IP137A , IP137AHV IP137 , IP137HV
LM137A , LM137AHV LM137 , LM137HV
Parameter Test Conditions Min. Typ. Max. Min. Typ. Max. Units
IOUT = 10mA
IOUT = 10mA to IMAX
VIN – VOUT = 3V to VMAX
P
£
PMAX TJ= -55 to 150°C
VIN – VOUT = 3V to VMAX
TJ= -55 to 150°C
IOUT = 10mA to IMAX VOUT
£
5V
VOUT
³
5V
IOUT = 10mA to IMAX VOUT
£
5V
TJ= -55 to 150°C VOUT
³
5V
tp= 10ms TA= 25°C
CADJ = 0
VOUT = -10V CADJ = 10
m
F
f = 120Hz TJ= -55 to 150°C
TJ= -55 to 150°C IOUT = 10mA to IMAX
TJ= -55 VIN – VOUT = 3V to 40V
to 150°C VIN – VOUT = 3V to 50V
(HV SERIES)
VIN – VOUT
£
40V
TJ= -55 to 150°C VIN – VOUT
£
10V
VIN – VOUT
£
15V
VIN – VOUT = 40V
TJ= -55 to 150°C VIN – VOUT = 50V
(HV SERIES)
TJ= -55 to 150°C
TA= +125°C
t = 1000 Hrs
f = 10 Hz to 10 kHz
TA= 25°C
K Package
R Package
G Package
-1.225 -1.25 -1.275
-1.200 -1.250 -1.300
0.010 0.020
0.020 0.050
15 25
0.3 0.5
20 50
0.3 1
0.002 0.02
60
66 77
65 100
0.5 5
25
36
2.5 5
1.2 3
1.5 2.2 3.2
0.24 0.4
0.2 0.4 0.8
0.6
0.3 1
0.003
2.3 3
57
35
-1.238 -1.25 -1.262
-1.220 -1.25 -1.280
0.005 0.010
0.010 0.030
525
0.1 0.5
10 50
0.2 1
0.002 0.020
60 66
70 80
65 100
0.2 2
1.0 5
2.0 6
2.5 5
1.2 3
1.5 2.2 3.2
0.24 0.4 1
0.2 0.4 0.8
0.6 1.5
0.3 1
0.003
2.3 3
57
35
VREF Reference Voltage
D
VOUT Line Regulation 1
D
IOUT
D
VOUT Load Regulation 1
D
IOUT
Thermal Regulation
Ripple Rejection
IADJ Adjust Pin Current
D
IADJ Adjust Pin Current
Change
IMIN Minimum Load
Current
ICL Current Limit
D
VOUT Temperature
D
TEMP Stability
D
VOUT Long Term Stability
D
TIME
enRMS Output Noise
(% of VOUT)
R
q
JC Thermal Resistance
Junction to Case
Prelim. 7/00
IP137ASERIES
IP137A SERIES
IP337A SERIES
IP337A SERIES
LM137A SERIES
LM137A SERIES
Semelab plc. Telephone +44(0)1455 556565. Fax +44(0)1455 552612.
E-mail: sales@semelab.co.uk Website: http://www.semelab.co.uk
V
V
%/V
mV
%
mV
%
%/W
dB
dB
m
A
m
A
mA
A
%
%
%
°C/W
1) Regulation is measured at constant junction temperature, using pulse testing at a low duty cycle. Changes in output voltage due to
heating effects are covered under thermal regulation specifications. Load regulation is measured at a point 1/8” from the bottom of
the package for the TO–3 and TO–66 packages, at the junction of the wide and narrow portion of the output lead for the SMD1
package, and 1/8” below the base of the package on the output pin of the TO–257 package.
2) Test Conditions unless otherwise stated: VIN – VOUT = 5V , IOUT = 0.5A , PMAX = 20W , IMAX = 1.5A
VMAX = 40V for standard series , 50V for HV series.