HLG-100H 100W Single Output Switching Power Supply series Features : Universal AC input / Full range (up to 305VAC) Built-in active PFC function High efficiency up to 93% Protections: Short circuit / Over current / Over voltage / Over temperature Cooling by free air convection OCP point adjustable through output cable or internal potentiometer IP67 / IP65 design for indoor or outdoor installations Class 2 power unit Three in one dimming function (1~10Vdc or PWM signal or resistance) Suitable for LED lighting and street lighting applications Compliance to worldwide safety regulations for lighting Suitable for dry / damp / wet locations 5 years warranty (Note.10) F HLG-100H-20 A 110 M M Bauar t gepruft Sicherheit IP65 IP67 SELV egel ma ge od o s be wac g www. tuv.com ID 2000000000 Blank : IP67 rated. Cable for I/O connection. A : IP65 rated. Output voltage and constant current level can be adjusted through internal potentiometer. B : IP67 rated. Constant current level adjustable through output cable with 1~10Vdc or 10V PWM signal or resistance. D (option, safety pending) : IP67 rated. Timer dimming function, contact MEAN WELL for details. SPECIFICATION MODEL DC VOLTAGE HLG-100H-20 HLG-100H-24 HLG-100H-30 HLG-100H-36 HLG-100H-42 HLG-100H-48 HLG-100H-54 20V 24V 30V 36V 42V 48V 54V 12 ~ 24V 21 ~ 42V 24 ~ 48V 27 ~ 54V 4.8A 4A 15 ~ 30V 3.2A 18 ~ 36V RATED CURRENT 2.65A 2.28A 2A 1.77A RATED POWER 96W 96W 96W 95.4W 95.76W 96W 95.58W RIPPLE & NOISE (max.) Note.2 150mVp-p 150mVp-p 200mVp-p 200mVp-p 200mVp-p 200mVp-p 200mVp-p VOLTAGE ADJ. RANGE Note.6 17 ~ 22V 22 ~ 27V 27 ~ 33V 33 ~ 40V 38 ~ 46V 43 ~ 53V 49 ~ 58V CONSTANT CURRENT REGION Note.4 10 ~ 20V OUTPUT Can be adjusted by internal potentiometer A type only CURRENT ADJ. RANGE 3 ~ 4.8A 2.5 ~ 4A 2 ~ 3.2A 1.65 ~ 2.65A 1.4 ~ 2.28A 1.25 ~ 2A 1.1 ~ 1.77A VOLTAGE TOLERANCE Note.3 1.0% 1.0% 1.0% 1.0% 1.0% 1.0% 1.0% LINE REGULATION 0.5% 0.5% 0.5% 0.5% 0.5% 0.5% 0.5% LOAD REGULATION 0.5% 0.5% 0.5% 0.5% 0.5% 0.5% 0.5% SETUP, RISE TIME Note.8 1200ms,50ms/115VAC 16ms at full load HOLD UP TIME (Typ.) VOLTAGE RANGE Note.5 90 ~ 305VAC FREQUENCY RANGE 500ms,50ms/230VAC at full load ; B type 1200ms,200ms/115VAC 500ms,200ms/230VAC at 95% load 230VAC /115VAC 127 ~ 431VDC 47 ~ 63Hz PF>0.98/115VAC, PF>0.95/230VAC, PF>0.93/277VAC at full load (Please refer to "Power Factor Characteristic" curve) POWER FACTOR (Typ.) TOTAL HARMONIC DISTORTION THD< 20% when output loading60% at 115VAC/230VAC input and output loading75% at 277VAC input INPUT EFFICIENCY (Typ.) AC CURRENT (Typ.) INRUSH CURRENT (Typ.) MAX. No. of PSUs on 16A CIRCUIT BREAKER LEAKAGE CURRENT OVER CURRENT PROTECTION SHORT CIRCUIT OVER VOLTAGE 93% 93% 93% 93% 1.2A / 115VAC 0.55A / 230VAC 0.5A / 277VAC COLD START 60A(twidth=415s measured at 50% Ipeak) at 230VAC 93% <0.75mA / 277VAC 95 ~ 106% Protection type : Constant current limiting, recovers automatically after fault condition is removed Constant current limiting, recovers automatically after fault condition is removed 47 ~ 53V 34 ~ 38V 28 ~ 34V 41 ~ 46V 54 ~ 63V 23 ~ 27V Shut down o/p voltage, recovers automatically after temperature goes down -40 ~ +70 (Refer to "Derating Curve") SAFETY STANDARDS Note.7 20 ~ 95% RH non-condensing -40 ~ +80, 10 ~ 95% RH 0.03%/ (0 ~ 50) 10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axes UL8750, CSA C22.2 No. 250.0-08, EN61347-1, EN61347-2-13 independent IP65 or IP67, J61347-1, J61347-2-13 approved ; design refer to UL60950-1, TUV EN60950-1 SAFETY & WITHSTAND VOLTAGE I/P-O/P:3.75KVAC EMC I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25/ 70% RH Compliance to EN55015, EN55022 (CISPR22) Class B, EN61000-3-2 Class C (60% load) ; EN61000-3-3 ISOLATION RESISTANCE EMC EMISSION EMC IMMUNITY MTBF OTHERS DIMENSION PACKING NOTE 59 ~ 65V Protection type : Shut down o/p voltage with auto-recovery or re-power on to recovery WORKING TEMP. VIBRATION 93% 4 units (circuit breaker of type B) / 8 units (circuit breaker of type C) at 230VAC OVER TEMPERATURE WORKING HUMIDITY ENVIRONMENT STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT 93% I/P-FG:2KVAC O/P-FG:1.5KVAC Compliance to EN61000-4-2,3,4,5,6,8,11, EN61547, EN55024, light industry level (surge 4KV), criteria A 192.2K hrs min. MIL-HDBK-217F (25) 220*68*38.8mm (L*W*H) 1.12Kg; 12pcs/14.4Kg/0.8CUFT 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. Please refer to "DRIVING METHODS OF LED MODULE". 5. Derating may be needed under low input voltages. Please check the static characteristics for more details. 6. A type only. 7. Safety and EMC design refer to EN60598-1, CNS15233, GB7000.1, FCC part18. 8. Length of set up time is measured at cold first start. Turning ON/OFF the power supply may lead to increase of the set up time. 9. The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again. 10. Refer to warranty statement. 11. To fulfill requirements of the latest ErP regulation for lighting fixtures, this LED power supply can only be used behind a switch without permanently connected to the mains. File Name:HLG-100H-SPEC 2015-05-11 HLG-100H 100W Single Output Switching Power Supply Mechanical Specification Case No.994A series Unit:mm Blank:(HLG-100H) 220 196 12 9.4 9.6 34.2 T case 68 30020 FG (Green/Yellow) AC/L(Brown) AC/N(Blue) 98 30020 9.4 34 SJTW 18AWGx3C SJTW 14AWGx2C 4.2x4PL -V(Black) +V(Red) 38.8 T case: Max. Case Temperature. IP67 rated. Cable for I/O connection. A Type:(HLG-100H-_A) 220 196 12 9.4 9.6 34.2 Vo ADJ. T case 68 30020 FG (Green/Yellow) AC/L(Brown) AC/N(Blue) 98 9.4 34 SJTW 18AWGx3C Io ADJ. 30020 SJTW 14AWGx2C 4.2x4PL -V(Black) +V(Red) 38.8 T case: Max. Case Temperature. IP65 rated. Output voltage and constant current level can be adjusted through internal potentiometer. (Can access by removing the rubber stopper on the case.) B Type:(HLG-100H-_B) 220 196 12 9.6 9.4 30020 SJTW 18AWGx2C T case 68 98 SJTW 14AWGx2C 34 34.2 SJTW 18AWGx3C 9.4 4.2x4PL DIM+(Blue) DIM-(White) -V(Black) +V(Red) T case: Max. Case Temperature. 38.8 FG (Green/Yellow) AC/L(Brown) AC/N(Blue) 30020 File Name:HLG-100H-SPEC 2015-05-11 HLG-100H 100W Single Output Switching Power Supply series D Type(option):(HLG-100H-_D) 220 196 12 9.4 9.6 34.2 T case 98 68 30020 FG (Green/Yellow) AC/L(Brown) AC/N(Blue) 30020 9.4 34 SJTW 18AWGx3C -V(Black) +V(Red) SJTW 14AWGx2C 4.2x4PL 38.8 T case: Max. Case Temperature. IP67 rated. Timer dimming function, contact MEAN WELL for details. Block Diagram Fosc : 100KHz EMI FILTER & RECTIFIERS I/P RECTIFIERS & FILTER POWER SWITCHING PFC CIRCUIT +V -V DIM+ DIM(B Type) O.L.P. FG DETECTION CIRCUIT O.L.P. PFC CONTROL PWM CONTROL O.T.P. O.V.P. Derating Curve Static Characteristics 100 100 90 80 80 70 LOAD (%) LOAD (%) 60 40 20 -40 -25 -10 0 15 30 50 AMBIENT TEMPERATURE () 60 70 (HORIZONTAL) 60 50 40 90 100 125 135 145 155 165 175 180 200 230 305 INPUT VOLTAGE (V) 60Hz File Name:HLG-100H-SPEC 2015-05-11 HLG-100H 100W Single Output Switching Power Supply series Power Factor Characteristic Constant Current Mode PF 1 .0 0 0 .9 8 0 .9 6 0 .9 4 0 .9 2 0 .9 0 0 .8 8 0 .8 6 0 .8 4 0 .8 2 0 .8 0 0 .7 8 277V ac 230V ac 115V ac 50% 60% 70% 80% 90% 100% (100W) LOAD EFFICIENCY vs LOAD (48V Model) HLG-100H series possess superior working efficiency that up to 93% can be reached in field applications. 94 EFFICIENCY (%) 90 86 82 78 277Vac 74 230Vac 70 115Vac 66 62 58 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% LOAD DRIVING METHODS OF LED MODULE There are two major kinds of LED drive method "direct drive" and "with LED driver". A typical LED power supply may either work in "constant voltage mode (CV) or constant current mode (CC)" to drive the LEDs. Mean Well's LED power supply with CV+ CC characteristic can be operated at both CV mode (with LED driver, at area (A) and CC mode (direct drive, at area (B). In the constant current region, the highest voltage at the output of the driver depends on the configuration of the end systems. 100 Should there be any compatibility issues, please contact MEAN WELL. (A) Constant Voltage area Vo(%) (B) Constant Current region 50 100 Io (%) Typical LED power supply I-V curve File Name:HLG-100H-SPEC 2015-05-11 HLG-100H 100W Single Output Switching Power Supply series DIMMING OPERATION (for B-type only) FG (Green/Yellow) AC/L(Brown) AC/N(Blue) DIM+(Blue) DIM-(White) HLG-100H -V(Black) +V(Red) Built-in 3 in 1 dimming function, IP67 rated. Output constant current level can be adjusted through output cable by connecting a resistance or 1 ~ 10Vdc or 10V PWM signal between DIM+ and DIM-. Please DO NOT connect "DIM-" to "-V". Reference resistance value for output current adjustment (Typical) Single driver 10K 20K 30K 40K 50K 60K 70K 80K 90K 100K Resistance Multiple drivers value (N=driver quantity for synchronized 10K/N 20K/N 30K/N 40K/N 50K/N 60K/N 70K/N 80K/N 90K/N 100K/N dimming operation) Percentage of rated current 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% OPEN ----95%~108% 1 ~ 10V dimming function for output current adjustment (Typical) Dimming value 1V 2V 3V 4V 5V 6V 7V 8V 9V 10V OPEN Percentage of rated current 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% 95%~108% 10V PWM signal for output current adjustment (Typical): Frequency range :100Hz ~ 3KHz Duty value 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% OPEN Percentage of rated current 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% 95%~108% Using the built-in dimming function on B-type model can't turn the lighting fixture totally dark. Please refer to the connection method below to achieve 0% brightness of the lighting fixture connecting to the LED power supply unit. Direct connecting to LEDs is suggested, but is not suitable for using additional drivers. Dimming connection diagram for turning the lighting fixture ON/OFF : N FG L Switch Relay Adjuster 10K~100K Ohms resistance 1~10V DC Voltage 10V PWM Signal Green/ Yellow Brown Blue AC/L HLG-100H B Type AC/N DIM+ DIMV(-) V(+) Blue White Black Red LED Lighting Fixture Using a switch and relay can turn ON/OFF the lighting fixture. 1.Output constant current level can be adjusted through output cable by connecting a resistance or 1~10Vdc or 10V PWM signal between DIM+ and DIM-. 2.The LED lighting fixture can be turned ON/OFF by the switch. File Name:HLG-100H-SPEC 2015-05-11 HLG-100H 100W Single Output Switching Power Supply series WATERPROOF CONNECTION Waterproof connector Waterproof connector can be assembled on the output cable of HLG-100H to operate in dry/wet/damp or outdoor environment. AC source HLG-100H I/P O/P Size Size Pin Configuration (Female) M12 Order No. Suitable Current 4-PIN 5A/PIN M12-04 10A max. Pin Configuration (Female) M15 5-PIN 5A/PIN M12-05 10A max. 2-PIN 12A/PIN M15-02 12A max. Order No. Suitable Current LED Lamp Cable Joiner CJ04-1 suitable for 14AWG~16AWG CJ04-2 suitable for 18AWG~22AWG 20 25 66 26 Up to four wires can be connected through this cable joiner by soldering or clamping by tools. LED Lamp HLG-100H O/P Wires CJ04 cable joiner can be purchased independently for user's own assembly. MEAN WELL order No. : CJ04-1, CJ04-2. Junction Box(Option ) 10 76 5 8.5 SJTW 18AWGx3C -V(Black) +V(Red) 32 68 FG (Green/Yellow) AC/L(Brown) AC/N(Blue) 61 8.5 6 196 358 SJTW 14AWGx2C 2-5 3- PF 1/2" 3- PF 1/2" 15020 35 38.8 15020 Optional junction box available for A / Blank - type , please contact MEAW WELL for details. 86 File Name:HLG-100H-SPEC 2015-05-11 Mouser Electronics Authorized Distributor Click to View Pricing, Inventory, Delivery & Lifecycle Information: Mean Well: HLG-100H-20 HLG-100H-20A HLG-100H-20B HLG-100H-24 HLG-100H-24A HLG-100H-24B HLG-100H-30 HLG100H-30A HLG-100H-30B HLG-100H-36 HLG-100H-36A HLG-100H-36B HLG-100H-42 HLG-100H-42A HLG100H-42B HLG-100H-48 HLG-100H-48A HLG-100H-48B HLG-100H-54 HLG-100H-54A HLG-100H-54B HLG100H-54AB HLG-100H-48AB HLG-100H-36AB HLG-100H-20AB HLG-100H-42AB HLG-100H-30AB HLG-100H24AB