HRP-75 75W Single Output with PFC Function series Features : Universal AC input / Full range Built-in active PFC function Withstand 300VAC surge input for 5 seconds Protections: Short circuit / Overload / Over voltage Protections: Over temperature (optional) Cooling by free air convection 1U low profile 38mm Built-in remote ON-OFF control No load power consumption<0.5W All using 105 long life electrolytic capacitors 5 years warranty SPECIFICATION MODEL OUTPUT HRP-75-3.3 HRP-75-5 HRP-75-7.5 HRP-75-12 HRP-75-15 HRP-75-24 HRP-75-36 HRP-75-48 DC VOLTAGE 3.3V 5V 7.5V 12V 15V 24V 36V 48V RATED CURRENT 15A 15A 10A 6.3A 5A 3.2A 2.1A 1.6A CURRENT RANGE 0 ~ 15A 0 ~ 15A 0 ~ 10A 0 ~ 6.3A 0 ~ 5A 0 ~ 3.2A 0 ~ 2.1A 0 ~ 1.6A RATED POWER 49.5W 75W 75W 75.6W 75W 76.8W 75.6W 76.8W RIPPLE & NOISE (max.) Note.2 80mVp-p 80mVp-p 100mVp-p 120mVp-p 150mVp-p 150mVp-p 200mVp-p 240mVp-p VOLTAGE ADJ. RANGE 4.7 ~ 5.8V 2.5% 7.1 ~ 9V 2.5% 11 ~ 13.8V 1.5% 14.2 ~ 18V 1.5% 21.6 ~ 28.8V 1.5% 32 ~ 39.6V 1.5% 45 ~ 55.2V 1.5% 3.1 ~ 3.8V VOLTAGE TOLERANCE Note.3 2.5% LINE REGULATION 1.0% 1.0% 1.0% 0.3% 0.3% 0.2% 0.2% 0.2% LOAD REGULATION 2.0% 2.0% 1.5% 1.0% 0.5% 0.5% 0.5% 0.5% SETUP, RISE TIME 1800ms, 25ms/230VAC HOLD UP TIME (Typ.) 50ms/230VAC Note.5 85 ~ 264VAC VOLTAGE RANGE FREQUENCY RANGE 47 ~ 63Hz INPUT POWER FACTOR (Typ.) PF>0.9/230VAC EFFICIENCY (Typ.) 77% AC CURRENT (Typ.) INRUSH CURRENT (Typ.) 1.2A/115VAC 35A/115VAC LEAKAGE CURRENT <1mA / 240VAC OVERLOAD PROTECTION OVER VOLTAGE 20ms/115VAC at full load 120 ~ 370VDC PF>0.95/115VAC at full load 82.5% 84% 87% 88% 88.5% 89% 89% 0.7A/230VAC 65A/230VAC 105 ~ 135% rated output power Protection type : Constant current limiting, switch to hiccup mode for Vo<50% of rated voltage, recovers automatically after fault condition is removed 6 ~ 7V 9.4 ~ 10.9V 14.4 ~ 16.8V 18.8 ~ 21.8V 30 ~ 34.8V 41.4 ~ 48.6V 57.6 ~ 67.2V 3.96 ~ 4.62V Protection type : Shut down o/p voltage, re-power on to recover REMOTE CONTROL 85 5 for 3.3V~15V; 80 5 for 24V~48V (TSW1 : detect on heatsink of power transistor) (optional) Protection type : Shut down o/p voltage , recovers automatically after temperature goes down RC+ / RC-: 0 ~ 0.8V = power on ; 4 ~ 10V = power off WORKING TEMP. -40 ~ +70 WORKING HUMIDITY 20 ~ 90% RH non-condensing OVER TEMPERATURE (OPTIONAL) FUNCTION 1800ms, 25ms/115VAC at full load (Refer to output load derating curve) ENVIRONMENT STORAGE TEMP., HUMIDITY -40 ~ +85 , 10 ~ 95% RH TEMP. COEFFICIENT 0.03%/ (0 ~ 50 VIBRATION 10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes UL60950-1, TUV EN60950-1 approved SAFETY STANDARDS SAFETY & EMC (Note 4) OTHERS WITHSTAND VOLTAGE ISOLATION RESISTANCE I/P-O/P:3KVAC HARMONIC CURRENT EMS IMMUNITY Compliance to EN61000-3-2,-3 Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024 , EN61000-6-2 , heavy industry level, criteria A MTBF 394.8K hrs min. DIMENSION 129*98*38mm (L*W*H) 0.47Kg; 30pcs/ 15Kg/ 0.97CUFT O/P-FG:0.5KVAC I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 EMI CONDUCTION & RADIATION Compliance to EN55022 (CISPR22) Class B PACKING NOTE I/P-FG:1.5KVAC / 70% RH MIL-HDBK-217F (25 ) 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to EMI testing of component power supplies. (as available on http://www.meanwell.com) 5. Derating may be needed under low input voltages. Please check the derating curve for more details. 6. Length of set up time is measured at cold first start. Turning ON/OFF the power supply may lead to increase of the set up time. http://store.iiic.cc/ File Name:HRP-75-SPEC 2010-11-29 HRP-75 75W Single Output with PFC Function Mechanical Specification Case No.903D series Unit:mm 31 3.5 7 122.5 9.5 1 2 =5 98 4 3L 85.5 M 2- 33 8.2 3 5 1 2 SVR1 CN100 3.5 4.5 73.5 Terminal Pin No. Assignment 129 6.5 Mating Housing Terminal JST XHP or equivalent JST SXH-001T or equivalent 3L =5 32 38 3.5 9.5 18.5 3-M 18 Assignment RCRC+ 3.5 12 max. Remote ON/OFF (CN100) : JST B-XH or equivalent Pin No. 1 2 120 28.5 Assignment DC OUTPUT -V DC OUTPUT +V Pin No. 4 5 9 Assignment AC/L AC/N FG Pin No. 1 2 3 77 Block Diagram ACTIVE INRUSH CURRENT LIMITING EMI FILTER I/P RECTIFIERS & PFC POWER SWITCHING O.T.P. O.L.P. RECTIFIERS & FILTER DETECTION CIRCUIT FG PFC CONTROL +V -V PWM CONTROL O.V.P. RC+ REMOTE CONTROL Derating Curve RC- Output Derating VS Input Voltage Ta = 25 100 100 90 80 80 230VAC Input only 70 LOAD(%) LOAD (%) 60 40 30 20 -40 -20 -40 -10 0 15 30 50 60 70 60 50 40 (HORIZONTAL) 85 100 125 135 155 264 INPUT VOLTAGE (V) 60Hz AMBIENT TEMPERATURE ( ) start up possible for 230VAC input http://store.iiic.cc/ File Name:HRP-75-SPEC 2010-11-29