Description
Rapid interruption of excessive current
Compatible with reflow and wave solder
Rugged ceramic and glass construction
Excellent environmental integrity
One time positive disconnect
Compatible with lead free solders and higher
temperature profiles
Agency Information
UL Recognition Guide & File numbers:
JDYX2 &E19180
CSA Component Acceptance: 053787 C 000 &
Class Number: 1422 30
Environmental Data
Life Test: MIL-STD-202, Method 108A
Load Humidity Test: MIL-STD-202, Method 103B
Moisture Resistance Test: MIL-STD-202, Method 106E
Terminal Strength Test: Downward force is applied to
cause a 1mm deflection for 1 minute
Thermal Shock Test: MIL-STD-202, Method 107D
Solderability: ANSI/J-STD-002
Mechanical Shock Test: MIL-STD-202, Method 213B
High Frequency Vibration Test: MIL-STD-202,
Method 204D
Resistance to Solvents Test: MIL-STD-202, Method 215A
Ordering
Specify packaging and product code
(i.e., TR/0603FA250-R)
Soldering Method
Wave Solder: 260°C, 10 sec max.
Infrared Reflow: 260°C, 30 sec max.
1.25
(0.05)
0.50 0.90
(0.035)
(0.02)
Land Pattern
Dimensions mm(inches)
Drawing Not to Scale
ELECTRICAL CHARACTERISTICS
%of Amp Rating Opening Time
100% 4 Hours Minimum
200% 60 Seconds Maximum
SPECIFICATIONS
Current Voltage Interrupting DC Cold Typical Typical Alpha
Product Code Rating Rating Rating at Resistance** (ohms) Melting Voltage Code
DC Rated Voltage* Typical I2t*** Drop† Marking‡
0603FA250-R 250mA 32V 50A 3.100 0.0004 0.921 D
0603FA375-R 375mA 32V 50A 1.250 0.0009 0.605 E
0603FA500-R 500mA 32V 50A 1.025 0.00193 0.600 F
0603FA750-R 750mA 32V 50A 0.450 0.0090 0.440 G
0603FA1-R 1A 32V 50A 0.150 0.0025 0.211 H
0603FA1.25-R 1.25A 32V 35A 0.108 0.0130 0.151 J
0603FA1.5-R 1.5A 32V 35A 0.086 0.0319 0.138 K
0603FA2-R 2A 32V 35A 0.051 0.0491 0.116 N
0603FA2.5-R 2.5A 24V 35A 0.037 0.0625 0.113 O
0603FA3-R 3A 24V 35A 0.028 0.0699 0.110 P
0603FA3.5-R 3.5A 24V 35A 0.022 0.1200 0.103 R
0603FA4-R 4A 24V 35A 0.017 0.2430 0.097 S
0603FA5-R 5A 24V 35A 0.011 0.6950 0.090 T
* DC Interrupting Rating (Measured at designated voltage, time constant of less than 50 microseconds, battery source)
** DC Cold Resistance (Measured at 10% of rated current)
***Typical Melting I2t(Measured with a batterybank at rated DC voltage,10x-rated current, not to exceed IR, time constant of calibrated circuit less than 50
microseconds) (0603FA4A and 5A measured at interrupting rating)
Typical Voltage Drop (Measured at rated current after temperature stabilizes)
Alpha code to be marked on the top of fuse body for all ratings
Device designed to carry rated current for four hours minimum. An operating current of 80% or less of rated current is recommended, with
further derating required at elevated ambient temperatures.
ChipFuses
0603FA Series, Fast Acting
RoHS
2002/95/EC
PACKAGING CODE
Packaging Code Description
TR 5,000 pieces of fuses in paper tape and reeled on a 178mm (7 inch) reel per EIA Standard 481-1
TIME CURRENT CURVE
ChipFuses
0603FA Series, Fast Acting
Visit us on the web at:
www.cooperbussmann.com
OC-2547 Rev. XJ 3/07
© Cooper Electronic
Technologies 2007
Cooper Electronic Technologies
1225 Broken Sound Parkway NW
Suite F
Boca Raton, FL 33487-3533
Tel: 1-561-998-4100
Fax: 1-561-241-6640
Toll Free: 1-888-414-2645
Cooper Bussmann
P.O. Box 14460
St. Louis, MO 63178-4460
Tel: 1-636-394-2877
Fax: 1-800-544-2570
Cooper Electronic Technologies
Cooper (UK) Limited
Burton-on-the-Wolds
Leicestershire • LE12 5TH UK
Tel: +44 (0) 1509 882 737
Fax: +44 (0) 1509 882 786
Cooper Electronic Technologies
Avda. Santa Eulalia, 290
08223
Terrassa, (Barcelona), Spain
Tel: +34 937 362 812
+34 937 362 813
Fax: +34 937 362 719
Asia Pacific
Cooper Electronic Technologies
1Jalan Kilang Timor
#06-01 Pacific Tech Centre
Singapore 159303
Tel: +65 278 6151
Fax: +65 270 4160
North America Europe