MAX6326/MAX6327/MAX6328/MAX6346/MAX6347/MAX6348
3-Pin, Ultra-Low-Power SC70/SOT
µP Reset Circuits
2 _______________________________________________________________________________________
ABSOLUTE MAXIMUM RATINGS
ELECTRICAL CHARACTERISTICS
(VCC = full range, TA= -40°C to +85°C, unless otherwise noted. Typical values are at TA= +25°C and VCC = 3V.) (Note 1)
Stresses beyond those listed under “Absolute Maximum Ratings” may cause permanent damage to the device. These are stress ratings only, and functional
operation of the device at these or any other conditions beyond those indicated in the operational sections of the specifications is not implied. Exposure to
absolute maximum rating conditions for extended periods may affect device reliability.
Terminal Voltage (with respect to GND)
VCC ...........................................................................-0.3V to +6V
RESET, RESET (push-pull) .........................-0.3V to (VCC + 0.3V)
RESET (open drain)..................................................-0.3V to +6V
Input Current (VCC).............................................................20mA
Output Current (RESET, RESET).........................................20mA
Rate of Rise (VCC) ...........................................................100V/µs
Continuous Power Dissipation (TA= +70°C)
3-Pin SC70 (derate 2.7mW/°C above +70°C)...............174mW
3-Pin SOT23 (derate 4mW/°C above +70°C)................320mW
Operating Temperature Range ...........................-40°C to +85°C
Storage Temperature Range .............................-65°C to +150°C
Lead Temperature (soldering, 10s) .................................+300°C
Note 1: Overtemperature limits are guaranteed by design and not production tested.
RESET Output Voltage
(MAX6327/MAX6347)
VOL
0.4ISINK = 3.2mA, VCC = VTH(MAX), VTH ≥4.5V
0.4
ISINK = 3.2mA, VCC ≥4.5V, reset not asserted,
VTH ≤4.38V
V
VOH ISOURCE = 50µA, VCC ≥1.2V, reset asserted
0.3
ISINK = 1.2mA, VCC ≥3.2V, reset not asserted,
MAX6327 only
0.8 ·VCC
0.8 ·VCC
ISOURCE = 500µA, VCC ≥2.1V, reset asserted
1.0 1.75
µA
0.5 1.0
Supply Current ICC
VCC = 5.5V, no load
Reset Threshold
VTH -VTH
VTH +
1.5% 1.5% VVTH VTH -VTH
VTH +
2.5% 2.5%
Table 1
TA= +25°C
TA= -40°C to +85°C
1.2 5.5
1.0 5.5
0.8 ·VCC
0.8 ·VCC
0.8 ·VCC
Open-Drain RESET Output
Leakage Current µA0.1
RESET Threshold
Hysteresis mV
9.5MAX6346/MAX6347/MAX6348
6.3MAX6326/MAX6327/MAX6328
VCC to Reset Delay 20 µsVCC = VTH to (VTH - 100mV)
PARAMETER SYMBOL MIN TYP MAX UNITS
ms100 185 280
VCC Range V
Reset Threshold Tempco ∆VTH/°C 40 ppm/°C
CONDITIONS
TA= 0°C to +70°C
TA= -40°C to +85°C
V
Reset Active Timeout Period
ISOURCE = 800µA, VCC = VTH(MAX), VTH ≥4.5V
RESET Output Voltage
(MAX6326/MAX6346) ISOURCE = 800µA, VCC = 4.5V, VTH ≤4.38V
VOH
ISOURCE = 500µA, VCC = 3.2V, MAX6326 only
MAX632_ only, VCC = 3.0V for VTH ≤2.93V,
VCC = 3.2V for VTH > 2.93V, no load
V
0.3ISINK = 1.6mA, VCC > 2.1V, reset asserted
RESET Output Voltage
(MAX6326/MAX6328/
MAX6346/MAX6348)
VOL 0.4ISINK = 100µA, VCC ≥1.2V, reset asserted