02/46
Fuji Electric FA Components & Systems Co., Ltd./D & C Catalog
Information subject to change without notice
DUO series Contactors
SC-E series
SC-E series magnetic contactors/non-reversing
Features
Models SC-E02 to SC-E4 have 3-pole main circuits and
come in three sizes with widths of 43mm (up to 25A), 54mm
(up to 50A), and 67mm (up to 80A).
•Models SC-E1 to SC-E7 employ a box type terminal that
allows wires to be connected directly to the main circuit.
Equipped with a finger-protection terminal structure (IP20)
that prevents accidental finger touch to live parts.
Models SC-E5 to SC-E7 use a SUPER MAGNET (AC/DC-
input/DC-operate) to achieve high operating reliability.
Standards
IEC 60947-4-1, EN 60947-4-1, VDE 0660, JIS C 8201-4-1
UL 508, CSA C22.2
Type number nomenclature
SC-E02P/G
SC-E2S SC-E7
AF01-6 AF01-1
Accessories
A full range of accessories with the emphasis on utility.
Operating coil voltage
Blank: AC operated (E02 to E4)
AC/DC operated (E5 to E7)
G: DC operated (E02 to E4)
Wiring
Blank: Straight wiring connection
P: Ring terminal connection
Frame size
02 to E7
Ordering information
Specify the following:
1. Type number
2. Operating coil order voltage (
See page 02/51
)
Contactors: SC-E series
Thermal overload relays: TK-E series
Coil surge
suppression unit
Auxiliary
contact blocks
Top mounting
Front mounting
Side mounting Side mounting
Main circuit
surge suppression unit
Auxiliary contact block Main circuit surge
suppression unit
Base unit
for separate mounting
Reset release button
Contactor SC-E
Thermal overload relay TK-E
Auxiliary contact block
Trip indicator
Dial cover
Fuji Electric FA Components & Systems Co., Ltd./D & C Catalog
Information subject to change without notice
02/47
02
DUO series Contactors
SC-E series
Types and ratings
Operating coil Max. motor capacity (kW) Rated operating current (A)
3-phase AC-3 3-phase AC-3 Resistive load AC-1
AC operated 20 20 20 SC-E02
20 20 20 SC-E03
25 25 25 SC-E04
32 32 32 SC-E05
50 50 50 SC-E1
60 60 60 SC-E2
65 65 65 SC-E2S
100 100 100 SC-E3
105 105 105 SC-E4
AC/DC 150 150 150 2NO+2NC SC-E5
operated 150 150 150 2NO+2NC SC-E6
200 200 200 2NO+2NC SC-E7
DC operated 20 20 20 SC-E02/G
20 20 20 SC-E03/G
25 25 25 SC-E04/G
32 32 32 SC-E05/G
50 50 50 SC-E1/G
60 60 60 SC-E2/G
65 65 65 SC-E2S/G
100 100 100 SC-E3/G
105 105 105 SC-E4/G
Note :Ratings conform to IEC 60947-4-1
Aux. contact
arrangement
Contactor
type
Rated thermal current
(A)
380
440V
200
240V
200
240V
9
12
18
25
32
40
50
68
80
105
125
150
9
12
18
25
32
40
50
68
80
380
440V
9
12
18
25
32
40
50
65
80
105
125
150
9
12
18
25
32
40
50
65
80
600
690V
5
7
9
9
15
19
26
38
44
64
72
103
5
7
9
9
15
19
26
38
44
200
240V
2.2
3
4
5.5
7.5
11
15
18.5
22
30
37
45
2.2
3
4
5.5
7.5
11
15
18.5
22
380
440V
4
5.5
7.5
11
15
18.5
22
30
40
55
60
75
4
5.5
7.5
11
15
18.5
22
30
40
500
550V
4
5.5
7.5
11
15
18.5
25
37
37
55
60
75
4
5.5
7.5
11
15
18.5
25
37
37
600
690V
4
5.5
7.5
7.5
11
15
22
30
37
55
60
90
4
5.5
7.5
7.5
11
15
22
30
37
500
550V
7
9
13
17
24
29
38
60
60
85
90
120
7
9
13
17
24
29
38
60
60
Frame size Making current (A) Breaking current (A) Operating cycles Durability (operations)
220V 440V 220V 440V per hour Electrical Mechanical
SC-E02 108 108 90 90 1800 2 million 10 million
SC-E03 144 144 120 120 1800 1.5 million 10 million
SC-E04 216 216 180 180 1800 1.5 million 10 million
SC-E05 250 250 200 200 1200 1.5 million 10 million
SC-E1 384 384 320 320 1200 1.5 million 10 million
SC-E2 480 480 400 400 1200 1.5 million 10 million
SC-E2S 500 500 400 400 1200 1.5 million 10 million
SC-E3 816 780 680 650 1200 1.5 million 5 million
SC-E4 816 800 680 650 1200 1 million 5 million
SC-E5 1260 1260 1050 1050 1200 1 million 5 million
SC-E6 1500 1500 1250 1250 1200 1 million 5 million
SC-E7 1800 1800 1500 1500 1200 1 million 5 million
Performance data
02/48
Fuji Electric FA Components & Systems Co., Ltd./D & C Catalog
Information subject to change without notice
DUO series Contactors
SC-E series
SC-E series magnetic contactors/reversing
Features
Ideal for the forward-reverse operation of 3-phase motors or
plugging stops.
Mechanical interlock
Snap-on mounting to 35mm-wide top hat rail (DIN). (E02 to
E4)
Type number nomenclature
SC-E2RM/G
Operating coil voltage
Blank: AC operated (E02 to E4)
AC/DC operated (E5 to E7)
G: DC operated (E02 to E4)
Frame size
02 to E7
Types and ratings
Operating coil Max. motor capacity (kW) Rated operating current (A)
3-phase AC-3 3-phase AC-3 Resistive load AC-1
AC operated 20 20 20
SC-E02RM*
1
20 20 20
SC-E03RM*
1
25 25 25
SC-E04RM*
1
32 32 32
SC-E05RM*
1
50 50 50 SC-E1RM*
1
60 60 60 SC-E2RM*
1
65 65 65
SC-E2SRM*
1
100 100 100 SC-E3RM*
1
105 105 105 SC-E4RM*
1
AC/DC 150 150 150 (2NO+2NC) × 2SC-E5RM
operated 150 150 150 (2NO+2NC) × 2SC-E6RM
200 200 200 (2NO+2NC) × 2SC-E7RM
Aux. contact arrangement Contactor
type
Rated
thermal
current (A)
380
440V
200
240V
200
240V
9
12
18
25
32
40
50
68
80
105
125
150
380
440V
9
12
18
25
32
40
50
65
80
105
125
150
600
690V
5
7
9
9
15
19
26
38
44
64
72
103
200
240V
2.2
3
4
5.5
7.5
11
15
18.5
22
30
37
45
380
440V
4
5.5
7.5
11
15
18.5
22
30
40
55
60
75
500
550V
4
5.5
7.5
11
15
18.5
25
37
37
55
60
75
600
690V
4
5.5
7.5
7.5
11
15
22
30
37
55
60
90
500
550V
7
9
13
17
24
29
38
60
60
85
90
120
(1NO+1NC) × 2, 2NC × 2
(3NO+1NC) × 2, (2NO+2NC) × 2
(1NO+1NC) × 2, 2NC × 2
(3NO+1NC) × 2, (2NO+2NC) × 2
(1NO+1NC) × 2, 2NC × 2
(3NO+1NC) × 2, (2NO+2NC) × 2
(1NO+1NC) × 2, 2NC × 2
(3NO+1NC) × 2, (2NO+2NC) × 2
(1NO+1NC) × 2, 2NC × 2
(3NO+1NC) × 2, (2NO+2NC) × 2
(1NO+1NC) × 2, 2NC × 2
(3NO+1NC) × 2, (2NO+2NC) × 2
(1NO+1NC) × 2, 2NC × 2
(3NO+1NC) × 2, (2NO+2NC) × 2
(1NO+1NC) × 2, 2NC × 2
(3NO+1NC) × 2, (2NO+2NC) × 2
(1NO+1NC) × 2, 2NC × 2
(3NO+1NC) × 2, (2NO+2NC) × 2
Ratings conform to IEC 60947-4-1
*
1
The above types are shipped in a set containing two magnetic
contactors, one SZ-RM mechanical interlock unit, two front mounting
auxiliary contact blocks, and electrical interlock wiring. The power
connection kit for the reversing contactor is sold separately.
•To prevent short-circuit faults when using SC-E02R to SC-E04RM
types for high-speed switching, provide a time delay relay or other
electrical interlock to ensure that the switching time is 15ms min.
•For combined use with an MMS, instead of ordering a reversing type,
order and assemble the individual components (two magnetic contactors,
one SZ-RM mechanical interlock unit, two auxiliary contact blocks, and
the power connection kit (SZ-ERWM/A, SZ-ERWM/B).
*
1
Equipped with the SZ-A11/T, SZ-A02/T, SZ-A31/T, or SZ-A22/T front
mounting auxiliary contact block.
Notes: •For motor starter use, order the power connection kit and thermal
overload relay.
Type
SC-E02RM to SC-E05RM
SC-E1RM to SC-E2SRM
SC-E3RM to SC-E4RM
SC-E5RM to SC-E7RM
TOR
TK-E02
TK-E2
TK-E3
TK-E6H
SC-E3RM
No. KK03-040
Ordering information
Specify the following:
1. Type number
2. Operating coil order voltage (
See page 02/51
)
3. Auxiliary contact arrangement
Fuji Electric FA Components & Systems Co., Ltd./D & C Catalog
Information subject to change without notice
02/49
02
DUO series Contactors
SC-E series
Frame size Making current (A) Breaking current (A) Operating cycles Durability (operations)
220V 440V 220V 440V per hour Electrical Mechanical
SC-E02 108 108 90 90 1800 2 million 10 million
SC-E03 144 144 120 120 1800 1.5 million 10 million
SC-E04 216 216 180 180 1800 1.5 million 10 million
SC-E05 250 250 200 200 1200 1.5 million 10 million
SC-E1 384 384 320 320 1200 1.5 million 10 million
SC-E2 480 480 400 400 1200 1.5 million 10 million
SC-E2S 500 500 400 400 1200 1.5 million 10 million
SC-E3 816 780 680 650 1200 1.5 million 5 million
SC-E4 816 800 680 650 1200 1 million 5 million
SC-E5 1260 1260 1050 1050 1200 1 million 5 million
SC-E6 1500 1500 1250 1250 1200 1 million 5 million
SC-E7 1800 1800 1500 1500 1200 1 million 5 million
Performance data
Types and ratings
Ratings conform to IEC 60947-4-1
*
1
The above types are shipped in a set containing two magnetic
contactors, one SZ-RM mechanical interlock unit, two front mounting
auxiliary contact blocks, and electrical interlock wiring. The power
connection kit for the reversing contactor is sold separately.
•To prevent short-circuit faults when using SC-E02R/G to SC-E04RM/G
types for high-speed switching, provide a time delay relay or other
electrical interlock to ensure that the switching time is 15ms min.
•For combined use with an MMS, instead of ordering a reversing type,
order and assemble the individual components (two magnetic contactors,
one SZ-RM mechanical interlock unit, two auxiliary contact blocks, and
the power connection kit (SZ-ERWM/A, SZ-ERWM/B).
*
1
Equipped with the SZ-A11/T, SZ-A02/T, SZ-A31/T, or SZ-A22/T front
mounting auxiliary contact block.
Notes: •For motor starter use, order the power connection kit and thermal
overload relay.
Type
SC-E02RM/G to SC-E05RM/G
SC-E1RM/G to SC-E2SRM/G
SC-E3RM/G to SC-E4RM/G
SC-E5RM/G to SC-E7RM/G
TOR
TK-E02
TK-E2
TK-E3
TK-E6H
Operating coil Max. motor capacity (kW) Rated operating current (A)
3-phase AC-3 3-phase AC-3 Resistive load AC-1
DC operated 20 20 20
SC-E02RM/G*1
20 20 20
SC-E03RM/G*1
25 25 25
SC-E04RM/G*1
32 32 32
SC-E05RM/G*1
50 50 50
SC-E1RM/G*1
60 60 60
SC-E2RM/G*1
65 65 65
SC-E2SRM/G*1
100 100 100
SC-E3RM/G*1
105 105 105
SC-E4RM/G*1
Aux. contact arrangement Contactor
type
Rated
thermal
current (A)
380
440V
200
240V
200
240V
9
12
18
25
32
40
50
68
80
380
440V
9
12
18
25
32
40
50
65
80
600
690V
5
7
9
9
15
19
26
38
44
200
240V
2.2
3
4
5.5
7.5
11
15
18.5
22
380
440V
4
5.5
7.5
11
15
18.5
22
30
40
500
550V
4
5.5
7.5
11
15
18.5
25
37
37
600
690V
4
5.5
7.5
7.5
11
15
22
30
37
500
550V
7
9
13
17
24
29
38
60
60
(1NO+1NC) × 2, 2NC × 2
(3NO+1NC) × 2, (2NO+2NC) × 2
(1NO+1NC) × 2, 2NC × 2
(3NO+1NC) × 2, (2NO+2NC) × 2
(1NO+1NC) × 2, 2NC × 2
(3NO+1NC) × 2, (2NO+2NC) × 2
(1NO+1NC) × 2, 2NC × 2
(3NO+1NC) × 2, (2NO+2NC) × 2
(1NO+1NC) × 2, 2NC × 2
(3NO+1NC) × 2, (2NO+2NC) × 2
(1NO+1NC) × 2, 2NC × 2
(3NO+1NC) × 2, (2NO+2NC) × 2
(1NO+1NC) × 2, 2NC × 2
(3NO+1NC) × 2, (2NO+2NC) × 2
(1NO+1NC) × 2, 2NC × 2
(3NO+1NC) × 2, (2NO+2NC) × 2
(1NO+1NC) × 2, 2NC × 2
(3NO+1NC) × 2, (2NO+2NC) × 2
02/50
Fuji Electric FA Components & Systems Co., Ltd./D & C Catalog
Information subject to change without notice
DUO series Contactors
SC-E series
SC-E series contactors, ring terminal connection
types
Features
The new type allows wiring with ring crimp terminals in
addition to the conventional straight wiring connection.
Types SC-E02P to SC-E2SP also enable straight wiring
connection.
• A new slide-type terminal cover is easy to mount and
remove. Up to two ring crimp terminals can be connected
from the upper terminal part.
Three module designs with widths of 43mm (up to 25A),
54mm (up to 50A), and 67mm (up to 80A) provide an ideal
combination with manual motor starters for ring terminal
connection.
• UL, CSA (cUL) approval is pending.
SC-E2SP
KK04-066
Types and rings
• Magnetic contactors
Thermal overload relays
Operating coil Max. motor capacity (kW) Rated operational current (A) Rated thermal current
(A)
Aux. contact
arrangement
Type
3-phase AC-3 3-phase AC-3 3-phase AC-1
200V 380V 200V 380V 200V 380V
240V 440V 240V 440V 240V 440V
AC operated 2.2 4 9 9 20 20 20 SC-E02P
3 5.5 12 12 20 20 20 SC-E03P
4 7.5 18 18 25 25 25 SC-E04P
5.5 11 25 25 32 32 32 SC-E05P
7.5 15 32 32 50 50 50 SC-E1P
11 18.5 40 40 60 60 60 SC-E2P
15 22 50 50 65 65 65 SC-E2SP
18.5 30 68 65 100 100 100 SC-E3P
22 40 80 80 105 105 105 SC-E4P
DC operated 2.2 4 9 9 20 20 20 SC-E02P/G
3 5.5 12 12 20 20 20 SC-E03P/G
4 7.5 18 18 25 25 25 SC-E04P/G
5.5 11 25 25 32 32 32 SC-E05P/G
7.5 15 32 32 50 50 50 SC-E1P/G
11 18.5 40 40 60 60 60 SC-E2P/G
15 22 50 50 65 65 65 SC-E2SP/G
18.5 30 68 65 100 100 100 SC-E3P/G
22 40 80 80 105 105 105 SC-E4P/G
Applicable contactor
Non-reversing
Type Auxiliary contact
arrangement
Trip category (JIS)
Resistive load AC-1
No. of heater elements
SC-E02P, E02P/G
SC-E03P, E03P/G
SC-E04P, E04P/G
SC-E05P, E05P/G
TK-E02 1NO+1NC 10A 3
SC-E1P, E1P/G
SC-E2P, E2P/G
SC-E2SP, E2SP/G
TK-N2/T 1NO+1NC 10A 3
SC-E3P, E3P/G
SC-E4P, E4P/G
TK-N3/T 1NO+1NC 10A 3
• Coil characteristics:
See page 02/53
• dimensions:
See page 02/58
Fuji Electric FA Components & Systems Co., Ltd./D & C Catalog
Information subject to change without notice
02/51
02
DUO series Contactors
SC-E series
Order voltage Coil operating voltage and frequency
AC24V 24V AC 50Hz / 24–26V AC 60Hz
AC48V 48V AC 50Hz / 48–52V AC 60Hz
AC100V 100V AC 50Hz / 100–110V AC 60Hz
AC110V 100–110V AC 50Hz / 110–120V AC 60Hz
AC120V 110–120V AC 50Hz / 120–130V AC 60Hz
AC200V 200V AC 50Hz / 200–220V AC 60Hz
AC220V 200–220V AC 50Hz / 220–240V AC 60Hz
AC240V 220–240V AC 50Hz / 240–260V AC 60Hz
AC380V 346–380V AC 50Hz / 380–420V AC 60Hz
AC400V 380–400V AC 50Hz / 400–440V AC 60Hz
AC440V 415–440V AC 50Hz / 440–480V AC 60Hz
AC500V 480–500V AC 50Hz / 500–550V AC 60Hz
•AC/DC coil (SUPER MAGNET), SC-E5 to SC-E7
Order voltage Coil operating voltage and frequency
24V 24–25V AC 50/60Hz, 24V DC
48V 48–50V AC 50/60Hz, 48V DC
100V 100–127V AC 50/60Hz, 100–120V DC *1
200V 200–250V AC 50/60Hz, 200–240V DC *2
400V 380–450V AC 50/60Hz
500V 460–575V AC 50/60Hz
Notes: • Other voltages are available in 24 to 575V AC (24 to 240V DC) on request.
*1The coil voltage from DC power supply with single-phase full-wave
rectification will be 100–110V.
*2The coil voltage from DC power supply with single-phase full-wave
rectification will be 200–220V.
Operating coil
•AC coil, SC-E02 to SC-E4
Order voltage Coil operating voltage
DC12V 12V DC
DC24V 24V DC
DC48V 48V DC
DC60V 60V DC
DC100V 100V DC
DC110V 110V DC
DC120V 120V DC
DC200V 200V DC
DC210V 210V DC
DC220V 220V DC
DC coil, SC-E02/G to SC-E4/G
DC operated
Frame size Power consumption (W) Time constant Pick-up voltage (V) Drop-out voltage (V) Operating time (ms)
Inrush Sealed (ms) 200V DC 200V DC Coil ON Coil OFF
200V 200V Sealed Contact ON Contact OFF
E02/G to E05/G 7 7 50 92–130 30–60 45–49 10–26
E1/G to E2S/G 9 9 60 80–120 30–70 40–50 8–17
E3/G, E4/G 12 12 70 80–120 24–60 60–70 14–21
E5 90 2.8 1 140–160 40–100 35–41 26–32
E6, E7 225 3.2 1 140–160 40–100 28–34 27–33
Frame size Power consumption (VA) Power loss (W) Pick-up voltage (V) Drop-out voltage (V) Operating time (ms)
Inrush Sealed 200V 220V 200V 220V 200V 220V Coil ON Coil OFF
200V 50Hz 200V 50Hz 50Hz 60Hz 50Hz 60Hz 50Hz 60Hz Contact ON Contact OFF
E02 to E05 90 9 2.7 2.8 105–136 116–146 75–106 88–120 9–20 5–16
E1 to E2S 120 12.7 3.6 3.8 110–130 120–140 75–105 85–115 10–17 6–13
E3, E4 180 13.3 4.5 5 115–135 130–150 85–110 100–125 10–18 8–18
E5 80 4 3.2 3.6 140–150 140–150 60–100 60–100 39–45 27–33
E6, E7 190 4.9 3.4 3.7 140–150 140–150 60–100 60–100 31–37 30–36
Coil characteristics
•AC operated
Note: Other voltages are available in 24 to 600V AC on request.
Note: Other voltages are available in 12 to 250V DC on request.
02/52
Fuji Electric FA Components & Systems Co., Ltd./D & C Catalog
Information subject to change without notice
DUO series Contactors
SC-E series
Auxiliary contact ratings
Based on IEC 60974-4-1, EN 60947-4-1, JIS C 8201-4-1
Frame size Rated insulation Rated thermal Making and Rated operational current (A) Minimum operating
voltage (V) current (A) breaking capacity AC DC voltage and current
at AC (A) Voltage AC-15 Voltage DC-13
Ind. load Ind. load
E02 to E4 ––––
E02/G to E4/G
E5 to E7 690 10 120V 60 120V 6 24V 3 5V DC, 3mA
220V 30 220V 3 48V 1.5
440V 15 440V 1.5 110V 0.55
600V 12 600V 1.2 220V 0.27
Types and ratings for UL and CSA
Operating coil Max. motor capacity (Hp) Rated operating current (A) Type
3-phase motor 3-phase motor
AC operated 600 2 2 5 5 7.8 6.8 7.6 6.1 20 SC-E02
33 7.5 7.5 11 9.6 11 9 20 SC-E03
5510 10 17.5 15.2 14 11 25 SC-E04
5 7.5 15 15 17.5 22 21 17 32 SC-E05
7.5 10 25 25 25.3 28 34 27 50 SC-E1
10 15 30 30 32.2 42 40 32 60 SC-E2
15 20 30 30 48.3 54 40 32 65 SC-E2S
20 25 50 50 62.1 68 65 52 100 SC-E3
25 30 50 50 78.2 80 65 52 105 SC-E4
AC/DC 600 30 30 60 75 92 80 77 77 150 SC-E5
operated 40 40 75 100 119.6 104 96 99 150 SC-E6
50 50 100 125 149.5 130 124 125 200 SC-E7
DC operated 600 2 2 5 5 7.8 6.8 7.6 6.1 20 SC-E02/G
33 7.5 7.5 11 9.6 11 9 20 SC-E03/G
5510 10 17.5 15.2 14 11 25 SC-E04/G
5 7.5 15 15 17.5 22 21 17 32 SC-E05/G
7.5 10 25 25 25.3 28 34 27 50 SC-E1/G
10 15 30 30 32.2 42 40 32 60 SC-E2/G
15 20 30 30 48.3 54 40 32 65 SC-E2S/G
20 25 50 50 62.1 68 65 52 100 SC-E3/G
25 30 50 50 78.2 80 65 52 105 SC-E4/G
Rated
thermal
current (A)
Rated insulation
voltage (V)
220
240V
200V 400
480V
550
600V
220
240V
200V 400
480V
550
600V
Frame size Rated insulation Rated thermal Making and breaking current (A)
voltage (V) current (A) AC (rating code A600) DC (rating code Q300)
Voltage Making Breaking Voltage Making Breaking
E02 to E4 ––––
E02/G to E4/G
E5 to E7 600 10 120V 60 6 125V 0.55 0.55
240V 30 3 250V 0.27 0.27
480V 15 1.5
600V 12 1.2
Auxiliary contact ratings for UL and CSA
Fuji Electric FA Components & Systems Co., Ltd./D & C Catalog
Information subject to change without notice
02/53
02
DUO series Contactors
SC-E series
Electrical durability
• AC-3 duty / SC-E02 to SC-E05
1 2 3 20 30 50 100 200 300 500 1000
105
380 - 440V
200 - 240V
10
100
20
30
50
1000
200
300
500
10000
2000
3000
5000
Breaking current (A)
SC-E02
SC-E05
SC-E04
SC-E03
9A
12A
18A
25A
10
100
20
30
50
1000
200
300
500
10000
2000
3000
5000
200 - 240V 380 - 440V
4kW
5.5kW
7.5kW
11kW
2.2kW
3kW
4kW
5.5kW
3-phase motor capacity (kW)
and full-load current (A)
Make/break operations ( 10
3
)
• AC-3 duty / SC-E1 to SC-E7
10 20 30 200 300 500 1000 2000 3000 5000 10000
10050
200 - 240V
380 - 440V
10
100
20
30
50
1000
200
300
500
10000
2000
3000
5000
SC-E1
SC-E2
SC-E2S
32A
40A
50A
65A
80A
105A
150A
10
100
20
30
50
1000
200
300
500
10000
2000
3000
5000
200 - 240V 380 - 440V
15kW
11kW
15kW
18.5kW
7.5kW
18.5kW
30kW
40kW
55kW
75kW
60kW
22kW
125A
22kW
30kW
37kW
45kW
SC-E7
SC-E3
SC-E4
SC-E5
SC-E6
Breaking current (A)
3-phase motor capacity (kW)
and full-load current (A)
Make/break operations ( 10
3
)
• AC-1 duty / SC-E02 to SC-E7
32A
20A
60A
100A
150A
50A
25A
65A
105A
200A
100
1000
200
300
500
10000
2000
3000
5000
100
1000
200
300
500
2000
3000
5000
200 - 240V
1 2 3
SC-E02
SC-E03
SC-E05
SC-E04
SC-E1
SC-E2
SC-E2S
380 - 440V
SC-E3
SC-E4
SC-E5
SC-E6
SC-E7
20 30 50 100 200 300 500 1000
105
10000
Breaking current (A)
Make/break operations ( 10
3
)
02/54
Fuji Electric FA Components & Systems Co., Ltd./D & C Catalog
Information subject to change without notice
DUO series Contactors
SC-E series
Optional accessories
Optional accessories
• Auxiliary contact blocks with terminal covers
The front mounting auxiliary contact block allows two or four auxiliary contacts to be
added without increasing the mounting area of the magnetic contactors. The side
mounting auxiliary contact block allows two auxiliary contacts to be added to the
magnetic contactors without increasing the depth.
Applicable contactor Mounting No. of contacts Contact arrangement Type
SC-E02 to E4 Front mounting 4 4NO SZ-A40/T
3NO+1NC SZ-A31/T
2NO+2NC SZ-A22/T
22NO SZ-A20/T
1NO+1NC SZ-A11/T
2NC SZ-A02/T
SC-E02 to E4 Side mounting 2 1NO+1NC SZ-AS1/T
SC-E5, E6, E7 2 1NO+1NC SZ-AS2/T
Main circuit surge suppression units
When contactor is energized or de-energized, a surge voltage is generated from
motor circuit. This unit suppresses this surge voltage and protects electronic
equipment from malfunction or damage.
Applicable Mounting Rated voltage CR constant Applicable Type
contactor and frequency 3-phase motor
SC-E02 to E05 Front mounting 250V AC C=0.22µF200–240V AC SZ-ZM1E
Side mounting 50/60Hz R=100 0.1–5.5kW SZ-ZM2E
SC-E1 to E4 Front mounting 250V AC C=0.33µF200–240V AC SZ-ZM3E
Side mounting 50/60Hz R=47 0.1–22kW SZ-ZM4E
Coil surge suppression units
This unit suppresses surge voltage due to contactor ON-OFF operations, and can be
easily connected to contactor coil terminals.
Applicable contactor Operating Device Operation Type
AC operated DC operated coil voltage indicator
SC-E02 to E05 SC-E02/G to E05/G 24–48V AC/DC Varistor SZ-Z1
100–250V AC/DC SZ-Z2
380–440V AC SZ-Z3
SC-E02 to E05 SC-E02/G to E05/G 24–48V AC/DC Red LED SZ-Z6
100–250V AC/DC Red LED SZ-Z7
SC-E1 to E4 SC-E1/G to E4/G 24–48V AC/DC SZ-Z31
100–250V AC/DC SZ-Z32
380–440V AC SZ-Z33
SC-E02 to E05 SC-E02/G to E05/G 24–48V AC/DC CR SZ-Z4
100–250V AC/DC SZ-Z5
SC-E02 to E05 SC-E02/G to E05/G 24–48V AC/DC Red LED SZ-Z8
100–250V AC/DC Red LED SZ-Z9
SC-E1 to E4 24–48V AC SZ-Z34
100–250V AC SZ-Z35
SC-E1/G to E4/G 24–48V DC SZ-Z36
100–250V DC SZ-Z37
Main circuit surge suppression units
SZ-A11/T
AF88-080
SZ-A22/T
KK02-081
Front mounting
Side mounting
SZ-AS1/T
SZ-AS2/T
Side mounting
SZ-ZM4E
Front mounting
SZ-ZM1E
Top mounting
CR
SZ-Z4
Coil surge suppression unit
AF88-766
KK01-090
KK02-079
KK02-077
Fuji Electric FA Components & Systems Co., Ltd./D & C Catalog
Information subject to change without notice
02/55
02
DUO series Contactors
SC-E series
Optional accessories
Auxiliary contact blocks
Contact ratings
Based on IEC and JIS
Rated Making and Rated operational current (A)
thermal breaking AC DC
current (A) capacity
Voltage AC-15 Voltage DC-13
at AC (A)
Ind. load Ind. load
10 120V 60 120V 6 24V 3 5V DC
220V 30 220V 3 48V 1.5 3mA
440V 15 440V 1.5 110V 0.55
600V 12 600V 1.2 220V 0.27
Based on UL and CSA
Rated Making and breaking current (A)
thermal AC (rating code A600) DC (rating code Q300)
current (A) Volts Making
Breaking
Volts Making
Breaking
10 120V 60 6 125V 0.55 0.55
240V 30 3 250V 0.27 0.27
480V 15 1.5
600V 12 1.2
Minimum
operating
voltage and
current
Mechanical interlock unit
The mechanical interlock unit provides a mechanical interlock
with assembly parts to convert a magnetic contactor into a
reversing magnetic contactor.
Applicable contactor Type
SC-E02 to E4 SZ-RM
SC-E02/G to E4/G
•Power connection kit for reversing
This kit includes an electrical interlock circuit to convert a
magnetic contactor into a reversing magnetic contactor. SZ-ERW1/A
+
SZ-ERW1/B
SZ-ERW3/A
+
SZ-ERW3/B
KK03-047 KK03-048
SZ-RM
AF99-47
Applicable contactor
SC-E02 to E05
SC-E02/G to E05/G
SC-E1 to E2S
SC-E1/G to E2S/G
SC-E3, E4
SC-E3/G, E4/G
SC-E5
SC-E6
SC-E7
Wiring side
Line side
Load side
Load side (For starter)
Line side
Load side
Load side (For starter)
Line side
Load side
Load side (For starter)
Line side
Load side
Line side
Load side
Line side
Load side
Type
SZ-ERW1/A
SZ-ERW1/B
SZ-ERW1/D
SZ-ERW2/A
SZ-ERW2/B
SZ-ERW2/D
SZ-ERW3/A
SZ-ERW3/B
SZ-ERW3/D
SZ-ERW4/A
SZ-ERW4/B
SZ-ERW5/A
SZ-ERW5/B
SZ-ERW6/A
SZ-ERW6/B
•W
hen the SC-E02 to SC-E4 magnetic contactors and mechanical interlock
unit are ordered separately, there is no electrical interlock circuit included.
In this case, also order the SZ-AM/T auxiliary contact block to provide an
electrical interlock.
The SC-E5 to SC-E7 cannot be assembled as reversing motor starters.
Use a separate mounting thermal overload relay (TK-E6H).
Note :
02/56
Fuji Electric FA Components & Systems Co., Ltd./D & C Catalog
Information subject to change without notice
DUO series Contactors
SC-E series
Dimensions
Dimensions, mm
Non-reversing/AC operated
SC-E02, E03, E04, E05
Panel drilling
34
13
60
(48 to)52
35
18.5(to 20.5)
14.5
43
81
49 20
(28)
8.5
61
81
91 (68)
10.5
*
1
Mounting hole
2-M4
(Rail height 15)
*
2
*
1
*
2
Main
terminal M4 Coil terminal
M3.5
2
1
Mass: 0.33kg
SC-E1, E2, E2S
106 (Rail height 15)
18.5
90
(28)
65.5
96
80
45(38 to 46)
45
75
16.5
57
54
10.5
9.5
5
(79)
2
2
1
Panel drilling
Mounting hole
2-M4
Main
terminal
Coil terminal
M3.5
*1
*1
*2
*2
Mass : 0.58kg
SC-E3, E4
90 13
72.5
20.5
77
19.5
112
(28)
10.5 67
(55 to)60
(54 to)60
121 (Rail height 15)
111
2.5
(91)
2
1
Panel drilling
Mounting hole
2-M4
Main
terminal
Coil terminal
M3.5
*
2
*
2
*
1
*
1
Mass: 1.05kg
SC-E5
75
77
32.7 70
132
88
32
155
13.5
129
(112)
4Auxiliary
terminal
M3.5
Panel drilling
Mounting hole
2-M4
Main
terminal Coil terminal
M3.5
*
1
Mass: 2.04kg
*1 Side mounting aux. contact block
*2 Front mounting aux. contact block
Wiring diagrams
*
1
*
1
6/T3 4/T2 2/T1
53 61 1/L1 3/L2 5/L3 83 71
A1 A2
72846254
*
1
In case of aux. contact 2NO+2NC
*
1
In case of aux. contact 2NO+2NC
*
1
*
1
6/T3 4/T2 2/T1
53 61 1/L1 3/L2 5/L3 83 71
A1 A2
72846254
*
1
In case of aux. contact 2NO+2NC
*
1
*
1
6/T3 4/T2 2/T1
53 61 1/L1 3/L2 5/L3 83 71
A1 A2
72846254
*
1
In case of aux. contact 4NO+4NC
6/T3 4/T2 2/T1
*
1
53 61 13 21 1/L1 3/L2 5/L3 43 31 83 71 A1 A2
7284324422146254
*
1
Use the two mounting holes on a diagonal line
or to mount contactor
: 35 60 : 34 (48 to) 52
Use the two mounting holes on a diagonal line
or to mount contactor
: 45 75 : 45 (38 to 46) 80
Use the two mounting holes on a diagonal line
or to mount contactor
: (55 to) 60 90 : (54 to) 60 90
Fuji Electric FA Components & Systems Co., Ltd./D & C Catalog
Information subject to change without notice
02/57
02
DUO series Contactors
SC-E series
Dimensions
Dimensions, mm
Non-reversing/AC operated
SC-E6
(80 to)90
110
32
169
143 13.5
100
38.8
138
77 (123)
4Auxiliary
terminal
M3.5
Panel drilling
Mounting hole
2-M5
Main
terminal Coil terminal
M3.5
*1
Mass: 2.55kg
SC-E7
35
140
38.8
76.8
146 14.5
175
(139)
115 (80 to)90
110
Auxiliary
terminal
M3.5
Panel drilling
Mounting hole
2-M5
Main
terminal
Coil terminal
M3.5
*1
Mass: 2.86kg
Non-reversing/DC operated
SC-E02/G, E03/G, E04/G, E05/G
Panel drilling
Mounting hole
2-M4
Main
terminal
M4
Coil terminal
M3.5
*
1
*
1
*
2
*
2
(28)
8.5 88108
118 (Rail height 15)
13
43
81
49 20
(68)
10.5
34
60
(48 to)52
35
18.5(to 20.5)
14.5
2
1
Mass: 0.59kg
SC-E1/G, E2/G, E2S/G
130 (Rail height 15)
18.5
90
(28)
16.5
57
10.5
121.5
91
254
(79)
5
9.5
75
45
45(38 to 46)
80
1
2
Panel drilling
Mounting hole
2-M4
Main
terminal
Coil terminal
M3.5
*
2
*
2
*
1
*
1
Mass: 0.79kg
*1 Side mounting aux. contact block
*2 Front mounting aux. contact block
Wiring diagrams
*
1
In case of aux. contact 4NO+4NC
6/T3 4/T2 2/T1
*
1
53 61 13 21 1/L1 3/L2 5/L3 43 31 83 71 A1 A2
7284324422146254
*
1
*
1
In case of aux. contact 4NO+4NC
6/T3 4/T2 2/T1
*
1
53 61 13 21 1/L1 3/L2 5/L3 43 31 83 71 A1 A2
7284324422146254
*
1
*
1
*
1
6/T3 4/T2 2/T1
53 61 1/L1 3/L2 5/L3 83 71
A1 A2
72846254
*
1
In case of aux. contact 2NO+2NC
*
1
In case of aux. contact 2NO+2NC
*
1
*
1
6/T3 4/T2 2/T1
53 61 1/L1 3/L2 5/L3 83 71
A1 A2
72846254
Use the two mounting holes on a diagonal line
or to mount contactor
: 35 60 : 34 (48 to) 52
Use the two mounting holes on a diagonal line
or to mount contactor
: 45 75 : 45 (38 to 46) 80
02/58
Fuji Electric FA Components & Systems Co., Ltd./D & C Catalog
Information subject to change without notice
DUO series Contactors
SC-E series
Dimensions
Dimensions, mm
• Non-reversing/DC operated
SC-E3/G, E4/G
20.5
77
19.5
112
(28)
91.5
130
140 (Rail height 15)
10.5 2.5 67
(91) (54 to)60
(55 to)60
13
90
1
2
Panel drilling
Mounting hole
2-M4
Coil terminal
M3.5
*2
*2
*1
*1
Mass: 1.4kg
Main
terminal
• Reversing/AC operated
SC-E02RM, E03RM, E04RM, E05RM
Panel drilling
21 3535
60 14.5
Mounting hole
4-M4
8.5
61
92
109
119 (Rail height 15)
Coil terminal
M3.5
56
99
Main
terminal
Auxiliary
terminal
M3.5
28
7.7
10
10.5
13
49 20
81
70.5
Mass : 0.8kg (AUX.4P)
0.77kg(AUX.2P)
SC-E1RM, E2RM, E2SRM
Mass : 1.3kg (AUX.4P)
1.27kg(AUX.2P)
Panel drilling
10.5 2
107
124
134 (Rail height 15)
67
121
22
45 45
75
67
Mounting hole
4-M4
Main
terminal
Coil terminal
M3.5
Auxiliary
terminal
M3.5
9.5
65.5
57
18.5
90
16.5
28
10
7.7
86
SC-E3RM, E4RM
Mass : 2.24kg(AUX.4P)
2.21kg(AUX.2P)
Panel drilling
10.5 2.5
72.5
121
139
149 (Rail height 15)
80
147
Main
terminal
Coil terminal
M3.5
Auxiliary
terminal
M3.5
(54 to)60 (54 to)60
90 13
80
Mounting hole
4-M4
28
77
19.5
112
20.5
7.7
10
108
23
*1 Side mounting aux. contact block
*2 Front mounting aux. contact block
Use the two mounting holes on a diagonal line
or to mount contactor
: (55 to) 60 90 : (54 to) 60 90
*
1
In case of aux. contact 2NO+2NC
*
1
*
1
6/T3 4/T2 2/T1
53 61 1/L1 3/L2 5/L3 83 71
A1 A2
72846254
Wiring diagrams
SC-E02RM to E4RM
54
53
A2
A1
6/T3 4/T2 2/T1
53 1/L1 3/L2 5/L3 61
A1 A2
6254
1/L1 3/L2 5/L3 61
62 6/T3 4/T2 2/T1
2/T1 4/T2 6/T3 62
61 5/L3 3/L2 1/L1
52 62
A2A1
61 5/L3 3/L2 1/L1 51
2/T1 4/T2 6/T3
A1 A2
51
52
2/T1 4/T2 6/T3 62
61 5/L3 3/L2 1/L1
54 62
A2A1
61 5/L3 3/L2 1/L1 53
2/T1 4/T2 6/T3
A1 A2
53
54
73
74
83
84
73
74 84
83
83
8472
71
84
83
72
71
54
53
A2A1
6/T3 4/T2 2/T1
53 1/L1 3/L2 5/L3 61
A1 A2
6254
1/L1 3/L2 5/L3 61
62 6/T3 4/T2 2/T1
(1NO+1NC) × 2
(2NO+2NC) × 2
(3NO+NC) × 2
2NC × 2
Fuji Electric FA Components & Systems Co., Ltd./D & C Catalog
Information subject to change without notice
02/59
02
DUO series Contactors
SC-E series
Dimensions
Dimensions, mm
•Reversing/AC operated
SC-E5RM
1.6
82
4
137
Mounting hole
3-M5 Auxiliary terminal M3.5
150 7.5
165
111
200
230
Coil terminal
M3.5
Main
terminal
32
129 10.5
155
Mass : 4.64kg
SC-E6RM
1.6 4
83
145
175 7.5
190
123
220
250
Mounting hole 3-M5 Auxiliary terminal M3.5
Coil terminal
M3.5
Main
terminal
32
169.5
143 16
Mass : 5.8kg
SC-E7RM
24
84
147
200 7.5
215
138
260
290
Mounting hole
3-M6
Auxiliary terminal M3.5
Main terminal
Coil terminalM3.5
35
146 27
175
Mass : 6.8kg
Wiring diagrams
SC-E5RM to E7RM
54
53
A2
A1
6/T3 4/T2 2/T1
53 1/L1 3/L2 5/L3 61
A1 A2
6254
1/L1 3/L2 5/L3 61
62 6/T3 4/T2 2/T1
2/T1 4/T2 6/T3 62
61 5/L3 3/L2 1/L1
52 62
A2A1
61 5/L3 3/L2 1/L1 51
2/T1 4/T2 6/T3
A1 A2
51
52
2/T1 4/T2 6/T3 62
61 5/L3 3/L2 1/L1
54 62
A2A1
61 5/L3 3/L2 1/L1 53
2/T1 4/T2 6/T3
A1 A2
53
54
73
74
83
84
73
74 84
83
83
8472
71
84
83
72
71
54
53
A2A1
6/T3 4/T2 2/T1
53 1/L1 3/L2 5/L3 61
A1 A2
6254
1/L1 3/L2 5/L3 61
62 6/T3 4/T2 2/T1
(1NO+1NC) × 2
(2NO+2NC) × 2
(3NO+NC) × 2
2NC × 2
02/60
Fuji Electric FA Components & Systems Co., Ltd./D & C Catalog
Information subject to change without notice
DUO series Contactors
SC-E series
Dimensions
Dimensions, mm
•Reversing/DC operated
SC-02RM/G, 03RM/G, 04RM/G, 05RM/G
Panel drilling
Mounting hole
4-M4
60 14.5
352135
Auxiliary
terminal
M3.5
Main
terminal
Coil terminal
M3.5
56
99
2049
81
13
10.5
10
7.7
28
70.5
8.5
88
119
136
146 (Rail height 15)
Mass : 1.32kg (AUX.4P)
1.29kg(AUX.2P)
SC-E1RM/G, E2RM/G, E2SRM/G
Panel drilling
2
67
121
90
2245 45
75
67
Mounting hole
4-M4
Main
terminal
Coil terminal
M3.5
Auxiliary
terminal
M3.5
91
10.5
132.5
149.5
9.5
86
57
18.5
16.5
7.7
10
28
158 (Rail height 15)
Mass : 1.72kg (AUX.4P)
1.69kg(AUX.2P)
SC-E3RM/G, E4RM/G
Panel drilling
2.5
80
147
112
Main
terminal
Coil terminal
M3.5
Auxiliary
terminal
M3.5
23
(54 )60 (54 )60
90 13
80
Mounting hole
4-M4
10.5
91.5
140
158
168 (Rail height 15)
77 19.5
108
28
7.7
20.5
10
Mass : 2.84kg (AUX.4P)
2.81kg(AUX.2P)
Wiring diagrams
SC-E5RM to E7RM
*1 In case of aux. contact (3NO+3NC) × 2
14 22 2/T1 4/T2 6/T3 44 32
3143 5/L3 3/L2 1/L1
21
13
A2
A1
14 22 44 32
A2
A1
3143 5/L3 3/L2 1/L12113
*1
84 72
7183
*1
53
54
61
62 2/T1 4/T2 6/T3
Fuji Electric FA Components & Systems Co., Ltd./D & C Catalog
Information subject to change without notice
02/61
02
DUO series Contactors
SC-E series
Dimensions
Dimensions, mm
•Auxiliary contact blocks/Front mounting
SZ-A40/T, A31/T, A22/T, A20/T, A11/T, A02/T for SC-E02 to E4
525 43
10
11
7.7
10
24
7.7
49
M3.5 M3.5
28
49
28
Approx
3
AC
Approx
3
B
Contactor with aux. contact block
A
B
SZ-A40/T, A31/T, A22/T Mass: 36g
SZ-A20/T, A11/T, A02/T Mass: 20g
•Auxiliary contact blocks/Side mounting
SZ-AS1/T, for SC-E02 to E4
28
43
59.5
7.7 12 7.5
45
M3.5
A
B
C
12 12D
Contactor with aux. contact block
Mass: 28g
SZ-AS2/T, for SC-E5 to E7
C12 12
A
B
64.5
12
7.7
M3.5
28
47
7
47.5
Contactor with aux. contact block
D
Mass: 33g
Wiring diagrams
53 63 73 83
54 64 74 84
53 61 73 83
54 62 74 84
53 61 71 83
54 62 72 84
4NO
3NO+1NC
2NO+2NC
53 63
54 64
53 61
54 62
51 61
52 62
2NO
1NO+1NC
2NC
1NO+1NC
1NO+1NC
Type
SC-E02, E03, E04, E05
SC-E1, E2, E2S
SC-E3, E4
A
43
54
67
B
81
90
112
C
109
124
139
Type
SC-E02, E03, E04, E05
SC-E1, E2, E2S
SC-E3, E4
A
68
79
91
B
81
90
112
C
81
96
111
D
43
54
67
Type
SC-E5
SC-E6
SC-E7
A
112
123
139
B
155
169
175
C
132
138
140
D
88
100
115
53 61
54 62
71 83
72 84
Mounted on right side
Mounted on left side
53 61
54 62
71 83
72 84
Mounted on right side
Mounted on left side
02/62
Fuji Electric FA Components & Systems Co., Ltd./D & C Catalog
Information subject to change without notice
DUO series Contactors
SC-E series
Dimensions
Dimensions, mm
• Main circuit surge suppression units
Type
SC-E02+SZ-ZM1E
SC-E03+SZ-ZM1E
SC-E04+SZ-ZM1E
SC-E05+SZ-ZM1E
SC-E1+SZ-ZM3E
SC-E2+SZ-ZM3E
SC-E2S+SZ-ZM3E
SC-E3+SZ-ZM3E
SC-E4+SZ-ZM3E
A
43
54
67
B
81
90
112
C
121
136
151
34 4.5
43
45
27
34 4.5
43
45
27
A
B
CMin.5
45
34
SZ-ZM3E
SZ-ZM1E
Contactor with surge suppression unit
Mass: 60g
6022
37
39
6022
37
39
CA
B
22
39
D
Type
SC-E02+SZ-ZM2E
SC-E03+SZ-ZM2E
SC-E04+SZ-ZM2E
SC-E05+SZ-ZM2E
SC-E1+SZ-ZM2E
SC-E2+SZ-ZM4E
SC-E2S+SZ-ZM4E
SC-E3+SZ-ZM4E
SC-E4+SZ-ZM4E
A
65
76
89
B
81
90
112
C
81
96
111
D
43.5
49
55.5
SZ-ZM4E
SZ-ZM2E
Contactor with surge suppression unit
Mass: 60g
Connection diagram
5
3
1
6
4
2
Contactor
Thermal overload relay
M
Motor
W
V
U
Main circuit surge suppression unit
Coil surge suppression units
SZ-Z1, Z2, Z3, Z4, Z5
27 10
14
15
26
Mass: 14g
SC-E02 to E05 + SZ-Z1 to Z3
(Built-in varistor)
SC-E02 to E05 + SZ-Z4, Z5
(Built-in CR)
C
R
SZ-Z6, Z7, Z8, Z9
27 10
14
LED LED 35
15
Mass: 16g
SC-E02 to E05 + SZ-Z6, Z7
(Built-in varistor with operating indicator)
R
SC-E02 to E05 + SZ-Z8, Z9
(Built-in CR with operating indicator)
R2
R1
C
SZ-Z31, Z32, Z33, Z34, Z35, Z36, Z37
30
37
12.526
13.5
Mass: 15g
SC-E1 to E4 + SZ-Z31 to Z33
(Built-in varistor)
SC-E1 to E4 + SZ-Z34, Z35
(Built-in CR)
SC-E1/G to E4/G + SZ-Z36, Z37
(Built-in CR)
C
R
Fuji Electric FA Components & Systems Co., Ltd./D & C Catalog
Information subject to change without notice
02/63
02
DUO series Contactors
SC-E series
Dimensions
Dimensions, mm
Mechanical interlock unit
SZ-RM
Interlock block Connector block
Mass : 18g Mass : 4.2g
25
17
13
47
36
41
31.5 13
•Power connection kit for reversing
For crossover wiring/SZ-ERW1/A
Mass : 19g
WiringWiring side
Line side
Used with
SC-E02RM, E03RM, E04RM, E05RM
SC-E02RM/G, E03RM/G, E04RM/G,
E05RM/G
When using this connection kit, use a separate mounting thermal
overload relay to connect to the magnetic contactor. If the attachment
tab is used for assembly to the magnetic contactor, interference by
components will make assembly impossible. To assemble using the
attachment tab, use the SZ-ERW1/D type power connection kit.
Note :
16 9
30
56
82
86
ø2
17.5
18.5
For phase replaceing wiring/SZ-ERW1/D
Used with
SC-E02RM, E03RM, E04RM,
E05RM
SC-E02RM/G, E03RM/G,
E04RM/G, E05RM/G
Wiring side
Load side
Wiring Cable
UL No3271
AWG12(Dia. Ø2)
Color : Black
30
56
82
Approx. 86
Approx. 22
Approx. 27
105° to 110°
Mass : 13g
Use this connection kit for assembly using the attachment tab of the
thermal overload relay.
Note :
For phase replaceing wiring/SZ-ERW1/B
WiringWiring side
Load side
Used with
SC-E02RM, E03RM, E04RM, E05RM
SC-E02RM/G, E03RM/G, E04RM/G,
E05RM/G
Mass : 17g
When using this connection kit, use a separate mounting thermal
overload relay to connect to the magnetic contactor. If the attachment
tab is used for assembly to the magnetic contactor, interference by
components will make assembly impossible. To assemble using the
attachment tab, use the SZ-ERW1/D type power connection kit.
Note :
86
16
17.5
ø2
5
18.5
30
56
82
For crossover wiring/SZ-ERW2/A
WiringWiring side
Line side
Used with
SC-E1RM, E2RM, E2SRM
SC-E1RM/G, E2RM/G, E2SRM/G
Mass : 48g
When using this connection kit, use a separate mounting thermal
overload relay to connect to the magnetic contactor. If the attachment
tab is used for assembly to the magnetic contactor, interference by
components will make assembly impossible. To assemble using the
attachment tab, use the SZ-ERW2/D type power connection kit.
Note :
106
2.530
17 10.5
30.5
34
67
100
3
02/64
Fuji Electric FA Components & Systems Co., Ltd./D & C Catalog
Information subject to change without notice
DUO series Contactors
SC-E series
Dimensions
Dimensions, mm
For phase replaceing wiring/SZ-ERW2/B
Wiring
Wiring side
Load side
Used with
SC-E1RM, E2RM, E2SRM
SC-E1RM/G, E2RM/G, E2SRM/G
Mass : 42g
When using this connection kit, use a separate mounting thermal
overload relay to connect to the magnetic contactor. If the attachment tab
is used for assembly to the magnetic contactor, interference by
components will make assembly impossible. To assemble using the
attachment tab, use the SZ-ERW2/D type power connection kit.
Note :
106
30.5
17 5.5
34
67
100
3
2.530
For crossover wiring/SZ-ERW3/A
WiringWiring side
Line side
Used with
SC-E3RM, E4RM
SC-E3RM/G, E4RM/G
130.5
17
34.5
6.5
20
34
4
39
80
121
Mass : 162g
When using this connection kit, use a separate mounting thermal
overload relay to connect to the magnetic contactor. If the attachment
tab is used for assembly to the magnetic contactor, interference by
components will make assembly impossible. To assemble using the
attachment tab, use the SZ-ERW3/D type power connection kit.
Note :
For phase replaceing wiring/SZ-ERW3/B
WiringWiring side
Load side
Used with
SC-E3RM, E4RM
SC-E3RM/G, E4RM/G
4
20 9.5
35
35.5
121
80
39
6.5
Mass : 138g
When using this connection kit, use a separate mounting thermal
overload relay to connect to the magnetic contactor. If the attachment
tab is used for assembly to the magnetic contactor, interference by
components will make assembly impossible. To assemble using the
attachment tab, use the SZ-ERW3/D type power connection kit.
Note :
For phase replaceing wiring/SZ-ERW2/D
WiringWiring side
Load side
Used with
SC-E1RM, E2RM, E2SRM
SC-E1RM/G, E2RM/G, E2SRM/G
Mass : 31g
Terminal No. : 4/T2 – 4/T2
Terminal No. : 6/T3 – 2/T1
Terminal No. : 2/T1 – 6/T3
Use this connection kit for assembly using the attachment tab of the
thermal overload relay.
Note :
59
81
Approx. 22
92
8
Approx. 22
1
Approx. 31
Approx. 42
26
8
1
Approx. 31
Approx. 18.5
For phase replaceing wiring/SZ-ERW3/D
WiringWiring side
Load side
Used with
SC-E3RM, E4RM
SC-E3RM/G, E4RM/G
2.5
Approx.
22.5
2910
70
111
10
102.5
2.5
Approx. 28
Approx. 28
Approx. 25.5
Approx. 25.5
Approx. 38.5
Mass : 110g
Terminal No. : 4/T2 – 4/T2
Terminal No. : 6/T3 – 2/T1
Terminal No. : 2/T1 – 6/T3
Use this connection kit for assembly using the attachment tab of the
thermal overload relay.
Note :
Fuji Electric FA Components & Systems Co., Ltd./D & C Catalog
Information subject to change without notice
02/65
02
DUO series Contactors
SC-E series
Dimensions
Dimensions, mm
For crossover wiring/SZ-ERW4/A
For phase replaceing wiring/SZ-ERW4/B
WiringWiring side
Line side
Load side
Used with
SC-E5RM
Type
SZ-ERW4/A
SZ-ERW4/B
23.5 20.5
37
11.5
3.5
36
215
47
111
175
When using this connection kit, use a separate mounting thermal
overload relay to connect to the magnetic contactor.
Note :
Mass : 295g
For crossover wiring/SZ-ERW5/A
For phase replaceing wiring/SZ-ERW5/B
Wiring
Wiring side
Line side
Load side
Used with
SC-E6RM
Type
SZ-ERW5/A
SZ-ERW5/B
23.5 20.5
37
3.5
36
215
175.5
47.5
111.5
11.5
When using this connection kit, use a separate mounting thermal
overload relay to connect to the magnetic contactor.
Note :
Mass : 310g
For crossover wiring/SZ-ERW6/A
For phase replaceing wiring/SZ-ERW6/B
WiringWiring side
Line side
Load side
Used with
SC-E7RM
Type
SZ-ERW6/A
SZ-ERW6/B
15.5
4
41
41.5
25.5 23.5
52.5
122.5
192.5
240
When using this connection kit, use a separate mounting thermal
overload relay to connect to the magnetic contactor.
Note :
Mass : 500g
02/66
Fuji Electric FA Components & Systems Co., Ltd./D & C Catalog
Information subject to change without notice
DUO series Contactors
SC-E series
Operation conditions
Standard operating conditions
The magnetic contactors are manufactured for use in the
standard operating conditions given in the table at the right.
Consult FUJI before using the magnetic contactors in different
conditions.
Wirings
• Connection wires and terminal processing
Be sure to perform wiring correctly with reference to the
connections diagram. Main terminals for models SC-E02 to
SC-E7 are wired using solid wires or stranded wires.
Stranded wires or flexible stranded wires can be connected
by twisting them together, crimping a sleeve (ferrule) onto
them before connecting.
Tightening torque
If wires are not tightened sufficiently, they may become hot or
come loose and result in a fire, short-circuit, electric shock, or
some other potentially dangerous situation. Be sure to tighten
the wires to the torques specified in the tables below.
Connectable wire sizes, tightening tools, tightening torques
Main circuit
Contactor type
Solid wire
(mm
2
)
Stranded wire
(mm
2
) *
1
AWG
Sheath stripping length
(mm)
Te r minal screw size
Tool
Tightening torque (N·m)
One
Two
One
Two
One
Two
SC-E02, SC-E03, SC-E04, SC-E05
0.75 to 6
1 to 4 or 1.5 to 6
0.75 to 6
1 to 4 or 1.5 to 6
18 to 10
18 to 12 or 16 to 10
M4
+
Phillips screwdriver, H-type, No. 2
(ISO 8764)
Flat-blade screwdriver, 1 5.5 L-type, B
(ISO 2830)
1.2 to 1.5
11
SC-E7
4 to 120
2.5 to 95
4 to 95
12 to 250MCM
28.5
4 to 120
2.5 to 95
4 to 95
12 to 250MCM
28.5
4 to 120
2.5 to 95
4 to 95
12 to 250MCM
10
Contactor type SC-E1, E2, E2S
0.75 to 35
0.75 to 25
0.75 to 25
18 to 2
15
0.75 to 25
0.75 to 16
0.75 to 16
18 to 3
12.5
0.75 to 25
0.75 to 16
0.75 to 16
18 to 3
+
Phillips screwdriver, H-type, No. 2
(ISO 8764)
Flat-blade screwdriver, 1 5.5 L-type, B
(ISO 2830)
2.5
1
SC-E3, E4
1 to 70
1 to 50
1 to 50
16 to 2/0
19.5
1 to 50
1 to 35
1 to 35
16 to 1/0
16
1 to 50
1 to 35
1 to 35
16 to 1/0
Hex. wrench 4 (ISO 2936)
8
2
Tool
Tightening torque (N·m)
Self-locking torque (N·m) *
2
SC-E5, E6
2.5 to 70
2.5 to 50
2.5 to 50
12 to 2/0
26.5
2.5 to 70
2.5 to 50
2.5 to 50
12 to 2/0
26.5
2.5 to 70
2.5 to 50
2.5 to 50
12 to 2/0
Top-only
connection
Bottom-only
connection
Top/bottom
connection
Solid or stranded wire (mm
2
) *
1
Flexible stranded wire with sleeve (mm
2
)
Flexible stranded wire without sleeve (mm
2
)
AWG
Sheath stripping length (mm)
Solid or stranded wire (mm
2
) *
1
Flexible stranded wire with sleeve (mm
2
)
Flexible stranded wire without sleeve (mm
2
)
AWG
Sheath stripping length (mm)
Solid or stranded wire (mm
2
) *
1
Flexible stranded wire
with sleeve (mm
2
)
Flexible stranded wire
without sleeve (mm
2
)
AWG
Top/bottom
Top/bottom
Top/bottom
Top/bottom
Operating: –5 to 55˚C
No sudden temperature changes resulting in
condensation or icing (The average temperature over
a 24-hour period must not exceed 35˚C)
Storage:
–40 to 65˚C
45 to 85%RH
2000m or lower
No excessive dust, smoke, corrosive gases,
flammable gases, steam, or salt
10 to 55Hz 15m/s
2
50m/s
2
Screw mounting, 35mm IEC top hat rail mounting
(SC-E02 to SC-E4)
IEC 60947-4-1, EN 60947-4-1, VDE 0660
JIS C 8201-4-1, UL 508, CSA C22.2
TÜV (EN60947-4-1)
Ambient
temperature
Humidity
Altitude
Atmosphere
Vibration
Shock
Mounting
Mounting
angle
Standard
30˚
30˚
30˚
30˚
Solid or stranded
wire (mm
2
)
AWG
Sheath stripping length
(mm)
Fork terminal
Te r minal screw size
Tool
Tightening torque (N·m)
0.75 to 2.5 (ø1 to 1.6)
0.75 to 1.5 or 1.5 to 2.5
18 to 14
18 to 14
Max. 7.7mm wide
M3.5
+
Phillips screwdriver, H-type, No. 2
(ISO 8764)
Flat-blade screwdriver, 1 5.5 L-type, B
(ISO 2830)
0.8 to 1
One
Two
One
Two
10
Notes: *1Stranded wire (0 to 35mm2) consists of 7 wires or less.
Stranded wire (38 to 120mm2) consists of 19 wires or less.
Flexible stranded wire consists of more number wires than the above.
*2The tightening bolt must be loosened in order to insert the wire. However, stop
loosening the bolt when the anti-drop attachment on the bottom of the bolt
reaches the top edge of the terminal. If a torque exceeding that given in the
table is applied in this state, the retaining plate may come loose.
Control circuit
Fuji Electric FA Components & Systems Co., Ltd./D & C Catalog
Information subject to change without notice
02/67
02
DUO series Contactors
SC-E series
Operating conditions
Connectable wire size and tightening torque (Ring terminal connection type)
Contactor
type
Te r minal
screw *
1
Connectable
wire size (mm
2
)
Applicable ring terminal
max. width (mm) *
2
Tightening torque
(N·m)
Coil terminal
(Contactor)
Coil terminal
(Contactor)
Coil terminal
(Contactor)
Coil terminal
(Contactor)
SC-E02P to
E4P
M3.5 1.25 to 2
(1.2 to 2mm dia.)
7.7
(R1.25-3.5 to R2-3.5)
0.8 to 1.0
Note 1 The motor starter has plus-minus shaped terminal screws of (M4, M5).
Note 2 Two wires or two crimp terminals can be connected to each terminal.
Note 3 Use insulation caps to use ring crimp terminals.
*
1
: Cross-recessed pan-head screw : Non-oriented square washer, turtleback washer
: Circular bright plain washer : Cross-recessed hexagonal head bolt
*
2
Round crimp terminal JIS C 2805
*
3
Use crimp terminals of max. width or less. (Use narrow-width terminals made by crimp terminal manufacturers.)
*
4
Use crimp terminal manufacturers’ standard models.
Control circuit
Contactor
type
Te r minal
screw *
1
Connectable
wire size (mm
2
)
Applicable ring terminal
max. width (mm) *
2
*
4
Tightening torque
(N·m)
SC-E02P to
E05P
M4 1.25 to 6 9.7
(R1.25-4 to R5.5-4)
1.2 to 1.5
SC-E1P to
E2SP
M5 2 to 22 12.4 *
3
(R2-5 to R22-5)
2.0 to 2.5
SC-E3P,
E4P
M6 2 to 38 16.7 *
3
(R2-6 to R38-6)
4.0 to 5.0
Main circuit