Users should evaluate the suitability of this product for their application. Specifications are subject to change without notice.
Tyco Electronics also reserves the right to make changes in materials or processing, which do not affect compliance with any specification, without notification to Buyer.
1/ COLORS AND COLOR CODE DESIGNATORS SHALL BE IN ACCORDANCE WITH MIL-STD-681. HOWEVER, DUE TO LENGTH LIMITATIONS OF THE RAYCHEM PART NUMBER,
AN ALTERNATIVE COLOR CODE MAY REPLACE MIL-STD-681 COLOR CODE DESIGNATORS. (EXAMPLE: "901/902..." MAY BE REPLACED BY "Axxx".) OTHER CODES AND
SUFFIXES MAY BE ADDED TO THE PART NUMBER, AS NECESSARY, TO CAPTURE ANY ADDITIONAL REQUIREMENTS IMPOSED BY THE PURCHASE ORDER.
DIMENSIONS ARE IN INCHES AND, UNLESS OTHERWISE DESIGNATED, ARE NOMINAL.
THIS SPECIFICATION SHEET TAKES PRECEDENCE OVER DOCUMENTS REFERENCED HEREIN.
REFERENCED DOCUMENTS SHALL BE OF THE ISSUE IN EFFECT ON DATE OF INVITATION FOR BID.
Wire & Cable
501 Oakside Avenue
Redwood City, CA 94063-3800
Phone: 1-800-227-8816
Fax: 1-650-361-6297
SPECIFICATION CONTROL DRAWING 44A022X
Title
TWO CONDUCTOR CABLE, RADIATION-CROSSLINKED POLYALKENE INSULATED,
UNSHIELDED, UNJACKETED, LIGHTWEIGHT,GENERAL PURPOSE, 1000 VOLT
Date
01-20-04
Revision
B
This specification sheet forms a part of the latest issue of Raychem Specification 44 and MIL-W-81044 as applicable.
COMPONENT WIRES – 44A021X
CABLE CONSTRUCTION DETAILS
OUTSIDE DIAMETER
(inches)
PART NUMBER
1/
CONDUCTOR
SIZE
(AWG)
NOMINAL MAXIMUM
MAXIMUM
WEIGHT
(lbs/1000 ft)
44A022X-26-* 26 .080 .085 3.2
44A022X-24-* 24 .092 .097 4.8
44A022X-22-* 22 .108 .114 7.0
44A022X-20-* 20 .124 .130 10.4
44A022X-18-* 18 .146 .152 15.4
44A022X-16-* 16 .162 .169 19.6
44A022X-14-* 14 .196 .203 29.6
44A022X-12-* 12 .234 .242 44.4
44A022X-10-* 10 .292 .302 71.7
44A022X- 8-* 8 .412 .433 125.
44A022X- 6-* 6 .508 .533 190.
44A022X- 4-* 4 .616 .647 302.
CABLE RATINGS AND ADDITIONAL REQUIREMENTS
TEMPERATURE RATING: 150°C
Maximum continuous conductor temperature
VOLTAGE RATING: 1000 volts (rms) at sea level
INSULATION FLAWS:
Spark Test, 4.0 kV (rms) at 3 kHz
Impulse Dielectric Test, 8.0 kV (peak)
The "X" in the part numbers above shall be replaced with a
conductor material designator as follows:
1 tin-coated copper
2 silver-coated copper
3 nickel-coated copper
4 silver-coated high strength copper alloy
The "*" in the part numbers above shall be replaced
by color code designators with a slash separating
component wire colors:
1/ Example: AWG 20, tin-coated copper wires;
black and white components:
44A0221-20-0/9
NOTE: Nominal values are for information only
Nominal values are not requirements.
Page 1 of 1