Data Sheet. MD#950-12N1W to 22N1W Issue 2 Page 1 of 9 May, 2005
IXYS Date: 23.05.2005
Data Sheet Issue: 2
Dual Diode Water Cooled Modules MD# 950
Absolute Maximum Ratings
VRRM
VDRM
[V]
MDD MDA MDK
1200 950-12N1W 950-12N1W 950-12N1W
1400 950-14N1W 950-14N1W 950-14N1W
1600 950-16N1W 950-16N1W 950-16N1W
1800 950-18N1W 950-18N1W 950-18N1W
2000 950-20N1W 950-20N1W 950-20N1W
2200 950-22N1W 950-22N1W 950-22N1W
VOLTAGE RATINGS MAXIMUM
LIMITS UNITS
VRRM Repetitive peak reverse voltage 1) 1200-2200 V
VRSM Non-repetitive peak reverse voltage 1) 1300-2300 V
OTHER RATINGS MAXIMUM
LIMITS UNITS
IF(AV)M Maximum average forward current. Twater = 17°C, 4l/min 2), 3) 1129 A
IF(AV)M Maximum average forward current. Twater = 45°C, 4l/min 2), 3) 950 A
IF(AV)M Maximum average forward current. Twater = 85°C, 4l/min 2), 3) 668 A
IF(RMS) Nominal RMS forward current. Twater = 17°C, 4l/min 2), 3) 1773 A
IF(d.c.) D.C. forward current. Twater = 17°C, 4l/min 3) 1427 A
ITSM Peak non-repetitive surge tp = 10 ms, VRM = 60%VRRM 4) 21.8 kA
ITSM2 Peak non-repetitive surge tp = 10 ms, VRM ≤ 10 V 4) 24.0 kA
I2tI
2t capacity for fusing tp = 10 ms, VRM = 60%VRRM 4) 2.38×106A2s
I2tI2t capacity for fusing tp = 10 ms, VRM ≤ 10 V 4) 2.88×106A2s
Visol Isolation Voltage 5) 3500 V
Tvj op Operating temperature range -40 to +150 °C
Tstg Storage temperature range -40 to +125 °C
Notes:
1) De-rating factor of 0.13% per °C is applicable for TVj below 25°C.
2) Single phase; 50 Hz, 180° half-sinewave.
3) Current ratings do not include adjustments, which may be necessary due to heat being returned by cable connections.
4) Half-sinewave, 150°C TVj initial.
5) AC RMS voltage, 50 Hz, 1min test.