FEATURES
Surage overload rating -50 amperes peak
Ideal for printed circuit board
Plastic material has Underwriters Laboratory
flammability classification 94V-0
Mounting position :Any
MAXIMUM RATINGS AND ELECTRICAL CHARACTERISTICS
Rating at 25 ambient temperature unless otherwise specified.
Resistive or inductive load,60HZ.
For capacitive load, derate current by 20%
CHARACTERISTICS SYMBOLKBP005GKBP01GKBP02GKBP04GKBP06GKBP08GKBP10G UNIT
Maximum Recurrent Peak Reverse Voltage VRRM 50 100 200 400 600 800 1000 V
Maximum RMS Bridge Input Voltage VRMS 35 70 140 280 420 560 700 V
Maximum DC Blocking Voltage VDC 50 100 200 400 600 800 1000 V
Maximum Average Forward
Rectified Output Current @TA=50
Peak Forward Surage Current
8.3ms Single Half Sine-Wave
Super Imposed on Rated Load (JEDEC Method)
Maximum Forward Voltage Drop
Per Bridge Element at 1.5A Peak
Maximum Reverse Current at Rated
DC Blocking Voltage Per Element @TA=25
Maximum Reverse Current at Rated
DC Blocking Voltage Per Element @TA=100
Operating Temperature RangeTJTJ
Storage Temperature Range TATSTG
~ 273 ~
IR10 uA
IR1.0 mA
KBP005G thru KBP10G
-55 to +150
-55 to +150
1.5
V
50 A
A
GLASS PASSIVATED
VF1.1
I(AV)
IFSM
BRIDGE RECTIFIERS
Dimensions in inches and (millimeters)
REVERSE VOLTAGE - 50 to 1000 Volts
FORWARD CURRENT - 1.5Amperes
KBP
.600(15.24)
.560(14.22)
.420(10.67)
.460(11.68)
.460(11.68)
.500(12.70)
MIN.
.640
(16.25) (12.7)
.50 MIN.
.034(0.86)
.028(0.76)
.060
(1.52) .140(3.6)
.160(4.1)
.180(4.57)
.200(5.08)
.053(1.35)
.161(1.15)
.125X45°
(3.2)
MAX.
RATING AND CHARACTERISTIC CURVES
~ 274 ~
KBP005G thru KBP10G
FIG.1-DERATING CURVE OUTPUT RECTIFIED CURRENT
AMBIENT TEMPERATURE,
AVERAGE FORWARD CURRENT
AMPERES
SINGLE PHASE HALF WAVE 60Hz
RESISTIVE OR INDUCTIVE LOAD
50 100 150
0.00
0.50
1.00
1.50
INSTANTANEOUS FORWARD CURRENT
AMPERES
FIG.2-TYPICAL FORWARD
CHARACTERISTICS
INSTANTANEOUS FORWARD VOLTAGE. VOLTS
0.4 0.6 0.8 1.0 1.2 1.4
0.01
0.1
1.0
10.0
20.0
00.2
TJ=25
NUMBER OF CYCLES AT 60Hz
FIG.4-MAXIMUM FORWARD SURGE CURRENT
PEAK FORWARD SURGE CURRENT,
AMPERES
0
10
20
40
50
1
2
100
TJ=25
PERCENT OF RATED PEAK REVERSE VOLTAGE
INSTANTANEOUS REVERSE CURRENT,
MICROAMPERES
FIG.3-TYPICAL REVERSE CHARACTERISTICS
0.01
0.1
1.0
10
20
80 100 120
140