100 Watt Industrial Features l 100 W convection-cooled rating l Small 5 x 3 x 1.07 inches form factor l 6.7 W/in power density l High efficiency > 85% l Low conducted and radiated noise l Power good and power fail signal l Cover kit accessory available Electrical Specifications AC Input Input Frequency Input Current Inrush Current Leakage Current Efficiency Hold-up Time Output Power Line Regulation Load Regulation1 Transient Response Rise Time Set Point Tolerance Over Current Protection Over Voltage Protection Short Circuit Protection Switching Frequency Operating Temperature Storage Temperature Relative Humidity Altitude MTBF Isolation Voltage Cooling 90-264 V, Universal 47-63 Hz 120 VAC: 2.0 A max. 230 VAC: 1.0 A max. 120 VAC: 18 A max. 230 VAC: 35 A max. 120 VAC: < 500 A 230 VAC: < 1000 A 120 VAC: 83% typical 230 VAC: 85% typical 120 VAC: 10 ms 230 VAC: 16 ms 100 W +/-0.3% V1: +/-1%; V2, V3 and V4: +/-5% 10%, 50% to 100% load change, 50/60 Hz, 50% duty cycle, 0.1 A/s, recovery time < 5 ms < 50 ms V1: +/-2%; V2, V3, V4: +/-5% 110 to 170% 6.2 V +/-0.4 V for 5 V Short term, autorecovery Boost converter: 45 kHz typical Resonant converter: 45 kHz typical 0 to 70C, refer derating curve -40 to +85C 95% Rh, noncondensing Operating: 10,000 ft.; Nonoperating: 40,000 ft. 1.02m Hours, Telcordia SR332 Issue-3 Min. 4242 VDC between input to output Convection 31 4EM-15-062 39-DE60-43931-002 / B Model Number Voltage LFVLT100-1001 V1=12 V LFVLT100-1002 V1=15 V LFVLT100-1003 V1=24 V LFVLT100-1004 V1=48 V LFVLT100-4000 V1=5.1 V, V2=12.25 V, V3=-5 V, V4=-12 V LFVLT100-4001 V1=5.1 V, V2=24.5 V, V3=12 V, V4=-12 V LFVLT100-4002 V1=5.1 V, V2=16 V, V3=-4.8 V, V4=-15.5 V LFVLT100-4003 V1=5.1 V, V2=12 V, V3=24 V, V4=-12 V LFVLT80-CK metal cover kit accessory Max. Load2 Min. Load Ripple3 7.5 A 6.67 A 4.2 A 2.1 A V1=12.0 A, V2=4.0 A, V3=0.8 A, V4=0.8 A V1=12.0 A, V2=2.0 A, V3=0.8 A, V4=0.8 A V1=12.0 A, V2=3.0 A, V3=0.8 A, V4=0.8 A V1=12.0 A, V2=4.0 A, V3=0.8 A, V4=0.8 A 1.0 A 0.5 A 0.1 A 0.2 A V1=3.0 A, V2=0.1 A, V3=0.0 A, V4=0.0 A V1=3.0 A, V2=0.1 A, V3=0.0 A, V4=0.0 A V1=3.0 A, V2=0.1 A, V3=0.0 A, V4=0.0 A V1=3.0 A, V2=0.1 A, V3=0.0 A, V4=0.0 A 3% 3% 1.5% 1.04% V1, V2=1.5% V3=2%, V4=1.25% 1% V1, V2, V4=1% V3=2% 1% Connectors J1 Pin 1 Pin 2 Spade Connector J2 Pin 1, 2, 3, 4 Pin 5, 6, 7, 8 Pin 9, 10 Pin 11 Pin 12 J3 Pin 1 Pin 2 AC NEUTRAL AC LINE EARTH V1 RTN V2 V3 V4 RTN POWER FAIL/GOOD Notes 1. Single output models: +/-2.5% for 12 V, +/-3% for 15 and 24 V, +/-2% for 48 V. Quad output models : +/-1% for V1; +/-5% for V2, V3, V4. 2. Maximum current per output channel. Do not exceed total output power rating. 3. Ripple is peak to peak with 20 MHz bandwidth and 10 F (Tantalum capacitor) in parallel with a 0.1 F capacitor at rated line voltage and load ranges. 4. Power fail and power good signal on quad output models only. 5. Specifications are for nominal input voltage, 25C and max. load unless otherwise stated. 6. Derate output power linearly to 80% from 90 VAC to 80 VAC input. 2 Innovations in Power 4EM-15-062 39-DE60-43931-002 / B Mechanical Specifications AC Input Connector (J1) EARTH DC Output Connector (J2) Signal Connector (J3) Dimensions Weight Molex: 26-60-4030 or equivalent Mating: 09-50-3031; Pins: 08-50-0106 Molex: 19705-4301 Mating: 190030001 Tyco: 1-640445-2 or equivalent Mating: 1-647402-2; Pins: 3-647409-1 Molex: 22-23-2021 or equivalent Mating: 22-01-2021 5.0 x 3.04 x 1.07 inches (127.0 x 77.22 x 27.18 mm) 250 g EMC CE Mark Conducted Emissions Static Discharge RF Field Susceptibility Fast Transients/Bursts Radiated Emissions Surge Susceptibility Harmonic current Complies with LVD Directive EN55022-B, CISPR22-B, FCC PART15-B, EN50082-1 EN61000-4-2, Level-3 EN61000-4-3, Level-3 EN61000-4-4, Level-3 EN55022-B, CISPR22-B, FCC PART15-B To be controlled in end system EN61000-4-5, Level-3 EN61000-3-2, Class A Safety Safety Standard(s) Approval Agency Safety File Number(s) IEC60950-1 (ed.2), EN60950-1, UL60950-1 (2nd Edition), CSA C22.2 No. 60950-1 (2nd Edition), Class 1 SELV Nemko, UL, C-UL Nemko: P09210934 UL: E150565 Signal Power Fail/Good Signal4 Signal goes high after a delay of 100 ms once main output is within regulation band. Signal goes low 1.5 ms advance before output goes out of regulation due to mains failure 33 4EM-15-062 39-DE60-43931-002 / B Derating Curve Mechanical Drawing MOUNTING HARDWARE O0.312 [O7.9] CLEARANCE TOP/BOTTOM 4-PLS 5.00 [127.0] 4.550 [115.6]0.01[0.25] 0.225 [5.7] 1.073 [27.25] 0.225 [5.7] 2.55 [64.8] 0.01[0.25] 3.00 [76.2] MAXIMUM 0.04 [1.0] 3.04 [77.2] PF 2 GND1 J3 J1 1-N J2 1 2-L O 0.159 [O4.0] CENTER PIN REMOVED 4-PLS 0.82 [20.8] MAXIMUM COMPONENT HT ABOVE PCB 0.19 [4.8] MAXIMUM COMPONENT HT BELOW PCB MECHANICAL OUTLINE DIMENSIONS ALL DIMENSIONS ARE IN INCHES [MM] GEN. TOLERANCE: +/-0.02 [+/-0.5] 4 Innovations in Power 4EM-15-062 39-DE60-43931-002 / B