DO NOT
SCALE FROM
THIS PRINT
.725 18.42
REF
.010 0.25
REF
.055 1.40
.120 3.05
REF
(((No OF POSITIONS / 14) x .7875[20.003])
+ .005[.13])
.003[.08]
"A"
"A"
-LC: LOCKING CLIP OPTION SHOWN
T-1G2-01-XXX
LC-08-TM-01
QSE-042-01-XXX-D-DP-LC SHOWN
QSE-20-01-D-XX
FIG 1
SEE NOTE 16
.138 3.52
REF
.285 7.24
REF
.006
REF
0.15
((No OF POSITIONS / 14) x .7875[20.003]) + .0500[1.270] REF
.625 15.88
REF
.032 0.80
REF
.095 2.40
REF
6 EQ. SPACES
x .094 [2.40]
.022 0.57
REF
.788 20.00
C
01
02
QSE-XXX-XX-XXX-D-DP-XXX-XXXXX
No OF POSITIONS
-014, -028, -042, **-056, **-070
(PER ROW)
ROW SPECIFICATION
-D: DOUBLE (USE QSE-20-01-D-XX)
OPTION
-A: ALIGNMENT PINS
(USE QSE-20-01-D-XX-A)
-LC: LOCKING CLIPS
(USE LC-08-TM-01)(SEE NOTE 15)
-K: POLYIMIDE FILM
(USE K-DOT-.325-.450-.005, SEE FIG 2, SHT 2)
-TR: TAPE & REEL (42 POS. MAX)
(28 POS. MAX FOR -GP)
-GP: GUIDE POSTS
(USE QSE-20-XX-D-GP, SEE FIG 3, SHT 2)
-RT1: RETENTION (MUST USE -A OPTION)
(USE QSE-20-01-D-XX-A-RT1
& SUB-SC-05-01-FF) (SEE FIG 4, SHT 2)
(NOT AVAILABLE WITH -LC OR -GP)
(NOT AVILABLE IN 056 OR 070 POS)
-L: LATCHING OPTION (40 POS. MAX.)
(SEE FIG 7, SHT 4)
(MUST USE -A OPTION)
(NOT AVAILABLE WITH -LC, -GP, -FL, OR -RT1)
PLATING SPECIFICATION
PLATING THICKNESSES ARE FOR
SIGNAL PINS ONLY. FOR GROUND
PLANE THICKNESSES, SEE PP-T-1G2-XX-X.
(SEE NOTES 7, 12 & 14)
-F: 3µ" SELECTIVE GOLD CONTACT,
MATTE TIN TAIL
(USE C-126-21-F, T-1G2-01-F)
-L: 10µ" SELECTIVE GOLD CONTACT,
MATTE TIN TAIL
(USE C-126-21-L, T-1G2-01-L)
-H: 30µ" GOLD CONTACT, 3µ" GOLD TAIL
(USE C-126-21-H, T-1G2-01-G)
-C: 50µ" ELECTRO POLISHED SELECTIVE
GOLD CONTACT, MATTE TIN TAIL
(USE C-126-21-C, T-1G2-01-L)
-STL: 30µ" SELECTIVE GOLD CONTACT,
TIN LEAD (90/10 ±5%) TAILS
(USE C-126-21-STL, T-1G2-01-STL)
-FTL: 3µ" SELECTIVE GOLD CONTACT,
TIN LEAD
(90/10 ±5%) TAILS
(USE C-126-21-FTL, T-1G2-01-FTL)
-S: 30µ" SELECTIVE GOLD CONTACT,
MATTE TIN TAIL
(USE C-126-21-S, T-1G2-01-L)
LEAD STYLE
-01: .1280 [3.30]
-02: .2460[6.248]
No OF BANKS
BODY STYLE
-DP: DIFFERENTIAL PAIRS
* = NOT TOOLED
** = SEE NOTE 13
*
PIN COUNT, BANKS 1-5
(SEE NOTES 11, 13 & 14)
-S: STANDARD
-D: DIFFERENTIAL
(SEE NOTE 10 &
FIG 5, SHT 3)
.070
REF
1.77
.295
REF
7.49
.1280
-
.0010
+
.0030 3.251
-
0.025
+
0.076
(SEE NOTE 5 & 6)
.007 0.18
REF
.038 0.95
SECTION "A"-"A"
C
C-126-21-XXX
***SEE NOTE 14
C
SEE TABLE 1
.035
REF
0.89
(((No OF POSITIONS / 14) x .7875[20.003])
+ .005[.13])
.003[.08]
-A: ALIGNMENT PIN OPTION SHOWN
QSE-20-01-D-XX-A
.037 0.95
REF
.038
REF
0.95
R
(SEE NOTE 11)
C
SHEET OF
UNLESS OTHERWISE SPECIFIED,
DIMENSIONS ARE IN INCHES.
TOLERANCES ARE:
DECIMALS ANGLES
.XX:
.01 [.25] 2
.XXX:
.005 [.13]
.XXXX:
.0020 [.05]
MATERIAL:
.8mm DIFFERENTIAL PAIRS HS SOCKET ASSEMBLY
BY:
QSE-XXX-XX-XXX-D-DP-XXX-XXXXX
DWG. NO.
DESCRIPTION:
PROPRIETARY NOTE
THIS DOCUMENT CONTAINS INFORMATION
CONFIDENTIAL AND PROPRIETARY TO
SAMTEC, INC. AND SHALL NOT BE REPRODUCED
OR TRANSFERRED TO OTHER DOCUMENTS OR
DISCLOSED TO OTHERS OR USED FOR ANY
PURPOSE OTHER THAN THAT WHICH IT WAS
OBTAINED WITHOUT THE EXPRESSED WRITTEN
CONSENT OF SAMTEC, INC.
DO NOT SCALE DRAWING
DEAN P
5/05/2000
4
1
SHEET SCALE: 1.375:1
INSULATOR: LCP, COLOR: BLACK, FLAMMABILITY RATING: UL94VO
CONTACT: PHOS BRONZE
GROUND PLANE: PHOS BRONZE
F:\DWG\MISC\MKTG\QSE-XXX-XX-XXX-D-DP-XXX-XXXXX-MKT.SLDDRW
NOTES:
1. REPRESENTS A CRITICAL DIMENSION.
2. MIN TERMINAL RETENTION: 5 OZ.
3. MIN GROUND PLANE RETENTION: 8 OZ.
4. PARTS TO BE MOLDED TO POSITION.
5. MAX VARIENCE: .002 [0.05].
6. DIMENSION APPLIES TO TERMINALS AND GROUND PLANE.
7. -L PLATING CAN BE SUBSTITUTED FOR -F PLATING.
8. GROUND PLANE PRESS HEIGHT MUST BE .003[0.08] LESS THAN THE MAXIMUM
HEIGHT OR .001[0.03] GREATER THAN THE MINIMUM HEIGHT OF THE SOCKETS.
9. SUB-SC-05-01-XX RETENTION TO BE 1.0 LBF IN BODY.
10. IF ORDERING ALL BANKS DIFFERENTIAL PAIR, LEAVE BLANK. IF ORDERING ALL
BANKS STANDARD PIN COUNT, ORDER QSE-XXX-XX-X-D-XXX (STANDARD QSE)
11. PIN COUNT PER ROW= (# -DP BANKS X 14) + (# -S BANKS X 20)
12. MAY SUB C-126-01-XXX FOR C-126-21-XXX.
13. FOR NEW APPLICATIONS REQUIRING THESE POSITIONS, PLEASE CONTACT SAMTEC
INTERCONNECT PROCESSING GROUP.
14. FOR -056, -070 POSITIONS USE C-269-11-XXX. DO NOT SUB C-126.
15. DUE TO THE HIGH AMOUNT OF INSERTION FORCE NEEDED, THE -LC OPTION
IS NOT COMPATIBLE WITH AUTO PLACEMENT. SAMTEC RECOMMENDS
MANUAL PLACEMENT FOR ALL ASSEMBLIES WITH THE -LC OPTION.
16. SIDE WALLS ARE RIBBED AS NECESSARY TO CONTROL BOW.
520 PARK EAST BLVD, NEW ALBANY, IN 47150
PHONE: 812-944-6733 FAX: 812-948-5047
e-Mail info@SAMTEC.com code 55322
REVISION AI