2
Electrical connection 1 conductor(s)rigid cable , connection via cage type connector 2.5 mm²/AWG 14
for control circuit
1 conductor(s)rigid cable , connection via cage type connector 2.5 mm²/AWG 14
for power circuit
2 conductor(s)rigid cable , connection via cage type connector 1 mm²/AWG 17 for
control circuit
2 conductor(s)rigid cable , connection via cage type connector 1 mm²/AWG 17 for
power circuit
1 conductor(s)flexible cable with cable end, connection via cage type connector
2.5 mm²/AWG 14 for control circuit
1 conductor(s)flexible cable with cable end, connection via cage type connector
2.5 mm²/AWG 14 for power circuit
1 conductor(s)flexible cable without cable end, connection via cage type
connector 2.5 mm²/AWG 14 for control circuit
1 conductor(s)flexible cable without cable end, connection via cage type
connector 2.5 mm²/AWG 14 for power circuit
2 conductor(s)flexible cable with cable end, connection via cage type connector
0.75 mm²/AWG 18 for control circuit
2 conductor(s)flexible cable with cable end, connection via cage type connector
0.75 mm²/AWG 18 for power circuit
2 conductor(s)flexible cable without cable end, connection via cage type
connector 1 mm²/AWG 17 for control circuit
2 conductor(s)flexible cable without cable end, connection via cage type
connector 1 mm²/AWG 17 for power circuit
Marking CE
Operating position Vertical +/- 10 degree
Product weight 0.16 kg
Environment
Electromagnetic compatibility Conducted and radiated emissions conforming to CISPR 11 level B
Conducted and radiated emissions conforming to IEC 60947-4-2 level B
Damped oscillating waves conforming to IEC 61000-4-12 level 3
Electrostatic discharge conforming to IEC 61000-4-2 level 3
EMC immunity conforming to EN 50082-1
EMC immunity conforming to EN 50082-2
Harmonics conforming to IEC 1000-3-2
Harmonics conforming to IEC 1000-3-4
Immunity to conducted interference caused by radio-electrical fields conforming
to IEC 61000-4-6 level 3
Immunity to electrical transients conforming to IEC 61000-4-4 level 4
Immunity to radiated radio-electrical interference conforming to IEC 61000-4-3
level 3
Micro-cuts and voltage fluctuation conforming to IEC 61000-4-11
Voltage/Current impulse conforming to IEC 61000-4-5 level 3
Standards EN/IEC 60947-4-2
Product certifications B44.1-96/ASME A17.5 for starter wired to the motor delta terminal
CCC
CSA
C-Tick
GOST
UL
IP degree of protection IP20
Pollution degree 2 conforming to EN/IEC 60947-4-2
Vibration resistance 1 gn (f = 13...150 Hz) conforming to EN/IEC 60068-2-6
1.5 mm peak to peak (f = 3...13 Hz) conforming to EN/IEC 60068-2-6
Shock resistance 15 gn for 11 ms conforming to EN/IEC 60068-2-27
Relative humidity 5...95 % without condensation or dripping water conforming to EN/IEC 60068-2-3
Ambient air temperature for operation -10...40 °C without derating
40...50 °C with current derating of 2 % per °C
Ambient air temperature for storage -25...70 °C conforming to EN/IEC 60947-4-2
Operating altitude <= 1000 m without derating
> 1000 m with current derating of 2.2 % per additional 100 m
RoHS EUR status Compliant
RoHS EUR conformity date 0905