3M™Scotch-Weld™
Epo xy Adhesives
D P190 T ranslucent and Gra y
- 2 -
Typical Cured
Properties
3M™ Scotch-Weld™ 3M™ Scotch-Weld™
Epo xy Adhesive Epoxy Adhesive
DP190 Translucent DP190 Gray
Color Translucent Gray
Hardness (ASTM D 2240)
Shore D 35 60
Worklife280 minutes 90 minutes
Tack-free Time3~ 4 hrs ~ 6 hrs
Time to Handling Strength46 hrs 8-12 hrs
Full Cure Time514 da ys 7 days
Elongation6120% 30%
Tensile Strength62750 psi 3500 psi
Physical
Scotch-Weld Scotch-Weld
Epo xy Adhesive Epo xy Adhesive
DP190 Translucent DP190 Gray
W eight Loss by Thermal Gravimetric 1% @ 390°F (199°C) 1% @ 477°F (247°C)
Analysis (TGA)75% @ 594°F (312°C) 5% @ 639°F (337°C)
Thermal Coefficient of Expansion (TCE)
by TMA8(∞x 10-6 units/unit/°C)
Below Tg 86 (41-68°F 62 (41-68°F
[5-20°C] range) [5-25°C] range)
Above Tg 166 (167-284°F 177 (167-284°F
[75-140°C] range) [65-140°C] range)
Glass Transition Temperature
(Tg) by DCS9
Onset 50°F (10°C) 45°F (7°C)
Mid-Point 80°F (27°C) 68°F (20°C)
Thermal Conductivity10
(@ 110°F on .250 in. samples)
BTU - ft./ft.2- hr. - °F) .079 .220
Cal./sec. - cm - °C) .39 x 10-3 90.9 x 10-2
Watt/m - °C .136 .381
Thermal Shock Resistance11
Potted Washer Ol yphant Test Pass 5 cycles Pass 5 cycles
(3M ITSD Test Method C-3174 without crac king without crac king
+100°C [air] to -50°C [liquid])
Thermal
Scotch-Weld Scotch-Weld
Epo xy Adhesive Epo xy Adhesive
DP190 Translucent DP190 Gray
Dielectric Constant @ 1 KHZ@ 73°F (23°C) 6.2 6.5
(ASTM D 150)
Dissipation Factor@ 1 KHZ@ 73°F (23°C) 0.16 0.09
(ASTM D 150)
Dielectric Strength 875 volts/mil 830 volts/mil
(ASTM D 149)
Sample Thickness Appr ox. 30 mil.
Volume Resistivity 7.5 x 1010 ohm-cm 5.0 x 1012 ohm-cm
(ASTM D 257)
Electrical
Note: The follo wing technical information and data should be considered r epresentative
or typical only and should not be used for specification purposes.
Footnotes:
3. Tack-free time determined per 3M
test method C-3173. Inv olves
dispensing 0.5 gram amount of
adhesive onto substrate and
testing periodically for no
adhesive transfer to metal spatula.
4. Handling strength determined per
3M test method C-3179. Time to
handling strength taken to be that
required to achieve a 50 psi OLS
strength using aluminum
substrates.
5. The cure time is defined as that
time required for the adhesive to
achieve a minimum of 80% of the
ultimate strength as measured by
aluminum-aluminum OLS .
6. Tensile and Elongation. Used
procedure in 3M test method
C-3094/ATSM D 882. Samples
were 2 in. dumbbells with .0125 in.
neck and .030 in. sample
thickness. Separ ation rate was 2
inches per minute. Samples cured
2 hrs RT plus 2 hrs/ 160°F (71°C).
7. W eight loss by TGA reported as
that temperature at which 5%
weight loss occurs by TGA in air
at 5°C rise per minute per ASTM
1131-86.
8. TCE determined using TMA
Analyzer using a heating rate of
50°F (10°C) per minute. Second
heat values given.
9. Glass Transition Temperature (Tg)
determined using DSC Analyzer
with a heating rate of 68°F (20°C)
per minute. Second heat values
given.
10. Thermal conductivity determined
using ASTM C177 and C-matic
Instrument using 2 in. diameter
samples.
11. Thermal shock resistance run per
3M test method C-3174. Involves
potting a metal washer into a 2 in.
x 0.5 in. thick section and cycling
this test specimen to colder and
colder temperatures.