Series CD 2A, 60Vdc Optically Isolated, Short-Circuit Protected DC Solid-State Relay Part* DESC Drawing Number CD00CFW CD00CFY Basic Solid-State Relay (SSR) 90091-008 CD01CFW CD01CFY Relay Description Number SSR with Control Status 90091-006 FEATURES CD20CDW SSR with Short-Circuit Protection ELECTRICAL SPECIFICATIONS * Available with short circuit/current overload protection * Available with input status monitor * TTL and CMOS compatible control * Low ON resistance power FET output * Fast switching speed * Meets 28 Vdc system requirements of MIL-STD-704 * Optical isolation * Low profile hermetic ceramic package * Built and tested to the requirements of MIL-PRF-28750 (-55C TO +105C UNLESS OTHERWISE NOTED) DESCRIPTION CD20CDY 90091-004 CD21CDW CD21CDY SSR with Short-Circuit Protection 90091-002 and Control Status * The Y suffix denotes parameters tested to MIL-PRF-28750 specifications. The W suffix denotes parameters tested to Teledyne specifications. For surface mount (SMT), add "S" prefix to part number. Example: SCD00CFW INPUT (CONTROL) SPECIFICATION When used in 2 terminal configuration Min (TTL or direct control) (See Fig. 1) Input Current @ VIN = 5 Vdc (See Fig. 2) Typ 14 Turn-Off Voltage (Guaranteed Off) Turn-On Voltage (Guaranteed On) 15 mA 1.5 Vdc 3.8 Vdc Reverse Voltage Protection Input Supply Range (See Note 4) Max Units 3.8 -32 Vdc 6 Vdc INPUT (CONTROL) SPECIFICATION When used in 3 terminal configuration (CMOS or open collector TTL) (See Fig. 1) Min Typ Max Units Control Current VCONTROL = 5 Vdc 250 A VCONTROL = 18 Vdc 1 mA 0 18 Vdc 3.8 6 Vdc 15 mA Control Voltage Range Bias Supply Voltage (See Note 4) Bias Supply Current @ VBIAS = 5 Vdc Turn-Off Voltage (Guaranteed Off) Turn-On Voltage (Guaranteed On) (c) 2002 TELEDYNE RELAYS 14 3.2 Vdc 0.3 Vdc This all solid-state relay utilizes the latest technology to provide a low ON resistance. The control (input) and load (output) are optically isolated to protect input logic circuits from voltage and current transients which can occur on the output supply. The optical isolation also provides a full floating output, thus allowing the load to be connected to either output terminal. The control circuit is buffered to enable the relay to be driven directly from standard CMOS or open collector TTL logic circuits. Available options include short circuit and current overload protection, which provides complete protection for both the relay and the system wiring. This feature not only provides protection should a short or overload occur while the relay is on, but will also provide protection should the relay be switched into a short. In either case, the relay will sense the short circuit condition and then block it indefinitely until the short is removed and the unit is reset by cycling the input control. The second option is a status output, which provides a built-intest function. This feature checks the input circuitry of the relay and provides a logic (0) low when the input circuit is turned on and operational. Both options are available either together or separately as standard features. (800) 284-7007 * www.teledynerelays.com CD 41 CD\072002\Q1 Series CD OUTPUT (LOAD) SPECIFICATIONS (See Note 2) Min Typ BLOCK DIAGRAM (BOTTOM VIEW) Max Units Continuous Load Current (See Fig. 3) CD20CD 1.0 Adc CD21CD 1.0 Adc CD00CF 2.0 Adc CD01CF 2.0 Adc 40 Adc 0.6 Vdc CD21CD 0.6 Vdc CD00CF 0.75 Vdc CD01CF 0.75 Vdc Continuous Operating Load Voltage 60 Vdc Transient Blocking Voltage (See Note 3) 80 Vdc Leakage Current @ VLOAD = 60 Vdc Output Voltage Drop CD20CD ON Resistance Rds (on) at TJ = 25C ILOAD = 100 mAdc (See Fig. 4) CD20CD 0.36 0.45 Ohm CD21CD 0.36 0.45 Ohm CD00CF 0.16 0.22 Ohm CD01CF 0.16 0.22 Ohm Turn-On Time (See Fig. 5) 1.5 ms Turn-Off Time (See Fig. 5) 0.25 ms Electrical System Spike 600 Vdc Output Capacitance at 25 Vdc, 100 KHz 475 pF Input to Output Capacitance 10 pF Dielectric Strength Insulation Resistance @ 500 Vdc 1000 Vac 109 Ohm MECHANICAL SPECIFICATIONS Maximum Junction Temperature (TJ Max) CD00 150 C CD01 150 C Thermal Resistance Junction to Ambient (JA) 80 C/W Thermal Resistance Junction to Case (JC) 20 C/W STATUS OUTPUT SPECIFICATIONS (CD01CF AND CD21CD) Min Typ Max Units Status Supply Voltage (See Note 7) 30 Vdc Status Leakage Current @ 15 Vdc 4 Adc Status (sink) Current (VSO < 0.3 Vdc) 2 mAdc CD 42 SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE (c) 2002 TELEDYNE RELAYS CD\072002\Q1 Series CD SHORT CIRCUIT SPECIFICATIONS (CD20CD AND CD21CD) Min Typ Surge Current (See Fig. 7 and Note 6) Max Units 2.4 Adc ENVIRONMENTAL SPECIFICATIONS Min Typ Max Units Temperature Range Operating -55 +105 C Storage -55 +125 C Vibration, 100 g 10 3000 Hz Constant Acceleration 5000 g Shock, 0.5 ms 1500 g TABLE 1: STATUS OUTPUT TRUTH TABLE (CD01CF AND CD21CD) Control Voltage Output Status Status Output Level High Off High (VSO = VSTATUS) Low On Low (VSO) 0.3 Vdc) INPUT CURRENT VS VOLTAGE FIGURE 2 (SEE NOTE 4) WIRING CONFIGURATIONS FIGURE 1 (SEE NOTE 8) LOAD CURRENT DERATING CURVE FIGURE 3 (c) 2002 TELEDYNE RELAYS (800) 284-7007 * www.teledynerelays.com CD 43 CD\072002\Q1 Series CD NORMALIZED ON RESISTANCE VS JUNCTION TEMPERATURE FIGURE 4 (SEE NOTE 5) SERIES LIMIT BIAS RESISTOR VS BIAS VOLTAGE FIGURE 8 (SEE NOTE 4) NOTES: 1. 2. 3. 4. OUTPUT TURN-ON AND TURN-OFF TIMING FIGURE 5 5. 6. 7. TRIP CURRENT VS TIME FIGURE 7 (SEE NOTE 6) 8. CD 44 Control input is compatible with CMOS or open collector TTL (with pull up resistor). The rated input voltage is 5V for all tests unless otherwise specified. Transient blocking voltage tests are performed per MIL-STD-704 (28 Vdc systems). For bias voltages above 6V, a series resistor is required. Use the standard resistor value equal to or less than the value found from Figure 8. To calculate the maximum ON resistance for a given junction temperature, find the normalized ON resistance factor (NR) from Figure 4. Calculate the new ON resistance as follows: (CD00CD, CD01CD) R(ON) = NR * RON @ 25C (CD20CD, CD21CD) R(ON) = 0.2 * NR + 0.21 Overload testing to the requirements of MIL-PRF-28750 is constrained to the limits imposed by the short circuit protection characteristics as defined in this specification. System series inductance for "shorted-load" mode of operation should be 30 H maximum. Maximum repetition rate into a shorted load should not exceed 10 Hz. A status pull up resistor is required for proper operation of the status output. Determine the current (Iso) required by the status interface. Calculate the current (Is) through the status resistor such that the sink current through the status output is 2 mA. Select the status resistor such that it does not allow more than 2 mA to flow through the status output. RSTATUS = VSTATUS - 0.3V 2 mA - Iso Inductive loads should be diode suppressed. Input transitions should be 1 ms duration and the input drive should be a bounceless contact type. SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE (c) 2002 TELEDYNE RELAYS CD\072002\Q1