506
Dimensions are shown for
reference purposes only.
Dimensions are in inches over
(millimeters) unless otherwise
specified.
Specifications and availability
subject to change.
P&B
Catalog 1308242
Issued 3-03 (PDF Revised 8-06)
www.tycoelectronics.com
Technical support:
Refer to inside back cover.
Operate Data @ 25°C
Must Operate Voltage: 75% of nominal voltage or less.
Must Release Voltage: 10% of nominal voltage or more.
Operate Time (Including Bounce)§: 15 ms, max.
Release Time (Including Bounce)§: 15 ms, max.
§ At or From Nominal Coil Voltage
T9A series
DC Coil 30 Amp PC Board or
Panel Mount Relay
File E22575
File LR15734
Contact Ratings @ 25°C
Arrangements: 1 Form A (SPST-NO), and 1 Form C (SPDT).
Material: Silver-cadmium oxide.
Mechanical Life: 10 million operations, typical.
Minimum Contact Load: 1A @ 5VDC or 12VAC.
Initial Contact Resistance:
75 milliohms, max., @ min. rated current (switched).
Initial Dielectric Strength
Between Open Contacts: 1,500V rms.
Between Contacts and Coil: 2,500V rms.
6 kV surge using 1.2μs/50μs Impulse Wave or
.5μs – 100kHz Ring Wave
Initial Insulation Resistance
Between Mutually Insulated Elements: 109 ohms, min., @ 500VDC,
25°C and 50% R.H.
Coil Data @ 25°C
Voltage: 5 to 110VDC.
Nominal Coil Power: 1.0W, (approx.) and 900mW (approx.) versions.
Maximum Coil Power: 2.8 Watt.
Maximum Coil Temperature(5): Class F: 155°C.
Duty Cycle: Continuous.
Nominal DC Resistance Nominal
Voltage ± 10% (Ohms) Current (mA)
5 27 185
6 40 150
99793
12 155 77
15 256 59
18 380 47
20 450 44
22 545 40
24 660 36
28 890 31
36 1,450 25
48 2,560 19
110 13,450 8
Coil Data - 900mW
Coil Data - 1 Watt
Nominal DC Resistance Nominal
Voltage ± 10% (Ohms) Current (mA)
525200
636167
981111
12 144 83
15 225 67
18 324 56
22 484 45
24 576 42
48 2,304 21
110 12,100 9
Features
Up to 30 amp switching in SPST and 20 amp in SPDT arrangements.
Wash-tight (washable)(6), plastic case available.
Meets UL 873 and UL 508 spacing – 1/8" through air, 1/4" over surface.
Load connections made via 1/4" Q. C. terminals and safety wells accept
insulated female Q. C. terminals (mounting codes 2 & 5).
UL Class F insulation system standard.
• Well suited for various industrial, commercial and residential applications.
Typical Electrical Load & Life - 1 Watt Coil
Contact Contact Load Type of Load Operations
Arrangement
1 30A @ 240VAC UL General Purpose 100,000
25A @ 240VAC Resistive Heater 100,000
5 20A/10A @ 240VAC UL General Purpose 100,000
20A/10A @ 240VAC UL Resistive 100,000
20A/10A @ 28VDC Resistive 100,000
UL 508/873 & CSA Contact Ratings - 1 Watt Coil
Voltage Load Type N.O. Contact N.C. Contact
277VAC Tungsten * 5.4A
277VAC Ballast 10A 3A
240VAC Motor 2 HP 1/2 HP
240VAC Resistive *† 25A 20A
240VAC General Purpose† 30A 15A
240VAC LRA/FLA **†† 80A/30A 30A/12A
240VAC Pilot Duty * 470VA 275VA
125VAC Motor 1 HP 1/4 HP
120VAC LRA/FLA 98A/22A
120VAC Tungsten * 8.3A
120VAC Pilot Duty 470VA
28VDC Resistive 20A 10A
* Rated 6,000 operations.
** Higher UL & CSA ratings available.
For Form C application, derate current to 20A (N.O.), 10A (N.C.).
†† For Form C application, derate current to 67%.
Note: Consult factory for other 900mW version contact ratings.
Contact Ratings @ 25°C (unless otherwise noted) with relay
properly vented. Remove vent nib after soldering and cleaning.
Users should thoroughly review the technical data before selecting a product part
number. It is recommended that user also seek out the pertinent approvals files of
the agencies/laboratories and review them to ensure the product meets the
requirements for a given application.
UL 508/873 & CSA Contact Ratings - 900mW Coil
Voltage Load Type N.O. Contact N.C. Contact Operations
240VAC General Purpose 30A 100,000
240VAC Resistive 18A 100,000 @ 105°C
240VAC Resistive 15A 6,000
240VAC LRA/FLA 30A/15A 100,000
120VAC LRA/FLA 50A/16A 100,000
120VAC LRA/FLA 30A/11A 200,000
Note: Consult factory for other 900mW version contact ratings.
507
Dimensions are shown for
reference purposes only.
Dimensions are in inches over
(millimeters) unless otherwise
specified.
Specifications and availability
subject to change.
www.tycoelectronics.com
Technical support:
Refer to inside back cover.
P&B
Catalog 1308242
Issued 3-03 (PDF Revised 8-06)
Mechanical Data
Termination: Printed circuit and quick connect terminals (4).
Enclosures (all have 94V-0 flammability rating):
T9AP: Dust protected plastic case
T9AS: Wash-tight plastic case (washable) (2 & 3).
T9AV: Flux-proof plastic case.
Weight: Q.C. version: 1.2 oz. (33g) approx. (mounting code 2 & 5).
Wash-tight Model T9AS: 0.9 oz. (26g) approx. (mounting code 1).
Notes
(1) Operating ambient temperature must consider “Must Operate Voltage
Change Over Temperature,” Contact Temperature Rise, Coil Temperature
Rise (If coil is not allowed to cool) and Maximum Coil Temperature.
Specification ambient considers 20A load with coil cooled to ambient.
(2) Wash-tight relay terminals should not be bent.
(3) Remove knock-off nib after cleaning process for optimum life of wash-tight
relays.
(4) Maximum soldering temperature is 500°F for 4 seconds.
(5) Class F coils are UL systems approved for maximum coil temperature of
140°C, by change of resistance method.
(6) See application note 13C265 for proper relay mounting, termination,
cleaning and PC board conductor width. Coil rise test performed with 30A
PC board to maintain 20°C maximum rise @ 30A.
T9AP1D52-9
T9AP1D52-12
T9AP5D52-12
T9AP5D52-24
T9AS1D12-12
T9AS1D12-18
T9AS1D12-24
T9AS1D12-48
T9AS1D22-12
T9AS1D22-24
Our authorized distributors are more likely to maintain the following items in stock for immediate delivery.
0
20
40
60
80
100
120
140
1801601401201008060
0A
10A
20A
30A
Wash-Tight Relay, Vented
(note 3)
PC Terminals For Coil & Contacts
Applied Coil Voltage (% of Rated Voltage)
Max. Alowable
Ambient Temp. (°C)
40
60
80
100
120
140
1801601401201008060
Dust Protected Relay,
Flange Mount
0A
10A
20A
30A
Applied Coil Voltage (% of Rated Voltage)
Max. Alowable
Ambient Temp. (°C)
0
20
40
60
80
100
120
140
1801601401201008060
Wash-Tight Relay, Vented (note 3);
Load Connections Via Q.C. Terminals,
PC Mount
0A
10A
20A
30A
Applied Coil Voltage (% of Rated Voltage)
Max. Alowable
Ambient Temp. (°C)
Environmental Data
Storage Temperature Range: -55°C to 130°C.
Operating Temperature Range(1): -55°C to +85°C.
Vibration, Operational: 0.065" (1.65mm) max. excursions from 10-55 Hz.
with no contact opening >100μs.
Shock, Operational: 10g for 11 ms with no contact opening >100μs.
Shock, Mechanical: 100g.
Ambient Temperature vs. Coil Voltage - 1 Watt Coil
Data below are average values and should be verified in application. Tests
were conducted within a 2' (.6 m) cube (still air); at nominal coil power @
25°C; with normally open contact loaded; and with 4' (1.22 m) long, #10
AWG load wires. P.C. board relays were mounted to a 30A, single side P.C.
board (6).
Ordering Information
Typical Part Number BT9A S 5 D 2 2 -12
1. Basic Series:
T9A = Low cost, printed circuit board/panel power relay.
2. Enclosure:
P = Dust protected plastic case (mounting code 5).
S = Wash-tight (washable) plastic case with knock off nib (mounting codes 1 & 2).
V = Flux-proof plastic case (mounting code 1).
3. Contact Arrangement:
1 = 1 Form A (SPST-NO). 5 = 1 Form C (SPDT).
4. Coil Input:
D = DC voltage (1 Watt) L = DC voltage (900mW)
5. Mounting & Termination:
1 = Printed circuit board mounting; PC terminals for coil & contacts (a).
2 = Printed circuit board mounting; PC terminals for coil & contacts, and .250" (6.35mm) quick connects for contacts (b).
5 = Flanged mounting; .187" (4.75mm) quick connects for coil and .250" (6.35mm) quick connects for contacts (c).
6. Contact Material:
2 = Silver-cadmium oxide.
7. Coil Voltage:
5 = 5VDC 9 = 9VDC 15 = 15VDC 20 = 20VDC 24 = 24VDC 36 = 36VDC 110 = 110VDC
6 = 6VDC 12 = 12VDC 18 = 18VDC 22 = 22VDC 28 = 28VDC 48 = 48VDC
a) Only available with enclosure code “S” & “V”. b) Only available with enclosure code “S”. c) Only available with enclosure code “P”.
NOTE: All part numbers are RoHS compliant.
T9AS5D12-12
T9AS5D12-24
T9AS5D22-12
T9AS5D22-24
T9AV1L22-24
508
Dimensions are shown for
reference purposes only.
Dimensions are in inches over
(millimeters) unless otherwise
specified.
Specifications and availability
subject to change.
P&B
Catalog 1308242
Issued 3-03 (PDF Revised 8-06)
www.tycoelectronics.com
Technical support:
Refer to inside back cover.
T9AS/V – Mounting & Termination Code 1
.300
(7.62)
.100
(2.54)
.150
(3.81)
.500
(12.7)
.550
(13.97)
.700
(17.78)
.043 ± .003 DIA.
(1.09 ± .08)
.081 ± .005 DIA.
(2.06 ± .13)
.600
(15.24)
.212 MAX.
(5.38)
.078 ± .003 DIA.
(1.98 ± .08)
PC Board Layouts (Bottom Views)
T9AP/S – Mounting & Termination Code 2
.140 MAX.
(3.56) .250 MAX.
(6.35)
.300
(7.62)
.100
(2.54)
.150
(3.81)
.500
(12.7)
.550
(13.97)
.700
(17.78)
.043 ± .003 DIA.
(1.09 ± .08)
.081 ± .005 DIA.
(2.06 ± .13)
.600
(15.24)
.078 ± .003 DIA.
(1.98 ± .08)
T9AS/V – Mounting & Termination Code 1
Outline Dimensions
T9AP – Mounting & Termination Code 5
Wiring Diagrams (Bottom Views)
1 Form A
T9AS – Mounting & Termination Code 2
1 Form C
.187 x .020
(4.75 x .508)
QUICK
CONNECT
1.080 MAX.
(27.43)
1.980 MAX.
(50.29)
1.713 ± .010
(43.51 ± .25)
.071 (1.80) RAD. FOR #6 SCREW
1.280 MAX.
(32.51)
1.100 MAX.
(27.94)
.250 x .032
(6.35 x .81)
QUICK
CONNECT
NCNO
COM
Note: Recommended mounting screw torque is 4.0-5.0 lbs.in when #6 screw is used.
.032 x .062
(.81 x 1.57)
.045 x .045
(1.14 x 1.14)
.03
(.80)
2 PLACES
.250 x .032 QUICK
(6.35 x .81) CONNECT
NC NO
COM
1.280 MAX.
(32.51)
1.080 MAX.
(27.43)
.130 ± .020
(3.30 ± .51)
1.100 MAX.
(27.94)
Ø
.032 x .062
(.8 x 1.6)
TERMINALS
.212 MAX.
(5.38)
.10 MAX.
(2.54)
.045 x .045
(1.14 x 1.14)
TERMINAL
.805 MAX.
(20.4)
.69
(17.6)
1.280 MAX.
(32.51)
1.08 MAX.
(27.43)
.50
(12.8)
.03
(.80)
TERMINALS
.130 + .016
– .010
3.30 + .41
–.25
()
Ø
.016
(.43)