SPECIFICATION
60WAC-DC High Reliability Slim Wall-mountedAdaptor SGA60E series
File Name:SGA60E-SPEC 2015-05-05
SAFETY STANDARDS
SAFETY &
EMC
(Note. 8)
TUV EN60950-1 approved
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
I/P-O/P:4242VDC
I/P-O/P:100M Ohms / 500VDC / 25 / 70% RH℃
Compliance to EN55022 class B, EN61000-3-2,3
EMC EMISSION
Compliance to EN61000-4,-2,3,4,5,6,8,11, light industry level, criteria A
EMC IMMUNITY
ORDER NO.
SAFETY MODEL NO.
DC VOLTAGE Note.2
RATED CURRENT
CURRENT RANGE
RATED POWER (max.)
RIPPLE & NOISE (max.) Note.3
OUTPUT
SETUP, RISE, HOLD UP TIME
VOLTAGE RANGE Note.7
FREQUENCY RANGE
EFFICIENCY (Typ.)
AC CURRENT
INPUT
ENVIRONMENT
INRUSH CURRENT (max.)
LEAKAGE CURRENT(max.)
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
LIFE
MTBF
DIMENSION
OTHERS
NOTE
PACKING
PROTECTION
5V 9V7.5V 12V 15V 18V 24V 48V
SGA60E05 SGA60E09SGA60E07 SGA60E12 SGA60E15 SGA60E18 SGA60E24 SGA60E48
SGA60E05-P1J
SGA60E09-P1JSGA60E07-P1J
SGA60E12-P1J
SGA60E15-P1J
SGA60E18-P1J
SGA60E24-P1J
SGA60E48-P1J
6A 5.5A6A 5A 4A 3.33A 2.5A 1.25A
0 ~ 6A 0 ~ 5.5A0 ~ 6A
0 ~ 5A
0 ~ 4A 0 ~ 3.33A 0 ~ 2.5A
80mVp-p 80mVp-p80mVp-p 80mVp-p 80mVp-p 80mVp-p 100mVp-p 120mVp-p
VOLTAGE TOLERANCE Note.4
LINE REGULATION Note.5
LOAD REGULATION Note.6
±5.0% ±5.0%±5.0% ±3.0% ±3.0% ±2.0% ±2.0% ±2.0%
±1.0% ±1.0%±1.0% ±1.0% ±1.0% ±1.0% ±1.0% ±1.0%
±5.0% ±5.0%±5.0% ±3.0% ±3.0% ±2.0% ±2.0% ±2.0%
90 ~ 264VAC
47 ~ 63Hz
1.5A / 115VAC 0.75A / 230VAC
40A / 115VAC 80A / 230VAC
0.25mA / 240VAC
3 years : 100% load 40 , 12hours / day℃
400Khrs min. MIL-HDBK-217F(25 )℃
-20 ~ +50 (Refer to "Derating Curve")℃
20% ~ 90% RH non-condensing
-20 ~ +85 , 10 ~ 95% RH℃
±℃℃0.03% / (0 ~ 40 )
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
93.5*35*51.5mm (L*W*H)
250g ; 60pcs / 17kg / CARTON
CONNECTOR
PLUG
CABLE
30W 49.5W45W 60W 60W 60W 60W 60W
0 ~ 1.25A
1.All parameters are specified at 115VAC input, rated load, 25 70% RH ambient. ℃
2.DC voltage: The output voltage set at point measure by plug terminal & 50% load.
3.Ripple & noise are measured at 20MHz by using a 12" twisted pair terminated with a 0.1uf & 47uf capacitor.
4.Tolerance: includes set up tolerance, line regulation, load regulation.
5.Line regulation is measured from low line to high line at rated load.
6.Load regulation is measured from 10% to 100% rated load.
7.Derating may be needed under low input voltages. Please check the static characteristics for more details.
8.The power supply is considered as an independent unit, but the final equipment still need to re-confirm that the whole system complies with the
EMC directives. For guidance on how to perform these EMC tests, please refer to EMI testing of component power supplies.
(as available on http://www.meanwell.com)
OVERLOAD
OVER VOLTAGE
110 ~ 200% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed
110 ~ 140% rated output voltage
Protection type : Clamp by zener diode, output short
500ms, 50ms, 12ms/230VAC 500ms, 50ms, 12ms/115VAC at full load
84% 87%86% 88% 87% 88% 88% 91%
See page 3 ; Other type available by customer requested
See page 3 ; Other type available by customer requested