31
100 Watt Industrial
l 100 W convection-cooled rating
l Small 5 x 3 x 1.07 inches form factor
l 6.7 W/in³ power density
l High efficiency > 85%
l Low conducted and radiated noise
l Power good and power fail signal
l Cover kit accessory available
Features
Electrical Specifications
AC Input 90
-
264 V, Universal
Input Frequency 47
-
63 Hz
Input Current 120 VAC: 2.0 A max. 230 VAC: 1.0 A max.
Inrush Current 120 VAC: 18 A max. 230 VAC: 35 A max.
Leakage Current 120 VAC: < 500 µA 230 VAC: < 1000 µA
Efficiency 120 VAC: 83% typical 230 VAC: 85% typical
Hold-up Time 120 VAC: 10 ms 230 VAC: 16 ms
Output Power 100 W
Line Regulation
+
/
-
0.3%
Load Regulation1 V1:
+
/
-
1%; V2, V3 and V4:
+
/
-
5%
Transient Response 10%, 50% to 100% load change, 50/60 Hz, 50% duty cycle, 0.1 A/µs,
recovery time < 5 ms
Rise Time < 50 ms
Set Point Tolerance V1:
+
/
-
2%; V2, V3, V4:
+
/
-
5%
Over Current Protection 110 to 170%
Over Voltage Protection 6.2 V
+
/
-
0.4 V for 5 V
Short Circuit Protection Short term, autorecovery
Switching Frequency Boost converter: 45 kHz typical
Resonant converter: 45 kHz typical
Operating Temperature 0 to 70°C, refer derating curve
Storage Temperature
-
40 to
+
85°C
Relative Humidity 95% Rh, noncondensing
Altitude Operating: 10,000 ft.; Nonoperating: 40,000 ft.
MTBF 1.02m Hours, Telcordia SR332 Issue-3
Isolation Voltage Min. 4242 VDC between input to output
Cooling Convection
4EM-15-062 39-DE60-43931-002 / B
Innovaons in Power
2
LFVLT100
-
1001 V1=12 V 7.5 A 1.0 A 3%
LFVLT100
-
1002 V1=15 V 6.67 A 0.5 A 3%
LFVLT100
-
1003 V1=24 V 4.2 A 0.1 A 1.5%
LFVLT100
-
1004 V1=48 V 2.1 A 0.2 A 1.04%
LFVLT100
-
4000 V1=5.1 V, V2=12.25 V, V1=12.0 A, V2=4.0 A, V1=3.0 A, V2=0.1 A, V1, V2=1.5%
V3=
-
5 V, V4=
-
12 V V3=0.8 A, V4=0.8 A V3=0.0 A, V4=0.0 A V3=2%, V4=1.25%
LFVLT100
-
4001 V1=5.1 V, V2=24.5 V, V1=12.0 A, V2=2.0 A, V1=3.0 A, V2=0.1 A, 1%
V3=12 V, V4=
-
12 V V3=0.8 A, V4=0.8 A V3=0.0 A, V4=0.0 A
LFVLT100
-
4002 V1=5.1 V, V2=16 V, V1=12.0 A, V2=3.0 A, V1=3.0 A, V2=0.1 A, V1, V2, V4=1%
V3=
-
4.8 V, V4=
-
15.5 V V3=0.8 A, V4=0.8 A V3=0.0 A, V4=0.0 A V3=2%
LFVLT100
-
4003 V1=5.1 V, V2=12 V, V1=12.0 A, V2=4.0 A, V1=3.0 A, V2=0.1 A, 1%
V3=24 V, V4=
-
12 V V3=0.8 A, V4=0.8 A V3=0.0 A, V4=0.0 A
LFVLT80
-
CK metal cover
kit accessory
Notes
1. Single output models:
+
/
-
2.5% for 12 V,
+
/
-
3% for 15 and 24 V,
+
/
-
2% for 48 V.
Quad output models :
+
/
-
1% for V1;
+
/
-
5% for V2, V3, V4.
2. Maximum current per output channel. Do not exceed total output power rating.
3. Ripple is peak to peak with 20 MHz bandwidth and 10 µF (Tantalum capacitor) in parallel with a 0.1 µF capacitor at rated line voltage
and load ranges.
4. Power fail and power good signal on quad output models only.
5. Specifications are for nominal input voltage, 25°C and max. load unless otherwise stated.
6. Derate output power linearly to 80% from 90 VAC to 80 VAC input.
Model Number Voltage Max. Load2 Min. Load Ripple3
J1 Pin 1 AC NEUTRAL
Pin 2 AC LINE
Spade Connector EARTH
J2 Pin 1, 2, 3, 4 V1
Pin 5, 6, 7, 8 RTN
Pin 9, 10 V2
Pin 11 V3
Pin 12 V4
J3 Pin 1 RTN
Pin 2 POWER FAIL/GOOD
Connectors
4EM-15-062 39-DE60-43931-002 / B
33
AC Input Connector (J1) Molex: 26
-
60
-
4030 or equivalent
Mating: 09
-
50
-
3031; Pins: 08
-
50
-
0106
EARTH Molex: 19705
-
4301
Mating: 190030001
DC Output Connector (J2) Tyco: 1
-
640445
-
2 or equivalent
Mating: 1
-
647402
-
2; Pins: 3
-
647409
-
1
Signal Connector (J3) Molex: 22
-
23
-
2021 or equivalent
Mating: 22
-
01
-
2021
Dimensions 5.0 x 3.04 x 1.07 inches
(127.0 x 77.22 x 27.18 mm)
Weight 250 g
Mechanical Specifications
CE Mark Complies with LVD Directive
Conducted Emissions EN55022
-
B, CISPR22
-
B, FCC PART15
-
B, EN50082
-
1
Static Discharge EN61000
-
4
-
2, Level
-
3
RF Field Susceptibility EN61000
-
4
-
3, Level
-
3
Fast Transients/Bursts EN61000
-
4
-
4, Level
-
3
Radiated Emissions EN55022
-
B, CISPR22
-
B, FCC PART15
-
B
To be controlled in end system
Surge Susceptibility EN61000
-
4
-
5, Level
-
3
Harmonic current EN61000
-
3
-
2, Class A
EMC
Safety Standard(s) IEC60950
-
1 (ed.2), EN60950
-
1, UL60950
-
1 (2nd Edition),
CSA C22.2 No. 60950
-
1 (2nd Edition), Class 1 SELV
Approval Agency Nemko, UL, C
-
UL
Safety File Number(s) Nemko: P09210934
UL: E150565
Safety
Power Fail/Good Signal4 Signal goes high after a delay of 100 ms once main output is within regulation band.
Signal goes low 1.5 ms advance before output goes out of regulation due to mains failure
Signal
4EM-15-062 39-DE60-43931-002 / B
Innovaons in Power
4
Mechanical Drawing
0.82 [20.8]
MAXIMUM
1.073 [27.25]
0.04 [1.0]
3.04 [77.2]
2.55 [64.8] ±0.01[0.25]
MA XIMUM
J2
0.19 [4.8]
MAXIMUM
0.225 [5.7]
0.225 [5.7]
±0.01[0.25]
COMPONENT
HT BELOW PCB
COMPONENT
HT ABOVE PCB
1
2
1
CENTER PIN REMOVED
3.00 [76.2]
Ø 0.159 [Ø4.0]
4-PLS
4-PLS
Ø0.3127.9]
TOP/BOTTOM
MOUNTING
HARDWARE
CLEARANCE
5.00 [127.0]
4.550 [115.6]
2-L
1-N
J1
J3
PF
GND
ALL DIMENSIONS ARE IN INCHES [MM]
GEN. TOLERANCE: +/-0.02 [+/-0.5]
MECHANICAL OUTLINE DIMENSIONS
Derating Curve