WITHSTANDVOLTAGE
ISOLATIONRESISTANCE
I/P-O/P:3.75KVACI/P-FG:1.88KVACO/P-FG:0.5KVAC
I/P-O/P,I/P-FG,O/P-FG:100MOhms/500VDC/25 /70%RH
CONSTANTCURRENTREGION Note.4
CLG-150-12 A
A : IP65 rated. Output voltage and constant current level can be adjusted through internal potential meter.
Blank : IP67 rated. Cable for I/O connection.
B : IP67 rated. Constant current level adjustable through output cable.
C : Terminal block for I/O connection. Output voltage and constant current level can be adjusted through internal
potential meter.
SPECIFICATION
MODEL CLG-150-12 CLG-150-15 CLG-150-20 CLG-150-24 CLG-150-30 CLG-150-36 CLG-150-48
DCVOLTAGE
RATEDCURRENT
RATEDPOWER
OUTPUT
VOLTAGE ADJ.RANGE Note.6
CURRENT ADJ.RANGE
LINEREGULATION
LOADREGULATION
SETUP,RISETIME
HOLDUP TIME (Typ.)
VOLTAGERANGE Note.5
FREQUENCY RANGE
POWERFACTOR
EFFICIENCY (Typ.)
ACCURRENT
INPUT
INRUSHCURRENT(max.)
LEAKAGECURRENT
SAFETY STANDARDS Note.7
HARMONICCURRENT
EMSIMMUNITY
WORKINGTEMP.
WORKINGHUMIDITY
STORAGETEMP.,HUMIDITY
TEMP.COEFFICIENT
VIBRATION
MTBF
DIMENSIONOTHERS
NOTE
PACKING
OVERCURRENT(Typ.) Note.4
OVERVOLTAGE
OVERTEMPERATURE
12V
9~12V
15V
11.25~15V
20V
15~20V
24V
18~24V
30V
22.5~30V
36V
27~36V
48V
36~48V
11A 9.5A 7.5A 6.3A 5A 4.2A 3.2A
132W 142.5W 150W 151.2W 150W 151.2W 153.6W
150mVp-p 150mVp-p
13~17V
150mVp-p
17~22V
150mVp-p
22~27V
150mVp-p
26~32V
150mVp-p
31~41V
200mVp-p
40~56V
2.0%
5.5~11A
2.0%
4.75~9.5A
2.0%
3.75~7.5A
1.0%
3.15~6.3A
1.0%
2.5~5A
1.0%
2.1~4.2A
1.0%
1.6~3.2A
9~13V
Canbeadjusted byinternalpotentialmeterorthroughoutputcable
0.5% 0.5% 0.5% 0.5% 0.5% 0.5% 0.5%
1.0% 1.0% 1.0% 0.5% 0.5% 0.5% 0.5%
3000ms,80ms atfullload230VAC/115VAC
50ms/230VAC16 atfullloadms/115VAC
90~295VAC127~417VDC
47~63Hz
PF 0.95/230VACPF 0.98/115VACatfullloadandratedoutputvoltagePF 0.9at75~100%load
88% 88% 90% 90% 91% 91% 91%
13.5~16V 18~20V 23~27V 28~34V 33~36V 42~48V 57~65V
2A /115VAC1A /230VAC
COLDSTART 65A/230VAC
<1mA /240VAC
95~108%
Protectiontype:Constantcurrentlimiting,recoversautomaticallyafterfaultconditionisremoved
Complianceto EN61000-3-2ClassC( 75%load);EN61000-3-3
CompliancetoEN61000-4-2,3,4,5,6,8,11;ENV50204,EN61547,EN55024,lightindustrylevel(surge4KV),criteria A
20~95%RH non-condensing
-40~+80 ,10~95%RH
0.03%/ (0~50 )
10~500Hz,5G12min./1cycle,periodfor72min.eachalongX, Y,Zaxes
UL1012;EN61347-1,EN61347-2-13independent(exceptforCLG-150Ctype);UL60950-1, TUVEN60950-1; J61347-1,
J61347-2-13,IP65orIP67approved
303.7Khrsmin.MIL-HDBK-217F(25 )
222.2*68*38.8mm(L*W*H)(CLG-150-Blank/A/B)229*68*38.8mm(L*W*H)(CLG-150-C)
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Constant current operation region is within 75% ~100% rated output voltage. This is the suitable operation region for LED related applications, but please
reconfirm special electrical requirements for some specific system design.
5. Derating may be needed under low input voltages. Please check the for more details.
6. Type A and type C only.
7. Safety and EMC design refer to EN60598-1, subject 8750(UL), CNS15233, GB7000.1, FCC part18.
8
static characteristics
. The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the
complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.
1.0Kg;12pcs/13Kg/0.49CUFT(CLG-150-Blank/A/B)1Kg;12pcs/13Kg/0.96CUFT(CLG-150-C)
Protectiontype: Shutdownandlatchoffo/pvoltage,re-powerontorecover
150WSingleOutputSwitchingPowerSupply
Universal AC input / Full range (up to 295VAC)
Protections: Short circuit / Overload / Over voltage / Over temperature
Built-in active PFC function
Cooling by free air convection
OCP point adjustable through output cable or internal potential meter
Suitable for LED lighting and moving sign applications
IP65 / IP67 design for indoor or outdoor installations
Compliance to worldwide safety regulations for lighting
3 years warranty
High efficiency 92%
Features :
CLG-150 seri es
RIPPLE&NOISE(max.) Note.2
VOLTAGETOLERANCE Note.3
ENVIRONMENT
EMICONDUCTION&RADIATION
SAFETY &
EMC
PROTECTION
100 10 (RTH2)
Protectiontype:Shutdowno/pvoltage,re-powerontorecover
-30~+70 (Refertooutputloadderatingcurve)
F110 SELV
IP65 IP67
SHORTCIRCUIT
Hiccupmode,recoversautomaticallyafterfaultconditionisremoved
CompliancetoEN55015,EN55022(CISPR22)ClassB
PS
E
http://store.iiic.cc/
MechanicalSpecification
FileName:CLG-150-SPEC 2011-01-17
CaseNo. Unit:mm954A
Blank:(CLG-150)
IP67rated.CableforI/Oconnection.
300 20
FG(Green/Yellow)
14AWG 2C
38.8
18AWG 3C
222.2
198.2
AC/L(Brown)
AC/N(Blue)
12
9.6
9.4
9.4 34.2
68
4.2 4PL
300 20
+V(Red)
-V(Black)
150WSingleOutputSwitchingPowerSupply CLG-150 s erie s
A Type:(CLG-150-_A)
IP65rated.Outputvoltageandconstantcurrentlevelcanbeadjustedthroughinternalpotentialmeter.
(Canaccessbyremovingtherubberstopperonthecase.)
300 20
FG(Green/Yellow)
14AWG 2C
38.8
18AWG 3C
222.2
198.2
AC/L(Brown)
AC/N(Blue)
12
9.6
9.4
9.4 34.2
68
4.2 4PL
Io ADJ.
Vo ADJ.
300 20
+V(Red)
-V(Black)
http://store.iiic.cc/
ACInput TerminalPinNo.
Assignment
DCOutput TerminalPinNo.
Assignment
PinNo.
PinNo.
1
1
3
2
2
Assignment
Assignment
AC/N
-V
+V
AC/L
FG
BType:(CLG-150-_B)
IP67rated.Outputconstantcurrentlevelcanbeadjustedthroughoutputcablebyconnectingaresistorbetween ADJ1and ADJ2.
Referenceresistancevalueforoutputcurrentadjustment(Typical)
Resistance
Open
4.7K
620
82
Short
Percentageofratedcurrent
Slightly>100%
100%
75%
50%
Slightly<50%
300 20
FG(Green/Yellow)
14AWG 2C
18AWG 2C
38.8
18AWG 3C
222.2
198.2
AC/L(Brown)
AC/N(Blue)
12
9.6
9.4
9.4 34.2
68
4.2 4PL
300 20
+V(Red)
ADJ1(Blue)
-V(Black)
ADJ2(White)
CType:(CLG-150-_C)
Outputvoltageandconstantcurrentlevelcanbeadjustedthroughinternalpotentialmeter.
(Canaccessbyremovingtherubberstopperonthecase.)
4.2 4PL
38.8
37
68
7.5 9.5
I/P
8
15.4
1
2
3
88
198.2
229
1
2O/P
Io ADJ.
Vo ADJ.
FileName:CLG-150-SPEC 2011-01-17
150WSingleOutputSwitchingPowerSupply CLG - 150 s erie s
http://store.iiic.cc/
FileName:CLG-150-SPEC 2011-01-17
150WSingleOutputSwitchingPowerSupply CLG - 150 s erie s
ADJ1
(B Type)
ADJ2
Fosc:100KHz
fosc:100KHz
DeratingCurve StaticCharacteristics
AMBIENTTEMPERATURE( )
LOAD(%)
-30 -25 -10 0 15 30 50 55 60 70
20
40
60
80
100
INPUTVOLTAGE(V)60Hz
90 100 125 135 145 155 165 175 180 200 230 295
100
90
80
70
60
50
40
LOAD(%)
(HORIZONTAL)
DETECTION
PWM&PFC CIRCUIT
O.L.P.
EMIFILTER
RECTIFIERS
POWER
SWITCHING
FILTER
&
RECTIFIERS +V
-V
I/P
FG
CONTROL
O.V.P.
&
O.L.P.
PFC
CIRCUIT
PFC
CONTROL
BlockDiagram
230VAC
100VAC
230VAC
Inputonly
http://store.iiic.cc/
0 . 7 8
0 . 8 0
0 . 8 2
0 . 8 4
0 . 8 6
0 . 8 8
0 . 9 0
0 . 9 2
0 . 9 4
0 . 9 6
0 . 9 8
1 . 0 0
5 0 % 6 0 % 7 0 % 8 0 % 9 0 % 1 0 0 %
230V
110V
68
70
72
74
76
78
80
82
84
86
88
90
92
94
10% 20% 30% 40% 50% 60% 70% 80% 90% 100%
230V
110V
CLG-150seriespossesssuperiorworkingefficiencythatupto91%canbereachedinfieldapplications.
EFFICIENCY (%)
LOAD
PowerFactorCharacteristic
Powerfactorwillbehigherthan0.9whenoutputloadingis75%orhigher.
EFFICIENCY vsLOAD(48VModel)
ConstantCurrentMode
PF
LOAD
TherearetwomajorkindsofLEDdrivemethod"directdrive"and"withLEDdriver".
A typicalLEDpowersupplymayeitherworkin"constantvoltagemode(CV)orconstantcurrentmode(CC)"todrivetheLEDs.
Mean Well's LED power supply with CV+ CC characteristic can be operated at both CV mode [with LED driver, at area (A)] and CC mode [direct drive, at area (B)].
DRIVINGMETHODSOFLEDMODULE
TypicalLEDpowersupplyI-Vcurve
Vo(%)
100
50
50 100
(max.)
Io (%)
Constant
Voltage area
Constant
Current area
Hiccup
Protection
(A)
(B)
(C)
FileName:CLG-150-SPEC 2011-01-17
150WSingleOutputSwitchingPowerSupply CLG - 150 s erie s
http://store.iiic.cc/