HK-A Series
3055 Del Sol Blvd • San Diego, CA 92154 • 1-800-LAMBDA-4 39
3 Year Warranty Lower Cost of Ownership
Adjustment potentiometer Reduces need for non standard models
Low profile Smaller end system size
Feature Benefit
Factory Automation Process Control, NC-Machining,
Automotive, Packaging Equipment,
Materials Handling,
Chemical Processing, Robots
Test & Measurement Burn-in & Test, Automated
Test, Instrumentation,
Measurement, Detection
Automated Service Vending Machines, Elevators,
Video Gaming, Point of Sale Equipment
3 Year Warranty
Small size
Approved to UL & CSA (cUL)
85 - 132VAC Input, 47-440Hz
±10% output adjustment
Key Market Segments & Applications
HK-A Features and Benefits
Single Output 115VAC Input Industrial Power Supplies
MODEL HK10A HK15A HK25A HK50A HK100A HK150A
ITEMS
Input Voltage range - 85 - 132VAC (47 - 440Hz) or 110 - 175VDC
Inrush Current (100VAC) A 20 30 15 30 15 15
Temperature Coefficient (Typ) - 1% (over operating temperature range)
Overcurrent Protection - >105%
Overvoltage Protection % >115% (Zener clamp) 115 to 135%
Hold Up Time (Typ at 100VAC) ms 20
Remote Sense - No Yes
LED Indicator - Green LED = On
Operating Temp (no cover) (1) - 0°C to +60°C, derate linearly to 50% load from 50°C to 60°C
Operating Temp (w/ cover) (1) - 0°C to +50°C, derate linearly to 50% load from 40°C to 50°C
Storage Temperature - -30 to +85°C
Operating Humidity - 30 - 90% RH (non condensing)
Storage Humidity - 10 - 95% RH (non condensing)
Cooling - Convection cooled
Withstand Voltage - I/P to Grnd, I/P to O/P 2kVAC (20mA), O/P to Grnd 500VAC (100mA) for 1 min.
Isolation Resistance - >100M at 25C & 70%RH, Output to Ground 500VDC
Vibration (non operating) - 10 - 55Hz (1 minute sweep), 19.6m/s2constant X, Y, Z 1 hour
Shock - < 196.1 m/s2
Safety Agency Approvals - UL60950-1, CSA C22.2 No. 60950-1 (cUL)
Conducted & Radiated EMI - FCC Class B, VCCI-B
Recommended EMI Filter - MAW12R522 MAW120122 MAW120222 MB1200
Weight (Typ) g 150 170 230 280 540 650
Size (WxHxD) in See sheet 2
Warranty - Three Years
Specifications
(1) Vertical mount as photo, HK100A & HK150A models operate to -10°C
See installation manual for full details, test methods of parameters and application notes