HWS50-1500/HD Single Output Industrial Power Supplies Limited Lifetime Warranty -10 to +71C Operation (-40C start up) Universal Input (85 - 265VAC) Conformally coated pcbs Class 1 Div 2 option (/RYHD suffix) Key Market Segments & Applications Factory Automation LED Displays Features and Benefits Feature Limited Lifetime Warranty Conformally coated pcbs Wide range AC Input Test & Measurement Benefit Lower Cost of Ownership Operation in harsh environments Supports global use Specifications MODELS HWS50 HWS100 HWS150 HWS300 HWS600 HWS1000 HWS1500 ITEMS Input Voltage range (47-63Hz) 85-265VAC or 120-370VDC 85-265VAC or 120-330VDC (No DC input for HWS1500) Input Current (Typ) (1) A 0.7 / 0.35 1.3 / 0.65 1.9 / 0.95 4.1 / 2.1 8.1 / 3.9 13.5 / 7 19 / 10 Inrush Current (1) A 14 / 28 20 / 40 Power Factor Meets EN61000-3-2 Temperature Coefficient <0.02%/C Overcurrent Protection >104% Overvoltage Protection V Yes (See table on page 2) Hold Up Time (Typ) ms 20 Leakage Current (60Hz) mA <0.5mA <0.75mA <1.2mA 1.5mA Remote Sense No Yes Indicator Green LED = ON Remote On/Off No Yes (Isolated from output) Parallel operation No Single wire connection (5 units max) DC Good No Yes Remote Adjust (PV) No Yes (3) Operating Temperature HWS50-150: -10C to +71C, (-10 ~+50C: 100%, +60C: 60%, +71C: 20%) and Derating (operation to HWS300-1500: -10C to +71C, (-10 ~+50C: 100%, derate linearly to 50% load from +50 to +71C) +74C - contact factory) Guaranteed start up at -40C (see specification sheets on website for details and derating) Storage Temperature C -40 to +85C Humidity (non condensing) Operating: 30 - 90%RH (10 -90% on HWS300-1500), Non operating 10 - 95%RH Cooling Convection Internal fan Withstand Voltage (2) Input to Ground 2kVAC, Input to Output 3kVAC, Output to Ground 500VAC for 1 min. Isolation Resistance >100M at 25C & 70%RH, Output to Ground 500VDC, >10M Output to remote on/off 100VDC Vibration (non operating) MIL-STD-810F 514.5 Category 4, 10 (HWS1500 Cat 4, figure 514.5C-1) Shock (in packaging) MIL-STD-810F 516.5 Category I, VI (HWS1500 <196.1m/s2) Safety Agency Approvals UL60950-1, CSA60950-1, EN60950-1, EN50178, CE Mark Line Dip Complies with SEMI F47 (200VAC line only) Conducted & Radiated EMI EN55011 / EN55022-B, FCC-B, VCCI-B (HWS1500 Class A) Immunity IEC61000-4-2 (Level 2,3), -3, -4, -6, (Level 3), -5, -8 (Level 4), -11 Weight (Typ) g 280 450 500 1000 1600 3200 3800 Size (WxHxD) in 1.04x3.23x4.72 1.1x3.23x6.3 1.46x3.23x6.3 2.4x3.23x6.5 3.94x3.23x6.5 5x3.2x9.5 5x3.25x11 Warranty yr Limited lifetime warranty (See Lambda's terms & conditions) (1) (2) 100/200VAC input HWS300-600 2.5kVAC Input to ground (3) (*) 1-6V program voltage input to adjust output 20-120% (typical) of nominal. See instruction manual for details & models with this feature. Class 1 Div 2 option (/RYHD suffix) 3055 Del Sol Blvd * San Diego, CA 92154 * 1-800-LAMBDA-4 45 HWS50-1500/HD Output Ratings Model HWS50-3/HD HWS100-3/HD HWS150-3/HD HWS300-3/HD HWS600-3/HD HWS1000-3/HD HWS1500-3/HD HWS50-5/HD HWS100-5/HD HWS150-5/HD HWS300-5/HD HWS600-5/HD HWS1000-5/HD HWS1500-5/HD HWS1000-6/HD HWS1000-7/HD HWS50-12/HD HWS100-12/HD HWS150-12/HD HWS300-12/HD HWS600-12/HD HWS1000-12/HD HWS1500-12/HD HWS50-15/HD HWS100-15/HD HWS150-15/HD HWS300-15/HD HWS600-15/HD HWS1000-15/HD HWS1500-15/HD HWS50-24/HD HWS100-24/HD HWS150-24/HD HWS300-24/HD HWS600-24/HD HWS1000-24/HD HWS1500-24/HD HWS1000-36/HD HWS1500-36/HD HWS50-48/HD HWS100-48/HD HWS150-48/HD HWS300-48/HD HWS600-48/HD HWS1000-48/HD HWS1500-48/HD HWS1000-60/HD Voltage Adjust Range Max Curr(A) Peak Curr(A)4 3.3V 3.3V 3.3V 3.3V 3.3V 3.3V 3.3V 5V 5V 5V 5V 5V 5V 5V 6V 7.5V 12V 12V 12V 12V 12V 12V 12V 15V 15V 15V 15V 15V 15V 15V 24V 24V 24V 24V 24V 24V 24V 36V 36V 48V 48V 48V 48V 48V 48V 48V 60V 2.97 - 3.96 2.97 - 3.96 2.97 - 3.96 2.64 - 3.96 2.64 - 3.96 2.64 - 3.96 2.64 - 3.96 4.0 - 6.0 4.0 - 6.0 4.0 - 6.0 4.0 - 6.0 4.0 - 6.0 4.0 - 6.0 4.0 - 6.0 4.8 - 7.2 6.0 - 9.0 9.6 - 14.4 9.6 - 14.4 9.6 - 14.4 9.6 - 14.4 9.6 - 14.4 9.6 - 14.4 9.6 - 14.4 12.0 - 18.0 12.0 - 18.0 12.0 - 18.0 12.0 - 18.0 12.0 - 18.0 12.0 - 18.0 12.0 - 18.0 19.2 - 28.8 19.2 - 28.8 19.2 - 28.8 19.2 - 28.8 19.2 - 28.8 19.2 - 28.8 19.2 - 28.8 28.8 - 43.2 28.8 - 43.2 38.4 - 52.8 38.4 - 52.8 38.4 - 52.8 38.4 - 52.8 38.4 - 52.8 38.4 - 52.8 38.4 - 52.8 48.0 - 66.0 10 20 30 60 120 200 300 10 20 30 60 120 200 300 167 134 4.3 8.5 13 27 53 88 125 3.5 7 10 22 43 70 100 2.2 4.5 6.5 14 27 46 65/70 (1) 30.7 42/46.5(2) 1.1 2.1 3.3 7 13 28 32 18.4 160 100 80 16.5 31 58.5 105 39 70 29.2 23.4 Description Blank No Cover (HWS50-150 Only) HWS300-1500 the cover is fitted as standard The cover option for HWS50-150 is NOT available on /HD series HWS300-1500 the cover is fitted as standard ISA 12.12.01 (UL1604) - Class 1 Div 2 with dry contact relay DC Good signal (300W, 600W and 1500W 24V output models only, no remote on/off function.) 46 40 40 40 30 30 40 60 40 40 40 30 30 40 60 60 60 96 96 96 72 72 100 72 120 120 120 90 90 120 90 192 192 192 144 144 150 144 150 150 384 384 384 288 288 300 288 360 20 20 20 20 20 20 36 20 20 20 20 20 20 36 36 36 48 48 48 48 48 48 48 60 60 60 60 60 60 60 96 96 96 96 96 96 96 144 144 192 192 192 192 192 192 192 240 120 120 120 120 120 120 150 120 120 120 120 120 120 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 200 200 200 200 200 200 350 350 200 200 400 Efficiency (typ)%1 4.13-4.95 4.13-4.95 4.13-4.95 4.13-4.95 4.13-4.95 4.12-4.62 4.12-4.62 6.25-7.25 6.25-7.25 6.25-7.25 6.25-7.25 6.25-7.25 6.25-7 6.25-7 7.5-8.4 9.37-10.5 15-17.4 15-17.4 15-17.4 15-17.4 15-17.4 15-17.4 15-17.4 18.8-21.8 18.8-21.8 18.8-21.8 18.8-21.8 18.8-21.8 18.7-21.8 18.7-21.8 30-34.8 30-34.8 30-34.8 30-34.8 30-34.8 30-34.8 30-34.8 45-49.7 45-49.7 55.2-64.8 55.2-64.8 55.2-64.8 55.2-64.8 55.2-64.8 55.2-60 55.2-64.8 69-75 76/78 78/81 78/81 74/77 75/78 71/73 72/75 82/84 83/86 83/86 79/82 80/83 76/78 77/81 79/81 80/82 81/83 83/86 83/86 80/83 80/83 82/85 82/85 81/83 83/86 83/86 80/83 81/84 83/85 83/87 82/84 84/87 85/88 82/85 82/85 85/87 84/88 85/88 84/88 83/85 84/87 85/88 82/85 83/86 86/88 86/90 85/88 200-265VAC Input, 10s maximum on time, 35% duty cycle Other Lambda Industrial Products Suffix /RYHD 33 66 99 198 396 660 990 50 100 150 300 600 1000 1500 1002 1005 51.6 102 156 324 636 1056 1500 52.5 105 150 330 645 1500 1500 52.8 108 156 336 648 1104 1560 1104 1512 52.8 100.8 158.4 336 624 1104 1536 1104 (4) Options /A Max Load Line Ripple Overvoltage Power(W) Reg(mV) Reg(mV) Noise(mV) (V) LZSA DPP, DLP, DSP PFE 500W to 1500W Single output 10W to 480W DIN Rail Mount 300 to 1000W AC-DC Power Models For Additional Information, please visit us.tdk-lambda.com/lp/products/hws-series.htm 3055 Del Sol Blvd * San Diego, CA 92154 * 1-800-LAMBDA-4 Revision B2: May 2009