© 2019 Kingbright. All Rights Reserved. Spec No: DSAP1125 / 1201008976 Rev No: V.3B Date: 11/07/2019 Page 5 / 6
RELIABILITY TEST ITEMS AND CONDITIONS
The reliability of products shall be satisfied with items listed below
LOT TOLERANCE PERCENT DEFECTIVE (LTPD) : 10%
No. Test Item Standards Test Condition Test Times /
Cycles Number of
Damaged
1 Continuous operating test - Ta = 25°C, IF = maximum rated current * 1,000 h 0 / 22
2 High Temp. operating test EIAJ ED-4701/100(101) Ta = 100°C, IF = maximum rated current * 1,000 h 0 / 22
3 Low Temp. operating test - Ta = -40°C, IF = maximum rated current * 1,000 h 0 / 22
4 High temp. storage test EIAJ ED-4701/100(201) Ta = maximum rated storage temperature 1,000 h 0 / 22
5 Low temp. storage test EIAJ ED-4701/100(202) Ta = -40°C 1,000 h 0 / 22
6 High temp. & humidity storage test - Ta = 60°C, RH = 90% 500 h 0 / 22
7 High temp. & humidity operating test - Ta = 60°C, RH = 90% IF = maximum rated current * 500 h 0 / 22
8 Soldering reliability test EIAJ ED-4701/100(301)
Moisture soak: 30°C, 70% RH, 72h
Preheat: 150~180°C (120s max.)
Soldering temp: 260°C(10s)
2 times 0 / 18
9 Thermal shock operating test - Ta = -40°C(15min) ~ 100°C(15min)
IF = derated current at 100°C 1,000 cycles 0 / 22
10 Thermal shock test - Ta = -40°C(15min) ~ maximum rated
storage temperature(15min) 1,000 cycles 0 / 22
11 Electric Static Discharge (ESD) EIAJ ED-4701/100(304) C = 100pF, R2 = 1.5KΩ V = 8000V Once each
Polarity 0 / 22
12 Vibration test - a = 196m/s², f = 100~2KHz, t = 48min for all xyz axes 4 times 0 / 22
* : Refer to forward current vs. derating curve diagram
AA4040VRBXZ1S/A-2A
CRITERIA FOR JUDGING DAMAGE
Items Symbols Conditions Failure Criteria
luminous Intensity lV IF = 20mA Testing Min. Value < Spec. Min. Value x 0.5
Forward Voltage VF IF = 20mA Testing Max. Value ≥ Spec. Max. Value x 1.2
Reverse Current IR VR = Maximum Rated Reverse Voltage Testing Max. Value ≥ Spec. Max. Value x 2.5
High temp. storage test - - Occurrence of notable decoloration,
deformation and cracking