The information provided in this documentation contains general descriptions and/or technical characteristics of the performance of the products contained herein.
This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications.
It is the duty of any such user or integrator to perform the appropriate and complete risk analysis, evaluation and testing of the products with respect to the relevant specific application or use thereof.
Neither Schneider Electric Industries SAS nor any of its affiliates or subsidiaries shall be responsible or liable for misuse of the information contained herein.
Mar 9, 2013
1
Product data sheet
Characteristics XPSAK351144
module XPSAK - Emergency stop - 120 V AC
Main
Range of product Preventa Safety automation
Product or component
type
Preventa safety module
Safety module name XPSAK
Safety module applica-
tion
For emergency stop, switch, sensing mat/edges or
safety light curtain monitoring
Function of module Monitoring of electro-sensitive protection equipment
(ESPE)
Monitoring of a movable guard associated with 2
switches and automatic start
Monitoring of a movable guard
Emergency stop monitoring 1-channel wiring
Emergency stop with 2 NC contacts monitoring 2-
channel wiring
Multiple emergency stop monitoring 2-channel
wiring
Proximity sensor monitoring
Sensing mat and edges monitoring
Safety level Can reach SILCL 3 conforming to EN/IEC 62061
Can reach PL e/category 4 conforming to EN/ISO
13849-1
Safety reliability data PFHd = 7.39E-9 1/h conforming to EN/IEC 62061
MTTFd = 154.5 years conforming to EN/ISO
13849-1
DC > 99 % conforming to EN/ISO 13849-1
Type of start Configurable
Connections - terminals Captive screw clamp terminals (2 x 0.5...2 x 1.5
mm²)flexible cable with cable end, with double bezel
Captive screw clamp terminals (2 x 0.25...2 x 1
mm²)flexible cable with cable end, with double bezel
Captive screw clamp terminals (2 x 0.14...2 x 0.75
mm²)solid cable with cable end, with double bezel
Captive screw clamp terminals (2 x 0.14...2 x 0.75
mm²)flexible cable with cable end, with double bezel
Captive screw clamp terminals (1 x 0.25...1 x 2.5
mm²)flexible cable with cable end, with double bezel
Captive screw clamp terminals (1 x 0.25...1 x 1.5
mm²)flexible cable with cable end, with double bezel
Captive screw clamp terminals (1 x 0.14...1 x 2.5
mm²)solid cable with cable end, with double bezel
Captive screw clamp terminals (1 x 0.14...1 x 2.5
mm²)flexible cable with cable end, with double bezel
Output type Relay instantaneous opening 3 NO, volt-free
Number of additional
circuits
1 NC + 4 solid state outputs
[Us] rated supply volt-
age
24 V DC (- 15...10 %)
120 V AC (- 15...10 %)
Complementary
Synchronisation time between inputs 2 or 4 s depending of wiring (automatic start)
Unlimited (manual start)
Supply frequency 50/60 Hz
Power consumption in VA <= 6 VA AC
Input protection type Internal, electronic
Control circuit voltage 24 V DC
Line resistance 28 Ohm
Breaking capacity C300: 1800 VA, AC-15 (inrush) for relay output
C300: 180 VA, AC-15 (holding) for relay output