Rev. 01.01.2012
µMP Series
2 of 6
Embedded Power for
Business-Critical Continuity
313
process
yellow
3405
1797
1375
116
2607
652
242
2985
375
240
Output
Factory set point accuracy: ± 1%
Margining: ± 3 - 7% nominal analog (single output module only)
Overall regulation: 0.4% or 30 mV which ever is greater.
Ripple: RMS: 0.1% or 10 mV, whichever is greater
Pk-Pk: 1.0% or 50 mV, whichever is greater. Bandwidth limited to 20 MHz
Dynamicresponse: < ± 5% or 250 mV, with 50% step load
Recovery time: To within 1% in < 300 µsec
Reverse voltage protection: 100% of rated output current
Thermal protection:
(OTP)
All outputs disabled when internal temp exceeds safe operating range.
Remote sense: Up to 0.5 V total drop (not available on triple output module)
Single wire parallel: Current share to within 5% of total rated current
DCOK: ± 5% of nominal.
Minimum load: Not required
Housekeeping standby: 5 Vdc @ 1.0 A max. present whenever AC input is applied
Module inhibit: Logic-outputonwithloworopen.Differentlogicoptionsavailable
Output/Output isolation: >1Megohm,500V
Vout Full load
(A)
OVP trip max
(V)
OCP trip typ (I-
out%)
SCP trip max (I-
out%)
Overshoot (max
mV)
Peak Deviation
(max mV)
3V3 Module
0.9 40 TBD 130% 160% 150 ± 250
3.3 40 5.96 V 130% 160% 250 ± 250
3.6 40 6.32 V 130% 160% 250 ± 250
5 V Module
3.2 36 6.8 V 130% 160% 250 ± 250
5 36 8.8 V 130% 160% 250 ± 250
6 30 9.2 V 130% 160% 300 ± 300
12 V Module
6 25 12 V 130% 160% 300 ± 300
12 20 18 V 130% 160% 600 ± 600
15 16 20 V 130% 160% 750 ± 750
24 V Module
12 13 18 V 130% 160% 600 ± 600
24 10 31 V 130% 160% 1200 ± 1200
30 8 38 V 130% 160% 1500 ± 1500
48 V Module
28 7 TBD 130% 200% 1400 ± 1400
48 5 TBD 130% 160% 2400 ± 2400
60 4 TBD 130% 200% 3000 ± 3000
Case Line-Up
Case Max Output Dimensions Connections Max Current Amps
µMP4 - 4 Slot 400 W - 600 W 256.9±0.8 x 88.9±0.5 x 40.0±0.7
(10.11” x 3.5” x 1.57”) IEC/Terminal Block 9.91
µMP1 - 6 Slot 1000 W - 1200 W 256.9±0.8 x 127±0.5 x 40.0±0.5
(10.11” x 5” x 1.57”) IEC/Terminal Block 13.87
Output Module Line-Up
Output Range
(Vdc)
Max Current
(Amps)
Max Power
(Watts)
Module Codes
Standard Outputs
0.9 - 3.6 40 144 A,B,C,D-2,2.2,3,3.3
3.2 - 6.0 36 180 E, F, G, H - 5, 5, 2, 5.5, 6
6.0 - 15.0 25 240 I, J, K, L, M, N - 8, 10, 11, 12, 14, 15
12.0 - 30.0 13 240 O, P, Q, R, S - 18, 20, 24, 28, 30
28.0 - 54.0 7 240 T, U, V, W, X, Y - 28, 30, 33, 36, 42, 48, 54, 60
5.0 - 28.0
5.0 - 28.0
4
4
96
96
DualOutputModule.Eachoutputisratedto96W(192
Watts total). Wide range is adjustable.