BATTERY PROTECTION IC FOR 3-SERIAL OR 4-SERIAL CELL PACK
S-8243A/B Series Rev.2.4_00
Seiko Instruments Inc.
10
(2) S-8243B Series Table 7 (1/2) (Ta = 25°C unless otherwise specified)
Item Symbol Conditions Min. Typ. Max. Unit Test circuit
DETECTION VOLTAGE
Overcharge detection voltage n
n=1, 2, 3, 4 VCUn 3.9 V to 4.4 V, 50 mV Step VCUn
−0.025 VCun
VCUn
+0.025 V 4
Hysteresis voltage n of overcharge
detection
n=1, 2, 3, 4 VHCn −0.10 V to −0.40 V, and 0 V VHCn
−0.05 VHCn VHCn
+0.05 V 4
Overdischarge detection voltage
n=1, 2, 3, 4 VDLn 2.0 V to 3.0 V, 100 mV Step VDLn
−0.08 VDLn VDLn
+0.08 V 4
Hysteresis voltage n of
overdischarge detection
n=1, 2, 3, 4 VHDn 0.20 to 0.70, and 0 VHDn
−0.10 VHDn VHDn
+0.10 V 4
Overcurrent detection voltage 1 VIOV1 0.05 V to 0.3 V, 50 mV Step VIOV1
−0.025 VIOV1 VIOV1
+0.025 V 4
Overcurrent detection voltage 2 VIOV2 ⎯ VDD−0.60 VDD−0.50 VDD−0.40 V 4
Overcurrent detection voltage 3 VIOV3 ⎯ VDD
×0.425 VDD
×0.5 VDD
×0.575 V 4
Temperature coefficient for
detection and release voltage*1 TCOE1 Ta= −5°C to +55°C −1.0 0 1.0 mV/°C4
Temperature coefficient for
overcurrent detection voltage*2 TCOE2 Ta= −5°C to +55°C −0.5 0 0.5 mV/°C4
0 V BATTERY CHARGING FUNCTION (The 0 V battery function is either "0 V battery charging is allowed." or "0 V battery charging is
inhibited." depending upon the product type.)
0 V battery charge starting charger
voltage V0CHA 0 V battery charging allowed ⎯ 0.8 1.5 V 7
0 V battery charge inhibition battery
voltage V0INH 0 V battery charging inhibited 0.4 0.7 1.1 V 7
INTERNAL RESISTANCE
Internal resistance between VMP
and VDD RVDM V1=V2=V3=V4=3.5 V 500 1100 2400 kΩ 8
Internal resistance between VMP
and VSS RVSM V1=V2=V3=V4=1.8 V 300 700 1500 kΩ 8
VOLTAGE REGULATOR
Output voltage VOUT V
DD=14V, IOUT=3 mA 3.221 3.300 3.379 V 2
Line regulation ΔVOUT1 V
DD=6 V→18 V, IOUT=3 mA ⎯ 5 15 mV 2
Load regulation ΔVOUT2 V
DD=14 V, IOUT=5 μA→3 mA ⎯ 15 30 mV 2
BATTERY MONITOR AMP
Input offset voltage n
n=1, 2, 3, 4 VOFFn V1=V2=V3= V4=3.5 V 60 165 270 mV 3
Voltage gain n
n=1, 2, 3, 4 GAMPn V1=V2=V3= V4=3.5 V 0.2×0.99 0.2 0.2×1.01 ⎯ 3
INPUT VOLTAGE, OPERATING VOLTAGE
Operating voltage between VDD
and VSS VDSOP ⎯ 6 ⎯ 18 V 4
CTL1 input voltage for High VCTL1H ⎯ VDD×0.8 ⎯ ⎯ V 6
CTL1 input voltage for Low VCTL1L ⎯ ⎯ ⎯ VDD×0.2 V 6
CTLn input voltage for High
n=2, 3, 4 VCTLnH ⎯ VOUT×0.9 ⎯ VOUT V 3, 6
CTLn input voltage for Low
n=2, 3, 4 VCTLnL ⎯ ⎯ ⎯ VOUT×0.1 V 3, 6