KBU6A THRU KBU6M
Features
Mechanical Data
· Diffused Junction
· Low Forward Voltage Drop, High Current Capability
· Surge Overload Rating to 250A Peak
· Ideal for Printed Circuit Board Applications
· Case to Terminal Isolation Voltage 1500V
· Plastic Material - UL Flammability
Classification Rating 94V-0
Maximum Ratings And Electrical Characteristics
· Case : Molded Plastic
· Terminals : Plated Leads Solderable per
MIL-STD-202, Method 208
· Polarity : As Marked on Case
· Mounting : Through Hole for #6 Screw
· Mounting Torque : 5.0 Inch-pounds Maximum
· Weight : 8.0 grams (approx.)
· Mounting Position : Any
· Marking : Type Number
(Ratings at 25℃ ambient temperature unless otherwise specified, Single phase, half wave 60Hz, resistive or inductive
load. For capacitive load, derate by 20%)
CURRENT 6.0 Amperes
VOLTAGE 50 to 1000 Volts
Notes:
(1) Thermal resistance junction to case mounted on heat sink.
(2) Non-repetitive, for t > 1.0ms and t < 8.3ms.
Peak Repetitive Reverse voltage
Working Peak Reverse voltage
DC Blocking voltage
RMS Reverse voltage
Average Rectified Output Current @ T
C
=100
Non-Repetitive Peak Forward Surge Current,
8.3ms single half-sine-wave superimposed
on rated load (JEDEC method)
Volts
Forward voltage (per element) @ I
F
=3.0 A
V
RMM
V
RWM
V
R
50 Volts
Symbols Units
1.0V
FM
V
RMS
6.0
Amps200I
FSM
T
j
T
STG
1.0
-65 to +150 ℃
Amps
Peak Reverse Current at Rated
DC Blocking voltage
I
2
t Rating for Fusing (Note 2)
Operating and Storage Temperature Range
KBU
6A KBU
6B KBU
6D KBU
6G KBU
6J KBU
6K KBU
6M
35
10
166
100
70
200
140
400
280
600
420
800
560
1000
700 Volts
μA
mA
A
2S
℃/W
Io
I
RM
I
2
t
Rθ
JA
@ T
C
=25℃
@ T
C
=100℃
Typical Thermal Resistance,
Junction to Case (Note 1) 6.3
℃
-~~+
B
C
D
H
M
N
P
A
E
L
K
J
G
KBU
Dim Min Max
A22.70 23.70
10.30 11.30
B3.80 4.10
4.20 4.70
1.70 2.20
4.50 6.80
4.80 5.80
16.80
25.40
17.80
19.30
6.60 7.10
4.70 5.20
1.20 1.30
C
G
D
H
E
All Dimens ions in mm
Dim Min Max
K
J
L
M
N
P