10
PRECAUTIONS FOR PROPER USE
Mounting
GX-8 type
Never use this product as a sensing device for
personnel protection.
In case of using sensing devices for personnel
protection, use products which meet laws and
standards, such as OSHA, ANSI or IEC etc., for
personnel protection applicable in each region or
country.
•
•
Make sure to use a M3
(length: 12 mm 0.472 in or
more) truss head screw.
The tightening torque
should be 0.7 N·m or less.
Do not use a fl at head
screw or a pan head
screw.
•
Infl uence of surrounding metal
When there is a metal near the sensor, keep the minimum
separation distance specifi ed below.
•
Front sensing type GX-F8 type GX-F12 type
A 7.4 mm 0.291 in 7.1 mm 0.280 in
B 8 mm 0.315 in 20 mm 0.787 in
C 3 mm 0.118 in 7 mm 0.276 in
Top sensing type
GX-12 type
The tightening torque should
be 0.7 N·m or less.
To mount the sensor with
a nut, the mouting hole
diameter should be "3.4 mm
"0.134 in. Further, the hole
in which the boss is inserted
should be "2.5 mm "0.098 in
and 3 mm 0.118 in, or more,
deep.
•
•
GX-H8 type GX-H12 type
D 4 mm 0.157 in 7 mm 0.276 in
E 10 mm 0.394 in 20 mm 0.787 in
F 3 mm 0.118 in 3 mm 0.118 in
G 3 mm 0.118 in 3 mm 0.118 in
M3 (length 12 mm 0.472 in or more)
pan head screw
(Please arrange separately.)
M3 × 0.5 mm 0.020 in tapped hole
(Depth: 10 mm 0.394 in or more)
or "3.4 mm "0.134 in thru-hole
If mounting using nut
and washers
(Please arrange separately.)
16 mm 0.630 in
"2.5 mm "0.098 in hole
(Depth: 3 mm 0.118 in or more)
Metal
AMetal Metal
CC
B
G
G
Metal
Metal
Metal
EF
D
Metal
Mutual interference prevention
When two or more sensors are installed in parallel or face to
face, keep the minimum separation distance specifi ed below to
avoid mutual interference.
•
Front sensing
Top sensing
HJ
GX-F8□
GX-H8□
Between “I” type
and non “I” type
0 mm
(Note 2)
15 mm
0.591 in
Between two “I” types
or two non “I” types
20 mm
0.787 in
35 mm
1.378 in
GX-F12□
GX-H12□
Between “I” type
and non “I” type
0 mm
(Note 2)
25 mm
0.984 in
Between two “I” types
or two non “I” types
25 mm
0.984 in
50 mm
1.969 in
H
H
J
Sensing range
The sensing range is specifi ed for the standard sensing object.
With a non-ferrous metal, the sensing range is obtained by
multiplying with the correction coeffi cient specifi ed below.
Further, the sensing range also changes if the sensing object is
smaller than the standard sensing object or if the sensing object
is plated.
•
Correction coeffi cient
Model
No.
Metal
GX-8 type GX-12 type
Iron 1 1
Stainless steel
(SUS304) 0.76 approx. 0.79 approx.
Brass 0.50 approx. 0.56 approx.
Aluminum 0.48 approx. 0.53 approx.
Others
This product has been developed / produced for industrial use
only.
The output does not incorporate a short-circuit protection circuit.
Do not connect it directly to a power supply or a capacitive load.
Do not use during the initial transient time (50 ms) after the
power supply is switched on.
Extension up to total 100 m 328.084 ft is possible with a
0.3 mm2, or more, cable.
•
•
•
•
M3 (length 12 mm 0.472 in) truss head
screw(Accessory for MS-GXL8-4)
M3 × 0.5 mm 0.020 in tapped hole
(Depth: 8 mm 0.315 in or more)
or "3.4 mm "0.134 in thru-hole
If mounting using nut
and washers
(Accessories for MS-GXL8-4)
"2.4 mm "0.098 in hole
(Depth: 3 mm 0.118 in or more)
MS-GXL8-4 (Accessory)
11.5 mm 0.453 in
HJ
Notes: 1) “I” in the model No. specifi es
the different frequency type.
2) Close mounting is possible for up
to two sensors.
When mounting three sensors
or more at an equal spacing,
align the model with “I” and the
model without “I” alternately. The
minimum value of dimension “H”
should be as given below.
GX-8 type: 6 mm 0.236 in
GX-12 type: 6.5 mm 0.256 in
SENSING CHARACTERISTICS (TYPICAL)
GX-8 type GX-12 type
Sensing fi eld
Correlation between sensing
object size and sensing range
Sensing fi eld Correlation between sensing
object size and sensing range
L L
ℓ
ℓ
4
0.157
2
0.079
0 2
0.079 4
0.157
Operating point ℓ (mm in)
Standard sensing object
Iron sheet 15 × 15 × t 1 mm
0.591 × 0.591 × t 0.039 in
Standard sensing object
Iron sheet 15 × 15 × t 1 mm
0.591 × 0.591 × t 0.039 in
Top sensing
Front sensing
Center Right Left
0
1
0.039
2
0.079
0.157
3
0.118
Setting distance L (mm in)
L L
Front sensing
Sensing object
a × a mm a × a in
t 1 mm
t 0.039 in t 1 mm
t 0.039 in
Sensing object
a × a mm a × a in
Top sensing
1
0.039
2
0.079
0.157
3
0.118
Sensing range L (mm in)
Sensing object side
length a (mm in)
5
0.197
10
0.394
15
0.591
20
0.787
0
Iron
Stainless steel
(SUS304) Brass
Aluminum
10
0.394
5
0.197
0 5
0.197 10
0.394
Operating point ℓ (mm in)
ℓ ℓ
Center Right Left
L
L
Standard sensing object
Iron sheet 20 × 20 × t 1 mm
0.
787
× 0.
787
× t 0.039 in
Standard sensing object
Iron sheet 20 × 20 × t 1 mm
0.787 × 0.787 × t 0.039 in
Top sensing Front sensing
0
2
0.079
4
0.157
0.315
6
0.236
Setting distance L (mm in)
Sensing object side
length a (mm in)
Sensing range L (mm in)
L
L
10
0.394
20
0.787
30
1.181
40
1.575
0
2
0.079
4
0.157
0.315
6
0.236
t 1 mm
t 0.039 in
Top sensing
t 1 mm
t 0.039 in
Iron
Stainless steel
(SUS304)
Brass
Aluminum
Front sensing
Sensing object a × a mm a × a in
Sensing
object
a × a mm
a × a in
As the sensing object size becomes smaller
than the standard size (iron sheet 15 × 15 ×
t 1 mm 0.591 × 0.591 × t 0.039 in), the sensing
range shortens as shown in the left fi gures.
As the sensing object size becomes smaller
than the standard size (iron sheet 20 × 20 ×
t 1 mm 0.787 × 0.787 × t 0.039 in), the sensing
range shortens as shown in the left fi gure.