KST-H035-000 1
STD13007F
NPN Silicon Power Transistor
Features
High speed switching
High Collector Voltage : VCBO = 700V
Suitable for Switching Regulator and Motor Control
Ordering Information
Type NO. Marking Package Code
STD13007F STD13007 TO-220F
Outline Dimensions unit : mm
S
Se
em
mi
ic
co
on
nd
du
uc
ct
to
or
r
PIN Connections
1. Base
2. Collector
3. Emitter
KST-H035-000 2
STD13007F
Absolute maximum ratings (Ta=25°C)
Characteristic Symbol Rating Unit
Collector-Base voltage VCBO 700 V
Collector-Emitter voltage VCEO 400 V
Emitter-base voltage VEBO 9 V
Collector current (DC) IC 8 A
Collector current (Pulse) ICM 16 A
Base current (DC) IB 4 A
Collector Power dissipation (Tc=25) PC 40 W
Junction temperature Tj 150
°C
Storage temperature Tstg -55~150
°C
Electrical Characteristics (Ta=25°C)
Characteristic Symbol Test Condition Min. Typ. Max. Unit
Collector-Emitter sustaining voltage BVCEO(sus) I
C=10mA, IB=0 400 - - V
Emitter cut-off current IEBO V
EB=9V, IC=0 - - 1 mA
IC=2A, VCE=5V 8 - 60
DC Current gain hFE*
IC=5A, VCE=5V 5 - 30
IC=2A, IB=0.4A - - 1
IC=5A, IB=1A - - 2
Collector-Emitter saturation voltage VCE(sat)*
IC=8A, IB=2A - - 3
V
IC=2A, IB=0.4A - - 1.2
Base-Emitter saturation voltage VBE(sat)*
IC=5A, IB=1A - - 1.6
V
Transition frequency fT V
CE=10V, IC=0.5A, f=1MHz - 14 - MHz
Output capacitance Cob V
CB=10V, IE=0, f=0.1MHz - 80 -
Turn on Time ton - - 1.6
Storage Time tstg - - 3
Fall Time tf
VCC=125V, IC=5A
IB1=-IB2=1A
- - 0.7
* Pulse test: PW300 , Duty cycle2%.
KST-H035-000 3
STD13007F
Electrical Characteristic Curves
Fig. 1 PC - TC Fig. 2 VBE(sat) , VCE(sat) - IC
Fig. 3 hFE-IC Fig. 4 tf , tstg - IC
Fig. 5 td , tr - IC Fig. 6 Cob - VCB
KST-H035-000 4
STD13007F
Fig. 7 Safe Operating Area
KST-H035-000 5
STD13007F
These AUK products are intended for usage in general electronic equipments(Office and
communication equipment, measuring equipment, domestic electrification, etc.).
Please make sure that you consult with us before you use these AUK products in equipm-
ents which require high quality and/or reliability, and in equipments which could have
major impact to the welfare of human life(atomic energy control, airplane, spaceship, traffic
signal, combustion central, all types of safety device, etc.).
AUK cannot accept liability to any damage which may occur in case these AUK products
were used in the mentioned equipments without prior consurtation with AUK.