Type: DILM12-10(24VDC) Article No.: 276845 Ordering information Rated operational current AC-3 400 V Ie A 12 Max. rating for three-phase motors, 50 - 60 Hz AC-3 230 V P kW 3.5 Max. rating for three-phase motors, 50 - 60 Hz AC-3 400 V P kW 5.5 Max. rating for three-phase motors, 50 - 60 Hz AC-3 690 V P kW 6.5 Max. rating for three-phase motors, 50 - 60 Hz AC-4 230 V P kW 2 Max. rating for three-phase motors, 50 - 60 Hz AC-4 400 V P kW 3 Max. rating for three-phase motors, 50 - 60 Hz AC-4 690 V P kW 4.4 Ith = Ie A 20 Conventional thermal current I th = I e AC-1 Open DILM32-XHI.. DILA-XHI(V).. For use with General Standards IEC/EN 60947, VDE 0660, UL, CSA Lifespan, mechanical AC operated Operations x 106 10 DC operated Operations x 106 10 Operating frequency, mechanical AC operated Operations/h 9000 DC operated Operations/h 9000 Climatic proofing Ambient temperature 1 Damp heat, constant, to IEC 60068-2-78 Damp heat, cyclical, to IEC 60068-2-30 Open C -25/60 Enclosed C -25/40 Storage C -40/80 Mechanical shock resistance (IEC/EN 60068-2-27) Half-sinusoidal shock, 20 ms Main contacts Make contact g 10 Make contact g 7 Break contact g 5 Auxiliary contacts Protection type IP20 Protection against direct contact when actuated from front (IEC 536) Finger- and back-of-hand proof Weight AC operated kg 0,23 DC operated kg 0,28 Terminal capacity Main cable Solid mm2 1 x (0.75 - 4) 2 x (0.75 - 2.5) Flexible with ferrule mm2 1 x (0.75 - 2.5) 2 x (0.75 - 2,5) Solid or stranded AWG 18 - 14 Anschlussschraube Hauptleiter Tightening torque M3.5 Nm 1.2 Solid mm2 1 x (0.75 - 4) 2 x (0.75 - 2.5) Flexible with ferrule mm2 1 x (0.75 - 2.5) 2 x (0.75 - 2.5) Solid or stranded AWG 18 - 14 Terminal capacity Control circuit cables Anschlussschraube Hilfsleiter Tightening torque M3.5 Nm 1.2 Pozidriv screwdriver Size 2 Standard screwdriver mm 0.8 x 5.5 1x6 Pozidriv screwdriver Size 2 Standard screwdriver mm 0.8 x 5.5 1x6 Solid mm2 0.75 - 2.5 flexible mm2 0.75 - 2.5 flexible with ferrules mm2 0.75 - 2.5 Solid or stranded AWG 18 - 14 Tool Main cable Control circuit cables Terminal capacity Main cable Terminal capacity Control circuit cables 2 Solid mm2 Flexible mm2 0.75 - 2.5 Flexible with ferrule mm2 0.75 - 2.5 Solid or stranded AWG 18 - 14 0.75 - 2.5 Tool Stripping length mm 10 Screwdriver blade width mm 3,5 Main conducting paths Rated impulse withstand voltage Uimp V AC Overvoltage category/pollution degree 8000 III/3 Rated insulation voltage AC Ui V AC 690 Rated operational voltage Ue V AC 690 Safe isolation to VDE 0106 Part 101 and Part 101/A1 between coil and contacts V AC 400 between the contacts V AC 400 A 144 220/230 V A 120 380/400 V A 120 Making capacity (cos O to IEC/EN 60947) up to 690 V Breaking capacity 500 V A 100 660/690 V A 70 Component lifespan AC-3/AC-4 Tripping characteristics Maximum operating frequency AC-1; 400 V Ie Ops/h 800 AC-3; 400 V Ie Ops/h 1000 AC-4; 400 V Ie Ops/h 300 400 V gG/gL 500 V A 20 690 V gG/gL 690 V A 20 400 V gG/gL 500 V A 35 690 V gG/gL 690 V A 25 at 40 C Ith A 22 at 50 C Ith A 21 at 55 C Ith A 21 at 60 C Ith A 20 Short-circuit rating Short-circuit protection Maximum fuse Type "2" coordination Type "1" coordination AC AC-1 duty conv. therm. current 3-pole 50 - 60 Hz open 3 Enclosed Ith A 18 open Ith A 50 Enclosed Ith A 45 220/230 V Ie A 12 240 V Ie A 12 380/400 V Ie A 12 415 V Ie A 12 440V Ie A 12 500 V Ie A 10 660/690 V Ie A 7 220/230 V P kW 3,5 240V P kW 4 380/400 V P kW 5,5 415 V P kW 7 440 V P kW 7,5 500 V P kW 7 660/690 V P kW 6,5 220/230 V Ie A 7 240 V Ie A 7 380/400 V Ie A 7 415 V Ie A 7 440 V Ie A 7 500 V Ie A 6 660/690 V Ie A 5 220/230 V P kW 2 240 V P kW 2,2 380/400 V P kW 3 415 V P kW 3,4 440 V P kW 3,6 500 V P kW 3,5 660/690 V P kW 4,4 60 V Ie A 20 110 V Ie A 20 220 V Ie A 15 440 V Ie A 1,3 Conventional free air thermal current, 1-pole AC-3 duty Rated operational current AC-3 open, 50 - 60 Hz, 3-pole Motor rating AC-4 duty Rated operational current AC-4 open, 50 - 60 Hz, 3-pole Motor rating DC of three-phase capacitors open DC-1 operation 4 DC-3 operation 60 V Ie A 20 110 V Ie A 20 220 V Ie A 1,5 440 V Ie A 0,2 60 V Ie A 20 110 V Ie A 20 220 V Ie A 1,5 440 V Ie A 0,2 DC-5 operation Current heat loss (3-pole) Current heat loss at Ith W 4,7 Current heat loss at Ie to AC-3/400 V W 1,1 Impedance per pole m& 2,5 Pick-up x Uc 0,8 - 1,1 Abfall x Uc 0,3 - 0,6 Pick-up x Uc 0,8 - 1,1 Abfall x Uc 0,15-0,6 50 Hz Pick-up VA 24 50 Hz Pick-up W 19 50 Hz Sealing VA 4 Magnet systems Voltage tolerance AC operated AC operated Drop-out voltage AC operated Drop-out voltage AC operated DC operated DC operated DC operated DC operated Power consumption of the coil in a cold state and 1.0 x Uc 50 Hz Sealing W 1,2 60 Hz Pick-up VA 29 60 Hz Pick-up W 23 60 Hz Sealing 60 Hz Sealing VA 1,3 50/60 Hz Pick-up VA 28 26 50/60 Hz Pick-up W 22 21 50/60 Hz Sealing VA 4,6 3,9 50/60 Hz Sealing W 1,4 1,2 DC operated Pick-up W 4.5 DC operated Sealing W 4.5 % DF 100 Duty factor Switching times at 100 % Uc (approximate values) Main contacts 5 4,4 AC operated Closing delay ms 20 Opening delay ms 15 ms 35 DC operated Closing delay Opening delay ms 15 Arcing time ms 10 Electromagnetic compatibility (EMC) Emitted interference to EN 60947-1 Interference immunity to EN 60947-1 Mounting position Mounting position, AC- and DC operated Moeller GmbH, Hein-Moeller-Str. 7-11, D-53115 Bonn E-Mail: catalog@moeller.net, Internet: www.moeller.net, http://catalog.moeller.net Copyright 2005 by Moeller GmbH. Subject to modifications. HPL-C2005GB-INT V3.0 6