Motor Description
1.2 Order designation
1FT5/1-15
Siemens AG 2003 All rights reserved
AC Servomotors 1FT5 (PFT5) – 05.03 Edition
Supplementary data for standard types and options
Plain text data Brief designation
Degree of protection IP 67 (not for force–ventilated motors) 7)
IP 68 (not for force–ventilated motors) 7) K93
M24
Second rating plate (this is standard for core types) K31
Connector outlet direction 1) Cable entry from the drive end K83 4) 7) 11)
Cable entry from the non–drive end K84 4) 7)
rotated through 180° (with respect to the Standard) K85 7)
Radial shaft sealing acc. to DIN 3760 K18
Shaft end: Smooth shaft K42
Vibration severity (ISO 2373)
Severity R (reduced) 600 to 1800 RPM v0.71 mm/s
>1800 to 3600 RPM v1.12 mm/s
K01
Shaft and flange precision, tolerance R acc. to DIN 42955 K04
Motor with mounted pulse encoder 9)
5000 pulses/revolutions 7)
2500 pulses/revolutions 7)
2000 pulses/revolutions 7)
1000 pulses/revolutions 7)
H28
H27
H26
H22
The motor is prepared for mounting an encoder (incremental or absolute) with
synchronous flange 2) 7) 11) G51
Motor with mounted ROD 320 pulse encoder 3) 6)
5000 pulses/revolutions 7)
2500 pulses/revolutions 7)
2000 pulses/revolutions 7)
1250 pulses/revolutions 7)
H04
G44
G42
H01
Holding brake (integrated) 8) G45
Motor with mounted planetary gear 10) 11) V
W orking brake; mounted 4) 11) C00
Prepared with a retrofit kit for mounting an encoder (G51) with mounting
instructions 5) EWN:
519.4033804: 1FT5034 to 1FT5036
519.4033803: 1FT5042 to 1FT5046
519.4033801: 1FT5062 to 1FT5066
519.4033802: 1FT5072 to 1FT5108
1) Standard version corresponding to the dimension drawings
2) For 1FT503, 1FT504 absolute value encoder mounting, only on request; not for force–ventilated motors
3) For 1FT503, 1FT504not possible; not for force–ventilated motors
4) For 1FT503, 1FT504 and 1FT506 not possible
5) Only available ex–stock up to 2 motors per motor version
6) Limiting frequency: 300 kHz; motors may only be designed for a winding temperature rise ∆T=60 K.
Cannot be combined with an axial connector outlet at the non–drive end.
7) Options mutually exclude one another
8) For motors with brake, axial forces are not permissible in operation
9) Pulse encoder with axial cable outlet
10) Only vibration severity stage N can be guaranteed for the motor and gearbox unit
11) Not possible for short motors
05.03