Universal AC input / Full range
Built-in active PFC function
Protections: Short circuit / Overload / Over voltage
Protections: Over temperature (optional)
Built-in remote ON-OFF control
5 years warranty
Withstand 300VAC surge input for 5 seconds
Cooling by free air convection
1U low profile 38mm
No load power consumption<0.5W
All using 105 long life electrolytic capacitors
SPECIFICATION
HRP-75-3.3 HRP-75-5 HRP-75-7.5 HRP-75-12 HRP-75-15 HRP-75-24 HRP-75-36 HRP-75-48
MODEL
DCVOLTAGE
RATEDCURRENT
CURRENTRANGE
RATEDPOWER
RIPPLE&NOISE(max.) Note.2
OUTPUT VOLTAGE ADJ.RANGE
VOLTAGETOLERANCE Note.3
LINEREGULATION
LOADREGULATION
SETUP,RISETIME
HOLDUP TIME (Typ.)
VOLTAGERANGE Note.5
FREQUENCY RANGE
POWERFACTOR (Typ.)
EFFICIENCY (Typ.)
INPUT
ENVIRONMENT
INRUSHCURRENT (Typ.)
LEAKAGECURRENT
OVERTEMPERATURE(OPTIONAL)
SAFETY STANDARDS
HARMONICCURRENT
EMICONDUCTION&RADIATION
SAFETY &
EMSIMMUNITY
EMC
(Note4)
WITHSTANDVOLTAGE
ISOLATIONRESISTANCE
WORKINGTEMP.
WORKINGHUMIDITY
STORAGETEMP.,HUMIDITY
TEMP.COEFFICIENT
VIBRATION
MTBF
DIMENSIONOTHERS
NOTE
PACKING
OVERLOAD
OVERVOLTAGE
PROTECTION
ACCURRENT (Typ.)
3.3V 5V 7.5V 12V 15V 24V 36V 48V
15A 15A 10A 6.3A 5A 3.2A 2.1A 1.6A
0~15A 0~15A 0~10A 0~6.3A 0~5A 0~3.2A 0~2.1A 0~1.6A
49.5W 75W 75W 75.6W 75W 76.8W 75.6W 76.8W
80mVp-p 80mVp-p 100mVp-p 120mVp-p 150mVp-p 150mVp-p 200mVp-p 240mVp-p
3.1~3.8V 4.7~5.8V 7.1~9V 11~13.8V 14.2~18V 21.6~28.8V 32~39.6V 45~55.2V
2.5% 2.5% 2.5% 1.5% 1.5% 1.5% 1.5% 1.5%
1.0% 1.0% 1.0% 0.3% 0.3% 0.2% 0.2% 0.2%
2.0% 2.0% 1.5% 1.0% 0.5% 0.5% 0.5% 0.5%
1800ms,25ms/230VAC1800ms,25ms/115VACatfullload
50ms/230VAC20ms/115VACatfullload
85~264VAC120~370VDC
47~63Hz
PF>0.9/230VACPF>0.95/115VACatfullload
77% 82.5%
6~7V 9.4~10.9V 14.4~16.8V 18.8~21.8V 30~34.8V 41.4~48.6V 57.6~67.2V
84% 87% 88% 88.5% 89% 89%
1.2A/115VAC0.7A/230VAC
35A/115VAC65A/230VAC
<1mA /240VAC
105~135%ratedoutputpower
3.96~4.62V
Protectiontype:Constantcurrentlimiting,switchtohiccupmodeforVo<50%ofratedvoltage,recoversautomaticallyafterfaultcondition isremoved
Protectiontype:Shutdowno/pvoltage,re-powerontorecover
85 5 for3.3V~15V;80 5 for24V~48V(TSW1:detectonheatsinkofpowertransistor)(optional)
Protectiontype: ,recoversautomaticallyaftertemperaturegoesdownShutdowno/pvoltage
UL60950-1, TUVEN60950-1approved
CompliancetoEN55022(CISPR22)ClassB
Complianceto EN61000-3-2,-3
CompliancetoEN61000-4-2,3,4,5,6,8,11;ENV50204,EN55024 ,heavyindustrylevel,criteria A,EN61000-6-2
I/P-O/P:3KVACI/P-FG:1.5KVACO/P-FG:0.5KVAC
I/P-O/P,I/P-FG,O/P-FG:100MOhms/500VDC /25 /70%RH
-40~+70 (Refertooutputloadderatingcurve)
20~90%RHnon-condensing
-40~+85 ,10~95%RH
0.03%/ (0~50
10~500Hz,5G10min./1cycle,60min.eachalongX, Y,Zaxes
394.8Khrsmin.MIL-HDBK-217F(25 )
129*98*38mm(L*W*H)
0.47Kg;30pcs/15Kg/0.97CUFT
Features :
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives.
5. Derating may be needed under low input voltages. Please check the derating curve for more details.
6. Length of set up time is measured at cold first start. Turning ON/OFF the power supply may lead to increase of the set up time.
For guidance on how to perform these EMC tests, please refer to EMI testing of component power supplies.
(as available on http://www.meanwell.com)
HRP-75 series
75WSingleOutputwithPFCFunction
REMOTECONTROL
RC+/RC-:0~0.8V=poweron;4~10V=poweroff
FUNCTION
FileName:HRP-75-SPEC2010-11-29
http://store.iiic.cc/