or Inductive Load
Amps
°C
75
40
50
60
Instantaneous Forward Current - Amperes versus
Instantaneous Forward Voltage - Volts
Figure 1
Typical Forward Characteristics
Volts
4
6
20
10
Amps
.2 1.2
.4 .6 .8 1.0
.01
.02
.04
.06
.1
.2
.4
.6
1
225°C
40
60
100
1.4
Figure 2
Typical Reverse Characteristics
Volts
.4
.6
2
1
µ
Amps
20 120
40 60 80 100
.001
.002
.00
4
.006
.01
.02
.04
.06
.1
.2
4
6
10
TA=25°C
1 100
4
0
100
300
8
Figure 4
Peak Forward Surge Current
Peak Forward Surge Current - Amperes versus
Number Of Cycles At 60Hz - Cycles
Amps
Cycles
2
6
10 20 60 80
40
00
400
500
600
MCC