SPECIFICATION
RSP-500-15
RSP-500-12 RSP-500-24 RSP-500-27 RSP-500-48RSP-500-5RSP-500-4RSP-500-3.3
MODEL
DC VOLTAGE
RATED CURRENT
CURRENT RANGE
RATED POWER
RIPPLE & NOISE (max.)
Note.2
OUTPUT VOLTAGE ADJ. RANGE
VOLTAGE TOLERANCE
Note.3
LINE REGULATION
LOAD REGULATION
SETUP, RISE TIME
HOLD UP TIME (Typ.)
VOLTAGE RANGE Note.4
FREQUENCY RANGE
POWER FACTOR (Typ.)
EFFICIENCY (Typ.)
INPUT
ENVIRONMENT
INRUSH CURRENT (Typ.)
LEAKAGE CURRENT
OVER TEMPERATURE
SAFETY STANDARDS
SAFETY &
EMC
(Note.4)
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
WORKING TEMP.
REMOTE CONTROL
REMOTE SENSE
FAN CONTROL (Typ.)
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
MTBF
DIMENSIONOTHERS
NOTE
PACKING
OVERLOAD
OVER VOLTAGE
PROTECTION
FUNCTION
15V12V 24V 27V 48V5V4V3.3V
33.4A41.7A 21A 18.6A 10.5A90A90A90A
0 ~ 33.4A0 ~ 41.7A 0 ~ 21A 0 ~ 18.6A 0 ~ 10.5A0 ~ 90A0 ~ 90A0 ~ 90A
501W500.4W 504W 502.2W 504W450W360W297W
150mVp-p150mVp-p 150mVp-p 150mVp-p 150mVp-p150mVp-p120mVp-p120mVp-p
4.5 ~ 5.5V3.6 ~ 4.3V2.8 ~ 3.6V 13.5 ~ 18V10 ~ 13.2V 20 ~ 26.4V 26 ~ 30V 41 ~ 56V
±1.0%±1.0% ±1.0% ±1.0% ±1.0%±2.0%±2.0%±2.0%
±0.3%±0.3% ±0.2% ±0.2% ±0.2%±0.5%±0.5%±0.5%
±0.5%±0.5% ±0.5% ±0.5% ±0.5%
±1.0%±1.0%±1.0%
1500ms, 80ms/230VAC 3000ms, 80ms/115VAC at full load
18ms/230VAC 14ms/115VAC at full load
85 ~ 264VAC 120 ~ 370VDC
47 ~ 63Hz
PF>0.95/230VAC PF>0.98/115VAC at full load
88% 88% 89% 89.5% 90.5%
84%
83%81%
20A/115VAC 40A/230VAC
<2mA / 240VAC
105 ~ 130% rated output power
13.8 ~ 16.2V 18.8 ~ 21.8V 27.6 ~ 32.4V 32.9 ~ 38.3V 58.4 ~ 68V
5.75 ~ 6.75V4.5 ~ 5.3V3.8 ~ 4.5V
Protection type : , recovers automatically after fault condition is removedConstant current limiting
Protection type : Shut down o/p voltage, re-power on to recover
Shut down o/p voltage, recovers automatically after temperature goes down
UL62368-1, TUV EN62368-1 EAC TP TC 004 , CCC GB4943.1 BSMI CNS14336-1approved
,
,
Compliance to EN55032 (CISPR32) Class B, EN61000-3-2,-3, EAC TP TC 020,GB/T 9254, CNS13438 Class B
Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, EN61000-6-2, EN61204-3 heavy industry level, criteria A, EAC TP TC 020
I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH℃
-30 ~ +70 (Refer to "Derating Curve")℃
POWER ON:open or 0~0.8VDC between RC+(Pin 4)&RC-(Pin3) on CN100
Compensate voltage drop on the load wiring up to 0.3V
RTH2 50 10 Fan on ; RTH2 40 10 Fan off (Fan always on for 3.3~5V,Fan ON/OFF control for 12~48V)≧℃±℃ ≦℃±℃
20 ~ 90% RH non-condensing
-40 ~ +85 , 10 ~ 95% RH℃
±℃℃0.03%/ (0 ~ 50 )
10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
187.7K hrs min. MIL-HDBK-217F (25 )℃
230*127*40.5mm (L*W*H)
1.3Kg; 9pcs/12.7Kg/0.7CUFT
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.℃
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Derating may be needed under low input voltages. Please check the derating curve for more details.
5. Fan always on for 3.3~5V,Fan ON/OFF control for 12~48V.
6. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it
still meets EMC directives.For guidance on how to perform these EMC tests, please refer to EMI testing of component power supplies.
(as available on http://www.meanwell.com)
7. The ambient temperature derating of 3.5 /1000m with fanless models and of 5 /1000m with fan models for operating altitude higher than ℃℃
2000m(6500ft).
EMC IMMUNITY
EMC EMISSION
5.3A/115VAC 2.65 A/230VAC
4.2A/115VAC 2.1 A/230VAC
AC CURRENT (Typ.)
POWER OFF: 4~10VDC between RC+(Pin 4)&RC-(Pin3) on CN100
500W Single Output with PFC Function RSP-500 series
File Name:RSP-500-SPEC 2020-04-13