SPT Series Low Cost, Stainless Steel Media Isolated Pressure Sensors DESCRIPTION Honeywell's SPT Series stainless steel pressure sensors are All versions feature a variety of pressure connections to allow designed for media that will not adversely attack 316L stainless use in a wide range of OEM (Original Equipment Manufacturer) steel. equipment. The back side metal tube is made from 304 stainless steel The SPT Series stainless steel devices are rugged and reliable which provides effective protection against most harsh transducers for use in a wide variety of pressure sensing environments. The SPT Series is calibrated and compensated applications where corrosive liquids and gases are monitored. for three styles of output: 4.0 mA to 20.0 mA (mA version); 1.0 Vdc to 5.0 Vdc (4 V version); and 0 mV to 100 mV (mV version). FEATURES POTENTIAL APPLICATIONS * Reliable semiconductor technology * Industrial automation and flow control * Calibrated and temperature compensated * Pressure instrumentation * Rugged, stainless steel package * Hydraulic systems * NEMA 4 design * Process control * Small size * Absolute, gage, sealed gage, vacuum gage pressures * 0 psi to 3 psi, 0 psi to 5000 psi SPT Series Table 1. Specifications Characteristic Environmental specifications Parameter Compensated temperature range Operating temperature range -10 C to 85 C [14 F to 185 F] -40 C to 85 C [-40 F to 185 F] Storage temperature range Vibration -40 C to 85 C [-40 F to 185 F] 10 G at 20 Hz to 2000 Hz Shock Insulation resistance 100 G for 11 ms 100 M at 50 Vdc Recommended supply range SPT mA supply voltage +12.5 Vdc to +24 Vdc SPT 4V Supply voltage VS Quiescent current IQSC Short circuit current ISC SPT mV supply voltage VS +12.5 Vdc to +24 Vdc 5 mA 18 mA +10 Vdc Maximum supply ratings SPT mV supply voltage VS SPT mA and SPT 4V supply voltage VS +15 Vdc +24 Vdc Table 2. Pressure Range Specifications 1 Catalog Listing SPT (mA, mV, 4V) 0003P G (4,5,6,7,9) (B/WXX) SPT (mA, mV, 4V) 0005P G (4,5,6,7,9) (B/WXX) SPT (mA, mV, 4V) 0010P G (4,5,6,7,9) (B/WXX) SPT (mA, mV, 4V) 0015P (A,G,V) (4,5,6,7,9) (B/WXX) SPT (mA, mV, 4V) 0030P (A,G,V) (4,5,6,7,9) (B/WXX) SPT (mA, mV, 4V) 0050P (A,G,V) (4,5,6,7,9) (B/WXX) SPT (mA, mV, 4V) 0100P (A,G,V) (4,5,6,7,9) (B/WXX) SPT (mA, mV, 4V) 0200P (A,G,V) (4,5,6,7,9) (B/WXX) SPT (mA, mV, 4V) 0300P (A,G,V) (4,5,6,7,9) (B/WXX) SPT (mA, mV, 4V) 0500P (A,G,V) (4,5,6,7,9) (B/WXX) SPT (mA, mV, 4V) 1000P (A,S) (4,5,6,7) (B/WXX) SPT (mA, mV, 4V) 2000P (A,S) (4,5,6,7) (B/WXX) SPT (mA, mV, 4V) 3000P (A,S) (4,5,6,7) (B/WXX) SPT (mA, mV, 4V) 5000P (A,S) (4,5,6,7) (B/WXX) Pressure Range 0 psig to 3 psig 0 psig to 5 psig 0 psig to 10 psig 0 psi to 15 psi 0 psi to 30 psi 0 psi to 50 psi 0 psi to 100 psi 0 psi to 200 psi 0 psi to 300 psi 0 psi to 500 psi 0 psi to 1000 psi 0 psi to 2000 psi 0 psi to 3000 psi 0 psi to 5000 psi Proof Pressure 9 psig 15 psig 30 psig 45 psi 90 psi 150 psi 300 psi 600 psi 900 psi 1200 psi 3000 psia 6000 psia 9000 psia 10000 psia 2 Burst Pressure 15 psig 25 psig 50 psig 75 psi 150 psi 250 psi 500 psi 100 psi 1500 psi 2400 psi 5000 psia 10000 psia 10000 psia 10000 psia 3 Notes: 1. Vacuum gage units (V option) allow you to pull a hard vacuum on the gage units. Vacuum gage parts are only available on the mV version in 15 psig through 500 psig. As sold, this package design is not submersible. In order to make the package submersible, the package needs to be sealed. 2. The maximum pressure that can be applied without changing the transducer's performance or accuracy. 3. The maximum pressure that can be applied to a transducer without rupture of either the sensing element or transducer case. 2 www.honeywell.com/sensing Low Cost, Stainless Steel Media Isolated Pressure Sensors Table 3. Performance Specifications 1 Characteristic Minimum Typical Maximum Unit SPT mV Version Zero pressure offset 2 Full-scale span (0 psig to 3 psig and 0 psig-5 psig only) 2 Full-scale span (0 psi to10 psi and 0 psi to 3000 psi only) 2 Full-scale span (0 psi to 5000 psi only) 3 Pressure non-linearity 3 Pressure hysteresis Repeatability 4 Temp. effect on span 4 Temp. effect on offset 4 Temp. effect on span (0 psi to 3 psi and 0 psi to 5 psi only) 4 Temp. effect on offset (0 psi to 3 psi and 0 psi to 5 psi only) Thermal hysteresis (-10 C to 85 C [14 F to 185 F]) 5 Long-term stability of offset and span 6 Response time 7 Common mode voltage (voltage version "K") Input resistance Output resistance -2 48 98 148 - - - - - - - - - - 0.5 8.0 3.0 0 50 100 150 0.1 0.015 0.010 0.5 0.5 1 1 0.1 0.1 0.1 1.25 25 4.5 +2 52 102 152 0.25 0.030 0.030 1.0 1.0 2.0 2.0 0.3 0.3 - 2.0 50 6.0 mV mV mV mV %FSS %FSS %FSS %FSS %FSS %FSS %FSS %FSS %FSS ms Vdc k k SPT mA Version Zero pressure offset 2 Full-scale span 3 Pressure non-linearity 3 Pressure hysteresis Repeatability 4 Temp. effect on span 4 Temp. effect on offset 4 Temp. effect on span (0 psi to 3 psi and 0 psi to 5 psi only) 4 Temp. effect on offset (0 psi to 3 psi and 0 psi to 5 psi only) Thermal hysteresis -10 C to 85 C [14 F to 185 F] 5 Long term stability of offset and span 6 Response time 3.84 15.84 - - - - - - - - - - 4.0 16.0 0.1 0.015 0.010 0.5 0.5 1.5 1.5 0.1 0.1 5 4.16 16.16 0.25 0.03 0.030 1.5 1.5 2.5 2.5 0.3 0.3 - mA mA %FSS %FSS %FSS %FSS %FSS %FSS %FSS %FSS %FSS ms 0.96 3.96 - - - - - - - - - - 1.0 4.0 0.1 0.015 0.010 0.5 0.5 1.5 1.5 0.1 0.1 5 1.04 4.04 0.25 0.03 0.030 1.5 1.5 2.5 2.5 0.3 0.3 - V V %FSS %FSS %FSS %FSS %FSS %FSS %FSS %FSS %FSS ms SPT 4V Version Zero pressure offset 2 Full-scale span 3 Pressure non-linearity 3 Pressure hysteresis Repeatability 4 Temp. effect on span 4 Temp. effect on offset 4 Temp. effect on span (0 psi to 3 psi and 0 psi to 5 psi only) 4 Temp. effect on offset (0 psi to 3 psi and 0 psi to 5 psi only) Thermal hysteresis -10 C to 85 C [14 F to 185 F] 5 Long term stability of offset and span 6 Response time Notes: 1. Reference conditions (unless otherwise noted): TA = 25 C [77 F]; For SPTmA and SPT4V, Supply VS = 23.5 Vdc 0.01 Vdc; for SPTmV: VS = 10 Vdc. 2. Full-scale span (FSS) is the algebraic difference between the output voltage at full-scale positive pressure and the output at zero pressure. FSS is ratiometric to the supply voltage. 3. Pressure non-linearity is based on best-fit straight line from zero to the full-scale pressure. Pressure hysteresis is the maximum output difference at any point within the operating pressure range for increasing and decreasing pressure. 4. Maximum error band of the offset voltage or span over the compensated temperature range, relative to the 25 C [77 F] reading. 5. Long-term stability over a six-month period. 6. Response time for a 0 psi to FSS pressure step change, 10% to 90% rise time. 7. Common mode voltage as measure from output to ground. Honeywell Sensing and Control 3 Figure 1. Equivalent Basic Circuits SPT mA SPT 4V Figure 2. SPT mA Version External Load Line SPT mV Figure 3. Pinout and Wire Code for all Package Styles MOUNTING DIMENSIONS (For reference only, in (mm).) Figure 4: Package 4: 1/8-27 NPT Port *Bayonet termination is dimensionally equivalent to an Amphenol Bendix PTIH-8-4P. 4 www.honeywell.com/sensing Low Cost, Stainless Steel Media Isolated Pressure Sensors Figure 5. Package 5: 1/4-18 NPT Port Figure 6. Package 6: 7/16-20 UNF Port *Bayonet termination is dimensionally equivalent to an Amphenol Bendix PTIH-8-4P. Honeywell Sensing and Control 5 Figure 7. Package 7: 1/4-19 BSPP Port Figure 8. Package 9: VCR Port *Bayonet termination is dimensionally equivalent to an Amphenol Bendix PTIH-8-4P. 6 www.honeywell.com/sensing Low Cost, Stainless Steel Media Isolated Pressure Sensors Order Guide SPT mA SPT mV SPT 4V Honeywell Sensing and Control 7 WARNING WARNING PERSONAL INJURY MISUSE OF DOCUMENTATION DO NOT USE these products as safety or emergency stop * devices or in any other application where failure of the The information presented in this product sheet is for reference only. Do not use this document as a product product could result in personal injury. installation guide. Failure to comply with these instructions could result in death or serious injury. * Complete installation, operation, and maintenance information is provided in the instructions supplied with each product. Failure to comply with these instructions could result in WARRANTY/REMEDY Honeywell warrants goods of its manufacture as being free of death or serious injury. defective materials and faulty workmanship. Honeywell's standard product warranty applies unless agreed to otherwise SALES AND SERVICE by Honeywell in writing; please refer to your order Honeywell serves its customers through a worldwide network acknowledgement or consult your local sales office for specific of sales offices, representatives and distributors. For warranty details. If warranted goods are returned to Honeywell application assistance, current specifications, pricing or name during the period of coverage, Honeywell will repair or replace, of the nearest Authorized Distributor, contact your local sales at its option, without charge those items it finds defective. The office or: foregoing is buyer's sole remedy and is in lieu of all other warranties, expressed or implied, including those of E-mail: info.sc@honeywell.com merchantability and fitness for a particular purpose. In no event shall Honeywell be liable for consequential, special, or indirect damages. Internet: www.honeywell.com/sensing Phone and Fax: While we provide application assistance personally, through Asia Pacific +65 6445-3033 Fax our literature and the Honeywell web site, it is up to the customer to determine the suitability of the product in the +65 6355-2828 Europe +44 (0) 1698 481481 +44 (0) 1698 481676 Fax application. Latin America +1-305-805-8188 Specifications may change without notice. The information we supply is believed to be accurate and reliable as of this printing. However, we assume no responsibility for its use. +1-305-883-8257 Fax USA/Canada +1-800-537-6945 +1-815-235-6847 +1-815-235-6545 Fax Sensing and Control Honeywell 1985 Douglas Drive North Golden Valley, MN 55422 www.honeywell.com/sensing 008133-2-EN IL50 GLO Printed in USA August 2009 Copyright (c) 2009 Honeywell International Inc. All rights reserved.