www.recom-power.com REV.: 5/2019 I-4
DC/DC Converter
Specifications (measured @ Ta= 25°C, 10% minimum load, unless otherwise stated)
R-78xx-0.5
Series
ENVIRONMENTAL
Parameter Condition
Operating Temperature Range with derating (see graph) -40°C to +85°C
Maximum Case Temperature +100°C
Temperature Coefficient ±0.015%/K
Thermal Impedance 0.1m/s, vertical 70K/W
Operating Altitude 2000m
Operating Humidity non-condensing 95% RH max.
Pollution Degree PD2
MTBF according to MIL-HDBK-217F, G.B. +25°C 26163 x 103 hours
SAFETY AND CERTIFICATIONS
Certificate Type (Safety) Report / File Number Standard
Information Technology Equipment, General Requirements for Safety
1603123 IEC60950-1:2005, 2nd Edition + Am 2:2013
EN60950-1:2006 + Am 2:2013
EAC RU-AT.49.09571 TP TC 004/2011
RoHs 2+ RoHS 2011/65/EU + AM2015/863
EMC Compliance Condition Standard / Criterion
Electromagnetic compatibility of multimedia equipment -
Emission requirements
with external filter
(see filter suggestion below) EN55032, Class A and B
ESD Electrostatic discharge immunity test Contact ±6kV EN61000-4-2, Criteria A
Radiated, radio-frequency, electromagnetic field immunity test 3V/m EN61000-4-3, Criteria A
Fast Transient and Burst Immunity ±1.0kV EN61000-4-4, Criteria A
Immunity to conducted disturbances, induced by radio-frequency fields
3V EN61000-4-6, Criteria A
Power Magnetic Field Immunity 50Hz, 3A/m EN61000-4-8, Criteria A
continued on next page
-40 60
71
80
85
10040200
0
20
40
60
80
100
Ambient Temperature [°C]
Output Power [%]
Derating Graph