DC/DC Converter
URA_YMD-10WR3 & URB_YMD-10WR3 Series
2019.02.19-A/7 Page 1 of 6
MORNSUN Guangzhou Science & Technology Co., Ltd. reserves the copyright and right of final interpretation
10W isolated DC-DC converter in DIP package
Ultra-wide input and regulated dual/single output
CB Patent Protection RoHS
Ultra-wide 4:1 input voltage range
High efficiency up to 88%
No-load power consumption as low as 0.12W
I/O isolation test voltage1.5K VDC
Input under-voltage protection, output short
circuit, over-current, over-voltage protection
Operating ambient temperature range: -40℃~
Meets CISPR32/EN55032 CLASS A, without extra
Input reverse polarity protection available with
Chassis (A2S) or 35mm DIN-Rail mounting (A4S)
version
IEC60950, UL60950, EN62368 approved
Industry standard pin-out
URA_YMD-10WR3 & URB_YMD-10WR3 series of isolated 10W DC-DC converter products feature an ultra-wide with 4:1 input voltage with
efficiencies of up to 88%, 1500VDC input to output isolation, operating ambient temperature range of -40℃to +85℃, input under-voltage
protection, output over-voltage, over-current, short circuit protection. They meet CLASS A of CISPR32/EN55032 EMI standards without
external components, optional packages are offered for chassis or DIN-rail mounting (A2S, A4S), adding additional input reverse polarity
protection and they are widely used in applications such as industrial control, electric power, instruments and communication fields.
Full Load
Efficiency④(%)
Min./Typ.
1Use “A2S” suffix for chassis mounting and “A4S” suffix for DIN-Rail mounting;
2The A2S and A4S Model’s start-up and minimum input voltages are increased by 1VDC due to the input reverse polarity protection circuit;
3Exceeding the maximum input voltage may cause permanent damage;
4Efficiency is measured at nominal input voltage and rated output load; efficiencies for A2S and A4S Model’s is decreased by 2% due to the input reverse
polarity protection circuit;
5The specified maximum capacitive load value for positive and negative output is identical;
6Products marked with “*”need an input capacitor in order to meet conducted specifications of CISPR32/EN55032 CLASS A.