Solid-state Timer
H3Y Series
Miniature Timer Compatible with
the MY Relay
The Push-In Plus Terminal Block Socket-compatible
H3Y-@-B/H3YN-@-B Timers in a black design join the
Single-mode H3Y and Multi-mode H3YN.
•The H3Y-@-B and H3YN-@-B are UL listed when they
are used together with Push-In Plus Terminal Block
Sockets.
Large transparent time setting knob facilitates time
setting.
A flat-blade and Phillips screwdriver can also be used
for time setting.
Conforms to EMC standards.
Conforms to EN 61812-1 and approved by UL and CSA.
Model Number Structure
For the most recent information on models that have been certified for
safety standards, refer to your OMRON website.
LR
H3Y Series
H3Y
Mono-function Timers
H3YN
Multi Timers
G On Delay
G Fixed Time Range
G On Delay
G Fixed Time Range
G Four-mode Timers
ON Delay
Interval
Flicker-OFF Start
Flicker-ON Start
G Four-time Ranges
Short-time range (0.1 s to 10 min)
Long-time range (0.1 min to 10 hrs)
G Bifurcated contacts
G Four-mode Timers
ON Delay
Interval
Flicker-OFF Start
Flicker-ON Start
G Four-time Ranges
S
hort-time range (0.1 s to 10 min)
Long-time range (0.1 min to 10 hrs)
G Bifurcated contacts
H3Y-@-B
Mono-function Timers
H3YN-@-B
Multi Timers
Refer to page 3.
The Entire H3Y Series
Refer to page 9. Refer to page 17. Refer to page 23.
H3Y Series
2
Model Number Structure
Note: Specify both the model number, supply voltage, and rated time when ordering.
Note: Specify both the model number, supply voltage when ordering.
H3Y- @ - @ - @
(1) (2) (3)
(1) Output (2) Terminal Type (3) Body Color and Terminal Arrangement
Symbol Meaning Symbol Meaning Symbol Meaning
2 DPDT None Plug-in terminals None Beige with output terminals on top and power
supply terminals on bottom
4 4PDT 0 PCB terminals B Black with power supply terminals on top and
output terminals on bottom
Ex) H3Y-2 100 to 120VAC 0.5S
Supply Voltage
Rated time
H3YN - @ @ @ - @
(1) (2) (3) (4)
(1) Output (2) Time Range (3) Contact Type
Symbol Meaning Symbol Meaning Symbol Meaning
2 DPDT None Short-time range None Single contact
4 4PDT 0 Long-time range Z Twin contacts
(4) Body Color and Terminal Arrangement
Symbol Meaning
None Beige with output terminals on top and power supply terminals on bottom
B Black with power supply terminals on top and output terminals on bottom
Ex) H3YN-2 100 to 120VAC
Supply Voltage
3
Solid-state Timer
H3Y
Miniature Timer Compatible with
the MY Relay
Semi-multi power supply voltage.
Large transparent time setting knob facilitates time
setting.
A flat-blade and Phillips screwdriver can also be
used for time setting.
Pin configuration compatible with MY Power Relay.
LED indication for power and output statuses.
Conforms to EMC standards.
Conforms to EN 61812-1 and approved by UL and
CSA.
Ordering Information
Note: Sockets and Hold-down Clips are not included with the H3Y. They must be ordered separately.
*Use the H3Y-4 or H3Y-4-0 Series when switching micro loads.
Accessories (Order Separately)
Adapter, Mounting Plate, Hold-down Clips
Note: For details, refer to Precautions for H3Y-series Timers on page
31.
Socket
Note: 1. Cannot be used with the H3Y-@-0 (PCB terminals).
2.
The PYF
@@
A-E has a finger-protection structure. Round crimp
terminals cannot be used. Use forked crimp terminals.
For the most recent information on models that have been certified for
safety standards, refer to your OMRON website.
LR
Refer to Safety Precautions on page 36.
Operation/
resetting system Time-limit contact Time ranges Supply voltage
Mounting
Surface/DIN-track
mounting
(with socket)
Surface mounting
(with PCB terminals)
Time-limit
operation/
self-resetting
DPDT (for power
switching) 0.04 s to 3 h
24, 100 to 120, 200 to 230,
240 VAC (50/60 Hz);
12, 24, 48, 125, 100 to
110 VDC
H3Y-2 H3Y-2-0
4PDT H3Y-4 *H3Y-4-0 *
Name/specification Model
Flush mounting adapter Y92F-78
Mounting
Plate for
Socket
For 1 Socket PYP-1
For 18
Sockets PYP-18
Hold-down
Clips
For PYF@A Y92H-3
For PY@ and
PYF@MY92H-4
Timer Square Sockets
Contact Model Pin
Connection
Terminal Model
DPDT H3Y-2 8-pin
Front
Connecting
DIN track
mounting PYF08A
DIN track
mounting
(Finger
Protection
Structure)
PYF08A-E
Screw
mounting PYF08M
Back
Connecting
Solder
terminal PY08
PCB
terminal PY08-02
4PDT H3Y-4
14-pin
Front
Connecting
DIN track
mounting PYF14A
DIN track
mounting
(Finger
Protection
Structure)
PYF14A-E
Back
Connecting
Solder
terminal PY14
PCB
terminal PY14-02
H3Y
4
Specifications
Time Ranges
Ratings
*1. Do not use the output from an inverter as the power supply. Refer to Safety Precautions for All Timers for details on your OMRON website.
*2. With DC ratings, single-phase full-wave rectified power sources may be used.
*3. Only the H3Y-2 and H3Y-2-0 Series include 12 VDC models.
*4. Use the Timer within 90% to 110% of the rated supply voltage (95% to 110% for 12 VDC) when using it continuously under an ambient
operating temperature of 50°C.
*5. Set the reset voltage as follows to ensure proper resetting.
100 to 120 VAC: 10 VAC max.
200 to 230 VAC: 20 VAC max.
100 to 110 VDC: 10 VDC max.
*6. Refer to Safety Precautions for All Timers on your OMRON website when combining the Timer with an AC 2-wire proximity sensor.
*7. A diode to prevent reverse voltages is provided only on models with a DC power supply.
Rated time Time setting range Rated time Time setting range
0.5 s 0.04 to 0.5 s 3 min 0.1 to 3 min
1 s 0.1 to 1 s 5 min 0.2 to 5 min
5 s 0.2 to 5 s 10 min 0.5 to 10 min
10 s 0.5 to 10 s 30 min 1 to 30 min
30 s 1.0 to 30 s 60 min 2 to 60 min
60 s 2.0 to 60 s 3 h 0.1 to 3 h
120 s 5.0 to 120 s --- ---
Item H3Y-2(-0)/H3Y-4(-0)
Rated supply voltage *6, *7100 to 120 (50/60 Hz), 200 to 230 VAC (50/60 Hz), 24 VAC (50/60 Hz) *1
12, 24, 48, 125, 100 to 110 VDC *2, *3
Operating voltage range All rated voltages except 12 VDC: 85% to 110% of rated supply voltage
12 VDC: 90% to 110% of rated supply voltage *4
Reset voltage 10% min. of rated supply voltage *5
Power consumption
100 to 120 VAC: 1.5 VA (at 120 VAC)
200 to 230 VAC: 1.8 VA (at 230 VAC)
24 VAC: 1.5 VA (at 24 VAC)
12 VDC: 0.9 W (at 12 VDC)
24 VDC: 0.9 W (at 24 VDC)
48 VDC: 1.0 W (at 48 VDC)
100 to 110 VDC: 1.3 W (at 110 VDC)
125 VDC: 1.3 W (at 125 VDC)
Control outputs
H3Y-2(-0):
5 A at 250 VAC, resistive load (cosφ = 1)
The minimum applicable load is 1 mA at 5 VDC (P reference value).
Contact materials: Ag
H3Y-4(-0):
3 A at 250 VAC, resistive load (cosφ = 1)
The minimum applicable load is 1 mA at 1 VDC (P reference value).
Contact materials: Au-clad + Ag-alloy
Ambient operating temperature -10°C to 50°C (with no icing)
Storage temperature -25°C to 65°C
Ambient operating humidity 35% to 85%
H3Y
5
Characteristics
*1. Add ±10 mS to the above value for the 0.5-S range model.
*2. Terminal screw sections are excluded.
*3. The destructive shock resistance test was performed on the Timer.
*4. Check the electrical life curve.
*5. Overvoltage category II.
*6. CCC certification requirements
Accuracy of operating time ±1% FS max. (0.5 s range: ±1%±10 ms max.) *1
Setting error ±10%±50 ms FS max.
Reset time Min. power-opening time: 0.1 s max. (including halfway reset)
Influence of voltage ±2% FS max. *1
Influence of temperature ±2% FS max. *1
Insulation resistance 100 MΩ min. (at 500 VDC)
Dielectric strength
2,000 VAC, 50/60 Hz for 1 min
(between current-carrying terminals and exposed non-current-carrying metal parts) *2
2,000 VAC, 50/60 Hz for 1 min (between operating power circuit and control output) *2
2,000 VAC, 50/60 Hz for 1 min (between different pole contacts; 2-pole model) *2
1,500 VAC, 50/60 Hz for 1 min (between different pole contacts; 4-pole model)
1,000 VAC, 50/60 Hz for 1 min (between non-continuous contacts)
Impulse withstand voltage
Between power terminals:
3 kV for 100 to 120 VAC, 200 to 230 VAC, 100 to 110 VDC, 125 VDC
1 kV for 12 VDC, 24 VDC, 48 VDC
Between exposed non-current-carrying metal parts:
4.5 kV for 100 to 120 VAC, 200 to 230 VAC, 100 to 110 VDC, 125 VDC
1.5 kV for 12 VDC, 24 VDC, 48 VDC
Noise immunity ±1.5 kV, square-wave noise by noise simulator (pulse width: 100 ns/1 μs, 1-ns rise)
Static immunity Destruction: 8 kV
Malfunction: 4 kV
Vibration resistance Destruction: 10 to 55 Hz, 0.75-mm single amplitude
Malfunction: 10 to 55 Hz, 0.5-mm single amplitude
Shock resistance Destruction: 1,000 m/s2 (approx. 100G) *3
Malfunction: 100 m/s2 (approx. 10G)
Life expectancy
Mechanical:10,000,000 operations min. (under no load at 1,800 operations/h)
Electrical:
H3Y-2: 500,000 operations min. (5 A at 250 VAC, resistive load at 1800 operations/h)
H3Y-4: 200,000 operations min. (3 A at 250 VAC, resistive load at 1800 operations/h) *4
Enclosure rating IP40
Weight Approx. 50 g
EMC
(EMI) EN 61812-1
Emission Enclosure: EN 55011 Group 1 class A
Emission AC Mains: EN 55011 Group 1 class A
(EMS) EN 61812-1
Immunity ESD: IEC 61000-4-2
Immunity RF-interference: IEC 61000-4-3
Immunity Burst: IEC 61000-4-4
Immunity Surge: IEC 61000-4-5
Immunity Conducted Disturbance: IEC 61000-4-6
Immunity Voltage Dip/Interruption: IEC 61000-4-11
Approved standards UL 508, CSA C22.2 No. 14, Lloyds, CCC: GB/T 14048.5 *6
Conforms to EN 61812-1 and IEC 60664-1. (2.5 kV/2 for H3Y-2/-2-0, 2.5 kV/1 for H3Y-4/-4-0) *5
Model H3Y-2 (-0) H3Y-4 (-0)
Recommended fuse RT14-20/6A (380 VAC 6 A), manufactured by
DELIXI
RT14-20/4A (380 VAC 4 A), manufactured by
DELIXI
Rated operating voltage Ue
Rated operating current Ie
AC-15: Ue: 250 VAC, Ie: 3 A
AC-13: Ue: 250 VAC, Ie: 5 A
DC-13: Ue: 30 VDC, Ie: 0.5 A
AC-15: Ue: 250 VAC, Ie: 2 A
AC-13: Ue: 250 VAC, Ie: 3 A
DC-13: Ue: 30 VDC, Ie: 0.5 A
Rated insulation voltage 250 V
Rated impulse withstand voltage
(altitude: 2,000 m max.) 2.5 kV (at 240 VAC)
Conditional short-circuit current 1000 A
H3Y
6
Engineering Data
Connections
Connections
H3Y-2, H3Y-2-0
Switching operations (×104)
Load current (A)
H3Y-2, H3Y-2-0
H3Y-4, H3Y-4-0
Load current (A)
Load current (A)
H3Y-4, H3Y-4-0
Load current (A)
Reference: A maximum current of 0.6 A can be switched at 125 VDC (cosφ = 1).
Maximum current of 0.2 A can be switched if L/R is 7 ms. In both
cases, a life of 100,000 operations can be expected.The minimum
applicable load is 1 mA at 5 VDC (P reference value).
Reference: A maximum current of 0.5 A can be switched at 125 VDC (cosφ = 1).
Maximum current of 0.2 A can be switched if L/R is 7 ms. In both
cases, a life of 100,000 operations can be expected.The minimum
applicable load is 1 mA at 1 VDC (P reference value).
Switching operations (×104)
Switching operations (×104)
Switching operations (×104)
250 VAC, cosφ = 0.4
24 VDC, L/R = 7 ms
250 VAC, cosφ = 1
24 VDC, cosφ = 1
250 VAC, cosφ = 1
24 VDC, cosφ = 1
250 VAC, cosφ = 0.4
24 VDC, L/R = 7 ms
500
100
50
20
500
100
50
20
500
100
50
20
500
100
50
20
H3Y
7
Operation
Timing Chart
Nomenclature
H3Y-2, H3Y-2-0 H3Y-4, H3Y-4-0
NC NC
Note: t = Set time
Rt = Reset time
Note: t = Set time
Rt = Reset time
Run/Power Indicator (Green)
(Lit: Power ON)
Output Indicator (Orange)
(Lit: Output ON)
Main Dial
H3Y
8
Dimensions (Unit: mm)
Timers
(63.0)
6.4
6.3
28 max.
21.5
max.
H3Y-2
Mounting Holes
(60.7)
28 max.
6.3
21.5
max.
Eight,
1.3-dia. holes
Pin 1
H3Y-2-0
(63.0)
6.4
6.3
21.5
max.
28 max.
H3Y-4
Mounting Holes
(60.7)
28 max.
6.3
21.5
max.
Fourteen,
1.3-dia. holes
Pin 1
H3Y-4-0
9
Solid-state Timer
H3YN
Miniature Timer with Multiple Time
Ranges and Multiple Operating Modes
Minimizes stock.
Pin configuration compatible with MY Power Relay.
Standard multiple operating modes and multiple time ranges.
Conforms to EN 61812-1 and IEC 60664-1 for Low Voltage,
and EMC Directives.
Ordering Information
List of Models
Note: Sockets and Hold-down Clips are not included with the H3YN. They must be ordered separately.
*1. Use the H3YN-4 or H3YN-41 Series when switching micro loads, and use the H3YN-4-Z or H3YN-41-Z Series when switching even smaller
loads.
*2. Only models with 24 VDC power supply are available.
Accessories (Order Separately)
Adapter, Mounting Plate, Hold-down Clips
Note: For details, refer to Precautions for H3Y-series Timers on page 31.
Socket
Note: 1. Cannot be used with the H3Y-@-0 (PCB terminals).
2. The PYF@@A-E has a finger-protection structure. Round crimp terminals cannot be used. Use forked crimp terminals.
3. For details, refer to Precautions for H3Y-series Timers on page 31.
For the most recent information on models that have been certified for
safety standards, refer to your OMRON website.
LR
Refer to Safety Precautions on page 36.
Supply voltage Time-limit contact Short-time range model
(0.1 s to 10 min)
Long-time range model
(0.1 min to 10 h)
24, 100 to 120, 200 to 230 VAC;
12, 24, 48, 100 to 110, 125 VDC
DPDT H3YN-2 H3YN-21
4PDT H3YN-4 *1H3YN-41 *1
24 VDC 4PDT (Twin contacts) H3YN-4-Z *1, *2H3YN-41-Z *1, *2
Name/specification Model
Flush mounting adapter Y92F-78
Mounting Plate for Socket For 1 Socket PYP-1
For 18 Sockets PYP-18
Hold-down Clips For PYF@A Y92H-3
For PY@ and PYF@M Y92H-4
Timer Square Sockets
Contact Model Pin
Connection
Terminal Model
DPDT H3YN-2@8-pin
Front Connecting
DIN track mounting PYF08A
DIN track mounting
(Finger Protection Structure) PYF08A-E
Screw mounting PYF08M
Back Connecting Solder terminal PY08
PCB terminal PY08-02
4PDT H3YN-4@14-pin
Front Connecting
DIN track mounting PYF14A
DIN track mounting
(Finger Protection Structure) PYF14A-E
Back Connecting Solder terminal PY14
PCB terminal PY14-02
H3YN
10
Specifications
Ratings
*1. Do not use the output from an inverter as the power supply. Refer to Safety Precautions for All Timers for details on your OMRON website.
*2. Single-phase, full-wave-rectified power supplies can be used.
*3. When using the H3YN continuously in any place where the ambient temperature is in a range of 45°C to 50°C, supply 90% to 110% of the
rated supply voltages (supply 95% to 110% with 12 VDC type).
*4. Set the reset voltage as follows to ensure proper resetting.
100 to 120 VAC: 10 VAC max.
200 to 230 VAC: 20 VAC max.
100 to 110 VDC: 10 VDC max.
*5. Refer to Safety Precautions for All Timers on your OMRON website when combining the Timer with an AC 2-wire proximity sensor.
*6. A diode to prevent reverse voltages is provided only on models with a DC power supply.
Item H3YN-2/-4/-4-Z H3YN-21/-41/-41-Z
Time ranges 0.1 s to 10 min (1 s, 10 s, 1 min, or 10 min max.
selectable)
0.1 min to 10 h (1 min, 10 min, 1 h, or 10 h max.
selectable)
Rated supply voltage *5, *624, 100 to 120, 200 to 230 VAC (50/60 Hz) *1
12, 24, 48, 100 to 110, 125 VDC *2
Pin type Plug-in
Operating mode ON-delay, interval, flicker OFF start, or flicker ON start (selectable with DIP switch)
Operating voltage range 85% to 110% of rated supply voltage (12 VDC: 90% to 110% of rated supply voltage) *3
Reset voltage 10% min. of rated supply voltage *4
Power consumption
100 to 120 VAC: Relay ON: Approx. 1.8 VA (1.6 W) at 120 VAC, 60 Hz
Relay OFF: Approx. 1 VA (0.6 W) at 120 VAC, 60 Hz
200 to 230 VAC: Relay ON: Approx. 2.2 VA (1.8 W) at 230 VAC, 60 Hz
Relay OFF: Approx. 1.5 VA (1.1 W) at 230 VAC, 60 Hz
24 VAC: Relay ON: Approx. 1.8 VA (1.4 W) at 24 VAC, 60 Hz
Relay OFF: Approx. 0.3 VA (0.2 W) at 24 VAC, 60 Hz
12 VDC: Relay ON: Approx. 1.1 W at 12 VDC
Relay OFF: Approx. 0.1 W at 12 VDC
24 VDC: Relay ON: Approx. 1.1 W at 24 VDC
Relay OFF: Approx. 0.1 W at 24 VDC
48 VDC: Relay ON: Approx. 1.2 W at 48 VDC
Relay OFF: Approx. 0.3 W at 48 VDC
100 to 110 VDC: Relay ON: Approx. 1.6 W at 110 VDC
Relay OFF: Approx. 0.4 W at 110 VDC
125 VDC: Relay ON: Approx. 1.6 W at 125 VDC
Relay OFF: Approx. 0.4 W at 125 VDC
Control outputs
DPDT:
5 A at 250 VAC, resistive load (cosφ = 1)
The minimum applicable load is 1 mA at 5 VDC (P reference value).
Contact materials: Ag
4PDT:
3 A at 250 VAC, resistive load (cosφ = 1)
H3YN-4/-41 series: The minimum applicable load is 1 mA at 1 VDC (P reference value).
H3YN-4-Z/-41-Z series: The minimum applicable load is 1 mA at 1 VDC (P reference value).
Contact materials: Au-clad + Ag-alloy
Ambient operating temperature -10°C to 50°C (with no icing)
Storage temperature -25°C to 65°C
Ambient operating humidity 35% to 85%
H3YN
11
Characteristics
*1. Terminal screw sections are excluded.
*2. The destructive shock resistance test was performed on the Timer.
*3. Refer to the Life-test Curve.
*4. Overvoltage category II.
*5. CCC certification requirements
Item H3YN-2/-21/-4/-41
Accuracy of operating time ±1% FS max. (1 s range: ±1%±10 ms max.)
Setting error ±10%±50 ms FS max.
Reset time Min. power-opening time: 0.1 s max. (including halfway reset)
Influence of voltage ±2% FS max.
Influence of temperature ±2% FS max.
Insulation resistance 100 MΩ min. (at 500 VDC)
Dielectric strength
2,000 VAC, 50/60 Hz for 1 min
(between current-carrying terminals and exposed non-current-carrying metal parts) *1
2,000 VAC, 50/60 Hz for 1 min (between operating power circuit and control output)
2,000 VAC, 50/60 Hz for 1 min (between different pole contacts; 2-pole model)
1,500 VAC, 50/60 Hz for 1 min (between different pole contacts; 4-pole model)
1,000 VAC, 50/60 Hz for 1 min (between non-continuous contacts)
Vibration resistance Destruction: 10 to 55 Hz, 0.75-mm single amplitude for 1 h each in 3 directions
Malfunction: 10 to 55 Hz, 0.5-mm single amplitude for 10 min each in 3 directions
Shock resistance Destruction: 1,000 m/s2 *2
Malfunction: 100 m/s2
Life expectancy
Mechanical: 10,000,000 operations min. (under no load at 1,800 operations/h)
Electrical: DPDT:
500,000 operations min. (5 A at 250 VAC, resistive load at 1,800 operations/h)
4PDT:
200,000 operations min. (H3YN-4-Z/-41-Z: 100,000 operations min.)
(3 A at 250 VAC, resistive load at 1,800 operations/h) *3
Impulse withstand voltage
Between power terminals:
3 kV for 100 to 120 VAC, 200 to 230 VAC, 100 to 110 VDC, 125 VDC
1 kV for 12 VDC, 24 VDC, 48 VDC, 24 VAC
Between exposed non-current-carrying metal parts:
4.5 kV for 100 to 120 VAC, 200 to 230 VAC, 100 to 110 VDC, 125 VDC
1.5 kV for 12 VDC, 24 VDC, 48 VDC, 24 VAC
Noise immunity ±1.5 kV, square-wave noise by noise simulator (pulse width: 100 ns/1 μs, 1-ns rise)
Static immunity Destruction: 8 kV
Malfunction: 4 kV
Degree of protection IP40
Weight Approx. 50 g
EMC
(EMI) EN 61812-1
Emission Enclosure: EN 55011 Group 1 class A
Emission AC Mains: EN 5CCC: GB/T 14048.5 5011 Group 1 class A
(EMS) EN 61812-1
Immunity ESD: IEC 61000-4-2
Immunity RF-interference: IEC 61000-4-3
Immunity Burst: IEC 61000-4-4
Immunity Surge: IEC 61000-4-5
Immunity Conducted Disturbance: IEC 61000-4-6
Immunity Voltage Dip/Interruption: IEC 61000-4-11
Approved standards
UL 508, CSA C22.2 No. 14, Lloyds, CCC: GB/T 14048.5 *5
Conforms to EN 61812-1 and IEC 60664-1. (2.5 kV/2 for H3YN-2/-21, 2.5 kV/1 for H3YN-4/-41,
H3YN-4-Z/-41-Z) *4
Model H3YN-2/-21 H3YN-4/-41
Recommended fuse RT14-20/6A (380 VAC 6 A),
manufactured by DELIXI RT14-20/4A (380 VAC 4 A), manufactured by DELIXI
Rated operating voltage Ue
Rated operating current Ie
AC-15: Ue: 250 VAC, Ie: 3 A
AC-13: Ue: 250 VAC, Ie: 5 A
DC-13: Ue: 30 VDC, Ie: 0.5 A
AC-15: Ue: 250 VAC, Ie: 2 A
AC-13: Ue: 250 VAC, Ie: 3 A
DC-13: Ue: 30 VDC, Ie: 0.5 A
Rated insulation voltage 250 V
Rated impulse withstand voltage
(altitude: 2,000 m max.) 2.5 kV (at 240 VAC)
Conditional short-circuit current 1000 A
H3YN
12
Life-test Curve (Reference Value)
500
100
50
20
500
100
50
20
500
100
50
20
500
100
50
20
500
100
50
10
6
H3YN-2/-21
H3YN-4/-41
H3YN-4-Z/-41-Z
Switching operations (x 104)
Load current (A)
Switching operations (x 104)
Load current (A)
Switching operations (x 104)
Load current (A)
Switching operations (x 104)
Load current (A)
Switching operations (x 104)
Load current (A)
250 VAC, resistive load
250 VAC, cosφ = 1
24 VDC, cosφ = 1
Reference: A maximum current of 0.6 A can be switched at 125 VDC (cosφ = 1).
Maximum current of 0.2 A can be switched if L/R is 7 ms. In both cases, a
life of 100,000 operations can be expected.
The minimum applicable load is 1 mA at 5 VDC (P reference value)
250 VAC, cosφ = 0.4
24 VDC, L/R = 7 ms
250 VAC, cosφ = 1
24 VDC, cosφ = 1
Reference: A maximum current of 0.5 A can be switched at 125 VDC (cosφ = 1).
Maximum current of 0.2 A can be switched if L/R is 7 ms. In both cases, a
life of 100,000 operations can be expected.
The minimum applicable load is 1 mA at 1 VDC (P reference value)
250 VAC, cosφ = 0.4
24 VDC, L/R = 7 ms
24 VDC,
resistive load
Reference: A maximum current of 0.5 A can be switched at 125 VDC (cosφ = 1).
Maximum current of 0.2 A can be switched if L/R is 7 ms. In both cases, a
life of 100,000 operations can be expected.
The minimum applicable load is 0.1 mA at 1 VDC (P reference value
H3YN
13
Connections
Connection
Pulse Operation
A pulse output for a certain period can be obtained with a random external input signal.
Use the H3YN in interval mode as shown in the following timing charts.
Mode Terminals
Pulse operation
Power supply between 9 and 14
Short-circuit between 5 and 13
Input signal between 9 and 13
Operating mode; interval and all other modes Power supply between 13 and 14
UP PW
H3YN-2/-21
DIN Indication DIN Indication
UP PW
Timer
circuit
Timer
circuit
H3YN-4/-41
H3YN-4-Z/-41-Z
(Bottom View) (Bottom View)
H3YN-2/-21
External input
Power (9-14)
Power (9-14)
External input
H3YN-4/-41
H3YN-4-Z/-41-Z
Timer
circuit
Timer
circuit
External short circuit
(5-13)
External input
(9-13)
Time limit contact
NO (12-8)
Time limit contact
NC (12-4)
Run/Power indicator
(PW)
Output indicator (UP)
50 ms
min.
Note: t: Set time
Rt: Reset time
External short circuit
(5-13)
External input
(9-13)
Time limit contact NO
(10-6, 11-7, 12-8)
Time limit contact NC
(10-2, 11-3, 12-4)
Run/Power indicator
(PW)
Output indicator (UP)
50 ms
min.
Note: t: Set time
Rt: Reset time
!Caution
Be careful when connecting wires.
H3YN
14
Nomenclature
Dimensions (Unit: mm)
Timers
Run/Power Indicator (Green)
(Lit: Power ON)
Output Indicator (Orange)
(Lit: Output ON)
Main Dial
Set the desired time according
to time range selectable by
DIP switch.
6.4
(63.0)
H3YN-2/-21 Front Mounting
Fourteen, 3 × 1.2 elliptic holes
28 max.
21.5 max.
28 max.
21.5 max.
Eight, 3 × 1.2 elliptic holes
H3YN-4/-41 Front Mounting
H3YN-4-Z/-41-Z
Mounting Holes
Eight,
1.3-dia. holes
Pin 1
Mounting Holes
Fourteen,
1.3-dia. holes
Pin 1
H3YN
15
Operation
DIP Switch Settings
The 1-s range and ON-delay mode for H3YN-2/-4/-4-Z, the 1-min range and ON-delay mode for H3YN-21/-41/-41-Z are factory-set before shipping.
Time Ranges
Note: The top two DIP switch pins are used to select the time ranges.
Operating Modes
Note: The bottom two DIP switch pins are used to select the operating mode.
Model Time range Time setting
range Setting Factory-set
H3YN-2,
H3YN-4
H3YN-4-Z
1 s 0.1 to 1 s Yes
10 s 1 to 10 s No
1 min 0.1 to 1 min No
10 min 1 to 10 min No
H3YN-21,
H3YN-41
H3YN-41-Z
1 min 0.1 to 1 min Yes
10 min 1 to 10 min No
1 h 0.1 to 1 h No
10 h 1 to 10 h No
Operating mode Setting Factory-set
ON-delay Yes
Interval No
Flicker OFF-start No
Flicker ON-start No
H3YN
16
Timing Chart
Note: t: Set time
Rt: Reset time
Operating mode Timing chart
H3YN-2/-21 H3YN-4/-41
ON-delay
Power
Output
Power (13-14)
Time limit contact
NC (9-1, 12-4)
Time limit contact
NO (9-5, 12-8)
Run/Power indicator
(PW)
Output indicator
Power (13-14)
Time limit contact
NC (9-1, 10-2, 11-3,
12-4)
Time limit contact
NO (9-5, 10-6, 11-7,
12-8)
Run/Power indicator
(PW)
Output indicator
(UP)
Interval
Power
Output
Power (13-14)
Time limit contact
NC (9-1, 12-4)
Time limit contact
NO (9-5, 12-8)
Run/Power
indicator (PW)
Output indicator
(UP)
Power (13-14)
Time limit contact
NC (9-1, 10-2, 11-3,
12-4)
Time limit contact
NO (9-5, 10-6, 11-7,
12-8)
Run/Power
indicator (PW)
Output indicator
(UP)
Flicker OFF-start
Power
Output
Power (13-14)
Time limit contact
NC (9-1, 12-4)
Time limit contact
NO (9-5, 12-8)
Run/Power indicator
(PW)
Output indicator
(UP)
Power (13-14)
Time limit contact
NC (9-1, 10-2, 11-3,
12-4)
Time limit contact
NO (9-5, 10-6, 11-7,
12-8)
Run/Power indicator
(PW)
Output indicator
(UP)
Flicker ON-start
Power
Output
Power (13-14)
Time limit contact
NC (9-1, 12-4)
Time limit contact
NO (9-5, 12-8)
Run/Power
indicator (PW)
Output indicator
(UP)
Power (13-14)
Time limit contact
NC (9-1, 10-2, 11-3,
12-4)
Time limit contact
NO (9-5, 10-6, 11-7,
12-8)
Run/Power
indicator (PW)
Output indicator
(UP)
17
Solid-state Timer
H3Y-@-B
Miniature Timer Compatible with the MY
Relay
UL listed when used with a Push-In Plus Terminal Block Socket. *
Conforms to CSA, CE Marking, CCC and LR.
Black design with power supply terminals on top and contact output
terminals on bottom.
Large transparent time setting knob facilitates time setting.
A flat-blade and Phillips screwdriver can also be used for time setting.
Semi-multi power supply voltage.
*When used in combination with a Push-In Plus Terminal Block Socket (PYF-@-PU-L).
Ordering Information
Note: Sockets and Hold-down Clips are not included with the H3Y-B. They must be ordered separately.
*Use the H3Y-4-B Series when switching micro loads.
Accessories (Order Separately)
Hold-down Clips
Note: For details, refer to Precautions for H3Y-series Timers on page 31.
Socket
Note: 1. Cannot be used with the H3Y-@-0 (PCB terminals).
2. For details, refer to Precautions for H3Y-series Timers on page 31.
Operation/resetting
system Time-limit contact Time ranges Supply voltage
Mounting
Surface/DIN-track mounting
(with socket)
Time-limit operation/
self-resetting
DPDT
(for power switching) 0.04 s to 3 h
100 to 120,
200 to 230 VAC (50/60 Hz);
12, 24, 48, 100 to 110 VDC
H3Y-2-B
4PDT H3Y-4-B *
Name/specification Model
Hold-down Clips For PYF-@-PU-L Y92H-3
For the most recent information on models that
have been certified for safety standards, refer to
your OMRON website.
LR
Refer to Safety Precautions on page 36.
Timer Square Sockets
Contact Model Pin Connection Terminal Model Terminal Type
DPDT H3Y-2-B 8-pin Front Connecting DIN track mounting PYF-08-PU-L Push-In Plus Terminal Block
4PDT H3Y-4-B 14-pin Front Connecting DIN track mounting PYF-14-PU-L Push-In Plus Terminal Block
H3Y-@-B
18
Specifications
Time Ranges
Ratings
*1. Do not use the output from an inverter as the power supply. Refer to Safety Precautions for All Timers for details on your OMRON website.
*2. With DC ratings, single-phase full-wave rectified power sources may be used.
*3. Only the H3Y-2-B Series include 12 VDC models.
*4. Use the Timer within 90% to 110% of the rated supply voltage (95% to 110% for 12 VDC) when using it continuously under an ambient
operating temperature of 50°C.
*5. Set the reset voltage as follows to ensure proper resetting.
100 to 120 VAC: 10 VAC max.
200 to 230 VAC: 20 VAC max.
100 to 110 VDC: 10 VDC max.
*6. Refer to Safety Precautions for All Timers on your OMRON website when combining the Timer with an AC 2-wire proximity sensor.
*7. A diode to prevent reverse voltages is provided only on models with a DC power supply.
Rated time Time setting range Rated time Time setting range
0.5 s 0.04 to 0.5 s 3 min 0.1 to 3 min
1 s 0.1 to 1 s 5 min 0.2 to 5 min
5 s 0.2 to 5 s 10 min 0.5 to 10 min
10 s 0.5 to 10 s 30 min 1 to 30 min
30 s 1.0 to 30 s 60 min 2 to 60 min
60 s 2.0 to 60 s 3 h 0.1 to 3 h
120 s 5.0 to 120 s --- ---
Item H3Y-2-B/H3Y-4-B
Rated supply voltage *6, *7100 to 120 (50/60 Hz), 200 to 230 VAC (50/60 Hz), 24 VAC (50/60 Hz) *1
12, 24, 48, 125, 100 to 110 VDC *2, *3
Operating voltage range All rated voltages except 12 VDC: 85% to 110% of rated supply voltage
12 VDC: 90% to 110% of rated supply voltage *4
Reset voltage 10% min. of rated supply voltage *5
Power consumption
100 to 120 VAC: 1.5 VA (at 120 VAC)
200 to 230 VAC: 1.8 VA (at 230 VAC)
24 VAC: 1.5 VA (at 24 VAC)
12 VDC: 0.9 W (at 12 VDC)
24 VDC: 0.9 W (at 24 VDC)
48 VDC: 1.0 W (at 48 VDC)
100 to 110 VDC: 1.3 W (at 110 VDC)
125 VDC: 1.3 W (at 125 VDC)
Control outputs
H3Y-2-B:
5 A at 250 VAC, resistive load (cosφ = 1)
The minimum applicable load is 1 mA at 5 VDC (P reference value).
Contact materials: Ag
H3Y-4-B:
3 A at 250 VAC, resistive load (cosφ = 1)
The minimum applicable load is 1 mA at 1 VDC (P reference value).
Contact materials: Au-clad + Ag-alloy
Ambient operating temperature -10°C to 55°C (with no icing)
Storage temperature -25°C to 65°C
Ambient operating humidity 35% to 85%
H3Y-@-B
19
Characteristics
*1. Add ±10 mS to the above value for the 0.5-S range model.
*2. Terminal screw sections are excluded.
*3. The destructive shock resistance test was performed on the Timer.
*4. Check the electrical life curve.
*5. cULus listing applies when the OMRON PYF-@-PU-L is used.
cURus recognition applies when any other socket is used.
*6. Overvoltage category II.
*7. CCC certification requirements
Accuracy of operating time ±1% FS max. (0.5 s range: ±1%±10 ms max.) *1
Setting error ±10%±50 ms FS max.
Reset time Min. power-opening time: 0.1 s max. (including halfway reset)
Influence of voltage ±2% FS max. *1
Influence of temperature ±2% FS max. *1
Insulation resistance 100 MΩ min. (at 500 VDC)
Dielectric strength
2,000 VAC, 50/60 Hz for 1 min
(between current-carrying terminals and exposed non-current-carrying metal parts) *2
2,000 VAC, 50/60 Hz for 1 min (between operating power circuit and control output) *2
2,000 VAC, 50/60 Hz for 1 min (between different pole contacts; 2-pole model) *2
1,500 VAC, 50/60 Hz for 1 min (between different pole contacts; 4-pole model)
1,000 VAC, 50/60 Hz for 1 min (between non-continuous contacts)
Impulse withstand voltage
Between power terminals:
3 kV for 100 to 120 VAC, 200 to 230 VAC, 100 to 110 VDC, 125 VDC
1 kV for 12 VDC, 24 VDC, 48 VDC
Between exposed non-current-carrying metal parts:
4.5 kV for 100 to 120 VAC, 200 to 230 VAC, 100 to 110 VDC, 125 VDC
1.5 kV for 12 VDC, 24 VDC, 48 VDC
Noise immunity ±1.5 kV, square-wave noise by noise simulator (pulse width: 100 ns/1 μs, 1-ns rise)
Static immunity Destruction: 8 kV
Malfunction: 4 kV
Vibration resistance Destruction: 10 to 55 Hz, 0.75-mm single amplitude
Malfunction: 10 to 55 Hz, 0.5-mm single amplitude
Shock resistance Destruction: 1,000 m/s2 (approx. 100G) *3
Malfunction: 100 m/s2 (approx. 10G)
Life expectancy
Mechanical:10,000,000 operations min. (under no load at 1,800 operations/h)
Electrical:
H3Y-2-B: 500,000 operations min. (5 A at 250 VAC, resistive load at 1800 operations/h)
H3Y-4-B: 200,000 operations min. (3 A at 250 VAC, resistive load at 1800 operations/h) *4
Enclosure rating IP40
Weight Approx. 50 g
EMC
(EMI) EN 61812-1
Emission Enclosure: EN 55011 Group 1 class A
Emission AC Mains: EN 55011 Group 1 class A
(EMS) EN 61812-1
Immunity ESD: IEC 61000-4-2
Immunity RF-interference: IEC 61000-4-3
Immunity Burst: IEC 61000-4-4
Immunity Surge: IEC 61000-4-5
Immunity Conducted Disturbance: IEC 61000-4-6
Immunity Voltage Dip/Interruption: IEC 61000-4-11
Approved standards UL 508/CSA C22.2 No.14 *5, CSA C22.2 No.14, Lloyds, CCC: GB/T 14048.5 *7
Conforms to EN 61812-1 and IEC 60664-1. (2.5 kV/2 for H3Y-2-B *6, 2.5 kV/1 for H3Y-4-B *6)
Model H3Y-2-B H3Y-4-B
Recommended fuse RT14-20/6A (380 VAC 6 A), manufactured by
DELIXI
RT14-20/4A (380 VAC 4 A), manufactured by
DELIXI
Rated operating voltage Ue
Rated operating current Ie
AC-15: Ue: 250 VAC, Ie: 3 A
AC-13: Ue: 250 VAC, Ie: 5 A
DC-13: Ue: 30 VDC, Ie: 0.5 A
AC-15: Ue: 250 VAC, Ie: 2 A
AC-13: Ue: 250 VAC, Ie: 3 A
DC-13: Ue: 30 VDC, Ie: 0.5 A
Rated insulation voltage 250 V
Rated impulse withstand voltage
(altitude: 2,000 m max.) 2.5 kV (at 240 VAC)
Conditional short-circuit current 1000 A
H3Y-@-B
20
Engineering Data
Connections
Connections
H3Y-2-B
Switching operations (×104)
Load current (A)
H3Y-2-B
H3Y-4-B
Load current (A)
Load current (A)
H3Y-4-B
Load current (A)
Reference: A maximum current of 0.6 A can be switched at 125 VDC (cosφ = 1).
Maximum current of 0.2 A can be switched if L/R is 7 ms. In both
cases, a life of 100,000 operations can be expected.The minimum
applicable load is 1 mA at 5 VDC (P reference value).
Reference: A maximum current of 0.5 A can be switched at 125 VDC (cosφ = 1).
Maximum current of 0.2 A can be switched if L/R is 7 ms. In both
cases, a life of 100,000 operations can be expected.The minimum
applicable load is 1 mA at 1 VDC (P reference value).
Switching operations (×104)
Switching operations (×104)
Switching operations (×104)
250 VAC, cosφ = 0.4
24 VDC, L/R = 7 ms
250 VAC, cosφ = 1
24 VDC, cosφ = 1
250 VAC, cosφ = 1
24 VDC, cosφ = 1
250 VAC, cosφ = 0.4
24 VDC, L/R = 7 ms
500
100
50
20
500
100
50
20
500
100
50
20
500
100
50
20
H3Y-2-B H3Y-4-B
Connect the DC power supply to
terminals A1(13) and A2(14)
according to the polarity marks.
Connect the DC power supply to
terminals A1(13) and A2(14)
according to the polarity marks.
(Bottom View) (Bottom View)
(DIN notation) (DIN notation)
A2
(14)
11
(9)
41
(12)
A1
(13) 44
(8)
12
(1)
14
(5)
42
(4)
PW UP
A2
(14)
41
(12)
A1
(13)
11
(9)
44
(8)
14
(5)
12
(1)
42
(4)
Timer
circuit A2
(14)
UP
PW
44
(8)
41
(12)
42
(4)
34
(7)
31
(11)
32
(3)
24
(6)
21
(10)
22
(2)
12
(1)
11
(9)
A2
(14)
A1
(13)
21
(10)
31
(11)
41
(12)
14
(5)
22
(2)
24
(6)
32
(3)
34
(7)
42
(4)
44
(8)
14
(5)
11
(9)
12
(1)
A1
(13)
Timer
circuit
H3Y-@-B
21
Operation
Timing Chart
Nomenclature
H3Y-2-B H3Y-4-B
Note: t = Set time
Rt = Reset time
Note: t = Set time
Rt = Reset time
Power (A1(13)-A2(14))
Power indicator (PW)
Time-up indicator (UP)
Time limit contact
NC (11(9)-12(1), 41(12)-42(4))
Time limit contact
NO (11(9)-14(5), 41(12)-44(8))
Power (A1(13)-A2(14))
Power indicator (PW)
Time-up indicator (UP)
Time limit contact
NC(11(9)-12(1), 21(10)-22(2),
31(11)-32(3), 41(12)-42(4))
Time limit contact
NO(11(9)-14(5), 21(10)-24(6),
31(11)-34(7), 41(12)-44(8))
Run/Power Indicator (Green)
(Lit: Power ON)
Output Indicator (Orange)
(Lit: Output ON)
Main Dial
H3Y-@-B
22
Dimensions (Unit: mm)
Timers
4 52.6
(63.0)
6.4 21.5 max.
28 max.
0.5
H3Y-2-B
0.5
28 max.
4 52.6
(63.0)
6.4 21.5 max.
H3Y-4-B
23
Solid-state Timer
H3YN-@-B
Miniature Timer with Multiple Time Ranges
and Multiple Operating Modes
UL listed when used with a Push-In Plus Terminal Block Socket. *
Conforms to CSA, CE Marking, LR, and CCC.
Black design with power supply terminals on top and contact output
terminals on bottom.
Standard multiple operating modes and multiple time ranges.
Pin configuration compatible with MY Power Relay.
Minimizes stock.
*When used in combination with a Push-In Plus Terminal Block Socket
(PYF-@-PU-L).
Ordering Information
List of Models
Note: 1. Sockets and Hold-down Clips are not included with the H3YN-B. They must be ordered separately.
*1. Use the H3YN-4-B or H3YN-41-B Series when switching micro loads, and use the H3YN-4-Z-B or H3YN-41-Z-B Series when switching even
smaller loads.
*2. Only models with 24 VDC power supply are available.
Accessories (Order Separately)
Hold-down Clips
Note: For details, refer to Precautions for H3Y-series Timers on page 31.
Socket
Note: 1. Cannot be used with the H3YN-@-0 (PCB terminals).
2. For details, refer to Precautions for H3Y-series Timers on page 31.
For the most recent information on models that
have been certified for safety standards, refer to
your OMRON website.
LR
Refer to Safety Precautions on page 36.
Supply voltage Time-limit contact Short-time range model
(0.1 s to 10 min)
Long-time range model
(0.1 min to 10 h)
24, 100 to 120, 200 to 230 VAC;
12, 24, 48, 100 to 110, 125 VDC
DPDT H3YN-2-B H3YN-21-B
4PDT H3YN-4-B *1H3YN-41-B *1
24 VDC 4PDT (Twin contacts) H3YN-4-Z-B *1, *2H3YN-41-Z-B *1, *2
Name/specification Model
Hold-down Clips For PYF-@-PU-L Y92H-3
Timer Square Sockets
Contact Model Pin Connection Terminal Model Terminal Type
DPDT
H3YN-2
@
-B 8-pin Front Connecting DIN track mounting PYF-08-PU-L Push-In Plus Terminal Block
4PDT
H3YN-4
@
-B 14-pin Front Connecting DIN track mounting PYF-14-PU-L Push-In Plus Terminal Block
H3YN-@-B
24
Specifications
Ratings
*1. Do not use the output from an inverter as the power supply. Refer to Safety Precautions for All Timers for details on your OMRON website.
*2. Single-phase, full-wave-rectified power supplies can be used.
*3. When using the H3YN-B continuously in any place where the ambient temperature is in a range of 45°C to 50°C, supply 90% to 110% of the
rated supply voltages (supply 95% to 110% with 12 VDC type).
*4. Set the reset voltage as follows to ensure proper resetting.
100 to 120 VAC: 10 VAC max.
200 to 230 VAC: 20 VAC max.
100 to 110 VDC: 10 VDC max.
*5. Refer to Safety Precautions for All Timers on your OMRON website when combining the Timer with an AC 2-wire proximity sensor.
*6. A diode to prevent reverse voltages is provided only on models with a DC power supply.
Item H3YN-2-B/-4-B/-4-Z-B H3YN-21-B/-41-B/-41-Z-B
Time ranges 0.1 s to 10 min (1 s, 10 s, 1 min, or 10 min max.
selectable)
0.1 min to 10 h (1 min, 10 min, 1 h, or 10 h max.
selectable)
Rated supply voltage *5, *624, 100 to 120, 200 to 230 VAC (50/60 Hz) *1
12, 24, 48, 100 to 110, 125 VDC *2
Pin type Plug-in
Operating mode ON-delay, interval, flicker OFF start, or flicker ON start (selectable with DIP switch)
Operating voltage range 85% to 110% of rated supply voltage (12 VDC: 90% to 110% of rated supply voltage) *3
Reset voltage 10% min. of rated supply voltage *4
Power consumption
100 to 120 VAC: Relay ON: Approx. 1.8 VA (1.6 W) at 120 VAC, 60 Hz
Relay OFF: Approx. 1 VA (0.6 W) at 120 VAC, 60 Hz
200 to 230 VAC: Relay ON: Approx. 2.2 VA (1.8 W) at 230 VAC, 60 Hz
Relay OFF: Approx. 1.5 VA (1.1 W) at 230 VAC, 60 Hz
24 VAC: Relay ON: Approx. 1.8 VA (1.4 W) at 24 VAC, 60 Hz
Relay OFF: Approx. 0.3 VA (0.2 W) at 24 VAC, 60 Hz
12 VDC: Relay ON: Approx. 1.1 W at 12 VDC
Relay OFF: Approx. 0.1 W at 12 VDC
24 VDC: Relay ON: Approx. 1.1 W at 24 VDC
Relay OFF: Approx. 0.1 W at 24 VDC
48 VDC: Relay ON: Approx. 1.2 W at 48 VDC
Relay OFF: Approx. 0.3 W at 48 VDC
100 to 110 VDC: Relay ON: Approx. 1.6 W at 110 VDC
Relay OFF: Approx. 0.4 W at 110 VDC
125 VDC: Relay ON: Approx. 1.6 W at 125 VDC
Relay OFF: Approx. 0.4 W at 125 VDC
Control outputs
DPDT:
5 A at 250 VAC, resistive load (cosφ = 1)
The minimum applicable load is 1 mA at 5 VDC (P reference value).
Contact materials: Ag
4PDT:
3 A at 250 VAC, resistive load (cosφ = 1)
H3YN-4-B/-41-B series: The minimum applicable load is 1 mA at 1 VDC (P reference value).
H3YN-4-Z-B/-41-Z-B series: The minimum applicable load is 1 mA at 1 VDC (P reference value).
Contact materials: Au-clad + Ag-alloy
Ambient operating temperature -10°C to 55°C (with no icing)
Storage temperature -25°C to 65°C
Ambient operating humidity 35% to 85%
H3YN-@-B
25
Characteristics
*1. Terminal screw sections are excluded.
*2. Refer to the Life-test Curve.
*3. cULus listing applies when the OMRON PYF-@-PU-L is used.
cURus recognition applies when any other socket is used.
*4. Overvoltage category II
*5. CCC certification requirements
Item H3YN-2-B/-21-B/-4-B/-41-B
Accuracy of operating time ±1% FS max. (1 s range: ±1%±10 ms max.)
Setting error ±10%±50 ms FS max.
Reset time Min. power-opening time: 0.1 s max. (including halfway reset)
Influence of voltage ±2% FS max.
Influence of temperature ±2% FS max.
Insulation resistance 100 MΩ min. (at 500 VDC)
Dielectric strength
2,000 VAC, 50/60 Hz for 1 min
(between current-carrying terminals and exposed non-current-carrying metal parts) *1
2,000 VAC, 50/60 Hz for 1 min (between operating power circuit and control output)
2,000 VAC, 50/60 Hz for 1 min (between different pole contacts; 2-pole model)
1,500 VAC, 50/60 Hz for 1 min (between different pole contacts; 4-pole model)
1,000 VAC, 50/60 Hz for 1 min (between non-continuous contacts)
Vibration resistance Destruction: 10 to 55 Hz, 0.75-mm single amplitude for 1 h each in 3 directions
Malfunction: 10 to 55 Hz, 0.5-mm single amplitude for 10 min each in 3 directions
Shock resistance Destruction: 1,000 m/s2
Malfunction: 100 m/s2
Life expectancy
Mechanical: 10,000,000 operations min. (under no load at 1,800 operations/h)
Electrical: DPDT:
500,000 operations min. (5 A at 250 VAC, resistive load at 1,800 operations/h)
4PDT:
200,000 operations min. (H3YN-4-Z/-41-Z: 100,000 operations min.)
(3 A at 250 VAC, resistive load at 1,800 operations/h) *2
Impulse withstand voltage
Between power terminals:
3 kV for 100 to 120 VAC, 200 to 230 VAC, 100 to 110 VDC, 125 VDC
1 kV for 12 VDC, 24 VDC, 48 VDC, 24 VAC
Between exposed non-current-carrying metal parts:
4.5 kV for 100 to 120 VAC, 200 to 230 VAC, 100 to 110 VDC, 125 VDC
1.5 kV for 12 VDC, 24 VDC, 48 VDC, 24 VAC
Noise immunity ±1.5 kV, square-wave noise by noise simulator (pulse width: 100 ns/1 μs, 1-ns rise)
Static immunity Destruction: 8 kV
Malfunction: 4 kV
Degree of protection IP40
Weight Approx. 50 g
EMC
(EMI) EN 61812-1
Emission Enclosure: EN 55011 Group 1 class A
Emission AC Mains: EN 55011 Group 1 class A
(EMS) EN 61812-1
Immunity ESD: IEC 61000-4-2
Immunity RF-interference: IEC 61000-4-3
Immunity Burst: IEC 61000-4-4
Immunity Surge: IEC 61000-4-5
Immunity Conducted Disturbance: IEC 61000-4-6
Immunity Voltage Dip/Interruption: IEC 61000-4-11
Approved standards
cULus (or cURus): UL 508/CSA C22.2 No.14 *3, CSA C22.2 No.14, Lloyds, CCC: GB/T 14048.5 *5
Conforms to EN 61812-1 and IEC 60664-1. (2.5 kV/2 for H3YN-2-B/-21-B *4,
2.5 kV/1 for H3YN-4-B/-41-B, H3YN-4-Z-B/-41-Z-B *4)
Model H3YN-2-B/21-B H3YN-4-B/41-B
Recommended fuse RT14-20/6A (380 VAC 6 A), manufactured by
DELIXI
RT14-20/4A (380 VAC 4 A), manufactured by
DELIXI
Rated operating voltage Ue
Rated operating current Ie
AC-15: Ue: 250 VAC, Ie: 3 A
AC-13: Ue: 250 VAC, Ie: 5 A
DC-13: Ue: 30 VDC, Ie: 0.5 A
AC-15: Ue: 250 VAC, Ie: 2 A
AC-13: Ue: 250 VAC, Ie: 3 A
DC-13: Ue: 30 VDC, Ie: 0.5 A
Rated insulation voltage 250 V
Rated impulse withstand voltage
(altitude: 2,000 m max.) 2.5 kV (at 240 VAC)
Conditional short-circuit current 1000 A
H3YN-@-B
26
Life-test Curve (Reference Value)
500
100
50
20
500
100
50
20
500
100
50
20
500
100
50
20
500
100
50
10
6
H3YN-2-B/-21-B
H3YN-4-B/-41-B
H3YN-4-Z-B/-41-Z-B
Switching operations (x 104)
Load current (A)
Switching operations (x 104)
Load current (A)
Switching operations (x 104)
Load current (A)
Switching operations (x 104)
Load current (A)
Switching operations (x 104)
Load current (A)
250 VAC, resistive load
250 VAC, cosφ = 1
24 VDC, cosφ = 1
Reference: A maximum current of 0.6 A can be switched at 125 VDC (cosφ = 1).
Maximum current of 0.2 A can be switched if L/R is 7 ms. In both cases, a
life of 100,000 operations can be expected.
The minimum applicable load is 1 mA at 5 VDC (P reference value)
250 VAC, cosφ = 0.4
24 VDC, L/R = 7 ms
250 VAC, cosφ = 1
24 VDC, cosφ = 1
Reference: A maximum current of 0.5 A can be switched at 125 VDC (cosφ = 1).
Maximum current of 0.2 A can be switched if L/R is 7 ms. In both cases, a
life of 100,000 operations can be expected.
The minimum applicable load is 1 mA at 1 VDC (P reference value)
250 VAC, cosφ = 0.4
24 VDC, L/R = 7 ms
24 VDC,
resistive load
Reference: A maximum current of 0.5 A can be switched at 125 VDC (cosφ = 1).
Maximum current of 0.2 A can be switched if L/R is 7 ms. In both cases, a
life of 100,000 operations can be expected.
The minimum applicable load is 0.1 mA at 1 VDC (P reference value
H3YN-@-B
27
Connections
Connection
Pulse Operation
A pulse output for a certain period can be obtained with a random external input signal.
Use the H3YN-B in interval mode as shown in the following timing charts.
Mode Terminals
Pulse operation
Power supply between 11(9) and A2(14)
Short-circuit between 14(5) and A1(13)
Input signal between 11(9) and A1(13)
Operating mode; interval and all other modes Power supply between A1(13) and A2(14)
H3YN-2-B/-21-B
(DIN Indication) (DIN Indication)
H3YN-4-B/-41-B
H3YN-4-Z-B/-41-Z-B
(Bottom View) (Bottom View)
12
(1)
11
(9)
A2
(14)
A1
(13)
41
(12)
14
(5)
42
(4)
44
(8)
A2
(14)
Timer
circuit
UP
PW
14
(5)
12
(1)
A1
(13)
44
(8)
41
(12)
11
(9)
42
(4)
A2
(14)
Timer
circuit
UP
PW
14
(5)
12
(1)
A1
(13)
44
(8)
41
(12)
11
(9)
42
(4)
34
(7)
31
(11)
32
(3)
24
(6)
21
(10)
22
(2)
12
(1)
11
(9)
A2
(14)
A1
(13)
21
(10)
31
(11)
41
(12)
14
(5)
22
(2)
24
(6)
32
(3)
34
(7)
42
(4)
44
(8)
H3YN-2-B/-21-B
Power (11(9)-A2(14))
Power (11(9)-A2(14))
H3YN-4-B/-41-B
H3YN-4-Z-B/-41-Z-B
External short circuit
(14(5)-A1(13))
External input
(11(9)-A1(13))
Time limit contact
NO (41(12)-44(8))
Time limit contact
NC (41(12)-42(4))
Run/Power indicator
(PW)
Output indicator (UP)
50 ms
min.
Note: t: Set time
Rt: Reset time
External short circuit
(14(5)-A1(13))
External input
(11(9)-A1(13))
Time limit contact NO
(21(10)-24(6),
31(11)-34(7), 41(12)-44(8))
Time limit contact NC
(21(10)-22(2),
31(11)-32(3), 41(12)-42(4))
Run/Power indicator
(PW)
Output indicator (UP)
50 ms
min.
Note: t: Set time
Rt: Reset time
A2
(14)
Timer
circuit
External input
UP
PW
14
(5)
12
(1)
A1
(13)
44
(8)
41
(12) 11
(9)
42
(4)
A2
(14)
Timer
circuit
External input
UP
PW
A1
(13)
( )
( )
14
(5)
12
(1)
44
(8)
41
(12)
11
(9)
42
(4)
34
(7)
31
(11)
32
(3)
24
(6)
21
(10)
22
(2)
!Caution
Be careful when connecting wires.
H3YN-@-B
28
Nomenclature
Dimensions (Unit: mm)
Timers
Run/Power Indicator (Green)
(Lit: Power ON)
Output Indicator (Orange)
(Lit: Output ON)
Main Dial
Set the desired time according
to time range selectable by
DIP switch.
(63.0)
(63.0)
H3YN-2-B/-21-B Front Mounting
H3YN-4-B/-41-B Front Mounting
H3YN-4-Z-B/-41-Z-B
0.5
0.5
4 52.6 6.4 21.5 max.
28 max.
4 52.6 6.4 21.5 max.
28 max.
H3YN-@-B
29
Operation
DIP Switch Settings
The 1-s range and ON-delay mode for H3YN-2-B/-4-B/-4-Z-B, the 1-min range and ON-delay mode for H3YN-21-B/-41-B/-41-Z-B are factory-set
before shipping.
Time Ranges
Note: The top two DIP switch pins are used to select the time ranges.
Operating Modes
Note: The bottom two DIP switch pins are used to select the operating mode.
Model Time range Time setting
range Setting Factory-set
H3YN-2-B,
H3YN-4-B
H3YN-4-Z-B
1 s 0.1 to 1 s Yes
10 s 1 to 10 s No
1 min 0.1 to 1 min No
10 min 1 to 10 min No
H3YN-21-B,
H3YN-41-B
H3YN-41-Z-B
1 min 0.1 to 1 min Yes
10 min 1 to 10 min No
1 h 0.1 to 1 h No
10 h 1 to 10 h No
Operating mode Setting Factory-set
ON-delay Yes
Interval No
Flicker OFF-start No
Flicker ON-start No
H3YN-@-B
30
Timing Chart
Note: t: Set time
Rt: Reset time
Operating mode Timing chart
H3YN-2-B/-21-B H3YN-4-B/-41-B
ON-delay
Power
Output
Power
(A1(13)-A2(14))
Time limit contact NC
(11(9)-12(1), 41(12)-42(4))
Time limit contact NO
(11(9)-14(5), 41(12)-44(8))
Run/Power indicator
(PW)
Output indicator
(UP)
Time limit contact NC
(11(9)-12(1), 21(10)-22(2),
31(11)-32(3), 41(12)-42(4))
Time limit contact NO
(11(9)-14(5), 21(10)-24(6),
31(11)-34(7), 41(12)-44(8))
Run/Power indicator
(PW)
Output indicator
(UP)
Power
(A1(13)-A2(14))
Interval
Power
Output
Power
(A1(13)-A2(14))
Time limit contact NC
(11(9)-12(1), 41(12)-42(4))
Time limit contact NO
(11(9)-14(5), 41(12)-44(8))
Run/Power indicator
(PW)
Output indicator
(UP)
Time limit contact NC
(11(9)-12(1), 21(10)-22(2),
31(11)-32(3), 41(12)-42(4))
Time limit contact NO
(11(9)-14(5), 21(10)-24(6),
31(11)-34(7), 41(12)-44(8))
Run/Power indicator
(PW)
Output indicator
(UP)
Power
(A1(13)-A2(14))
Flicker OFF-start
Power
Output
Power
(A1(13)-A2(14))
Time limit contact NC
(11(9)-12(1), 41(12)-42(4))
Time limit contact NO
(11(9)-14(5), 41(12)-44(8))
Run/Power indicator
(PW)
Output indicator
(UP)
Time limit contact NC
(11(9)-12(1), 21(10)-22(2),
31(11)-32(3), 41(12)-42(4))
Time limit contact NO
(11(9)-14(5), 21(10)-24(6),
31(11)-34(7), 41(12)-44(8))
Run/Power indicator
(PW)
Output indicator
(UP)
Power
(A1(13)-A2(14))
Flicker ON-start
Power
Output
Power
(A1(13)-A2(14))
Time limit contact NC
(11(9)-12(1), 41(12)-42(4))
Time limit contact NO
(11(9)-14(5), 41(12)-44(8))
Run/Power indicator
(PW)
Output indicator
(UP)
Time limit contact NC
(11(9)-12(1), 21(10)-22(2),
31(11)-32(3), 41(12)-42(4))
Time limit contact NO
(11(9)-14(5), 21(10)-24(6),
31(11)-34(7), 41(12)-44(8))
Run/Power indicator
(PW)
Output indicator
(UP)
Power
(A1(13)-A2(14))
H3Y Series
31
Precautions for H3Y-series Timers
Flush Mounting Adapter
Note: 1. Push the H3Y in until the Adaptor (Y92F-78) hooks engage with its rear panel.
2. Do not round the corners of the cutout on the rear panel surface, otherwise the Adaptor (Y92F-78) tabs may not engage properly.
Mounting Height
Note: 1. The are no restrictions to the mounting direction.
2. Always use the PYF-@-PU-L with the H3Y-@-B or H3YN-@-B.
*1. Models in parentheses are Connecting Sockets to the H3Y-4, H3YN-4/-41, or H3YN-4-Z/-41-Z.
*2. Models in parentheses are Connecting Sockets to the H3Y-4-B, H3YN-4-B/-41-B, or H3YN-4-Z-B/-41-Z-B.
*3. These values apply when the PFP-@N is used.
Add 9 mm if you use the PFP-@N2.
Connecting Sockets (Sold Separately)
H3Y/H3YN Series
Use one of the following Connecting Sockets: PYF@A, PYF@M, PY@, PY@-02, or PY@QN(2)(-Y3).
(@: 08 or 14)
H3Y-@-B/H3YN-@-B Series
Use one of the following Connecting Sockets: PYF-@-PU-L.
(@: 08 or 14)
33.5
27.1 48.5
31.5
25.1
3
3
5
25.2
+0.2
0
31.6
+0.2
0
R0.5 max.
Panel Cutout
(Excluding the H3Y-@-B and H3YN-@-B)
Y92F-78
Panel thickness
1 to 3 mm
PY08 (PY14)
PY08 (PY14 *1) PY08QN (PY14QN *1)
PYF08A (PYF14A)
PYF08A/PYF08A-N/PYF08A-E
(PYF14A/PYF14A-N/PYF14A-E *1)
H3YN
Series
H3YN
Series
H3YN
Series
PY08QN
(PY14QN)
H3Y(N)
-B
Series
PYF-08-PU-L (PYF-14-PU-L *2)
PYF-08-PU-L (PYF-14-PU-L)
88.6
92 *3
H3Y Series
32
Accessories (Order Separately)
Use the PYF@A, PY@, PY@-02, or PY@QN(2) to mount the H3Y/H3YN. Use the PYF-@-PU-L to mount the H3Y-@-B/H3YN-@-B.
When ordering any one of these sockets, replace “@” with “08” or “14.”
Socket Mounting Plates (t = 1.6)
(Excluding the H3Y-@-B and H3YN-@-B)
Use a Socket Mounting Plate to mount multiple Connecting Sockets in a row.
Note: PYP-18 may be cut to any desired length.
Relay Hold-down Clips
The Hold-down Clip makes it possible to mount the H3YN securely and prevent the H3YN from falling out due to vibration or shock.
Note: When you attach the Hold-down Clip to or remove it from the Socket, take sufficient precautions to not injury your fingers, such as wearing
gloves.
Y92H-3
Y92H-4
Applicable socket For mounting 1 socket For mounting 18 sockets
PY08, PY14, PY08QN(2), PY14QN(2) PYP-1 PYP-18
PYP-1
Two, 3.4-dia. holes
PYP-18
5 max.
53
4.5
1.24.5
H3Y/H3YN Series for PYF@A Socket
Y92H-3
(Set of Two Clips)
H3Y-@-B/H3YN-@-B Series
for PYF-@-PU-L Socket
Y92H-3
(Set of Two Clips)
Y92H-4 for PY@ Socket
(Excluding the H3Y-@-B and H3YN-@-B)
(84°)
2.5
20
33.7
24.5
30.5
R9
H3Y Series
33
H3Y/H3YN Series
Track Mounting/Front Connecting Sockets
Terminal Arrangement
(Top View)
PYF08A
6
72 max.
23 max.
30 max.
16.5
35.4
3.4
4
6
PYF@A
90.5 86.6
Two, 4.5 dia.
M4 or M3
59±0.3
15±0.2
Mounting Holes
Terminal Arrangement
(Top View)
PYF14A
Mounting Holes
6
72 max.
29.5 max.
30 max.
16.5
35.4
3.4
4
6
Two, 4.5 dia.
M4 or M3
59±0.3
22±0.2
Two, 4.2 × 5
mounting holes
Eight, M3 × 8
sems
Two, 4.2 × 5
mounting holes
Fourteen, M3 × 8
sems
H3Y
Series
PYF08A-N Terminal Arrangement Mounting Holes
(for Surface Mounting)
4
42
1
8 5
12 9
14 14 13
44
12
14
41 11
A2 A2 A1
19.8
3.2 dia.
3.6 dia.
4
42
8
44
1
12
5
14
41
12
A2
14
11
9
A1
13
A2
14
22 max.
66.5 max.
PYF-08A-N
30 max.
4 3 2 1
8 7 6 5
12 11 10 9
14 14 13
42 32 22 12
44 34 24 14
41 31 21 11
A2 A2 A1
20.8
Two, 3.5 dia.
30 max.
4
42
3
32
2
22
1
12
8
44
7
34
6
24
5
14
41
12
31
11
21
10
11
9
A1
13
A2
14
A2
14
66.5 max.
PYF-14A-N
29.5 max.
PYF14A-N Terminal Arrangement Mounting Holes
(for Surface Mounting)
H3Y Series
34
H3Y/H3YN Series
Back Connecting Sockets
PYF08A-E
31 max.
72 max.
23 max.
(Top View)
PYF14A-E
31 max.
29.5 max.
(Top View)
Two, 4.5 dia.
M4 or M3
Two, 4.5 dia.
M4 or M3
Two, 4.2 × 5
mounting holes Eight, M3 × 8
sems
Two, 4.2 × 5
mounting holes
Eight, M3 × 8
sems
72 max.
Panel Cutout
PY08, PY14
Terminal Arrangement
(Bottom View)
PY08QN, PY14QN
PY08QN(2), PY14QN(2)
PY08-02, PY14-02
29.5
max.
25.5
max.
24 max.
0.3
2.7 7.7
20 max.
2.6
29.5
max.
25.5
max.
22 max.
0.3
2.7 4.3
16.5 max.
2
(See
note)
2.7
29.5 max.
41.5 max.
(see note)
25 max. *
24 max.
22 max.
**
1 × 1
H3Y
Series
PY@, PY@-02,
PY@QN(2)
59.3
21.4+0.2
0
25.8+0.2
0
PY08-02 PY14-02
Terminal Arrangement
(Bottom View)
Terminal Arrangement
(Bottom View)
PY08QN
PY08QN(2)
PY14QN
PY14QN(2)
PY08 PY14
Eight, 3 × 1.2 dia. holes
only for PY08 (Fourteen,
3 × 1.2 dia. holes)
Note: With PY@QN(2), dimension * should read
20 max. and dimension ** 36.5 max.
H3Y Series
35
H3Y-@-B/H3YN-@-B Series
Front Connecting Sockets
25.6
30.8
28.1
35.3
27.35
25.6
34.3
43
3.9
52.1
52.1
(4.2)
(4.2)
90
31
14
42
44
41
12
11
A2A1
(13)
(1)
(5)
(4)
(8)
(9) (12)
(14)
Two M3 screw
holes or
two 3.5-dia. holes 108
PYF-08-PU-L
(TOP VIEW)
Mounting Hole
Dimensions
Terminal Arrangement/
Internal Connection Diagram
Note:
Pull out the hooks to
mount the Socket with
screws.
Note:
The numbers in
parentheses are
traditionally used
terminal numbers.
108
(1) (2) (3) (4)
(5) (6) (7) (8)
(9)
(10) (11) (12)
14
423222
443424
413121
12
11
A2A1
(13) (14)
25.6
30.8
28.1
35.3
27.35
25.6
34.3
43
3.9
52.1
52.1
(4.2)
(4.2)
90
31
Two M3 screw
holes or
two 3.5-dia. holes
PYF-14-PU-L
(TOP VIEW)
Note:
Pull out the hooks to
mount the Socket with
screws.
Note:
The numbers in
parentheses are
traditionally used
terminal numbers.
Mounting Hole
Dimensions
Terminal Arrangement/
Internal Connection Diagram
Mounting Track
PFP-100N/PFP-50N (see note 1)
End Plate
PFP-M
1000 (500) (See note 2)
Note: 1. Meets DIN EN50022
2. This dimension applies to PFP-50N.
Spacer
PFP-S
H3Y Series
36
Safety Precautions
Be sure to read precautions for all models in the website at the following URL: http://www.ia.omron.com/.
Warning Indications
Meaning of Product Safety Symbols
Risk of fire and explosion due to arcing and relay heat
generation that accompanies switching. Do not use in
an environment where flammable or explosive gas is
present.
The service life of the output relay varies widely
depending on switching capacity and switching
conditions. Use only within the rated load and electrical
life count, based on actual conditions of use. Risk of
contact sticking and burning if used past the service
life. Always use a load current that does not exceed the rating, and if
a heater is used, use a thermal switch in the load circuit.
Do not remove the outer casing.
In rare circumstances there is a risk of slight electrical
shock, fire, or device damage. Do not disassemble,
modify, repair, or otherwise touch the inside.
Tighten the screws for the lead wires to the Socket to
the following torque.
PYF Socket: 0.78 to 1.18 N·m
This is the recommended range when crimp terminals
are used.
If the screws are not tightened sufficiently on Front-connecting
Sockets, the lead wires may come off, connection failure may cause
abnormal heating, or fires may occur.
If they are tightened excessively, the screw threads may be damaged.
Confirm that the setting dial, indicators and plastic parts are operating
normally. Depending on the operating environment, the setting dial,
indicators and plastic parts may deteriorate faster than expected,
causing the indicators to fail. Periodically perform inspections and
replacements.
We recommend that you use a surge absorber if surge voltages may occur.
When you dispose of the Timer, do so according to all local
ordinances for processing industrial waste.
When selecting a control output, use the H3Y-2/H3YN-2/H3Y-2-B/
H3YN-2-B for switching ON and OFF the power and the H3Y-4/
H3YN-4/H3Y-4-B/H3YN-4-B for switching ON and OFF the minute
load. Gold-plated relays are used in the H3Y-4, H3YN-4, H3Y-4-B,
H3YN-4-B, H3YN-4-Z, H3YN-41-Z, H3YN-4-Z-B, and H3YN-41-Z-
B Series.
Connect the power supply between terminals A1 (13) and A2 (14).
For a DC power supply, connect the negative side to A1 (13) and
the positive side to A2 (14).
The operating voltage will increase when using the H3Y/H3YN/
H3Y-B/H3YN-B in any place where the ambient temperature is
more than 50°C. Supply 90% to 110% of the rated voltages (at
12 VDC: 95% to 110%) when operating at 45°C or higher.
Do not leave the H3Y/H3YN/H3Y-B/H3YN-B in time-up condition
for a long period of time (for example, more than one month in any
place where the ambient temperature is high), otherwise the
internal parts (aluminum electrolytic capacitor) may become
damaged. Therefore, the use of the H3Y/H3YN/H3Y-B/H3YN-B
with a relay as shown in the following circuit diagram is
recommended to extend the service life of the H3Y/H3YN/H3Y-B/
H3YN-B.
The H3YN/H3YN-B must be disconnected from the Socket when
setting the DIP switch, otherwise the user may touch a terminal
imposed with a high voltage and get an electric shock.
Do not connect the H3Y/H3YN/H3Y-B/H3YN-B as shown in the
following circuit diagram on the right hand side, otherwise the
H3Y's/H3YN's/H3Y-B's/H3YN-B's internal contacts different from
each other in polarity may become short-circuited.
Use the following safety circuit when building a self-holding or self-
resetting circuit with the H3Y/H3YN/H3Y-B/H3YN-B and an
auxiliary relay, such as an MY Relay, in combination.
CAUTION Indicates a potentially hazardous situation
which, if not avoided, may result in minor
or moderate injury or in property damage.
Precautions for
Safe Use
Supplementary comments on what to do
or avoid doing, to use the product safely.
Precautions for
Correct Use
Supplementary comments on what to do
or avoid doing, to prevent failure to
operate, malfunction or undesirable effect
on product performance.
Used for general prohibitions for which there is no
specific symbol.
Use to indicate prohibitions when there is a risk of
minor injury from electrical shock or other source if
the product is disassembled.
Used for general mandatory action precautions for
which there is no specified symbol.
CAUTION
Precautions for Safe Use
Precautions for Correct Use
Auxiliary relay such as MY Relay
L
2
L
1
L
2
L
1
Correct Incorrect
: H3Y
Auxiliary relay:
MY Relay
H3Y Series
37
In the case of the above circuit, the H3YN will be in pulse operation.
Therefore, if the circuit shown on page 13 is used, no auxiliary
relay will be required.
Do not set to the minimum setting in the flicker modes, otherwise
the contact may become damaged.
Be careful not to apply any voltage to the terminal screws on the
back of the Timer. Mount the product so that the screws will not
come in contact with the panel or metal parts.
Do not use the H3Y/H3YN/H3Y-B/H3YN-B in places where there
is excessive dust, corrosive gas, or direct sunlight.
Do not mount more than one H3Y/H3YN/H3Y-B/H3YN-B closely
together, otherwise the internal parts may become damaged.
Make sure that there is a space of 5 mm or more between any H3Y/
H3YN/H3Y-B/H3YN-B Models next to each other to allow heat
radiation.
The internal parts may become damaged if a supply voltage other
than the rated ones is imposed on the H3Y/H3YN/H3Y-B/H3YN-B.
When more than 100 V is applied to 12 or 24 VDC models, the
internal element (varistor) may break.
In order to conform to UL and CSA requirements when using the
H3Y-4/-4-0/-4-B, H3YN-4/-41/-4-B/-41-B, or H3YN-4-Z/-41-Z/
-4-Z-B/-41-ZB, connect the Unit so that output contacts (contacts
of different poles) have the same electric potential.
In cases such as PLC input where the load is extremely small for
the control output of a timer containing a power relay (using other
than gold-plated contacts), reliability can be increased by using
contacts of the same poles (e.g., the H3Y-2) in parallel.
Always use the same type of wire.
Installation
There are no restrictions on the installation orientation. Install the
Timer securely.
Precautions for EN 61812-1 Conformance
The H3Y/H3YN/H3Y-B/H3YN-B as a built-in timer conforms to EN
61812-1 provided that the following conditions are satisfied.
Handling
Do not touch the DIP switch while power is supplied to the H3YN/
H3YN-B.
Before dismounting the H3YN/H3YN-B from the Socket, make
sure that no voltage is imposed on any terminal of the H3YN/
H3YN-B.
The applicable Socket is the PYF@A (H3Y/H3YN) or PYF-@-PU-L
(H3Y-B/H3YN-B).
Only basic insulation is ensured between the Y92H-3 Hold-down
Clips and H3Y/H3YN/H3Y-B/H3YN-B internal circuits.
Do not allow the Y92H-3 Hold-down Clips to contact other parts.
The insulation test voltage between different pole contacts for the
4-pole model is the impulse voltage of 2.95 kV.
Wiring
The power supply for the H3Y/H3YN/H3Y-B/H3YN-B must be
protected with equipment such as a breaker approved by VDE.
Basic insulation is ensured between the H3Y's/H3YN's/H3Y-B's/
H3YN-B's operating circuit and control output.
Insulation requirement:
Overvoltage category II,
pollution degree 1 (H3Y-4/-4-0/-4-B, H3YN-4/41/-4-B/-41-B,
H3YN-4-Z/-41-Z/-4-Z-B/-41-Z-B),
pollution degree 2 (H3Y-2/-2-0/-2-B, H3YN-2/21/-2-B/-21-B)
(with a clearance of 1.5 mm and a creepage distance of 2.5 mm
at 240 VAC)
Output terminals next to each other on the H3Y-4 or H3Y-4-0 must
have the same polarity.
Recommended Replacement Periods and Periodic Replacement
as Preventive Maintenance
The recommended replacement period for preventive maintenance is
greatly influenced by the application environment of the product. As a
guideline for models that do not have a Maintenance Forecast
Monitor, the recommended replacement period is 7 to 10 years.* To
prevent failures that can be caused by using a product beyond its
service live, we recommend that you replace the product as early as
possible within the recommended replacement period. However,
realize that the recommended replacement period is for reference
only and does not guarantee the life of the product.
Many electronic components are used in the product and the product
depends on the correct operation of these components to achieve
product functions and performance. However, the influence of the
ambient temperature on aluminum electrolytic capacitors is large, and
the service life is reduced by half for each 10°C rise in temperature
(Arrhenius law). When the capacity reduction life of the electrolytic
capacitor is reached, the product may fail. We therefore recommend
that you replace the product periodically to minimize product failures
in advance.
*The following conditions apply: rated input voltage, load rate of 50%
max., ambient temperature of 35°C max., and the standalone
mounting method.
This product model is designed with a service life of 10 years
minimum under the above conditions.
MEMO
38
Terms and Conditions Agreement
Read and understand this catalog.
Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have
any questions or comments.
Warranties.
(a) Exclusive Warranty. Omron’s exclusive warranty is that the Products will be free from defects in materials and workmanship
for a period of twelve months from the date of sale by Omron (or such other period expressed in writing
by Omron). Omron disclaims all other warranties, express or implied.
(b) Limitations. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, ABOUT
NON-INFRINGEMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OF THE
PRODUCTS. BUYER ACKNOWLEDGES THAT IT ALONE HAS DETERMINED THAT THE PRODUCTS WILL
SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE.
Omron further disclaims all warranties and responsibility of any type for claims or expenses based on infringement by the Products
or otherwise of any intellectual property right. (c) Buyer Remedy. Omron’s sole obligation hereunder shall be, at Omron’s election,
to (i) replace (in the form originally shipped with Buyer responsible for labor charges for removal or replacement thereof) the
non-complying Product, (ii) repair the non-complying Product, or (iii) repay or credit Buyer an amount equal to the purchase price
of the non-complying Product; provided that in no event shall Omron be responsible for warranty, repair, indemnity or any other
claims or expenses regarding the Products unless Omron’s analysis confirms that the Products were properly handled, stored,
installed and maintained and not subject to contamination, abuse, misuse or inappropriate modification. Return of any Products by
Buyer must be approved in writing by Omron before shipment. Omron Companies shall not be liable for the suitability or
unsuitability or the results from the use of Products in combination with any electrical or electronic components, circuits, system
assemblies or any other materials or substances or environments. Any advice, recommendations or information given orally or in
writing, are not to be construed as an amendment or addition to the above warranty.
See http://www.omron.com/global/ or contact your Omron representative for published information.
Limitation on Liability; Etc.
OMRON COMPANIES SHALL NOT BE LIABLE FOR SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES,
LOSS OF PROFITS OR PRODUCTION OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS,
WHETHER SUCH CLAIM IS BASED IN CONTRACT, WARRANTY, NEGLIGENCE OR STRICT LIABILITY.
Further, in no event shall liability of Omron Companies exceed the individual price of the Product on which liability is asserted.
Suitability of Use.
Omron Companies shall not be responsible for conformity with any standards, codes or regulations which apply to the
combination of the Product in the Buyer’s application or use of the Product. At Buyer’s request, Omron will provide applicable
third party certification documents identifying ratings and limitations of use which apply to the Product. This information by itself is
not sufficient for a complete determination of the suitability of the Product in combination with the end product, machine, system,
or other application or use. Buyer shall be solely responsible for determining appropriateness of the particular Product with
respect to Buyer’s application, product or system. Buyer shall take application responsibility in all cases.
NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY OR IN LARGE
QUANTITIES WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS,
AND THAT THE OMRON PRODUCT(S) IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE
OVERALL EQUIPMENT OR SYSTEM.
Programmable Products.
Omron Companies shall not be responsible for the user’s programming of a programmable Product, or any consequence thereof.
Performance Data.
Data presented in Omron Company websites, catalogs and other materials is provided as a guide for the user in determining
suitability and does not constitute a warranty. It may represent the result of Omron’s test conditions, and the user must correlate it
to actual application requirements. Actual performance is subject to the Omron’s Warranty and Limitations of Liability.
Change in Specifications.
Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our practice
to change part numbers when published ratings or features are changed, or when significant construction changes are made.
However, some specifications of the Product may be changed without any notice. When in doubt, special part numbers may be
assigned to fix or establish key specifications for your application. Please consult with your Omron’s representative at any time to
confirm actual specifications of purchased Product.
Errors and Omissions.
Information presented by Omron Companies has been checked and is believed to be accurate; however, no responsibility is
assumed for clerical, typographical or proofreading errors or omissions.
Authorized Distributor:
In the interest of product improvement,
specifications are subject to change without notice.
Cat. No. M092-E1-02 1018 (0316)
© OMRON Corporation 2016-2018 All Rights Reserved.
OMRON Corporation Industrial Automation Company
OMRON ELECTRONICS LLC
2895 Greenspoint Parkway, Suite 200
Hoffman Estates, IL 60169 U.S.A.
Tel: (1) 847-843-7900/Fax: (1) 847-843-7787
Regional Headquarters
OMRON EUROPE B.V.
Wegalaan 67-69, 2132 JD Hoofddorp
The Netherlands
Tel: (31)2356-81-300/Fax: (31)2356-81-388
Contact: www.ia.omron.com
Kyoto, JAPAN
OMRON ASIA PACIFIC PTE. LTD.
No. 438A Alexandra Road # 05-05/08 (Lobby 2),
Alexandra Technopark,
Singapore 119967
Tel: (65) 6835-3011/Fax: (65) 6835-2711