139
Related Information
Selection
Guide
Fibers
Fiber
Ampliers
FX-500
FX-100
FX-300
FX-410
FX-311
FX-301-F7/
FX-301-F
FIBER
SENSORS
LASER
SENSORS
PHOTOELECTRIC
SENSORS
MICRO
PHOTOELECTRIC
SENSORS
AREA
SENSORS
LIGHT CURTAINS /
SAFETY
COMPONENTS
PRESSURE /
FLOW
SENSORS
INDUCTIVE
PROXIMITY
SENSORS
PARTICULAR
USE SENSORS
SENSOR
OPTIONS
SIMPLE
WIRE-SAVING
UNITS
WIRE-SAVING
SYSTEMS
MEASUREMENT
SENSORS
STATIC ELECTRICITY
PREVENTION
DEVICES
LASER
MARKERS
PLC
HUMAN MACHINE
INTERFACES
ENERGY CONSUMPTION
VISUALIZATION
COMPONENTS
FA COMPONENTS
MACHINE VISION
SYSTEMS
UV CURING
SYSTEMS
Digital Fiber Sensor
FX-300 SERIES
SC-GU1-485 .............................. P.1009~
Constant advances achieving signicant
improvement of sensing performance
Conforming to
EMC Directive Recognition
PNP output
type available
Timer
Light intensity
monitor
Automatic
sensitivity setting
Interference
prevention
In addition to a “four-chemical emitting element” which
suppresses changes in the light emitting element over
time so that a stable level of light emission can be
maintained over long periods, a “APC (Auto Power
Control) circuit” has also been adopted afresh. The light
emitting amount can be controlled in minute degrees
so that even changes occurring over very short periods
can be handled, allowing stable sensing performance by
suppressing deviations in light emitting amounts caused
by changes in the ambient environment that could not
previously be suppressed.
Stable sensing over long and short periods
FX-301 FX-301-HS FX-305 Even greater sensing range All models
Adoption of a “double coupling lens” that increases
emission efciency to its maximum limits and greatly
increases sensing range. Sensing ranges with small
diameter bers and ultra-small diameter bers, which
have become very popular due to the miniaturization of
chip components, have been increased by 50 % over
previous values achieved with other ampliers.
● Stable sensing comparison
Three-chemical emitting element,
Without APC
FX-301
FX-301-HS
FX-305
Time
Long-term stability
Short-term stability
Deviation
Light emitting amount
Disperses the light reduces
emitting efficiency.
• Conventional ber sensors (Without lens)
The lens concentrates the light, greatly
increasing emitting efficiency.
• Double coupling lens
Certified
General precautions ................... P.1458~ Korea’s S-mark ............................. P.1506
General terms and conditions ............. F-7
Glossary of terms........................ P.1455~
Sensor selection guide
……………… P.3~
NPN output types of
connector type only
* UL 61010C-1 compatible, Passed the UL 991
Environment Test based on SEMI S2-0200.
[Category applicable for semiconductor
manufacturing: TWW2, Process Equipment]
[Applicable standards: UL 61010C-1]
[Additional test / evaluation standards as per intended
use: UL 991, SEMI S2-0200]
* Passed the UL 991 Environment Test
panasonic.net/id/pidsx/global
Digital Fiber Sensor FX-300 SERIES
140
Selection
Guide
Fibers
Fiber
Ampliers
FX-500
FX-100
FX-300
FX-410
FX-311
FX-301-F7/
FX-301-F
FIBER
SENSORS
LASER
SENSORS
PHOTOELECTRIC
SENSORS
MICRO
PHOTOELECTRIC
SENSORS
AREA
SENSORS
LIGHT CURTAINS /
SAFETY
COMPONENTS
PRESSURE /
FLOW
SENSORS
INDUCTIVE
PROXIMITY
SENSORS
PARTICULAR
USE SENSORS
SENSOR
OPTIONS
SIMPLE
WIRE-SAVING
UNITS
WIRE-SAVING
SYSTEMS
MEASUREMENT
SENSORS
STATIC ELECTRICITY
PREVENTION
DEVICES
LASER
MARKERS
PLC
HUMAN MACHINE
INTERFACES
ENERGY CONSUMPTION
VISUALIZATION
COMPONENTS
FA COMPONENTS
MACHINE VISION
SYSTEMS
UV CURING
SYSTEMS
Large display 9999 FX-305
Large display with 4 digits (9999). With a greater
difference in digit value than previous models, threshold
values can be set in units of 1 digit up to maximum 9999.
Threshold setting can now be done more easily and
accurately.
Ultra high-speed
35 µs response FX-301-HS FX-305
Ultra high-speed 35 µs response. Even small objects
moving at high speeds can be sensed. In addition, at 65
µs the FX-301 standard
type and FX-305 high-
function type is also
twice as fast as previous
models.
(During STDF, LONG and U-LG modes)
2.5 times
previous
models
FX-305
9999
Previous models
4000
Digit difference: Small Digit difference: Large
Digit difference comparison
Example Digit difference between object A and object B
4 times as fast
as before
35 µs
Ultra high-speed type FX-301-HS
Standard type FX-301, High-function type FX-305
Previous model
35 μs
65 μs
150 μs
(H-SP mode)
(H-SP mode)
If the light receiving level becomes saturated during close-range sensing or when sensing
transparent or minute objects, you can adjust the light emitting amount of the sensor to
stabilize sensing without needing to change the response time. Sensing that previously
required the response time or bers to be changed can now be set much more easily using
this function.
Light-emitting amount selection FX-301 FX-301-HS FX-305
Level 4
Level 3
Level 2
Level 1
OFF
Light emitting
amount
changed
[Stable sensing]
A,
B,
Actual digit difference: C’
[Light receiving level saturated]
A
4000
B
Upper display limit
Saturated digit
difference: D
Actual digit difference: C
Light emitting amount
can be changed
without changing
response time
APPLICATIONS
Detecting the presence or absence of labels
Detecting the presence or absence of ICs on a tray
You can set upper and lower limits for
the threshold values using the window
comparator mode and turn ON / OFF
the incident light intensity
within that limit.
Detecting the passage of small objects
The differential sensing mode will only
detect rapid changes in the amount of
light, which makes it
possible for small
objects to be
detected.
The light-emitting amount selection
function can even stabilize detection
of transparent labels that saturate the
light-receiving level.
141
Digital Fiber Sensor FX-300 SERIES
Selection
Guide
Fibers
Fiber
Ampliers
FX-500
FX-100
FX-300
FX-410
FX-311
FX-301-F7/
FX-301-F
FIBER
SENSORS
LASER
SENSORS
PHOTOELECTRIC
SENSORS
MICRO
PHOTOELECTRIC
SENSORS
AREA
SENSORS
LIGHT CURTAINS /
SAFETY
COMPONENTS
PRESSURE /
FLOW
SENSORS
INDUCTIVE
PROXIMITY
SENSORS
PARTICULAR
USE SENSORS
SENSOR
OPTIONS
SIMPLE
WIRE-SAVING
UNITS
WIRE-SAVING
SYSTEMS
MEASUREMENT
SENSORS
STATIC ELECTRICITY
PREVENTION
DEVICES
LASER
MARKERS
PLC
HUMAN MACHINE
INTERFACES
ENERGY CONSUMPTION
VISUALIZATION
COMPONENTS
FA COMPONENTS
MACHINE VISION
SYSTEMS
UV CURING
SYSTEMS
Simplied systems using new operating modes FX-305
A window comparator mode and
differential sensing mode have
been added. These modes make
it easy to carry out sensing tasks
that previously required multiple
sensors or involved complex
threshold settings.
Upper and lower limits for threshold
values can be set so that the incident light
intensity can turn on and off within those
ranges. Single output is used, so that
only one cable is required, and no PLC
processing is required either.
Tray absent Tray presentIC present
OFFOFF
Incident
light
intensity
ON
<Sensing ICs in trays>
Window comparator mode
Sensing of only sudden changes in light amounts
Only the target objects are sensed.
No need to reset the sensitivity.
Lower light amounts due to dust
Because sensing is not possible at normal
sensitivity settings, sensitivity must be reset.
ON ON
<Sensing of tiny moving objects>
Incident light intensity
Differential sensing mode
Equipped with 5 types timers FX-305
The FX-305 includes the same ON-delay / OFF-delay / ONE SHOT timer
as the FX-301(-HS), as well as an ON-delay • OFF-delay timer and an
ON-delay • ONE SHOT timer. A wide variety of timer control operations
can be carried out by these ber sensors alone.
ON-delay
OFF
ON
OFF
ON
OFF
ON
T1
Time chart For L-ON
Sensing
condition
ONE SHOT
ON-delay
OFF-delay
ON-delay
ONE SHOT
Beam-
interrupted
Beam-
received
OFF-delay
OFF
ON
OFF
ON
T1
T1
T2
T2
T1
T1
T1T1
Timer period
Output 1: 0.5 to 9,999 ms (variable)
Output 2: 0.5 to 500 ms (variable)
Even beginners can quickly learn how to use the MODE NAVI All models
MODE NAVI uses six
indicators to display the
amplier’s basic operations.
The current operating mode
can be conrmed at a glance,
so even a rst time user can
easily operate the amplier
without becoming confused.
RUN
TEACH
ADJ
RUN
TEACH
ADJ
RUN
TEACH
ADJ
L/D
TIMER
L/D
TIMER
L/D
TIMER
PRO
PRO
PRO
RUN
ADJ
TEACH
L / D ON
TIMER
PRO
This is the sensing mode.
Incident light level is displayed
in the digital display.
This mode is for setting
the threshold value.
In this mode, the threshold
value, once set, may be
fine-tuned.
This mode allows the selection
of output operation as either
Light-ON or Dark-ON.
This mode permits the
choice of using or not
using the timer.
This mode allows the selection of further
advanced functions, such as the copying of
individual settings and the memory functions.
Easy conrming of threshold value settings FX-301 FX-301-HS FX-305
The threshold value can be conrmed by turning the jog
switch even during RUN mode.
Jog switch is turned
Right: Output 2 for
FX-305
The threshold value is displayed
Left: FX-301(-HS)
Output 1 for FX-305
Digital Fiber Sensor FX-300 SERIES
142
Selection
Guide
Fibers
Fiber
Ampliers
FX-500
FX-100
FX-300
FX-410
FX-311
FX-301-F7/
FX-301-F
FIBER
SENSORS
LASER
SENSORS
PHOTOELECTRIC
SENSORS
MICRO
PHOTOELECTRIC
SENSORS
AREA
SENSORS
LIGHT CURTAINS /
SAFETY
COMPONENTS
PRESSURE /
FLOW
SENSORS
INDUCTIVE
PROXIMITY
SENSORS
PARTICULAR
USE SENSORS
SENSOR
OPTIONS
SIMPLE
WIRE-SAVING
UNITS
WIRE-SAVING
SYSTEMS
MEASUREMENT
SENSORS
STATIC ELECTRICITY
PREVENTION
DEVICES
LASER
MARKERS
PLC
HUMAN MACHINE
INTERFACES
ENERGY CONSUMPTION
VISUALIZATION
COMPONENTS
FA COMPONENTS
MACHINE VISION
SYSTEMS
UV CURING
SYSTEMS
The use of only two switches makes for very simple operations All models
Only two switches, the large
jog switch and the large MODE
key, are required for operation.
You can operate it simply by
the 3 steps shown on the right.
Large MODE key Large jog switch
Pressing the switch selects
or cancels the operating
mode
Moving the switch
from side to side
allows items to be
selected
2 3
Pressing the
switch then
confirms the
selected setting
1
A quick-connection cable saves wiring and
work-hours
Connector type
One unit can be used as either a main unit or sub unit
The amplier unit can be used as either a main unit
or a sub unit. This feature allows for easy mounting in
the side-by-side conguration. The main and sub unit
functions are distinguished only by the proper use of the
main cable and the sub cable.
Moreover, inventory management and maintenance is
simplied.
An optical communication function allows up to *16 sensors
to be adjusted simultaneously
FX-301
FX-305
The optical communication function allows the data that is
currently set to be copied and saved all at once for all ampliers
connected together from the right side. This greatly reduces
troublesome setup tasks and makes setup much smoother. In
addition, troublesome adjustment operations at times such as
when replacing
sensors can also be
carried out easily
and data can also be
copied and stored
using the optical
communication
function.
Single copy & save operation for all amplifiers
* Use the optical communication function for only the same types of sensors. Furthermore,
the FX-301-HS is not equipped with optical communication function capability.
Settings can be entered directly using numerical input
All models
Every function can be directly set merely by the input
of a four digit code (numbers) from the code table. This
convenient feature is easy to set up. In the event that
settings are accidentally changed at the operating site,
merely entering the correct code can restore the original
settings. This results in easy and quick maintenance.
First digit: Settings for response time and hysteresis
Second digit: Settings for L/D ON and display mode
Fourth digit: Timer period settings
Third digit: Settings for Adjust lock and timer
Identical part numbers eliminate
the need for costly inventory
management labor
Sub cable
Main cable
Main cable (4-core)
CN-74-C
Sub cable (2-core)
CN-72-C
FX-305
Main cable (3-core)
CN-73-C
Sub cable (1-core)
CN-71-C
FX-301(-HS)
FX-301B/G/H
Upper communication unit for digital sensor
SC-GU1-485
We now offer remote maintenance for digital sensors!
The communication unit enables inputs to the digital ber
sensors (such as teaching and data bank switching) to
be carried out via a PLC or a personal computer, and
also allows conrming of the incident light intensity an
output status for the ber sensors. This greatly improves
workability during equipment starting up and maintenance.
Communication unit improves equipment starting up and maintenance FX-301
FX-305
External input unit for digital sensor FX-CH2
Teaching and changing settings can be performed
by using the PLC and touch panel.
Various settings and switching of up to 16 units of
digital ber sensors can be accomplished at once
without operating the actual sensors themselves, but
via external signals, such as the PLC, touch panel, and
push buttons.
Refer to our website for details
Batch teaching
Key lock setting
Batch loading / saving of
the data bank
<Main functions>
RS-485
communication
PLC
Compatible with all PLCs equipped
with RS-485 compatible units
FX-301(P)
FX-305(P)
SC-GU1-485
Sensor incident light intensity
Sensor settings verication
Sensor output status
Threshold value settings, etc.
<Communicable commands>
Refer to SC-GU1-485 pages for details
143
Digital Fiber Sensor FX-300 SERIES
Selection
Guide
Fibers
Fiber
Ampliers
FX-500
FX-100
FX-300
FX-410
FX-311
FX-301-F7/
FX-301-F
FIBER
SENSORS
LASER
SENSORS
PHOTO-
ELECTRIC
SENSORS
MICRO
PHOTO-
ELECTRIC
SENSORS
AREA
SENSORS
LIGHT
CURTAINS /
SAFETY
COMPONENTS
PRESSURE /
FLOW
SENSORS
INDUCTIVE
PROXIMITY
SENSORS
PARTICULAR
USE
SENSORS
SENSOR
OPTIONS
SIMPLE
WIRE-SAVING
UNITS
WIRE-SAVING
SYSTEMS
MEASURE-
MENT
SENSORS
STATIC
ELECTRICITY
PREVENTION
DEVICES
LASER
MARKERS
PLC
HUMAN
MACHINE
INTERFACES
ENERGY
CONSUMPTION
VISUALIZATION
COMPONENTS
FA
COMPONENTS
MACHINE
VISION
SYSTEMS
UV
CURING
SYSTEMS
Ampliers Quick-connection cable is not supplied with the amplier. Please order it separately.
Type Appearance Model No.
Emitting element
Output Quick-connection cables
Type
Model No. Length
Standard type
FX-301
Red LED
NPN open-collector transistor
Main cable (3-core)
CN-73-C1 1 m 3.281 ft
FX-301P PNP open-collector transistor
CN-73-C2 2 m 6.562 ft
FX-301B
Blue LED
NPN open-collector transistor
FX-301BP PNP open-collector transistor
CN-73-C5 5 m 16.404 ft
FX-301G
Green LED
NPN open-collector transistor
FX-301GP PNP open-collector transistor
Sub cable (1-core)
CN-71-C1 1 m 3.281 ft
FX-301H
Infrared LED
NPN open-collector transistor
CN-71-C2 2 m 6.562 ft
FX-301HP PNP open-collector transistor
High-speed
type
FX-301-HS
Red LED
NPN open-collector transistor
CN-71-C5 5 m 16.404 ft
FX-301P-HS PNP open-collector transistor
High-function type
FX-305
Red LED
NPN open-collector transistor
Main cable (4-core)
CN-74-C1 1 m 3.281 ft
CN-74-C2 2 m 6.562 ft
CN-74-C5 5 m 16.404 ft
FX-305P PNP open-collector transistor
Sub cable (2-core)
CN-72-C1 1 m 3.281 ft
CN-72-C2 2 m 6.562 ft
CN-72-C5 5 m 16.404 ft
ORDER GUIDE
Digital Fiber Sensor FX-300 SERIES
144
Selection
Guide
Fibers
Fiber
Ampliers
FX-500
FX-100
FX-300
FX-410
FX-311
FX-301-F7/
FX-301-F
FIBER
SENSORS
LASER
SENSORS
PHOTO-
ELECTRIC
SENSORS
MICRO
PHOTO-
ELECTRIC
SENSORS
AREA
SENSORS
LIGHT
CURTAINS /
SAFETY
COMPONENTS
PRESSURE /
FLOW
SENSORS
INDUCTIVE
PROXIMITY
SENSORS
PARTICULAR
USE
SENSORS
SENSOR
OPTIONS
SIMPLE
WIRE-SAVING
UNITS
WIRE-SAVING
SYSTEMS
MEASURE-
MENT
SENSORS
STATIC
ELECTRICITY
PREVENTION
DEVICES
LASER
MARKERS
PLC
HUMAN
MACHINE
INTERFACES
ENERGY
CONSUMPTION
VISUALIZATION
COMPONENTS
FA
COMPONENTS
MACHINE
VISION
SYSTEMS
UV
CURING
SYSTEMS
ORDER GUIDE
Quick-connection cables
For FX-301(-HS)/B/G/H Quick-connection cable is not supplied with the amplier. Please order it separately.
Type Model No. Description
Main cable
(3-core)
CN-73-C1
Length: 1 m 3.281 ft
0.2 mm2 3-core cabtyre cable, with connector
on one end
Cable outer diameter: ø3.3 mm ø0.130 in
CN-73-C2
Length: 2 m 6.562 ft
CN-73-C5
Length: 5 m 16.404 ft
Sub cable
(1-core)
CN-71-C1
Length: 1 m 3.281 ft
0.2 mm2 1-core cabtyre cable, with connector
on one end
Cable outer diameter: ø3.3 mm ø0.130 in
CN-71-C2
Length: 2 m 6.562 ft
CN-71-C5
Length: 5 m 16.404 ft
Main cable
• CN-73-C□
Sub cable
• CN-71-C□
For FX-305 Quick-connection cable is not supplied with the amplier. Please order it separately.
Type Model No. Description
Main cable
(4-core)
CN-74-C1
Length: 1 m 3.281 ft
0.2 mm2 4-core cabtyre cable, with connector
on one end
Cable outer diameter: ø3.3 mm ø0.130 in
CN-74-C2
Length: 2 m 6.562 ft
CN-74-C5
Length: 5 m 16.404 ft
Sub cable
(2-core)
CN-72-C1
Length: 1 m 3.281 ft
0.2 mm2 2-core cabtyre cable, with connector
on one end
Cable outer diameter: ø3.3 mm ø0.130 in
CN-72-C2
Length: 2 m 6.562 ft
CN-72-C5
Length: 5 m 16.404 ft
Main cable
• CN-74-C□
Sub cable
• CN-72-C□
End plates End plates are not supplied with the amplier. Please order them separately when the ampliers are mounted in cascade.
Appearance Model No. Description
MS-DIN-E
When cascading multiple ampliers, or when it
moves depending on the way it is installed on a
DIN rail, these end plates clamp ampliers into
place on both sides. Make sure to use end plates
when cascading multiple ampliers together.
Two pcs. per set
Designation Model No. Description
Amplier
mounting bracket
MS-DIN-2 Mounting bracket for amplier
Fiber amplier
protection seal FX-MB1
10 sets of 2 communication window seals and 1 connector seal
Communication window seal:
It prevents malfunction due to transmission signal from another
amplier, as well as, prevents effect on another amplier.
Connector seal:
It prevents contact of any metal, etc., with the pins of the quick-
connection cable.
Amplier mounting bracket
• MS-DIN-2
Fiber amplier protection seal
• FX-MB1
Connector seal
Communication
window seal
Note: Fiber amplier protection seals are supplied with the FX-301(P) and FX-305(P).
OPTIONS
145
Digital Fiber Sensor FX-300 SERIES
Selection
Guide
Fibers
Fiber
Ampliers
FX-500
FX-100
FX-300
FX-410
FX-311
FX-301-F7/
FX-301-F
FIBER
SENSORS
LASER
SENSORS
PHOTO-
ELECTRIC
SENSORS
MICRO
PHOTO-
ELECTRIC
SENSORS
AREA
SENSORS
LIGHT
CURTAINS /
SAFETY
COMPONENTS
PRESSURE /
FLOW
SENSORS
INDUCTIVE
PROXIMITY
SENSORS
PARTICULAR
USE
SENSORS
SENSOR
OPTIONS
SIMPLE
WIRE-SAVING
UNITS
WIRE-SAVING
SYSTEMS
MEASURE-
MENT
SENSORS
STATIC
ELECTRICITY
PREVENTION
DEVICES
LASER
MARKERS
PLC
HUMAN
MACHINE
INTERFACES
ENERGY
CONSUMPTION
VISUALIZATION
COMPONENTS
FA
COMPONENTS
MACHINE
VISION
SYSTEMS
UV
CURING
SYSTEMS
FX-301 / FX-305 (Red LED type) sensing range (Note 1) The FX-305 and FX-301(-HS) have different sensing modes.
FX-305: H-SP, FAST, STD, STDF, LONG, U-LG (no S-D mode)
FX-301(-HS): S-D, H-SP (Note 1), FAST, STD, LONG (no STDF or U-LG mode)
Thru-beam type (one pair set)
Model No.
Sensing range (mm in) (Note 2)
Dimensions
Red LED
U-LG LONG STDF STD FAST H-SP S-D
FT-140
19,600 771.654 (Note 3) 19,600 771.654 (Note 3) 19,600 771.654 (Note 3)
16,000 629.921 16,000 629.921 8,700 342.520 8,700 342.520 P.51
FT-30 450 17.717 310 12.205 210 8.268 150 5.906 110 4.331 60 2.362 60 2.362 P.51
FT-31 440 17.323 290 11.417 200 7.874 142 5.591 105 4.134 58 2.283 49 1.929 P.51
FT-31S 440 17.323 290 11.417 200 7.874 140 5.512 100 3.937 55 2.165 49 1.929 P.51
FT-31W 300 11.811 230 9.055 130 5.118 100 3.937 65 2.559 30 1.181 30 1.181 P.51
FT-40 1,300 51.181 900 35.433 600 23.622 450 17.717 330 12.992 180 7.087 180 7.087 P.51
FT-42 1,100 43.307 800 31.496 550 21.654 400 15.748 285 11.220 160 6.299 150 5.906 P.51
FT-42S 1,100 43.307 800 31.496 550 21.654 400 15.748 285 11.220 160 6.299 150 5.906 P.51
FT-42W 1,000 39.370 710 27.953 460 18.110 330 12.992 240 9.449 130 5.118 130 5.118 P.51
FT-43 1,900 74.803 1,400 55.118 800 31.496 610 24.016 440 17.323 240 9.449 250 9.843 P.51
FT-45X
1,600 62.992 (Note 3)
1,100 43.307 780 30.709 570 22.441 410 16.142 230 9.055 230 9.055 P.52
FT-A11
3,600 141.732 (Note 3) 3,600 141.732 (Note 3) 3,600 141.732 (Note 3)
2,700 106.299 1,800 70.866 1,100 43.307 1,000 39.370 P.52
FT-A11W
3,600 141.732 (Note 3) 3,600 141.732 (Note 3) 3,600 141.732 (Note 3)
3,100 122.047 2,300 90.551 1,200 47.244 1,200 47.244 P.52
FT-A32
3,600 141.732 (Note 3) 3,600 141.732 (Note 3) 3,600 141.732 (Note 3) 3,600 141.732 (Note 3) 3,600 141.732 (Note 3)
2,900 114.173 2,900 114.173 P.52
FT-A32W
3,600 141.732 (Note 3) 3,600 141.732 (Note 3) 3,600 141.732 (Note 3) 3,600 141.732 (Note 3) 3,600 141.732 (Note 3)
2,000 78.740 2,100 82.677 P.52
FT-AL05 760 29.921 680 26.772 340 13.386 330 12.992 230 9.055 130 5.118 130 5.118 P.52
FT-E13 20 0.787 13 0.512 9 0.354 6 0.236 5 0.197 2 0.079 2 0.079 P.52
FT-E23 95 3.740 65 2.559 42 1.654 31 1.220 22 0.866 12 0.472 12 0.472 P.52
FT-H13-FM2 1,200 47.244 880 34.646 550 21.654 440 17.323 300 11.811 150 5.906 155 6.102 P.52
FT-H20-J20-S (Note 4)
530 20.866 390 15.354 225 8.858 200 7.874 140 5.512 60 2.362 60 2.362 P.53
FT-H20-J30-S (Note 4)
530 20.866 390 15.354 225 8.858 200 7.874 140 5.512 60 2.362 60 2.362 P.53
FT-H20-J50-S (Note 4)
530 20.866 390 15.354 225 8.858 200 7.874 140 5.512 60 2.362 60 2.362 P.53
FT-H20-M1 750 29.528 550 21.654 320 12.598 280 11.024 200 7.874 85 3.346 90 3.543 P.53
FT-H20-VJ50-S (Note 4)
840 33.071 550 21.654 370 14.567 280 11.024 200 7.874 90 3.543 90 3.543 P.53
FT-H20-VJ80-S (Note 4)
840 33.071 550 21.654 370 14.567 280 11.024 200 7.874 90 3.543 90 3.543 P.53
FT-H20W-M1 420 16.535 310 12.205 180 7.087 140 5.512 100 3.937 40 1.575 50 1.969 P.53
FT-H30-M1V-S (Note 5)
350 13.78 250 9.843 150 5.906 125 4.921 90 3.543 50 1.969 40 1.575 P.53
FT-H35-M2 750 29.528 550 21.654 330 12.992 280 11.024 200 7.874 85 3.346 90 3.543 P.53
FT-H35-M2S6 750 29.528 550 21.654 330 12.992 280 11.024 200 7.874 85 3.346 90 3.543 P.53
FT-HL80Y
3,500 137.795 (Note 3) 3,500 137.795 (Note 3)
1,800 70.866 1,350 53.150 900 35.433 450 17.717 480 18.898 P.53
FT-KS40
3,600 141.732 (Note 3) 3,600 141.732 (Note 3) 3,600 141.732 (Note 3)
2,700 106.299 1,900 74.803 1,000 39.370 850 33.465 P.54
FT-KV26 800 31.496 710 27.953 340 13.386 310 12.205 20 0.787 120 4.724 120 4.724 P.54
FT-KV40
3,600 141.732 (Note 3) 3,600 141.732 (Note 3)
3,200 125.984 2,500 98.425 1,800 70.866 1,000 39.370 1,000 39.370 P.54
FT-KV40W
3,600 141.732 (Note 3) 3,600 141.732 (Note 3)
3,200 125.984 2,000 78.740 1,400 55.118 790 31.102 810 31.890 P.54
FT-L80Y 3,500 137.795 3,500 137.795 2,000 78.740 1,500 59.055 1,000 39.370 500 19.685 530 20.866 P.54
Fibers are listed in alphabetic order. Refer to p.5~ “Fiber Selection” for details of each ber.
LIST OF FIBERS
Notes: 1) Please contact our ofce about the sensing ranges for FX-301-HS in H-SP mode.
2) Note that the sensing range of the free-cut type ber may be reduced by 20 % max. depending upon how the ber is cut.
3) The ber cable length practically limits the sensing range.
4) Heat-resistant joint bers and ordinary-temperature bers (FT-42) are sold as a set.
5) Sold as a set comprising vacuum type ber + photo-terminal (FV-BR1) + ber at atmospheric side (FT-J8).
Digital Fiber Sensor FX-300 SERIES
146
Selection
Guide
Fibers
Fiber
Ampliers
FX-500
FX-100
FX-300
FX-410
FX-311
FX-301-F7/
FX-301-F
FIBER
SENSORS
LASER
SENSORS
PHOTO-
ELECTRIC
SENSORS
MICRO
PHOTO-
ELECTRIC
SENSORS
AREA
SENSORS
LIGHT
CURTAINS /
SAFETY
COMPONENTS
PRESSURE /
FLOW
SENSORS
INDUCTIVE
PROXIMITY
SENSORS
PARTICULAR
USE
SENSORS
SENSOR
OPTIONS
SIMPLE
WIRE-SAVING
UNITS
WIRE-SAVING
SYSTEMS
MEASURE-
MENT
SENSORS
STATIC
ELECTRICITY
PREVENTION
DEVICES
LASER
MARKERS
PLC
HUMAN
MACHINE
INTERFACES
ENERGY
CONSUMPTION
VISUALIZATION
COMPONENTS
FA
COMPONENTS
MACHINE
VISION
SYSTEMS
UV
CURING
SYSTEMS
FX-301 / FX-305 (Red LED type) sensing range (Note 1) The FX-305 and FX-301(-HS) have different sensing modes.
FX-305: H-SP, FAST, STD, STDF, LONG, U-LG (no S-D mode)
FX-301(-HS): S-D, H-SP (Note 1), FAST, STD, LONG (no STDF or U-LG mode)
Thru-beam type (one pair set)
Model No.
Sensing range (mm in) (Note 2)
Dimensions
Red LED
U-LG LONG STDF STD FAST H-SP S-D
FT-R31 340 13.386 290 11.417 150 5.906 130 5.118 95 3.740 49 1.929 49 1.929 P.54
FT-R40 1,000 39.370 710 27.953 470 18.504 330 12.992 240 9.449 130 5.118 130 5.118 P.54
FT-R41W 1,000 39.370 710 27.953 460 18.110 330 12.992 240 9.449 130 5.118 130 5.118 P.54
FT-R42W 2,800 110.236 1,600 62.992 890 35.039 770 30.315 560 22.047 310 12.205 320 12.598 P.54
FT-R43 1,000 39.370 710 27.953 450 17.717 290 11.417 210 8.268 110 4.331 110 4.331 P.54
FT-R44Y 1,000 39.370 710 27.958 450 17.717 290 11.417 210 8.268 110 4.330 110 4.330 P.55
FT-R60Y 2,650 104.330 1,800 70.866 1,200 47.244 830 32.677 610 24.016 335 13.189 350 13.780 P.55
FT-S11 100 3.937 80 3.150 50 1.969 31 1.220 22 0.866 13 0.512 14 0.551 P.55
FT-S20 450 17.717 310 12.205 210 8.268 150 5.906 110 4.331 60 2.362 60 2.362 P.55
FT-S21 440 17.323 290 11.417 200 7.874 142 5.591 105 4.134 58 2.283 49 1.929 P.55
FT-S21W 300 11.811 230 9.055 130 5.118 100 3.937 65 2.559 30 1.181 30 1.181 P.55
FT-S30 1,300 51.181 900 35.433 600 23.622 450 17.717 330 12.992 180 7.087 180 7.087 P.55
FT-S31W 1,000 39.370 710 27.953 460 18.110 330 12.992 240 9.449 130 5.118 130 5.118 P.55
FT-S32 3,600 141.732 2,400 94.488 1,500 59.055 1,100 43.307 840 33.071 460 18.110 510 20.079 P.55
FT-V23 590 23.228 380 14.961 270 10.630 170 6.693 125 4.921 60 2.362 63 2.480 P.55
FT-V24W 120 4.724 90 3.543 55 2.165 40 1.575 30 1.181 13 0.512 15 0.591 P.56
FT-V25 310 12.205 200 7.874 130 5.118 90 3.543 60 2.362 35 1.378 35 1.378 P.56
FT-V30 620 24.409 420 16.535 270 10.630 200 7.874 140 5.512 70 2.756 70 2.756 P.56
FT-V40
3,600 141.732 (Note 3) 3,600 141.732 (Note 3)
1,600 62.992 1,700 66.929 1,200 47.244 680 26.772 690 27.165 P.56
FT-V80Y 1,000 39.370 800 31.496 500 19.685 400 15.748 280 11.024 120 4.724 140 5.512 P.56
FT-Z20HBW 400 15.748 290 11.417 160 6.299 130 5.118 90 3.543 50 1.969 50 1.969 P.56
FT-Z20W 830 32.677 570 22.441 370 14.567 250 9.843 180 7.087 90 3.543 90 3.543 P.56
FT-Z30 2,600 102.362 1,900 74.803 1,100 43.307 850 33.465 620 24.409 330 12.992 340 13.386 P.56
FT-Z30E
3,600 141.732 (Note 3)
3,100 122.047 2,100 82.677 1,600 62.992 1,100 43.307 650 25.591 670 26.378 P.56
FT-Z30EW
3,600 141.732 (Note 3)
2,700 106.299 1,400 55.118 1,200 47.244 900 35.433 500 19.685 500 19.685 P.57
FT-Z30H
3,600 141.732 (Note 3)
3,100 122.047 2,200 86.614 1,600 62.992 1,100 43.307 650 25.591 670 26.378 P.57
FT-Z30HW
3,600 141.732 (Note 3)
3,100 122.047 2,200 86.614 1,500 59.055 1,000 39.370 590 23.228 610 24.016 P.57
FT-Z30W 2,000 78.740 1,400 55.118 890 35.039 640 25.197 460 18.110 250 9.843 260 10.236 P.57
FT-Z40HBW 1,000 39.370 710 27.953 460 18.110 330 12.992 240 9.449 130 5.118 130 5.118 P.57
FT-Z40W 1,900 74.803 1,300 51.181 900 35.433 630 24.803 460 18.110 240 9.449 260 10.236 P.57
FT-Z802Y 3,500 137.795 3,500 137.795 3,000 118.110 1,500 59.055 1,000 39.370 500 19.685 530 20.866 P.57
Fibers are listed in alphabetic order. Refer to p.5~ “Fiber Selection” for details of each ber.
Notes: 1) Please contact our ofce about the sensing ranges for FX-301-HS in H-SP mode.
2) Note that the sensing range of the free-cut type ber may be reduced by 20 % max. depending upon how the ber is cut.
3) The ber cable length practically limits the sensing range.
LIST OF FIBERS
147
Digital Fiber Sensor FX-300 SERIES
Selection
Guide
Fibers
Fiber
Ampliers
FX-500
FX-100
FX-300
FX-410
FX-311
FX-301-F7/
FX-301-F
FIBER
SENSORS
LASER
SENSORS
PHOTO-
ELECTRIC
SENSORS
MICRO
PHOTO-
ELECTRIC
SENSORS
AREA
SENSORS
LIGHT
CURTAINS /
SAFETY
COMPONENTS
PRESSURE /
FLOW
SENSORS
INDUCTIVE
PROXIMITY
SENSORS
PARTICULAR
USE
SENSORS
SENSOR
OPTIONS
SIMPLE
WIRE-SAVING
UNITS
WIRE-SAVING
SYSTEMS
MEASURE-
MENT
SENSORS
STATIC
ELECTRICITY
PREVENTION
DEVICES
LASER
MARKERS
PLC
HUMAN
MACHINE
INTERFACES
ENERGY
CONSUMPTION
VISUALIZATION
COMPONENTS
FA
COMPONENTS
MACHINE
VISION
SYSTEMS
UV
CURING
SYSTEMS
LIST OF FIBERS
Reective type
FX-301 / FX-305 (Red LED type) sensing range (Note 1) The FX-305 and FX-301(-HS) have different sensing modes.
FX-305: H-SP, FAST, STD, STDF, LONG, U-LG (no S-D mode)
FX-301(-HS): S-D, H-SP (Note 1), FAST, STD, LONG (no STDF or U-LG mode)
Model No.
Sensing range (mm in) (Note 2, 3) / Description
Dimensions
Red LED
U-LG LONG STDF STD FAST H-SP S-D
FD-30 170 6.693 110 4.331 70 2.756 50 1.969 40 1.575 20 0.787 18 0.709 P.59
FD-31 150 5.906 95 3.740 63 2.480 45 1.772 35 1.378 17 0.669 16 0.630 P.59
FD-31W 60 2.362 40 1.575 30 1.181 20 0.787 15 0.591 80.315 10 0.394 P.59
FD-32G 210 8.268 120 4.724 100 3.937 60 2.362 42 1.654 20 0.787 20 0.787 P.59
FD-32GX 240 9.449 140 5.512 100 3.937 70 2.756 50 1.969 25 0.984 25 0.984 P.59
FD-40 170 6.693 110 4.331 70 2.756 50 1.969 40 1.575 20 0.787 18 0.709 P.59
FD-41 150 5.906 95 3.740 63 2.480 45 1.772 35 1.378 17 0.669 16 0.630 P.59
FD-41S 150 5.906 95 3.740 63 2.480 45 1.772 35 1.378 17 0.669 16 0.630 P.59
FD-41SW 60 2.362 40 1.575 30 1.181 20 0.787 15 0.591 8 0.315 10 0.394 P.59
FD-41W 300 11.811 220 8.661 140 5.512 95 3.740 70 2.756 35 1.378 40 1.575 P.59
FD-42G 210 8.268 120 4.724 100 3.937 60 2.362 42 1.654 20 0.787 20 0.787 P.60
FD-42GW 160 6.299 85 3.346 70 2.756 35 1.378 25 0.984 13 0.512 14 0.551 P.60
FD-60 500 19.685 350 13.780 240 9.449 160 6.299 130 5.118 70 2.756 70 2.756 P.60
FD-61 440 17.323 320 12.598 205 8.071 145 5.709 105 4.134 65 2.559 60 2.362 P.60
FD-61G 460 18.110 200 7.874 210 8.268 90 3.543 65 2.559 35 1.378 40 1.575 P.60
FD-61S 440 17.323 320 12.598 205 8.071 145 5.709 105 4.134 60 2.362 60 2.362 P.60
Notes: 1) Please contact our ofce about the sensing ranges for FX-301-HS in H-SP mode.
2) Note that the sensing range of the free-cut type ber may be reduced by 20 % max. depending upon how the ber is cut.
3) The sensing range is specied for white non-glossy paper.
Fibers are listed in alphabetic order. Refer to p.5~ “Fiber Selection” for details of each ber.
Sensing range when using in combination with FR-Z50HW reector (Optional)
Note: The sensing range is the possible setting range for the reector. The ber can detect an object less than setting range for the reector. However, note that if
there are any white or highly-reective surfaces near the ber head, reected incident light may affect the ber head. If this occurs, adjust the threshold value
of the amplier unit before use.
The sensing ranges are the value for red LED types.
Reector
Model No.
Sensing range (mm in)
FX-301 / 305 FX-301-HS
U-LG LONG STDF STD FAST S-D H-SP H-SP
RF-230
100 to 7,500
3.937 to 295.276
100 to 3,200
3.937 to 125.984
100 to 2,900
3.937 to 114.173
100 to 2,000
3.937 to 78.740
100 to 1,600
3.937 to 62.992
100 to 1,000
3.937 to 39.370
100 to 900
3.937 to 35.433
100 to 700
3.937 to 27.559
RF-220
100 to 2,400
3.937 to 94.488
100 to 2,400
3.937 to 94.488
100 to 1,900
3.937 to 74.803
100 to 1,300
3.937 to 51.181
100 to 1,000
3.937 to 39.370
100 to 600
3.937 to 23.622
100 to 570
3.937 to 22.441
100 to 350
3.937 to 13.780
RF-210
100 to 2,100
3.937 to 82.677
100 to 1,700
3.937 to 66.929
100 to 1,300
3.937 to 51.181
100 to 910
3.937 to 35.827
100 to 710
3.937 to 27.953
100 to 460
3.937 to 18.110
100 to 440
3.937 to 17.323
FX-301 / FX-305 (Red LED type) sensing range (Note 1)
Retroreective type
The FX-305 and FX-301(-HS) have different sensing modes.
FX-305: H-SP, FAST, STD, STDF, LONG, U-LG (no S-D mode)
FX-301(-HS): S-D, H-SP (Note 1), FAST, STD, LONG (no STDF or U-LG mode)
Model No.
Sensing range (mm in) (Note 2, 3)
Dimensions
Red LED
U-LG LONG STDF STD FAST H-SP S-D
FR-KZ22E
15 to 370 0.591 to 14.567 15 to 330 0.591 to 12.992 15 to 240 0.591 to 9.449 15 to 210 0.591 to 8.268 15 to 170 0.590 to 6.693 15 to 80 0.591 to 3.150 15 to 90 0.591 to 3.543
P.58
FR-KZ50E
20 to 350 0.787 to 13.780 20 to 300 0.787 to 11.811 20 to 250 0.787 to 9.843 20 to 200 0.787 to 7.874 20 to 200 0.787 to 7.874 20 to 200 0.787 to 7.874 20 to 200 0.787 to 7.874
P.58
FR-KZ50H
20 to 350 0.787 to 13.780 20 to 300 0.787 to 11.811 20 to 250 0.787 to 9.843 20 to 200 0.787 to 7.874 20 to 200 0.787 to 7.874 20 to 200 0.787 to 7.874 20 to 200 0.787 to 7.874
P.58
FR-Z50HW
100 to 920 3.937 to 36.220 100 to 810 3.937 to 31.890 100 to 660 3.937 to 25.984 100 to 580 3.937 to 22.835 100 to 490 3.937 to 19.291 100 to 340 3.937 to 13.385 100 to 270 3.937 to 10.630
P.58
Notes: 1) Please contact our ofce about the sensing ranges for FX-301-HS in H-SP mode.
2) Note that the sensing range of the free-cut type ber may be reduced by 20 % max. depending upon how the ber is cut.
The sensing range of FR-KZ22E is specied for the attached reector. The sensing range of FR-KZ50E and FR-KZ50H is specied for the attached
reector RF-003. The sensing range of FR-Z50HW is specied for the RF-13.
3) The sensing range is the possible setting range for the attached reector. The ber can detect an object less than setting range for the reector. However,
note that if there are any white or highly-reective surfaces near the ber head, reected incident light may affect the ber head. If this occurs, adjust the
threshold value of the amplier unit before use.
Fibers are listed in alphabetic order. Refer to p.5~ “Fiber Selection” for details of each ber.
Digital Fiber Sensor FX-300 SERIES
148
Selection
Guide
Fibers
Fiber
Ampliers
FX-500
FX-100
FX-300
FX-410
FX-311
FX-301-F7/
FX-301-F
FIBER
SENSORS
LASER
SENSORS
PHOTO-
ELECTRIC
SENSORS
MICRO
PHOTO-
ELECTRIC
SENSORS
AREA
SENSORS
LIGHT
CURTAINS /
SAFETY
COMPONENTS
PRESSURE /
FLOW
SENSORS
INDUCTIVE
PROXIMITY
SENSORS
PARTICULAR
USE
SENSORS
SENSOR
OPTIONS
SIMPLE
WIRE-SAVING
UNITS
WIRE-SAVING
SYSTEMS
MEASURE-
MENT
SENSORS
STATIC
ELECTRICITY
PREVENTION
DEVICES
LASER
MARKERS
PLC
HUMAN
MACHINE
INTERFACES
ENERGY
CONSUMPTION
VISUALIZATION
COMPONENTS
FA
COMPONENTS
MACHINE
VISION
SYSTEMS
UV
CURING
SYSTEMS
Model No.
Sensing range (mm in) (Note 2, 3) / Description
Dimensions
Red LED
U-LG LONG STDF STD FAST H-SP S-D
FD-61W 300 11.811 220 8.661 140 5.512 95 3.740 70 2.756 35 1.378 40 1.575 P.60
FD-62 690 27.165 480 18.898 310 12.205 220 8.661 160 6.299 85 3.346 90 3.543 P.60
FD-64X 270 10.630 200 7.874 100 3.937 85 3.346 60 2.362 35 1.378 35 1.378 P.61
FD-A16 230 9.055 200 7.874 150 5.906 150 5.906 100 3.937 45 1.772 50 1.969 P.61
FD-AL11 360 14.173 250 9.843 160 6.299 110 4.331 80 3.150 40 1.575 40 1.575 P.61
FD-E13 15 0.591 11 0.433 7 0.276 6 0.236 4 0.157 2 0.079 2 0.079 P.61
FD-E23 65 2.559 45 1.772 28 1.102 19 0.748 14 0.551 7 0.276 7 0.276 P.61
FD-EG30 60 2.362 45 1.772 25 0.984 19 0.748 14 0.551 7 0.276 7 0.276 P.61
FD-EG30S 60 2.362 45 1.772 25 0.984 19 0.748 14 0.551 7 0.276 7 0.276 P.62
FD-EG31 20 0.787 15 0.591 9 0.354 8 0.315 5 0.197 2.5 0.098 3 0.118 P.62
FD-F4 Applicable pipe diameter: Outer dia. ø6 to ø26 mm ø0.236 to ø1.024 in transparent pipe
[PFA (uorine resin) or equivalently transparent pipe, wall thickness 1 mm 0.039 in]P.62
FD-F41 Applicable pipe diameter: Outer dia. ø6 to ø26 mm ø0.236 to ø1.024 in transparent pipe
[PVC (vinyl chloride), uorine resin, polycarbonate, acrylic, glass, wall thickness 1 to 3 mm 0.039 to 0.118 in]P.62
FD-F41Y ø4 mm ø0.157 in form Protective tube: uorine resin, length 500 mm 19.685 in (cuttable)
Liquid surface not contacted: Beam received, Liquid surface contacted: Beam interrupted P.62
FD-F8Y
–––––––
P.62
FD-FA93
Applicable pipe diameter: Outer dia. ø8 mm ø0.315 in or more transparent pipe
(When used with the tying bands: ø8 to ø80 mm ø0.315 to ø3.150 in)
[PFA (uorine resin), including translucent]
Liquid absent: Beam received, Liquid present: Beam interrupted
P.62
FD-H13-FM2 410 16.142 310 12.205 200 7.874 140 5.512 100 3.937 55 2.165 47 1.850 P.63
FD-H18-L31
0 to 20 0 to 0.787 0 to 15 0 to 0.591 0 to 10 0 to 0.394 0 to 10 0 to 0.394
1 to 8 0.039 to 0.315
Cannot use
2 to 6 0.079 to 0.236
P.63
FD-H20-21 300 11.811 270 10.630 150 5.906 140 5.512 100 3.937 35 1.378 47 1.850 P.63
FD-H20-M1 300 11.811 270 10.630 150 5.906 140 5.512 100 3.937 35 1.378 47 1.850 P.63
FD-H25-L43 (Note 5)
3 to 28 0.118 to 1.102 3 to 25 0.118 to 0.984 4 to 23 0.157 to 0.906 4 to 20 0.118 to 0.787 4 to 19 0.118 to 0.748 4 to 16 0.118 to 0.630 4 to 16 0.118 to 0.630
P.63
FD-H25-L45 (Note 5)
5 to 42 0.197 to 1.654 6 to 41 0.236 to 1.614 6 to 40 0.236 to 1.575 7 to 38 0.276 to 1.496
P.63
FD-H30-KZ1V-S (Note 5,6)
20 to 300 0.787 to 11.811
20 to 200 0.787 to 7.874 20 to 150 0.787 to 5.906 25 to 130 0.984 to 5.118 30 to 100 1.181 to 3.937
Cannot use Cannot use P.64
FD-H30-L32
0 to 20 0 to 0.787 0 to 15 0 to 0.591 0 to 10 0 to 0.394 0 to 10 0 to 0.394
1 to 8 0.039 to 0.315
Cannot use
2 to 6 0.079 to 0.236
P.64
FD-H30-L32V-S (Note 5,6)
0 to 11 0 to 0.433
0 to 8 0 to 0.315
1.5 to 6 0.059 to 0.236 1.5 to 5 0.059 to 0.197
2 to 4 0.079 to 0.157
Cannot use Cannot use P.64
FD-H35-20S 190 7.480 160 6.299 80 3.150 80 3.150 57 2.244 20 0.787 26 1.024 P.64
FD-H35-M2 300 11.811 270 10.630 150 5.906 140 5.512 100 3.937 35 1.378 47 1.850 P.64
FD-H35-M2S6 300 11.811 270 10.630 150 5.906 140 5.512 100 3.937 35 1.378 47 1.850 P.64
FD-HF40Y
(Note 4)
ø4 mm ø0.157 in form Protective tube: uorine resin, length:500 mm 19.685 in (allowable cutting)
Liquid surface not contacted: Beam received, Liquid surface contacted: Beam interrupted P.64
FD-L10 (Note 5) 0 to 4.7
0 to 0.185
0 to 4.5
0 to 0.177
0 to 4.5
0 to 0.177
0 to 4
0 to 0.157
0 to 3.8
0 to 0.150
0 to 3.5
0 to 0.138
0 to 3.5
0 to 0.138
P.65
FD-L11 (Note 5) 0 to 9
0 to 0.354
0 to 8
0 to 0.315
0 to 8
0 to 0.315
0 to 7
0 to 0.906
0 to 7
0 to 0.276
0 to 6
0 to 0.236
0 to 6
0 to 0.236
P.65
FD-L12W (Note 5) 0.5 to 9
0.020 to 0.354
0.5 to 8
0.019 to 0.315
1 to 6.5
0.039 to 0.256
1 to 5.5
0.039 to 0.217
1 to 5
0.039 to 0.197
P.65
FD-L20H 1 to 29
0.039 to 1.142
2 to 23
0.079 to 0.906
3 to 17
0.118 to 0.669
4 to 14
0.157 to 0.551
4.5 to 11
0.177 to 0.433
5 to 8.5
0.196 to 0.335
4.8 to 9.5
0.188 to 0.374
P.65
FD-L21 (Note 5) 2 to 19
0.079 to 0.748
2 to 18
0.079 to 0.709
2 to 16
0.079 to 0.748
3 to 16
0.118 to 0.630
3 to 15
0.118 to 0.591
4 to 11
0.157 to 0.433
5 to 11
0.197 to 0.433
P.65
FD-L21W (Note 5)
3 to 14.5
0.118 to 0.571
3 to 14
0.118 to 0.551
4 to 14
0.157 to 0.551
6 to 12
0.236 to 0.472
7 to 12
0.276 to 0.472
P.65
FD-L22A (Note 5) 0 to 26
0 to 1.024
0 to 23
0 to 0.906
0 to 23
0 to 0.906
0 to 23
0 to 0.906
0 to 19
0 to 0.748
1 to 17
0.039 to 0.669
1 to 17
0.039 to 0.669
P.65
LIST OF FIBERS
The FX-305 and FX-301(-HS) have different sensing modes.
FX-305: H-SP, FAST, STD, STDF, LONG, U-LG (no S-D mode)
FX-301(-HS): S-D, H-SP (Note 1), FAST, STD, LONG (no STDF or U-LG mode)
Reective type
FX-301 / FX-305 (Red LED type) sensing range (Note 1)
Fibers are listed in alphabetic order. Refer to p.5~ “Fiber Selection” for details of each ber.
Notes: 1) Please contact our ofce about the sensing ranges for FX-301-HS in H-SP mode.
2) Note that the sensing range of the free-cut type ber may be reduced by 20 % max. depending upon how the ber is cut.
3) The sensing range of reective type is the value for white non-glossy paper (as for FD-H30-L32 and FD-H18-L31 50 × 50 mm 1.969 × 1.969 in glass
substrate).
4) Liquid inow prevention joint, protective tube extension joint, ber mounting joint are available. Please refer to p.38 for details.
5) The sensing range is specied for transparent glass 100 × 100 × t0.7 mm 3.937 × 3.937 × t0.028 in (FD-L21 and FD-L21W: t2 mm t0.079 in) [FD-L10:
silicon wafers 100 × 100 mm 3.937 × 3.937 in].
6) Sold as a set comprising vacuum type ber + photo-terminal (FV-BR1) + ber at atmospheric side (FT-J8).
149
Digital Fiber Sensor FX-300 SERIES
Selection
Guide
Fibers
Fiber
Ampliers
FX-500
FX-100
FX-300
FX-410
FX-311
FX-301-F7/
FX-301-F
FIBER
SENSORS
LASER
SENSORS
PHOTO-
ELECTRIC
SENSORS
MICRO
PHOTO-
ELECTRIC
SENSORS
AREA
SENSORS
LIGHT
CURTAINS /
SAFETY
COMPONENTS
PRESSURE /
FLOW
SENSORS
INDUCTIVE
PROXIMITY
SENSORS
PARTICULAR
USE
SENSORS
SENSOR
OPTIONS
SIMPLE
WIRE-SAVING
UNITS
WIRE-SAVING
SYSTEMS
MEASURE-
MENT
SENSORS
STATIC
ELECTRICITY
PREVENTION
DEVICES
LASER
MARKERS
PLC
HUMAN
MACHINE
INTERFACES
ENERGY
CONSUMPTION
VISUALIZATION
COMPONENTS
FA
COMPONENTS
MACHINE
VISION
SYSTEMS
UV
CURING
SYSTEMS
Model No.
Sensing range (mm in) (Note 2, 3) / Description
Dimensions
Red LED
U-LG LONG STDF STD FAST H-SP S-D
FD-L23 (Note 4) 0 to 30
0 to 1.181
0 to 30
0 to 1.181
0 to 30
0 to 1.181
0 to 30
0.039 to 1.181
1 to 28
0.039 to 1.102
2 to 27
0.079 to 1.063
2 to 27
0.079 to 1.063
P.65
FD-L30A (Note 4) 0 to 50
0 to 1.969
0 to 43
0 to 17.441
0 to 40
0 to 1.575
0 to 37
0 to 1.457
0 to 32
0 to 1.260
0 to 26
0 to 1.024
0 to 26
0 to 1.024
P.65
FD-L31A (Note 4) 4 to 33
0 to 13.110
4 to 33
0.157 to 1.299
5 to 32
0 to 1.260
5 to 32
0.197 to 1.260
5 to 32
0.197 to 1.259
6 to 18
0.236 to 0.709
6 to 18
0.236 to 0.709
P.65
FD-L32H (Note 4) 0 to 60
0 to 2.362
0 to 50
0 to 1.969
0 to 36
0 to 0.984
15 to 35
0.591 to 1.378
16 to 29
0.630 to 1.142
P.66
FD-R31G 160 6.299 92 3.622 75 2.953 44 1.732 32 1.260 17 0.669 17 0.669 P.66
FD-R32EG 60 2.362 45 1.772 25 0.984 19 0.748 13 0.512 70.276 70.276 P.66
FD-R33EG 17 0.669 15 0.591 80.315 60.236 40.157 20.079 20.079 P.66
FD-R34EG 51 2.008 38 1.496 21 0.827 16 0.630 11 0.433 60.236 60.236 P.66
FD-R41 230 9.055 150 5.906 100 3.937 70 2.756 50 1.969 28 1.102 28 1.102 P.66
FD-R60 310 12.205 240 9.449 170 6.693 120 4.724 90 3.543 45 1.772 45 1.772 P.66
FD-R61Y 350 13.780 230 9.055 160 6.299 110 4.330 80 3.150 45 1.772 45 1.772 P.66
FD-S21 80 3.150 50 1.969 40 1.575 25 0.984 19 0.748 90.354 90.354 P.66
FD-S30 170 6.693 110 4.331 70 2.756 50 1.969 40 1.575 20 0.787 18 0.709 P.67
FD-S31 150 5.906 95 3.740 63 2.480 45 1.772 35 1.378 17 0.669 16 0.630 P.67
FD-S32 440 17.323 270 10.630 200 7.874 140 5.512 100 3.937 55 2.165 55 2.165 P.67
FD-S32W 300 11.811 220 8.661 140 5.512 95 3.740 70 2.756 35 1.378 40 1.575 P.67
FD-S33GW 160 6.299 85 3.346 70 2.756 35 1.378 25 0.984 13 0.512 14 0.551 P.67
FD-S60Y 410 16.142 360 14.173 250 9.843 170 6.693 120 4.724 65 2.559 70 2.756 P.67
FD-V30 80 3.150 45 1.772 30 1.181 20 0.787 15 0.591 60.236 70.276 P.67
FD-V30W 25 0.984 15 0.591 10 0.394 70.276 50.197
P.67
FD-V50 170 6.693 100 3.937 55 2.165 45 1.772 32 1.260 15 0.591 16 0.630 P.68
FD-Z20HBW 1 to 70
0.039 to 2.756
1 to 70
0.039 to 2.756
1 to 32.2
0.039 to 1.268
2 to 30
0.079 to 1.181
2.5 to 20
0.098 to 0.787
3 to 10
0.118 to 0.394
3 to 10
0.118 to 0.394
P.68
FD-Z20W 1 to 87
0.039 to 3.425
1 to 59
0.0.9 to 2.323
2 to 39
0.079 to 1.535
3 to 27
0.118 to 1.063
3 to 19
0.118 to 0.748
P.68
FD-Z40HBW 350 13.780
0.5 to 230
0.02 to 9.055
1 to 160
0.039 to 6.299
1 to 100
0.039 to 3.937
1 to 70
0.039 to 2.756
1 to 40
0.039 to 1.575
1 to 40
0.039 to 1.575
P.68
FD-Z40W 270 10.630 180 7.087 120 4.724 1 to 87
0.039 to 3.425
1 to 63
0.039 to 2.480
2.5 to 32
0.098 to 1.260
2.5 to 32
0.098 to 1.260
P.68
FD-Z50HW
10 to 870
0.394 to 34.252
10 to 540
0.394 to 21.260
10 to 400
0.394 to 15.748
10 to 250
0.393 to 9.843
10 to 190
0.394 to 7.480
15 to 100
0.196 to 3.937
15 to 100
0.591 to 3.937
P.68
LIST OF FIBERS
The FX-305 and FX-301(-HS) have different sensing modes.
FX-305: H-SP, FAST, STD, STDF, LONG, U-LG (no S-D mode)
FX-301(-HS): S-D, H-SP (Note 1), FAST, STD, LONG (no STDF or U-LG mode)
Reective type
FX-301 / FX-305 (Red LED type) sensing range (Note 1)
Fibers are listed in alphabetic order. Refer to p.5~ “Fiber Selection” for details of each ber.
Notes: 1) Please contact our ofce about the sensing ranges for FX-301-HS in H-SP mode.
2) Note that the sensing range of the free-cut type ber may be reduced by 20 % max. depending upon how the ber is cut.
3) The sensing range of reective type is the value for white non-glossy paper.
4) The sensing range is specied for transparent glass 100 × 100 × t0.7 mm 3.937 × 3.937 × t0.028 in (FD-L32H: R edge).
Digital Fiber Sensor FX-300 SERIES
150
Selection
Guide
Fibers
Fiber
Ampliers
FX-500
FX-100
FX-300
FX-410
FX-311
FX-301-F7/
FX-301-F
FIBER
SENSORS
LASER
SENSORS
PHOTO-
ELECTRIC
SENSORS
MICRO
PHOTO-
ELECTRIC
SENSORS
AREA
SENSORS
LIGHT
CURTAINS /
SAFETY
COMPONENTS
PRESSURE /
FLOW
SENSORS
INDUCTIVE
PROXIMITY
SENSORS
PARTICULAR
USE
SENSORS
SENSOR
OPTIONS
SIMPLE
WIRE-SAVING
UNITS
WIRE-SAVING
SYSTEMS
MEASURE-
MENT
SENSORS
STATIC
ELECTRICITY
PREVENTION
DEVICES
LASER
MARKERS
PLC
HUMAN
MACHINE
INTERFACES
ENERGY
CONSUMPTION
VISUALIZATION
COMPONENTS
FA
COMPONENTS
MACHINE
VISION
SYSTEMS
UV
CURING
SYSTEMS
Thru-beam type (One pair set)
Fibers are listed in alphabetic order. Refer to p.5~ for details of each ber.
Model No.
Sensing range (mm in) (Note 1)
Dimensions
FX-301B / 311B FX-301G / 311G FX-301H (Note 2)
LONG STD FAST LONG STD FAST LONG STD FAST
FT-140 8,100
318.898
4,000
157.480
3,100
122.047
5,000
196.850
2,400
94.488
1,600
62.992
3,700
145.669
2,000
78.740
1,400
55.118
P.51
FT-30 55 2.165 28 1.102 18 0.709 28 1.102 13 0.512 90.354 25 0.984 13 0.512 90.354 P.51
FT-31 50 1.969 25 0.984 16 0.630 24 0.945 12 0.472 80.315 23 0.906 11 0.433 80.315 P.51
FT-31S 50 1.969 25 0.984 16 0.630 24 0.945 12 0.472 80.315 23 0.906 11 0.433 80.315 P.51
FT-31W 31 1.220 15 0.591 10 0.394 15 0.591 80.315 50.197 18 0.709 80.315 50.197 P.51
FT-40 155 6.102 76 2.992 45 1.772 90 3.543 40 1.575 26 1.024 80 3.150 43 1.693 27 1.063 P.51
FT-42 150 5.906 75 2.953 40 1.575 80 3.150 35 1.378 24 0.945 75 2.953 40 1.575 25 0.984 P.51
FT-42S 150 5.906 75 2.953 40 1.575 70 2.756 35 1.378 24 0.945 75 2.953 40 1.575 25 0.984 P.51
FT-42W 110 4.331 50 1.969 30 1.181 56 2.205 28 1.102 20 0.787 64 2.520 32 1.260 21 0.827 P.51
FT-43 220 8.661 110 4.331 75 2.953 120 4.724 61 2.402 43 1.693 140 5.512 74 2.913 48 1.890 P.51
FT-45X 130 5.118 65 2.559 45 1.772 70 2.756 34 1.339 25 0.984 160 6.299 79 3.110 53 2.087 P.52
FT-A11 880
34.646
420
16.535
270
10.630
430
16.929
220 8.661 120
4.724
500
19.685
220 8.661 120 4.724 P.52
FT-A11W 820
32.283
420
16.535
280
11.024
460
18.110
220 8.661 140
5.512
520
20.472
240 9.449 140 5.512 P.52
FT-A32 1,800
70.866
710
27.953
400
15.748
970
38.189
320
12.598
180
7.087
910
35.827
340
13.386
150 5.906 P.52
FT-A32W 2,000
78.740
830
32.677
420
16.535
1,000
39.370
350
13.780
180
7.087
910
35.827
340
13.386
150 5.906 P.52
FT-AL05 100 3.937 48 1.890 32 1.260 56 2.205 27 1.063 18 0.709 54 2.126 27 1.063 18 0.709 P.52
FT-E13 2 0.079 10.039
10.039
20.079 10.039
P.52
FT-E23 8 0.315 40.157 30.118 40.157 20.079 10.039 10 0.394 50.197 30.118 P.52
FT-H13-FM2 72 2.835 36 1.417 26 1.024 32 1.260 16 0.630 10 0.394 70 2.756 35 1.378 25 0.984 P.52
FT-H20-J20-S (Note 3)
60 2.362 20 0.787
35 1.378
20 0.787
P.53
FT-H20-J30-S (Note 3)
60 2.362 20 0.787
35 1.378
20 0.787
P.53
FT-H20-J50-S (Note 3)
60 2.362 20 0.787
35 1.378
20 0.787
P.53
FT-H20-M1 100 3.937 50 1.969 35 1.378 50 1.969 25 0.984 18 0.709 550
21.654
280
11.024
160 6.299 P.53
FT-H20-VJ50-S
(Note 3)
85 3.346 30 1.181
50 1.969
30 1.181
P.53
FT-H20-VJ80-S
(Note 3)
85 3.346 30 1.181
50 1.969
30 1.181
P.53
FT-H20W-M1 44 1.732 22 0.866 14 0.551 22 0.866 11 0.433 70.276 220 8.661 100 3.937 70 2.756 P.53
FT-H30-M1V-S
(Note 4)
40 1.575 20 0.787
20 0.787
20 0.787
P.53
FT-H35-M2 100 3.937 50 1.969 35 1.378 50 1.969 25 0.984 18 0.709 550
21.654
280
11.024
160 6.299 P.53
FT-H35-M2S6 100 3.937 50 1.969 35 1.378 50 1.969 25 0.984 18 0.709 550
21.654
280
11.024
160 6.299 P.53
FT-HL80Y 80 3.150 40 1.575 25 0.984 110 4.331 55 2.165 40 1.575 1,100
43.307
550
21.654
350
13.780
P.53
FT-KS40 740
29.134
280
11.024
220 8.661 420
16.535
180 7.087 81 3.189 460
18.110
190 7.480 95 3.740 P.54
FT-KV26 81 3.189 36 1.417 21 0.827 44 1.732 80.315
53 2.087 19 0.748
P.54
FT-KV40 710
27.953
270
10.630
210 8.268 420
16.535
180 7.087 100 3.937 290
11.417
120 4.724 53 2.087 P.54
FT-KV40W 860
33.858
400
15.748
260
10.236
420
16.535
210 8.268 140 5.512 490
19.291
240 9.449 140 5.512 P.54
FT-L80Y 160 6.299 80 3.150 50 1.969 160 6.299 80 3.150 50 1.969 400
15.748
200 7.874 150 5.906 P.54
FT-R31 45 1.772 23 0.906 15 0.591 24 0.945 12 0.472 80.315 23 0.906 11 0.433 80.315 P.54
FT-R40 110 4.331 54 2.126 36 1.417 55 2.165 26 1.024 20 0.787 58 2.283 30 1.181 20 0.787 P.54
FT-R41W 110 4.331 50 1.969 30 1.181 56 2.205 28 1.102 20 0.787 64 2.520 32 1.260 21 0.827 P.54
FT-R42W 280
11.024
130 5.118 90 3.543 140 5.512 70 2.756 47 1.850 140 5.512 70 2.756 47 1.850 P.54
SENSING RANGE OF BLUE LED / GREEN LED / INFRARED LED
Notes: 1) Note that the sensing range of the free-cut type ber may be reduced by 20 % max. depending upon how the ber is cut.
2) Because infrared types are easily affected by humidity, please ask assistance when using them in a humid environment or in an environment with
varying humidity.
3) Heat-resistant joint bers and ordinary-temperature bers (FT-42) are sold as a set.
4) Sold as a set comprising vacuum type ber + photo-terminal (FV-BR1) + ber at atmospheric side (FT-J8).
151
Digital Fiber Sensor FX-300 SERIES
Selection
Guide
Fibers
Fiber
Ampliers
FX-500
FX-100
FX-300
FX-410
FX-311
FX-301-F7/
FX-301-F
FIBER
SENSORS
LASER
SENSORS
PHOTO-
ELECTRIC
SENSORS
MICRO
PHOTO-
ELECTRIC
SENSORS
AREA
SENSORS
LIGHT
CURTAINS /
SAFETY
COMPONENTS
PRESSURE /
FLOW
SENSORS
INDUCTIVE
PROXIMITY
SENSORS
PARTICULAR
USE
SENSORS
SENSOR
OPTIONS
SIMPLE
WIRE-SAVING
UNITS
WIRE-SAVING
SYSTEMS
MEASURE-
MENT
SENSORS
STATIC
ELECTRICITY
PREVENTION
DEVICES
LASER
MARKERS
PLC
HUMAN
MACHINE
INTERFACES
ENERGY
CONSUMPTION
VISUALIZATION
COMPONENTS
FA
COMPONENTS
MACHINE
VISION
SYSTEMS
UV
CURING
SYSTEMS
Model No.
Sensing range (mm in) (Note 1)
Dimensions
FX-301B / 311B FX-301G / 311G FX-301H (Note 2)
LONG STD FAST LONG STD FAST LONG STD FAST
FT-R43 96 3.780 50 1.969 33 1.299 53 2.087 25 0.984 17 0.669 55 2.165 27 1.063 18 0.709 P.54
FT-R44Y 96 3.780 50 1.969 33 1.299 53 2.087 25 0.984 17 0.669 55 5.165 27 1.063 18 0.709 P.55
FT-R60Y 250 9.843 120 4.724 80 3.150 140 5.512 70 2.756 50 1.969 60 2.362 90 3.543 170 6.693 P.55
FT-S11 12
0.472
5
0.197
40.157 5
0.197
2.5 0.098 1.5 0.059 21
0.827
10 0.394 70.276 P.55
FT-S20 55 2.165 28 1.102 18 0.709 28 1.102 13 0.512 90.354 25 0.984 13 0.512 90.354 P.55
FT-S21 50
1.969
25
0.984
16 0.630 24
0.945
12 0.472 80.315 23
0.906
11 0.433 80.315 P.55
FT-S21W 31
1.220
15
0.591
10 0.394 15
0.591
80.315 50.197 18
0.709
80.315 50.197 P.55
FT-S30 155 6.102 76 2.992 45 1.772 90 3.543 40 1.575 26 1.024 80 3.150 43 1.693 27 1.063 P.55
FT-S31W 110
4.331
50
1.969
30 1.181 56
2.205
28 1.102 20 0.787 64
2.520
32 1.260 21 0.827 P.55
FT-S32 420
16.535
200
7.874
130 5.118 220
8.661
100 3.937 72 2.835 210
8.268
100 3.937 67 2.638 P.55
FT-V23 65
2.559
26
1.024
18 0.709 26
1.024
13 0.512 80.315 29
1.142
13 0.512 90.354 P.55
FT-V24W 6
0.236
2
0.079
3
0.118
3
0.118
P.56
FT-V25 25
0.984
12
0.472
90.354 16
0.630
70.276 50.197 15
0.591
80.315 40.157 P.56
FT-V30 80
3.150
40
1.575
22 0.866 40
1.575
14 0.551 80.315 47
1.850
19 0.748 90.354 P.56
FT-V40 400
15.748
200
7.874
130 5.118 200
7.874
100 3.937 65 2.559 290
11.417
140 5.512 92 3.622 P.56
FT-V80Y 120 4.724 60 2.362 35 1.378 80 3.150 40 1.575 25 0.984 75 2.953 38 1.496 24 0.945 P.56
FT-Z20HBW 39
1.535
19
0.748
12 0.472 20
0.787
10 0.394 60.236 40
1.575
15 0.591 12 0.472 P.56
FT-Z20W 82
3.228
37
1.457
23 0.906 44
1.732
18 0.709 11 0.433 100
3.937
50 1.969 32 1.260 P.56
FT-Z30 120
4.724
60
2.362
40 1.575 96
3.780
45 1.772 30 1.181 140
5.512
72 2.835 47 1.850 P.56
FT-Z30E 540
21.260
250
9.843
170 6.693 270
10.630
130 5.118 91 3.583 280
11.024
140 5.512 88 3.465 P.56
FT-Z30EW 540
21.260
260
10.236
170 6.693 260
10.236
120 4.724 88 3.465 290
11.417
140 5.512 92 3.622 P.57
FT-Z30H 650
25.591
310
12.205
200 7.874 340
13.386
160 6.299 110 4.331 330
12.992
160 6.299 100 3.937 P.57
FT-Z30HW 540
21.260
260
10.236
170 6.693 260
10.236
120 4.724 88 3.465 290
11.417
140 5.512 92 3.622 P.57
FT-Z30W 83
3.268
40
1.575
25 0.984 73
2.874
36 1.417 25 0.984 100
3.937
52 2.047 34 1.339 P.57
FT-Z40HBW 110
4.331
50
1.969
30 1.181 56
2.205
28 1.102 20 0.787 64
2.520
32 1.260 21 0.827 P.57
FT-Z40W 180
7.087
90
3.543
60 2.362 90
3.543
50 1.969 35 1.378 100
3.937
50 1.969 30 1.181 P.57
FT-Z802Y 320
12.598
160 6.299 120 4.724 160 6.299 80 3.150 60 2.362 320
12.598
160 6.299 120 4.724 P.57
Thru-beam type (One pair set)
Fibers are listed in alphabetic order. Refer to p.5~ “Fiber Selection” for details of each ber.
SENSING RANGE OF BLUE LED / GREEN LED / INFRARED LED
Notes: 1) Note that the sensing range of the free-cut type ber may be reduced by 20 % max. depending upon how the ber is cut.
2) Because infrared types are easily affected by humidity, please ask assistance when using them in a humid environment or in an environment with
varying humidity.
Retroreective type
Model No.
Sensing range (mm in) (Note 1, 2)
Dimensions
FX-301B / 311B FX-301G / 311G FX-301H
LONG STD FAST LONG STD FAST LONG STD FAST
FR-KZ22E
–––––––––
P.58
FR-KZ50E
20 to 160
0.787 to 6.299
20 to 100
0.787 to 3.937
20 to 60
0.787 to 2.362
20 to 110
0.787 to 4.331
20 to 54
0.787 to 2.126
20 to 100
0.787 to 3.937
20 to 33
0.787 to 1.299
P.58
FR-KZ50H
20 to 140
0.787 to 5.512
20 to 70
0.787 to 2.76
20 to 52
0.787 to 2.047
20 to 90
0.787 to 3.543
20 to 40
0.787 to 1.575
20 to 80
0.787 to 3.150
20 to 43
0.787 to 1.693
P.58
FR-Z50HW
––––––
100 to 410
3.937 to 16.142
P.58
Notes: 1) Note that the sensing range of the free-cut type ber may be reduced by 20 % max. depending upon how the ber is cut.
2) The sensing range is the possible setting range for the attached reector. The ber can detect an object less than setting range for the reector.
However, note that if there are any white or highly-reective surfaces near the ber head, reected incident light may affect the ber head. If this occurs,
adjust the threshold value of the amplier unit before use.
Fibers are listed in alphabetic order. Refer to p.5~ “Fiber Selection” for details of each ber.
Digital Fiber Sensor FX-300 SERIES
152
Selection
Guide
Fibers
Fiber
Ampliers
FX-500
FX-100
FX-300
FX-410
FX-311
FX-301-F7/
FX-301-F
FIBER
SENSORS
LASER
SENSORS
PHOTO-
ELECTRIC
SENSORS
MICRO
PHOTO-
ELECTRIC
SENSORS
AREA
SENSORS
LIGHT
CURTAINS /
SAFETY
COMPONENTS
PRESSURE /
FLOW
SENSORS
INDUCTIVE
PROXIMITY
SENSORS
PARTICULAR
USE
SENSORS
SENSOR
OPTIONS
SIMPLE
WIRE-SAVING
UNITS
WIRE-SAVING
SYSTEMS
MEASURE-
MENT
SENSORS
STATIC
ELECTRICITY
PREVENTION
DEVICES
LASER
MARKERS
PLC
HUMAN
MACHINE
INTERFACES
ENERGY
CONSUMPTION
VISUALIZATION
COMPONENTS
FA
COMPONENTS
MACHINE
VISION
SYSTEMS
UV
CURING
SYSTEMS
Reective type
Model No.
Sensing range (mm in) (Note 1, 2) / Description
Dimensions
FX-301B / 311B FX-301G / 311G FX-301H
LONG STD FAST LONG STD FAST LONG STD FAST
FD-30 19 0.748 90.354 60.236 90.354 4.5 0.177 2.5 0.098 80.315 40.157 2.5 0.098 P.59
FD-31 18
0.709
8
0.315
5
0.197
8
0.315
40.157 2
0.079
7
0.276
3
0.118
2
0.079
P.59
FD-31W 7
0.276
4
0.157
1 to 2.5
0.039 to 0.098
5
0.197
1 to 2
0.039 to 0.079
6
0.236
3
0.118
P.59
FD-32G 22
0.866
11
0.433
8
0.315
15
0.591
60.236 4
0.157
11
0.433
6
0.236
2
0.079
P.59
FD-32GX 25
0.984
11
0.433
8
0.315
16
0.630
60.236 4
0.157
14
0.551
7
0.276
4
0.157
P.59
FD-40 19 0.748 90.354 60.236 90.354 4.5 0.177 2.5 0.098 80.315 40.157 2.5 0.098 P.59
FD-41 18
0.709
8
0.315
5
0.197
8
0.315
40.157 2
0.079
7
0.276
3
0.118
2
0.079
P.59
FD-41S 18
0.709
8
0.315
5
0.197
8
0.315
40.157 2
0.079
7
0.276
3
0.118
2
0.079
P.59
FD-41SW 9
0.354
1 to 4
0.039 to 0.157
1 to 2.5
0.039 to 0.098
1 to 4
0.039 to 0.157
1 to 2
0.039 to 0.079
6
0.236
1 to 3
0.039 to 0.118
P.59
FD-41W 32
1.260 1 to 15
0.039 to 0.591
1 to 9
0.039 to 0.354
17
0.669
1 to 7.5
0.039 to 0.295
1.5 to 4.5
0.059 to 0.177
18
0.709
1 to 9
0.039 to 0.354
1.5 to 5
0.059 to 0.197
P.59
FD-42G 22
0.866
11
0.433
8
0.315
15
0.591
60.236 4
0.157
11
0.433
6
0.236
2
0.079
P.60
FD-42GW 14
0.551
7
0.276
5
0.197
6
0.236
40.157 2
0.079
9
0.354
5
0.197
2
0.079
P.60
FD-60 55 2.165 28 1.102 18 0.709 30 1.181 15 0.591 10 0.394 30 1.181 15 0.591 10 0.394 P.60
FD-61 48
1.890
24
0.945
16
0.630
26
1.024
13 0.512 8
0.315
27
1.063
12
0.472
8
0.315
P.60
FD-61G 46
1.811
23
0.906
15
0.591
26
1.024
12 0.472 8
0.315
25
0.984
12
0.472
8
0.315
P..60
FD-61S 48
1.890
24
0.945
16
0.630
26
1.024
13 0.512 8
0.315
27
1.063
12
0.472
8
0.315
P.60
FD-61W 32
1.260
1 to 15
0.039 to 0.591
1 to 9
0.039 to 0.354
17
0.669
1 to 7.5
0.039 to 0.295
1.5 to 4.5
0.059 to 0.177
18
0.709
1 to 9
0.039 to 0.354
1.5 to 5
0.059 to 0.197
P.60
FD-62 80
3.150 1 to 40
0.039 to 1.575
1 to 27
0.039 to 1.063
1 to 42
0.039 to 1.654
1 to 21
0.039 to 0.827
1 to 14
0.039 to 0.551
54
2.126 1 to 26
0.039 to 1.024
1 to 17
0.039 to 0.669
P.60
FD-64X 32
1.260
0.5 to 16
0.020 to 0.630
0.5 to 10
0.020 to 0.394
0.5 to 16
0.020 to 0.630
0.5 to 8
0.020 to 0.315
0.5 to 5
0.020 to 0.197
27
1.063
22
0.866
14
0.551
P.61
FD-A16 19
0.748
14
0.551
20
0.787
13 0.512
18
0.709
15
0.591
P.61
FD-AL11 33
1.299
16
0.630
10
0.394
18
0.709
80.315 4.5
0.177
12
0.472
10
0.394
6
0.236
P.61
FD-E13 2
0.079
0.8
0.031
0.5
0.020
0.8
0.031
2
0.079
1
0.039
P.61
FD-E23 6
0.236
3
0.118
2
0.079
3
0.118
1.5 0.059 1
0.039
8
0.315
4
0.157
2.5
0.098
P.61
FD-EG30 6
0.236
3
0.118
2
0.079
3
0.118
1.5 0.059 1
0.039
8
0.315
4
0.157
2.5
0.098
P.61
FD-EG30S 6
0.236
3
0.118
2
0.079
3
0.118
1.5 0.059 1
0.039
8
0.315
4
0.157
2.5
0.098
P.62
FD-EG31 2
0.079
1
0.039
0.5
0.020
1
0.039
4
0.157
2
0.079
1
0.039
P.62
FD-F4
Applicable pipe diameter: Outer dia. ø6 to ø26 mm ø0.236 to ø1.024 in transparent pipe
[PFA (uorine resin) or equivalently transparent pipe, wall thickness 1 mm 0.039 in]
Liquid absent: Beam received, Liquid present: Beam interrupted
P.62
FD-F41
Applicable pipe diameter: Outer dia. ø6 to ø26 mm ø0.236 to ø1.024 in transparent pipe
[PVC (vinyl chloride), uorine resin, polycarbonate, acrylic, glass, wall thickness 1 to 3 mm 0.039 to 0.118 in]
Liquid absent: Beam received, Liquid present: Beam interrupted
P.62
FD-F41Y (Note 3) ø4 mm ø0.157 in form Protective tube: uorine resin, length 500 mm 19.685 in (cuttable)
Liquid surface not contacted: Beam received, Liquid surface contacted: Beam interrupted P.62
FD-F8Y
–––––––––
P.62
FD-FA93
Applicable pipe diameter: Outer dia. ø8 mm ø0.315 in or more transparent pipe
(When used with the tying bands: ø8 to ø80 mm ø0.315 to ø3.150 in) [PFA (uorine resin), including translucent]
Liquid absent: Beam received, Liquid present: Beam interrupted
P.62
FD-H13-FM2 20 0.787 11 0.433 70.276 20 0.787 11 0.433 70.276 25 0.984 12 0.472 80.315 P.63
FD-H18-L31
–––––––––
P.63
FD-H20-21 36 1.417 18 0.709 12 0.472 20 0.787 10 0.394 70.276 140 5.512 70 2.756 45 1.772 P.63
FD-H20-M1 36 1.417 18 0.709 12 0.472 20 0.787 10 0.394 70.276 140 5.512 70 2.756 45 1.772 P.63
FD-H25-L43 (Note 4)
–––––––––
P.63
FD-H25-L45 (Note 4)
–––––––––
P.63
Fibers are listed in alphabetic order. Refer to p.5~ “Fiber Selection” for details of each ber.
Notes: 1) Note that the sensing range of the free-cut type ber may be reduced by 20 % max. depending upon how the ber is cut.
2) The sensing range is specied for white non-glossy paper. (FP-H18-L31 50 × 50 mm 1.969 × 1.969 in. glass substrate).
3) Liquid inow prevention joint, protective tube extension joint, ber mounting joint are available. Please refer to p.38 for details.
4) The sensing range is specied for transparent glass 100 × 100 × t0.7 mm 3.937 × 3.937 × t0.028 in
SENSING RANGE OF BLUE LED / GREEN LED / INFRARED LED
153
Digital Fiber Sensor FX-300 SERIES
Selection
Guide
Fibers
Fiber
Ampliers
FX-500
FX-100
FX-300
FX-410
FX-311
FX-301-F7/
FX-301-F
FIBER
SENSORS
LASER
SENSORS
PHOTO-
ELECTRIC
SENSORS
MICRO
PHOTO-
ELECTRIC
SENSORS
AREA
SENSORS
LIGHT
CURTAINS /
SAFETY
COMPONENTS
PRESSURE /
FLOW
SENSORS
INDUCTIVE
PROXIMITY
SENSORS
PARTICULAR
USE
SENSORS
SENSOR
OPTIONS
SIMPLE
WIRE-SAVING
UNITS
WIRE-SAVING
SYSTEMS
MEASURE-
MENT
SENSORS
STATIC
ELECTRICITY
PREVENTION
DEVICES
LASER
MARKERS
PLC
HUMAN
MACHINE
INTERFACES
ENERGY
CONSUMPTION
VISUALIZATION
COMPONENTS
FA
COMPONENTS
MACHINE
VISION
SYSTEMS
UV
CURING
SYSTEMS
Reective type
Model No.
Sensing range (mm in) (Note 1, 2) / Description
Dimensions
FX-301B / 311B FX-301G / 311G FX-301H
LONG STD FAST LONG STD FAST LONG STD FAST
FD-H30-KZ1V-S (Note 3,4)
30 to 40
1.181 to 1.575
––––––––
P.64
FD-H30-L32
–––––––––
P.64
FD-H30-L32V-S (Note 3,4)
–––––––––
P.64
FD-H35-20S 22 0.866 11 0.433 70.276 12 0.472 60.236 40.157 80 3.150 40 1.575 28 1.102 P.64
FD-H35-M2 36 1.417 18 0.709 12 0.472 20 0.787 10 0.394 70.276 140 5.512 70 2.756 45 1.772 P.64
FD-H35-M2S6 36 1.417 18 0.709 12 0.472 20 0.787 10 0.394 70.276 140 5.512 70 2.756 45 1.772 P.64
FD-HF40Y (Note 5)
ø4 mm ø0.157 in form Protective tube: uorine resin, length:500 mm 19.685 in (allowable cutting)
Liquid surface not contacted: Beam received, Liquid surface contacted: Beam interrupted P.64
FD-L10 (Note 6)
0 to 3.5
0 to 0.138
0 to 3
0 to 0.118
0.5 to 2.5
0.020 to 0.098
0 to 3
0 to 0.118
1 to 2
0.039 to 0.079
0 to 3
0 to 0.118
1 to 2
0.039 to 0.079
P.65
FD-L11 (Note 6) 70.276 6.5 0.256
0.5 to 5.5
0.020 to 0.217
6.5 0.256 1 to 4
0.039 to 0.157
6.5 0.256
1 to 4.5
0.039 to 0.177
P.65
FD-L12W
(Note 6)
–––––––––
P.65
FD-L20H
4.5 to 10
0.177 to 0.394
5 to 9
0.197 to 0.354
5.5 to 8
0.217 to 0.315
5 to 9
0.197 to 0.354
5.5 to 8
0.217 to 0.315
4.9 to 8.5
0.193 to 0.335
P.65
FD-L21 (Note 6)
–––––––––
P.65
FD-L21W
(Note 6)
–––––––––
P.65
FD-L22A
(Note 6)
–––––––––
P.65
FD-L23 (Note 6)
–––––––––
P.65
FD-L30A
(Note 6)
–––––––––
P.65
FD-L31A
(Note 6)
–––––––––
P.65
FD-L32H
(Note 6)
–––––––––
P.66
FD-R31G 17 0.669 80.315 50.197 80.315 40.157 20.079 90.354 40.157 20.079 P.66
FD-R32EG 60.236 30.118 1.5 0.059 20.079 10.039
80.315 40.157 2.5 0.098 P.66
FD-R33EG 20.079 0.8 0.031 0.5 0.020 10.039
30.118 1.5 0.059
P.66
FD-R34EG 50.197 20.079 1.5 0.059 20.079 10.039
60.236 30.118 20.079 P.66
FD-R41 24 0.945
1 to 13
0.039 to 0.512
1 to 9
0.039 to0.354
1 to 15
0.039 to 0.591
1 to 8
0.039 to 0.315
3 to 6
0.118 to 0.236
14 0.551 1 to 6
0.039 to 0.236
1 to 3
0.039 to 0.118
P.66
FD-R60 42 1.654 20 0.787
0.5 to 13
0.020 to 0.512
21 0.827
0.5 to 10
0.020 to 0.394
0.5 to 7
0.020 to 0.276
27 1.063 12 0.472 80.315 P.66
FD-R61Y 36 1.417 17 0.669
0.5 to 11
0.020 to 0.433
19 0.748
0.5 to 9
0.020 to 0.354
1 to 6
0.039 to 0.236
19 0.748
0.5 to 10
0.020 to 0.394
0.5 to 6
0.020 to 0.236
P.66
FD-S21 80.315 3.5 0.138 20.079 50.197 20.079 1.3 0.051 90.354 40.157 30.118 P.66
FD-S30 19 0.749 90.354 60.236 90.354 4.5 0.177 2.5 0.098 80.315 40.157 2.5 0.098 P.67
FD-S31 18 0.709 80.315 50.197 80.315 40.157 20.079 70.276 30.118 20.079 P.67
FD-S32 48 1.890 24 0.945 16 0.630 26 1.024 13 0.512 80.315 27 1.063 12 0.472 80.315 P.67
FD-S32W 32 1.260
1 to 15
0.039 to 0.591
1 to 9
0.039 to 0.354
17 0.669
1 to 7.5
0.039 to 0.295
1.5 to 4.5
0.059 to 0.177
18 0.709 1 to 9
0.039 to 0.354
1.5 to 5
0.059 to 0.197
P.67
FD-S33GW 14 0.551 70.276 50.197 60.236 40.157 20.079 90.354 50.197 20.079 P.67
FD-S60Y 50 1.969 20 0.787
3 to 12
0.118 to 0.472
28 1.102 3 to 9
0.118 to 0.354
30 1.181
2 to 13
0.079 to 0.512
5 to 6.5
0.197 to 0.256
P.67
FD-V30 90.354
––––––––
P.67
FD-V30W
–––––––––
P.67
FD-V50 12 0.472
60.236
60.236
P.68
FD-Z20HBW
4 to 10
0.157 to 0.394
–––––
3 to 11
0.118 to 0.433
4 to 6
0.157 to 0.236
P.68
FD-Z20W
––––––
5 to 8
0.197 to 0.315
P.68
FD-Z40HBW
1 to 36
0.039 to 1.417
3 to 17
1.181 to 0.669
3 to 11
1.181 to 0.433
2 to 19
0.079 to 0.748
3 to 8
0.118 to 0.315
4 to 5
0.157 to 0.197
2 to 20
0.0787 to 0.787
3 to 10
0.118 to 0.394
4 to 5.5
0.157 to 0.217
P.68
FD-Z40W
4 to 20
0.157 to 0.787
4 to 14
0.157 to 0.551
5 to 10
0.197 to 0.394
P.68
FD-Z50HW
–––––––––
P.68
Notes: 1) The standard sensing objects of the sensing ranges vary depending on the bers.
2) Note that the sensing range of the free-cut type ber may be reduced by 20 % max. depending upon how the ber is cut.
3) The sensing range of reective type is the value for white non-glossy paper.
4) Sold as a set comprising vacuum type ber + photo-terminal (FV-BR1) + ber at atmospheric side (FT-J8).
5) Liquid inow prevention joint, protective tube extension joint, ber mounting joint are available. Please refer to p.38 for details.
6) The sensing range is specied for transparent glass 100 × 100 × t.0.07 mm 3.937 × 3.937 × t0.028 in, (FD-L32H: R-edge,
FD-L21 and FD-L21W: t2 mm t0.079 in) [FD-L10: silicon wafers 100 × 100 mm 3.937 × 3.937 in]
Fibers are listed in alphabetic order. Refer to p.5~ “Fiber Selection” for details of each ber.
SENSING RANGE OF BLUE LED / GREEN LED / INFRARED LED
Digital Fiber Sensor FX-300 SERIES
154
Selection
Guide
Fibers
Fiber
Ampliers
FX-500
FX-100
FX-300
FX-410
FX-311
FX-301-F7/
FX-301-F
FIBER
SENSORS
LASER
SENSORS
PHOTO-
ELECTRIC
SENSORS
MICRO
PHOTO-
ELECTRIC
SENSORS
AREA
SENSORS
LIGHT
CURTAINS /
SAFETY
COMPONENTS
PRESSURE /
FLOW
SENSORS
INDUCTIVE
PROXIMITY
SENSORS
PARTICULAR
USE
SENSORS
SENSOR
OPTIONS
SIMPLE
WIRE-SAVING
UNITS
WIRE-SAVING
SYSTEMS
MEASURE-
MENT
SENSORS
STATIC
ELECTRICITY
PREVENTION
DEVICES
LASER
MARKERS
PLC
HUMAN
MACHINE
INTERFACES
ENERGY
CONSUMPTION
VISUALIZATION
COMPONENTS
FA
COMPONENTS
MACHINE
VISION
SYSTEMS
UV
CURING
SYSTEMS
FIBER OPTIONS
Lens (for thru-beam type ber)
Designation Model No. Description
For thru-beam type ber
Expansion
lens
(Note 1)
FX-LE1
Increases the sensing
range by 5 times or
more.
Ambient
temperature:
60 to +350 °C
76 to +662 °F
(Note 5)
Beam dia:
ø3.6 mm
ø0.142 in
Sensing range for red LED type (mm) [Lens on both sides] (Note 2)
Mode
Fiber U-LG LONG STDF STD FAST S-D H-SP
FT-43
3,600 (Note 3) 3,600 (Note 3) 3,600 (Note 3)
2,900 2,100 1,300 1,200
FT-42
3,600 (Note 3) 3,600 (Note 3) 3,600 (Note 3) 3,600 (Note 3)
2,800 1,600 1,600
FT-45X
1,600 (Note 3) 1,600 (Note 3) 1,600 (Note 3) 1,600 (Note 3) 1,600 (Note 3) 1,600 (Note 3)
1,500
FT-R40
3,600 (Note 3) 3,600 (Note 3)
3,500 3,400 2,700 1,500 1,500
FT-H35-M2
3,500 (Note 3) 3,500 (Note 3)
2,500 2,000 1,500 750 700
FT-H20W-M1
1,600 (Note 3) 1,600 (Note 3) 1,600 (Note 3)
1,300 900 500 400
FT-H20-M1
1,600 (Note 3) 1,600 (Note 3) 1,600 (Note 3) 1,600 (Note 3)
1,100 900 600
Super-
expansion
lens
(Note 1)
FX-LE2
Tremendously
increases the sensing
range with large
diameter lenses.
Ambient
temperature:
60 to +350 °C
76 to +662 °F
(Note 5)
Beam dia:
ø9.8 mm
ø0.386 in
Sensing range for red LED type (mm) [Lens on both sides] (Note 2)
Mode
Fiber U-LG LONG STDF STD FAST S-D H-SP
FT-43
3,600 (Note 3) 3,600 (Note 3) 3,600 (Note 3) 3,600 (Note 3) 3,600 (Note 3) 3,600 (Note 3) 3,600 (Note 3)
FT-42
3,600 (Note 3) 3,600 (Note 3) 3,600 (Note 3) 3,600 (Note 3) 3,600 (Note 3) 3,600 (Note 3) 3,600 (Note 3)
FT-45X
1,600 (Note 3) 1,600 (Note 3) 1,600 (Note 3) 1,600 (Note 3) 1,600 (Note 3) 1,600 (Note 3) 1,600 (Note 3)
FT-R40
3,600 (Note 3) 3,600 (Note 3) 3,600 (Note 3) 3,600 (Note 3) 3,600 (Note 3) 3,600 (Note 3) 3,600 (Note 3)
FT-H35-M2
3,500 (Note 3) 3,500 (Note 3) 3,500 (Note 3) 3,500 (Note 3) 3,500 (Note 3) 3,500 (Note 3) 3,500 (Note 3)
FT-H20W-M1
1,600 (Note 3) 1,600 (Note 3) 1,600 (Note 3) 1,600 (Note 3) 1,600 (Note 3)
1,500
1,600 (Note 3)
FT-H20-M1
1,600 (Note 3) 1,600 (Note 3) 1,600 (Note 3) 1,600 (Note 3) 1,600 (Note 3) 1,600 (Note 3) 1,600 (Note 3)
FT-H13-FM2
3,500 (Note 3) 3,500 (Note 3) 3,500 (Note 3) 3,500 (Note 3) 3,500 (Note 3) 3,500 (Note 3) 3,500 (Note 3)
Side-view
lens FX-SV1
Beam axis is bent by
90°.
Ambient
temperature:
60 to +300 °C
76 to +572 °F
(Note 5)
Beam dia:
ø2.8 mm
ø0.110 in
Sensing range for red LED type (mm) [Lens on both sides] (Note 2)
Mode
Fiber U-LG LONG STDF STD FAST S-D H-SP
FT-43 1,900 1,200 840 580 420 250 240
FT-42 2,100 1,400 870 640 440 210 210
FT-45X
1,600 (Note 3) 1,600 (Note 3)
840 650 450 220 220
FT-H35-M2
840 550 370 280 200 90 90
FT-H20W-M1
400 310 180 140 100 50 50
FT-H20-M1
840 550 370 280 200 90 90
Expansion
lens for
vacuum
ber
(Note 1)
FV-LE1
Sensing range increases
by 4 times or more.
Ambient temperature:
60 to +350 °C
76 to +662 °F
(Note 5)
Beam dia:
ø3.6 mm
ø0.142 in
Sensing range for red LED type (mm) [Lens on both sides] (Note 2, 4)
Mode
Fiber U-LG LONG STDF STD FAST S-D H-SP
FT-H30-M1V-S
1,600 1,200 650 450 300 150 200
Vacuum
resistant
side-view
lens
(Note 1)
FV-SV2
Beam axis is bent by
90°.
Ambient temperature:
60 to +300 °C
76 to +572 °F
(Note 5)
Beam dia:
ø3.7 mm
ø0.146 in
Sensing range for red LED type (mm) [Lens on both sides] (Note 2, 4)
Mode
Fiber U-LG LONG STDF STD FAST S-D H-SP
FT-H30-M1V-S
1,600 1,200 650 450 300 150 200
Notes: 1) Be careful sure to use it only after you have adjusted it sufciently when installing the thru-beam type ber equipped with the expansion lens, as the
beam envelope becomes narrow and alignment is difcult.
2) The sensing ranges are the values for red LED type amplier. Please contact our ofce for details on sensing ranges for other types of ampliers.
3) The ber cable length practically limits the sensing range.
4) The ber cable length for the FT-H30-M1V-S is 1 m 3.281 ft. The sensing ranges in U-LG and LONG modes take into account the length of the FT-J8
atmospheric side ber.
5) Refer to p.15, p18, p.33 and p.35 for the ambient temperatures of bers to be used in combination.
Refer to p. 69~ for details of lens dimensions.
155
Digital Fiber Sensor FX-300 SERIES
Selection
Guide
Fibers
Fiber
Ampliers
FX-500
FX-100
FX-300
FX-410
FX-311
FX-301-F7/
FX-301-F
FIBER
SENSORS
LASER
SENSORS
PHOTO-
ELECTRIC
SENSORS
MICRO
PHOTO-
ELECTRIC
SENSORS
AREA
SENSORS
LIGHT
CURTAINS /
SAFETY
COMPONENTS
PRESSURE /
FLOW
SENSORS
INDUCTIVE
PROXIMITY
SENSORS
PARTICULAR
USE
SENSORS
SENSOR
OPTIONS
SIMPLE
WIRE-SAVING
UNITS
WIRE-SAVING
SYSTEMS
MEASURE-
MENT
SENSORS
STATIC
ELECTRICITY
PREVENTION
DEVICES
LASER
MARKERS
PLC
HUMAN
MACHINE
INTERFACES
ENERGY
CONSUMPTION
VISUALIZATION
COMPONENTS
FA
COMPONENTS
MACHINE
VISION
SYSTEMS
UV
CURING
SYSTEMS
FIBER OPTIONS
Lens (for reective type ber)
Notes: 1)
The sensing ranges are the values when used in combination with a red LED type amplier. Please contact our ofce for details on sensing ranges for other types of amplier.
2) Refer to p.16 or p.26 for the ambient temperatures of bers to be used in combination.
Note: Spot diameter, distance to focal point and sensing range are specied for a red LED type amplier.
Refer to p. 69~ for details of lens dimensions.
Designation Model No. Description
For reective type ber
Pinpoint
spot lens FX-MR1
Pinpoint spot of ø0.5 mm ø0.020 in. Enables detection of minute objects or small marks.
Distance to focal point: 6 ± 1 mm 0.236 ± 0.039 in
• Applicable bers: FD-42G, FD-42GW
• Ambient temperature: -40 to +70 °C -40 to +158 °F (Note)
Zoom lens FX-MR2
Screw-in
depth
Distance to
focal point
Spot
diameter
The spot diameter is adjustable from ø0.7 to ø2
mm ø0.028 to ø0.079 in according to how much
the ber is screwed in.
• Applicable bers: FD-42G, FD-42GW
• Ambient temperature: -40 to +70 °C
-40 to +158 °F (Note 2)
• Accessory: MS-EX3 (mounting bracket)
Sensing range for red LED type (Note 1)
Screw-in depth
Distance to focal point
Spot diameter
7 mm
18.5 mm approx.
ø0.7 mm
12 mm
27 mm approx.
ø1.2 mm
14 mm
43 mm approx.
ø2.0 mm
Finest spot
lens FX-MR3
Spot diameter
Distance to
focal point
Extremely ne spot of ø0.15 mm ø0.006 in
approx. achieved.
• Applicable bers:
FD-EG31, FD-EG30, FD-42G, FD-42GW,
FD-32G, FD-32GX
• Ambient temperature: -40 to +70 °C
-40 to +158 °F (Note 2)
Sensing range for red LED type (Note 1)
Fiber model No.
Distance to focal point
Spot diameter
FD-EG31 7.5 ±0.5 mm
ø0.15 mm approx.
FD-EG30 7.5 ±0.5 mm
ø0.3 mm approx.
FD-42G/42GW
FD-32G/32GX
7.5 ±0.5 mm
ø0.5 mm approx.
Finest spot
lens FX-MR6
Extremely ne spot of ø0.1 mm ø0.004 in
approx. achieved.
• Applicable bers:
FD-EG31, FD-EG30, FD-42G, FD-42GW,
FD-32G, FD-32GX
• Ambient temperature: -20 to +60 °C
-4 to +140 °F (Note 2)
Sensing range for red LED type (Note 1)
Fiber model No.
Distance to focal point
Spot diameter
FD-EG31 7 ±0.5 mm
ø
0.1 mm
approx.
FD-EG30 7 ±0.5 mm
ø
0.2 mm
approx.
FD-42G/42GW
FD-32G/32GX
7 ±0.5 mm
ø
0.4 mm
approx.
Zoom lens
side-view
type FX-MR5
Screw-in
depth
Spot diameter
Distance to
focal point
FX-MR2 is converted into a side-view type and
can be mounted in a very small space.
• Applicable bers: FD-42G, FD-42GW
• Ambient temperature: -40 to +70 °C
-40 to +158 °F (Note 2)
Sensing range for red LED type (Note 1)
Screw-in depth
Distance to focal point
Spot diameter
8 mm
13 mm approx.
ø0.5 mm
10 mm
15 mm approx.
ø0.8 mm
14 mm
30 mm approx.
ø3.0 mm
Lens (For square head M3 reective ber)
Type Spot diameter
(mm in) (Note)
Distance to
focal point
(mm in) (Note)
Lens Fiber
Shape
(mm in)Model No. Shape Emitting ber
core (mm in)Model No.
For Square head M3 reective ber
Finest spot
lens
ø0.1 ø0.004
approx.
7 ± 0.5
0.276 ± 0.020 FX-MR7
ø0.125 ø0.005 FD-R33EG
ø0.125 ø0.005 FD-EG31
ø0.15 ø0.006
approx. ø0.175 ø0.007 FD-R34EG
ø0.2 ø0.008
approx.
ø0.25 ø0.010 FD-R32EG
ø0.25 ø0.010 FD-EG30
ø0.4 ø0.016
approx.
ø0.5 ø0.020 FD-R31G
ø0.5 ø0.020 FD-32G
ø0.5 ø0.020 FD-32GX
ø0.5 ø0.020 FD-42G
ø0.5 ø0.020 FD-42GW
Type Spot diameter
(mm in) (Note)
Sensing
range
(mm in) (Note)
Lens Applicable bers
Shape
(mm in)Model No. Emitting ber
core (mm in)Model No.
For Square head M3
reective ber
Zoom lens
ø0.4 to ø2.0 ø0.016 to ø0.079 approx.
10 to 30
0.394 to1.181 FX-MR8
ø0.125 ø0.005 FD-R33EG, FD-EG31
ø0.4 to ø2.2 ø0.016 to ø0.087 approx.
ø0.175 ø0.007 FD-R34EG
ø0.5 to ø2.5 ø0.020 to ø0.098 approx.
ø0.25 ø0.010 FD-R32EG, FD-EG30
ø0.8 to ø3.5 ø0.031 to ø0.138 approx.
ø0.5 ø0.020 FD-R31G, FD-32G, FD-32GX, FD-42G, FD-42GW
Parallel
light lens
ø4.0 ø0.157 approx. 0 to 30
0 to 1.181 FX-MR9
ø0.125 ø0.005 FD-R33EG, FD-EG31
ø0.175 ø0.007 FD-R34EG
ø0.25 ø0.010 FD-R32EG, FD-EG30
ø0.5 ø0.020 FD-R31G, FD-32G, FD-32GX, FD-42G, FD-42GW
15.3
0.602
ø5 ø0.197
15
0.591
ø5 ø0.197
ø5 ø0.197
10
0.394
Digital Fiber Sensor FX-300 SERIES
156
Selection
Guide
Fibers
Fiber
Ampliers
FX-500
FX-100
FX-300
FX-410
FX-311
FX-301-F7/
FX-301-F
FIBER
SENSORS
LASER
SENSORS
PHOTO-
ELECTRIC
SENSORS
MICRO
PHOTO-
ELECTRIC
SENSORS
AREA
SENSORS
LIGHT
CURTAINS /
SAFETY
COMPONENTS
PRESSURE /
FLOW
SENSORS
INDUCTIVE
PROXIMITY
SENSORS
PARTICULAR
USE
SENSORS
SENSOR
OPTIONS
SIMPLE
WIRE-SAVING
UNITS
WIRE-SAVING
SYSTEMS
MEASURE-
MENT
SENSORS
STATIC
ELECTRICITY
PREVENTION
DEVICES
LASER
MARKERS
PLC
HUMAN
MACHINE
INTERFACES
ENERGY
CONSUMPTION
VISUALIZATION
COMPONENTS
FA
COMPONENTS
MACHINE
VISION
SYSTEMS
UV
CURING
SYSTEMS
FIBER OPTIONS Refer to p. 69~ for details of lens dimensions.
Others Protective tube
Universal sensor mounting stand
Using the arm which enables adjustment in
the horizontal direction, sensing can also be
done from above an assembly line.
Fiber bender
• FB-1
• MS-AJ1-F
• MS-AJ2-F
360° rotation
360°
rotation
Angle adjustment: ±20°
20°
20°
Height
adjustment:
150 mm 5.906 in
approx.
Mounting hole
for M6 screw
Forward / back
adjustment:
130 mm
5.118 in approx.
360° rotation
360°
rotation
Angle adjustment: ±20°
20°
20° Mounting hole
for M6 screw
Forward / back
adjustment:
130 mm
5.118 in approx.
Height
adjustment:
150 mm 5.906 in
approx.
FTP-□
FDP-□
Designation Model No. Description
Protective tube
for thru-beam
type ber
FTP-500 (0.5 m 1.640 ft)
For M4
thread
Applicable bers
FT-42
FT-42S
FT-42W
FT-43
FT-H13-FM2
The protective
tube, made of non-
corrosive stainless
steel, protects the
inner ber cable from
any external forces.
FTP-1000 (1 m 3.281 ft)
FTP-1500 (1.5 m 4.921 ft)
FTP-N500 (0.5 m 1.640 ft)
For M3
thread
FT-31
FT-31S
FT-31W
FD-31
FD-31W
FTP-N1000 (1 m 3.281 ft)
FTP-N1500 (1.5 m 4.921 ft)
Protective tube
for reective
type ber
FDP-500 (0.5 m 1.640 ft)
For M6
thread
FD-61
FD-61G
FD-61S
FD-61W
FD-62
FD-H13-FM2
FDP-1000 (1 m 3.281 ft)
FDP-1500 (1.5 m 4.921 ft)
FDP-N500 (0.5 m 1.640 ft)
For M4
thread
FD-41
FD-41W
FD-41S
FD-41SW
FDP-N1000 (1 m 3.281 ft)
FDP-N1500 (1.5 m 4.921 ft)
Fiber bender FB-1 The ber bender bends the sleeve part of the ber head at the proper
radius. (Note 1)
Universal sensor
mounting stand
(Note 2)
MS-AJ1-F Horizontal mounting type Mounting stand assembly for ber
(For M3,
M4 or M6 threaded head ber)
MS-AJ2-F Vertical mounting type
Liquid inow
prevention
joint
(Note 2)
MS-FX-01Y
Applicable bers
FD-HF40Y
FD-F41Y
This joint suppresses false operations
due to liquid slip-in from the top of the
protective tube.
Protective tube
extension joint
(Note 2)
MS-FX-02Y
The protective tube can be extended.
Fiber
mounting joint
(Note 2)
MS-FX-03Y The joint is used for mounting bers on a
tank.
Single core
holder FX-AT15A
The incident light intensity may vary when using a multi-core ber or a
thin type sharp bending ber. This holder suppresses the variation in
the incident light intensity. (Brown)
Reector
RF-210 Used with FR-Z50HW.
Refer to p.30 or p.41 for the sensing range of FR-Z50HW to be used
in combination.
RF-220
RF-230
Notes: 1) Do not bend the sleeve part of any side-view type ber or ultra-small diameter head type ber.
2)
The joint internal ferrule (MS-FX-YF) is available as a spare part. A distorted ferrule may result in leakage.
Single core holder
• FX-AT15A
Liquid inow prevention joint
• MS-FX-01Y
MS-FX-03Y
MS-FX-02YMS-FX-01Y
Union nut Union nut
Union nut
Union nut
Body
Body
Body
Ferrule (MS-FX-YF)Ferrule (MS-FX-YF)
Ferrule (MS-FX-YF)
Ferrule (MS-FX-YF)
Protective tube extension joint
• MS-FX-02Y
MS-FX-03Y
MS-FX-02YMS-FX-01Y
Union nut
Union nut
Union nut
Union nut
Body
Body
Body
Ferrule (MS-FX-YF)
Ferrule (MS-FX-YF)
Ferrule (MS-FX-YF)
Ferrule (MS-FX-YF)
Fiber mounting joint
• MS-FX-03Y
MS-FX-03Y
MS-FX-02YMS-FX-01Y
Union nut
Union nut
Union nut
Union nut
Body
Body
Body
Ferrule (MS-FX-YF)
Ferrule (MS-FX-YF)
Ferrule (MS-FX-YF)
Ferrule (MS-FX-YF)
Reector
RF-210
1.311 in
33.3 mm 0.433 in
11 mm
12.8mm
0.504 in
•RF-220
1.390 in
35.3 mm
8.3 mm
42.3 mm
1.665 in
0.327 in
1.980 in
50.3 mm
0.327 in
8.3 mm
59.3 mm
2.335 in
•RF-230
157
Digital Fiber Sensor FX-300 SERIES
Selection
Guide
Fibers
Fiber
Ampliers
FX-500
FX-100
FX-300
FX-410
FX-311
FX-301-F7/
FX-301-F
FIBER
SENSORS
LASER
SENSORS
PHOTO-
ELECTRIC
SENSORS
MICRO
PHOTO-
ELECTRIC
SENSORS
AREA
SENSORS
LIGHT
CURTAINS /
SAFETY
COMPONENTS
PRESSURE /
FLOW
SENSORS
INDUCTIVE
PROXIMITY
SENSORS
PARTICULAR
USE
SENSORS
SENSOR
OPTIONS
SIMPLE
WIRE-SAVING
UNITS
WIRE-SAVING
SYSTEMS
MEASURE-
MENT
SENSORS
STATIC
ELECTRICITY
PREVENTION
DEVICES
LASER
MARKERS
PLC
HUMAN
MACHINE
INTERFACES
ENERGY
CONSUMPTION
VISUALIZATION
COMPONENTS
FA
COMPONENTS
MACHINE
VISION
SYSTEMS
UV
CURING
SYSTEMS
SPECIFICATIONS
Notes: 1) Where measurement conditions have not been specied precisely, the conditions used were an ambient temperature of +23 °C +73.4 °F.
2) 50 mA per output. 25 mA if ve, or more, ampliers are connected in cascade.
3) The light emitting amount can be zero (emission halt) in all modes.
4) When the power supply is switched on, the light emission timing is automatically set for interference prevention.
5) When the interference prevention function “ ” is set, the number of mountable ber heads becomes double.
Furthermore, take care that the response time also becomes double.
6) The voltage withstandability and the insulation resistance values given in the above table are for the amplier only.
7)
The cable for amplier connection is not supplied as an accessory. Make sure to use the optional quick-connection cables given below.
Main cable (3-core) for FX-301(P)(-HS): CN-73-C1 (Cable length 1 m 3.281 ft), CN-73-C2 (Cable length 2 m 6.562 ft), CN-73-C5 (Cable length 5 m 16.404 ft)
Sub cable (1-core) for FX-301(P)(-HS): CN-71-C1 (Cable length 1 m 3.281 ft), CN-71-C2 (Cable length 2 m 6.562 ft), CN-71-C5 (Cable length 5 m 16.404 ft)
Main cable (4-core) for FX-305(P): CN-74-C1 (Cable length 1 m 3.281 ft), CN-74-C2 (Cable length 2 m 6.562 ft), CN-74-C5 (Cable length 5 m 16.404 ft)
Sub cable (2-core) for FX-305(P): CN-72-C1 (Cable length 1 m 3.281 ft), CN-72-C2 (Cable length 2 m 6.562 ft), CN-72-C5 (Cable length 5 m 16.404 ft)
Type Standard type High-speed
type High-function type
Red LED Blue LED Green LED
Infrared LED
Model No.
NPN output FX-301 FX-301B FX-301G FX-301H FX-301-HS FX-305
Item PNP output FX-301P FX-301BP FX-301GP FX-301HP
FX-301P-HS
FX-305P
Supply voltage 12 to 24 V DC ±10 % Ripple P-P 10 % or less
Power consumption
<Red LED / Infrared LED type>
Normal operation: 960 mW or less (Current consumption 40 mA or less at 24 V supply voltage)
ECO mode: 600 mW or less (Current consumption 25 mA or less at 24 V supply voltage)
<Blue LED / Green LED type>
Normal operation: 720 mW or less (Current consumption 30 mA or less at 24 V supply voltage)
ECO mode: 430 mW or less (Current consumption 18 mA or less at 24 V supply voltage)
Output
<NPN output type>
NPN open-collector transistor
Maximum sink current:100 mA (50 mA, if ve, or more, ampliers are connected in cascade.)
Applied voltage: 30 V DC or less (between output and 0 V)
Residual voltage: 1.5 V or less [at 100 mA (at 50 mA, if ve, or more, ampliers are connected in cascade) sink current.]
<NPN output type>
NPN open-collector transistor 2 outputs
Maximum sink current: 50 mA each (Note 2)
Applied voltage: 30 V DC or less (between output and 0 V)
Residual voltage: 1.5 V or less [at 50 mA (Note 2)]
<PNP output type>
PNP open-collector transistor
Maximum source current: 100 mA (50 mA, if ve, or more, ampliers are connected in cascade.)
Applied voltage: 30 V DC or less (between output and +V)
Residual voltage: 1.5 V or less [at 100 mA (at 50 mA, if ve, or more, ampliers are connected in cascade) source current.]
<PNP output type>
PNP open-collector transistor 2 outputs
Maximum source current: 50 mA each (Note 2)
Applied voltage: 30 V DC or less (between output and +V)
Residual voltage: 1.5 V or less [at 50 mA (Note 2)]
Output operation Selectable either Light-ON or Dark-ON, with jog switch
Short-circuit protection Incorporated
Response time
65 µs or less [H-SP (Red LED type only)], 150 µs or less (FAST),
250 µs or less [STD / S-D (Red LED type only)],
2 ms or less (LONG), selectable with jog switch
35 µs or less (H-SP),
150 µs or less (FAST),
250 µs or less (STD / S-D),
2 ms or less (LONG),
selectable with jog switch
65 µs or less (H-SP), 150 µs or less (FAST),
250 µs or less (STD), 700 µs or less (STDF),
2.5 ms or less (LONG), 4.5 ms or less (U-LG),
selectable with jog switch
Sensitivity setting 2-point teaching / Limit teaching / Manual adjustment /
Full-auto teaching / Max. sensitivity teaching
Normal mode: 2-point teaching / Limit teaching / Full-auto teaching /
Max. sensitivity teaching / Manual adjustment
Window comparator mode: Teaching (1-point / 2-point / 3-point) / Manual adjustment
Operation indicator Orange LED (lights up when the output is ON)
Stability indicator
Green LED (lights up under stable light received condition or stable dark condition)
MODE indicator RUN: Green LED, TEACH • ADJ • L/D ON • TIMER • PRO: Yellow LED
Digital display 4 digit red LED display
Fine sensitivity adjustment function
Incorporated
Timer function
Incorporated with variable ON-delay / OFF-delay / ONE SHOT timer,
switchable either effective or ineffective.
Timer period: Red LED type; 0.5 ms approx., 1 to 9,999 ms
(Blue LED, Green LED, Infrared LED type; approx. 0.5 to 500 ms)
Incorporated with variable ON-delay / OFF-delay /
ONE SHOT / ON-delay • OFF-delay / ON-delay • ONE SHOT
timer, switchable either effective or ineffective.
(Timer period: Output 1; 0.5 ms, 1 to 9,999 ms, Output 2; 0.5 ms, 1 to 500 ms)
Light emitting amount
selection function
Incorporated (Red LED type only) (Note 3)
FAST, STD, LONG: 4 level, H-SP: 3 level, S-D: 2 level
Incorporated (Note 3)
FAST, STD, LONG: 4 level
H-SP, S-D: 2 level
Incorporated (Note 3)
FAST, STD, STDF, LONG, U-LG: 4 level
H-SP: 3 level
Automatic interference
prevention function
Incorporated (Up to four sets of ber heads can be mounted
close together. However, 2 ber heads in H-SP mode.) (Note 4)
Incorporated [Up to four sets of ber heads can be
mounted close together. (However, 8 ber heads in
U-LG mode, 2 ber heads in H-SP mode.)] (Note 5)
Environmental resistance
Ambient temperature
–10 to +55 °C +14 to +131 °F (If 4 to 7 units are connected in cascade: –10 to +50 °C +14 to +122 °F, if 8 to 16 units are
connected in cascade: –10 to +45 °C +14 to +113 °F) (No dew condensation or icing allowed), Storage: –20 to +70 °C – 4 to +158 °F
Ambient humidity 35 to 85 % RH, Storage: 35 to 85 % RH
Ambient illuminance Incandescent light: 3,000 ℓx at the light-receiving face
Voltage withstandability 1,000 V AC for one min. between all supply terminals connected together and enclosure (Note 6)
Insulation resistance 20 MΩ, or more, with 250 V DC megger between all supply terminals connected together and enclosure (Note 6)
Vibration resistance 10 to 150 Hz frequency, 0.75 mm 0.030 in amplitude in X, Y and Z directions for two hours each
Shock resistance 98 m/s2 acceleration (10 G approx.) in X, Y and Z directions for ve times each
Emitting element (modulated) Red LED Blue LED Green LED Infrared LED Red LED Red LED
Peak emission wavelength
650 nm 0.026 mil 470 nm 0.019 mil 525 nm 0.021 mil 940 nm 0.037 mil 650 nm 0.026 mil
650 nm 0.026 mil
Material
Enclosure: Heat-resistant ABS, Case cover: Polycarbonate, MODE key: Acrylic, Jog switch: Heat-resistant ABS (FX-301B/G/H: Acrylic)
Connecting method Connector (Note 7)
Cable length
Total length up to 100 m 328.084 ft (50 m 164.042 ft for 5 to 8 units, 20 m 65.617 ft for 9 to 16 units) is possible with 0.3 mm2, or more, cable.
Weight Net weight: 20 g approx., Gross weight: 25 g approx.
Accessory
FX-MB1 (amplier
protection seal): 1 set
FX-MB1 (amplier protection seal): 1 set
Digital Fiber Sensor FX-300 SERIES
158
Selection
Guide
Fibers
Fiber
Ampliers
FX-500
FX-100
FX-300
FX-410
FX-311
FX-301-F7/
FX-301-F
FIBER
SENSORS
LASER
SENSORS
PHOTO-
ELECTRIC
SENSORS
MICRO
PHOTO-
ELECTRIC
SENSORS
AREA
SENSORS
LIGHT
CURTAINS /
SAFETY
COMPONENTS
PRESSURE /
FLOW
SENSORS
INDUCTIVE
PROXIMITY
SENSORS
PARTICULAR
USE
SENSORS
SENSOR
OPTIONS
SIMPLE
WIRE-SAVING
UNITS
WIRE-SAVING
SYSTEMS
MEASURE-
MENT
SENSORS
STATIC
ELECTRICITY
PREVENTION
DEVICES
LASER
MARKERS
PLC
HUMAN
MACHINE
INTERFACES
ENERGY
CONSUMPTION
VISUALIZATION
COMPONENTS
FA
COMPONENTS
MACHINE
VISION
SYSTEMS
UV
CURING
SYSTEMS
(Black) Output 1
(White) Output 2
(Blue) 0 V (Note 1)
Users’ circuit Internal circuit
(Brown) +V (Note 1)
D
50 mA max. (Note 2)
50 mA max. (Note 2)
ZD1
Tr1
Tr2
ZD2
Load
Load
12 to 24 V DC
±10 %
Color code of quick-connection cable
Sensor circuit
+
1
3
4
2
Terminal No.
I/O CIRCUIT AND WIRING DIAGRAMS
FX-301(-HS)NPN output type
+
100 mA max. (Note 2)
(Blue) 0 V (Note 1)
12 to 24 V DC
±10 %
(Brown) +V (Note 1)
(Black) Output
Color code of quick-connection cable
Users’ circuit Internal circuit
T
erm
i
na
l
N
o.
Tr
D
ZD
Load
Sensor circuit
1
3
2
12 to 24 V DC
±10 %
Brown (Note)
Black
Blue (Note)
+
Color code of quick-connection cable
Load
Notes: 1) The quick-connection sub cable does not have +V (brown) and 0 V
(blue). The power is supplied from the connector of the main cable.
2) 50 mA max., if ve ampliers, or more, are connected together.
Note: The quick-connection sub cable does not have brown lead wire and
blue lead wire.
Terminal arrangement diagram
+V
Output
0 V
1
3
2
I/O circuit diagram Wiring diagram
Symbols … D : Reverse supply polarity protection diode
ZD: Surge absorption zener diode
Tr : NPN output transistor
FX-301P(-HS)PNP output type
100 mA max. (Note 2)
(Black) Output
(Blue) 0 V (Note 1)
12 to 24 V DC
±10 %
+
(Brown) +V (Note 1)
Color code of quick-connection cable
T
erm
i
na
l
N
o.
Users’ circuit Internal circuit
D
ZD
Tr
Load
Sensor circuit
3
2
1
Load
Brown (Note)
Black
Blue (Note)
Color code of quick-connection cable
12 to 24 V DC
±10 %
+
+V
Output
0 V
1
3
2
I/O circuit diagram Wiring diagram
Notes: 1) The quick-connection sub cable does not have +V (brown) and 0 V
(blue). The power is supplied from the connector of the main cable.
2) 50 mA max., if ve ampliers, or more, are connected together.
Symbols … D : Reverse supply polarity protection diode
ZD: Surge absorption zener diode
Tr : PNP output transistor
Note: The quick-connection sub cable does not have brown lead wire and
blue lead wire.
Terminal arrangement diagram
FX-305 NPN output type
50 mA max. (Note 2)
(White) Output 2
D
ZD1
Tr1
Tr2
50 mA max. (Note 2)
ZD2
Load
Load
Sensor circuit
Users’ circuit Internal circuit
(Blue) 0 V (Note 1)
Color code of quick-connection cable
T
erm
i
na
l
N
o.
(Brown) +V (Note 1)
(Black) Output + 12 to 24 V DC
±10 %
1
3
2
4
Brown (Note)
Black
Blue (Note)
White
Color code of quick-connection cable
Load Load
12 to 24 V DC
±10 %
+
+V
Output 1
0 V
1
3
Output 2
4
2
I/O circuit diagram Wiring diagram
Notes: 1) The quick-connection sub cable does not have +V (brown) and 0 V
(blue). The power is supplied from the connector of the main cable.
2) 25 mA max., if ve ampliers, or more, are connected together.
Symbols … D: Reverse supply polarity protection diode
ZD1, ZD2: Surge absorption zener diode
Tr1, Tr2 : NPN output transistor
Note: The quick-connection sub cable does not have brown lead wire and
blue lead wire.
Terminal arrangement diagram
FX-305P PNP output type
Brown (Note)
Black
Blue
(
Note
)
White
Color code of quick-connection cable
Load Load
12 to 24 V DC
±10 %
+
Output 1
0 V
1
3
Output 2
4
2
+V
I/O circuit diagram Wiring diagram
Notes: 1) The quick-connection sub cable does not have +V (brown) and 0 V
(blue). The power is supplied from the connector of the main cable.
2) 25 mA max., if ve ampliers, or more, are connected together.
Symbols … D: Reverse supply polarity protection diode
ZD1, ZD2: Surge absorption zener diode
Tr1, Tr2 : PNP output transistor
Note: The quick-connection sub cable does not have brown lead wire and
blue lead wire.
Terminal arrangement diagram
159
Digital Fiber Sensor FX-300 SERIES
Selection
Guide
Fibers
Fiber
Ampliers
FX-500
FX-100
FX-300
FX-410
FX-311
FX-301-F7/
FX-301-F
FIBER
SENSORS
LASER
SENSORS
PHOTO-
ELECTRIC
SENSORS
MICRO
PHOTO-
ELECTRIC
SENSORS
AREA
SENSORS
LIGHT
CURTAINS /
SAFETY
COMPONENTS
PRESSURE /
FLOW
SENSORS
INDUCTIVE
PROXIMITY
SENSORS
PARTICULAR
USE
SENSORS
SENSOR
OPTIONS
SIMPLE
WIRE-SAVING
UNITS
WIRE-SAVING
SYSTEMS
MEASURE-
MENT
SENSORS
STATIC
ELECTRICITY
PREVENTION
DEVICES
LASER
MARKERS
PLC
HUMAN
MACHINE
INTERFACES
ENERGY
CONSUMPTION
VISUALIZATION
COMPONENTS
FA
COMPONENTS
MACHINE
VISION
SYSTEMS
UV
CURING
SYSTEMS
Cascading
• Make sure that the power supply is off while adding or
removing the ampliers.
• Make sure to check the allowable ambient temperature,
as it depends on the number of ampliers connected in
cascade.
• In case two, or more, ampliers are connected in
cascade, make sure to mount them on a DIN rail.
• When the ampliers move on the DIN rail depending on
the attaching condition or the ampliers are mounted
close to each other in cascade, t them between the
optional end plates (MS-DIN-E) mounted at the two
ends.
• Up to maximum 15 ampliers can be added (total 16
ampliers connected in cascade.)
• When connecting more than two ampliers in cascade,
use the sub cable (CN-71-C□ / CN-72-C□) as the
quick-connection cable for the second amplier
onwards.
• When connecting ampliers not close to each other
in parallel, be sure to mount the optional end plate
(MS-DIN-E) at both sides of each amplier or afx the
communication window seal of the accessory amplier
protection seal (FX-MB1) to the communication
windows.
• The settings other than the interference prevention
function cannot be transmitted between FX-301(P)
FX-301B/G/H(P), FX-305(P). Therefore, in case both
models of ampliers are mounted in cascade, be sure
to mount identical models together. However, the
interference prevention function is not incorporated in
the FX-301(P)-HS. Take care when the sensors are
mounted in cascade.
If the FX-301(P) updated version unit or the FX-305(P)
is mounted with the FX-301(P) previous version unit or
the FX-301B/G/H(P) in cascade, place the FX-301(P)
updated version units and the FX-305(P) units to
the right side (seen from the connector side) of the
previous version units. For details, refer to “Cautions
on sensor connection in cascade”.
For a difference between the updated version unit
and the previous version unit, refer to “A difference
between the updated version unit and the previous
version unit”.
• The communication function of this product and that of
the FX-301(P)-F / F7 is different. If these models are
mounted in cascade, afx the accessory ber amplier
protection seal (FX-MB1) included in the FX-301(P)
and FX-305(P) to the communication windows of the
ampliers.
Mounting
Connection
PRECAUTIONS FOR PROPER USE Refer to p.1458~ for general precautions and to the “PRO mode operation guide”
on our website for details pertaining to operating instructions for the amplier.
• The digital ber sensor FX-301(P) has been modied
since its production in June 2004. The explanations
below are about the modied product.
• Never use this product as a sensing device
for personnel protection.
• In case of using sensing devices for
personnel protection, use products which
meet laws and standards, such as OSHA,
ANSI or IEC etc., for personnel protection
applicable in each region or country.
Disconnection method
Projection
How to mount the amplier
Fit the rear part of the mounting section of the
amplier on a 35 mm 1.378 in width DIN rail.
Press down the rear part of the mounting
section of the unit on the 35 mm 1.378 in width
DIN rail and t the front part of the mounting
section to the 35 mm 1.378 in width DIN rail.
How to remove the amplier
Push the amplier forward.
Lift up the front part of the amplier
to remove it.
Note: Take care that if the front part is lifted without pushing the
amplier forward, the hook on the rear portion of the mounting
section is likely to break.
Fiber installation
• Insert the ber into the amplier after attaching the
attachment. Refer to the "Instruction Manual" included
with the ber for details.
• Make sure that the power supply is off while connecting
or disconnecting the quick-connection cable.
35 mm 1.378 in width
DIN rail
Push the ber lock lever down.
Slowly insert the ber into the insertion
slot until it stops. (Note 1)
Push the ber lock lever back up until
it stops.
Holding the connector of the
quick-connection cable, align
its projection with the groove
at the top portion of the
amplier connector.
Insert the connector till a click
is felt.
Notes: 1)
Note that if the ber is not fully inserted, the sensing distance will
decrease. Also note that the exible ber may bend during insertion.
2)
In case of coaxial reective type bers (FD-G4, FD-FM2, etc.),
mount the central ber (single-core) to the emitter part and the
peripheral ber (multi-core) to the receiver. Note that sensing
precision will deteriorate when done in reverse.
Fiber
Fiber lock
lever
Connection method
Groove
Projection
Quick-connection cable
Pressing the projection at the
top of the quick-connection
cable, pull out the connector.
Note: Take care that if the connector
is pulled out without pressing the
projection, the projection may break.
Do not use a quick-connection cable
whose projection has broken.
Further, do not pull by holding the
cable, as this can cause a
cable-break.
Digital Fiber Sensor FX-300 SERIES
160
Selection
Guide
Fibers
Fiber
Ampliers
FX-500
FX-100
FX-300
FX-410
FX-311
FX-301-F7/
FX-301-F
FIBER
SENSORS
LASER
SENSORS
PHOTO-
ELECTRIC
SENSORS
MICRO
PHOTO-
ELECTRIC
SENSORS
AREA
SENSORS
LIGHT
CURTAINS /
SAFETY
COMPONENTS
PRESSURE /
FLOW
SENSORS
INDUCTIVE
PROXIMITY
SENSORS
PARTICULAR
USE
SENSORS
SENSOR
OPTIONS
SIMPLE
WIRE-SAVING
UNITS
WIRE-SAVING
SYSTEMS
MEASURE-
MENT
SENSORS
STATIC
ELECTRICITY
PREVENTION
DEVICES
LASER
MARKERS
PLC
HUMAN
MACHINE
INTERFACES
ENERGY
CONSUMPTION
VISUALIZATION
COMPONENTS
FA
COMPONENTS
MACHINE
VISION
SYSTEMS
UV
CURING
SYSTEMS
PRECAUTIONS FOR PROPER USE
Cautions on sensor connection in cascade
• When the units of the group A and the group B are
connected in cascade as <Figure B> shown above,
optical communications cannot be done. When the
optical communications function is used, connect them as
<Figure A> shown above. If the units cannot be placed
as <Figure A>, the following measure
1
or
2
should be
taken.
1
Afx the communication window seal of the accessory
ber amplier protection seal (FX-MB1) to the
communication window of the FX-301(P) updated
version unit or FX-305(P).
2
If the measure
1
described above cannot be taken,
change the optical communications spec. of the group B
units.
• When the units in the group A and the group B shown in
the table below are connected in cascade, connect them
in cascade as <Figure A> shown below.
Group B
Group A
<Figure A>
Group A
Group B
<Figure B>
Optical communications
are possible Optical communications
are impossible
Group A
FX-301(P): Previous version unit
(Note 1), FX-301G(P)/B(P)/H(P),
FX-41□(P), LS-401(P) (Note 2)
Group B
FX-301(P): Updated version
unit (Note 1), FX-305(P)
Notes: 1) For the difference between the updated
version unit and the previous version
unit, refer to “A difference between the
updated version unit and the previous
version unit”.
2)
When LS-401(P) is connected with the
digital ber amplier in cascade, be sure to
locate LS-401(P) at the left-most position
(when viewed from the connector side).
Notes: 1) FX-305(P); Output 1 operation indicator (Orange)
2) FX-305(P); Output 2 operation indicator (Orange)
MODE indicator / L/D ON (Yellow)
MODE indicator / TIMER (Yellow)
MODE key
Jog switch
MODE indicator /
PRO
(Yellow)
Digital display (Red)
MODE indicator / ADJ (Yellow)
MODE indicator / TEACH (Yellow)
MODE indicator / RUN (Green)
Operation indicator (Orange) (Note1)
Stability indicator
(Green)(Note2)
Mount the ampliers, one by
one, on the 35 mm 1.378 in
width DIN rail.
Slide the ampliers next to each
other, and connect the quick-
connection cables.
Mount the optional end plates
(MS-DIN-E) at both the ends to
hold the ampliers between
their at sides.
Tighten the screws to x the
end plates.
• Change the communication specication of Group B
according to the following procedures. Make sure to set the
communication specication to “ (Group A communication
specication)” or “ (Optical Communication Stop)”.
Dismantling
Cascading method
How to change the communication specication of Group B
Loosen the screws of the end
plates.
Remove the end plates.
Slide the ampliers and remove
them one by one.
35 mm 1.378 in
width DIN rail
Sub unit
Main unit
Slide
Sub cable
(CN-71/72-C□)
(Optional)
Main cable
(CN-73/74-C□)
(Optional)
End plate
(MS-DIN-E)
(Optional)
Slide
Notes: 4) When the communication specication is set to “ (Group A
communication specication)”, make sure to tightly attach the
products. Also make sure to take note of the following:
There are instances when the optical communication function
cannot be used due to the usage environment, etc.
Do not perform batch channel loading or saving.
Group B's Communication
Specification
Group A's Communication
Specification
Optical Communication Stop
<Changing Procedure>
Display [PRO4].
Long press the [Jog Switch] and
[MODE key] at the same time.
(Note 3)
When you release the [Jog Switch] and
[MODE key], the communication specication
will be set and “PRO4” will be displayed.
Notes: 3) Every time the [Jog Switch] and the [MODE key] is
simultaneously long pressed, the display changes in
this sequence: “ ”→“ ”→“ ”→“ ”→“ ”.
Part description
Operation procedure
Power ON
Communication self-check
RUN
TEACH
ADJ L/D
TIMER
PRO
Press
MODE key
Press
MODE key
Press
MODE key
Press
MODE key
Press
MODE key
Press
MODE key
[Teaching]
(P.161)
[Threshold
value ne
adjust] (P.162)
[PRO mode]
[Timer operation
setting]
(P.162)
[Output operation
setting]
(P.162)
• When the power supply is switched on, communication
self-check is carried out and normal condition is
displayed [MODE indicator / RUN (green)] lights up and
the digital display shows the incident light intensity.
• When the MODE key is pressed, the mode will change as
shown in the following diagram.
When Jog switch is pressed, the setting is conrmed.
When MODE key is pressed for 2 sec., or more, the sensor returns to the ‘RUN’ mode.
Cancellation is possible by pressing MODE key during setting.
Refer to p.1458~ for general precautions and to the “PRO mode operation guide”
on our website for details pertaining to operating instructions for the amplier.
161
Digital Fiber Sensor FX-300 SERIES
Selection
Guide
Fibers
Fiber
Ampliers
FX-500
FX-100
FX-300
FX-410
FX-311
FX-301-F7/
FX-301-F
FIBER
SENSORS
LASER
SENSORS
PHOTO-
ELECTRIC
SENSORS
MICRO
PHOTO-
ELECTRIC
SENSORS
AREA
SENSORS
LIGHT
CURTAINS /
SAFETY
COMPONENTS
PRESSURE /
FLOW
SENSORS
INDUCTIVE
PROXIMITY
SENSORS
PARTICULAR
USE
SENSORS
SENSOR
OPTIONS
SIMPLE
WIRE-SAVING
UNITS
WIRE-SAVING
SYSTEMS
MEASURE-
MENT
SENSORS
STATIC
ELECTRICITY
PREVENTION
DEVICES
LASER
MARKERS
PLC
HUMAN
MACHINE
INTERFACES
ENERGY
CONSUMPTION
VISUALIZATION
COMPONENTS
FA
COMPONENTS
MACHINE
VISION
SYSTEMS
UV
CURING
SYSTEMS
For FX-305(P)
The FX-305(P) is equipped with two independent outputs, but
the items that can be set in output 1 and output 2 respectively
are only the following.
The items other than those are common.
1
Threshold value
2
Output operation
3
Timer operation and Timer period
4
Sensing mode
Teaching
The threshold values can be set by 2-point teaching, limit
teaching, full-auto teaching or window comparator mode
(1-point, 2-point, 3-point teaching) [only for FX-305(P)],
when the MODE indicator / TEACH (yellow) lights up.
This is the method of setting the threshold value by teaching
two levels, corresponding to the object present and object
absent conditions. Normally, setting is done by this method.
Step
Description Display
Set the ber within the
sensing range.
Press MODE key to light
up MODE indicator /
TEACH (yellow).
For FX-305(P), select either Output 1 “ ” or
Output 2 “ ” beforehand, press jog switch
in the object present condition.
If the teaching is accepted, the read incident
light intensity blinks in the digital display.
Beam
blocked condition
Thru-beam type
Reflective type
Mark
Background
MODE indicator / TEACH (yellow) blinks.
Press jog switch in the object absent condition.
Beam
incident condition
Mark
Background
Thru-beam type
Reflective type
If the teaching is accepted, the read incident
light intensity blinks in the digital display
and the threshold value is set at the mid-
value between the incident light intensities
in the object present and the object absent
conditions. After this, the judgment on the
stability of sensing is displayed.
In case stable sensing is possible: “ ” is displayed.
In case stable sensing is not possible: “ ” blinks.
The threshold value is displayed.
” blinks in the digital display.
(only FX-301B/G/H)
The incident light intensity appears in the
digital display and the setting is complete.
Notes: 1) Do not move or bend the ber cable after the sensitivity setting.
Detection may become unstable.
2) In case a reective-type ber is used, maximum sensitivity will be
set if the jog switch is pushed while in no work status in procedure
and .
Step
Description Display
Set the ber within the
sensing range.
Press MODE key to light
up MODE indicator /
TEACH (yellow).
For FX-305(P), select either Output 1 “ ” or
Output 2 “ ” beforehand, press the jog switch
continuously for 0.5 sec. or more with the object
moving on the assembly line. (The incident light
intensity is displayed during sampling.)
” is displayed on the digital display. Release
the jog switch when the object has passed.
If the teaching is accepted, the read incident
light intensity blinks in the digital display
and the threshold value is set at the mid-
value between the incident light intensities
in the object present and the object absent
conditions. After this, the judgment on the
stability of sensing is displayed.
In case stable sensing is possible: “ ” is displayed.
In case stable sensing is not possible: “ ” blinks.
The threshold value is displayed.
” blinks in the digital display.
(only FX-301B/G/H)
The incident light intensity appears in the
digital display and the setting is complete.
Notes: 1) The threshold value’s shift amount can be selected in PRO mode.
Refer to the “PRO Mode Operation Guide” for more details
pertaining to setting instructions. (Increments of 5 % between –45
and 45 % for setting possible. 0 % default.)
2) Do not move or bend the ber cable after the sensitivity setting.
Detection may become unstable.
In case of 2-point teaching
Full auto-teaching is used when it is desired to set the
threshold value without stopping the assembly line, with
the object in the moving condition.
In case of full auto-teaching
Refer to p.1458~ for general precautions and to the “PRO mode operation guide”
on our website for details pertaining to operating instructions for the amplier.
PRECAUTIONS FOR PROPER USE
Digital Fiber Sensor FX-300 SERIES
162
Selection
Guide
Fibers
Fiber
Ampliers
FX-500
FX-100
FX-300
FX-410
FX-311
FX-301-F7/
FX-301-F
FIBER
SENSORS
LASER
SENSORS
PHOTO-
ELECTRIC
SENSORS
MICRO
PHOTO-
ELECTRIC
SENSORS
AREA
SENSORS
LIGHT
CURTAINS /
SAFETY
COMPONENTS
PRESSURE /
FLOW
SENSORS
INDUCTIVE
PROXIMITY
SENSORS
PARTICULAR
USE
SENSORS
SENSOR
OPTIONS
SIMPLE
WIRE-SAVING
UNITS
WIRE-SAVING
SYSTEMS
MEASURE-
MENT
SENSORS
STATIC
ELECTRICITY
PREVENTION
DEVICES
LASER
MARKERS
PLC
HUMAN
MACHINE
INTERFACES
ENERGY
CONSUMPTION
VISUALIZATION
COMPONENTS
FA
COMPONENTS
MACHINE
VISION
SYSTEMS
UV
CURING
SYSTEMS
PRECAUTIONS FOR PROPER USE
This is the method of setting the threshold value by
teaching only the object absent condition (stable incident
light condition). This is used for detection in the presence
of a background body or for detection of small objects.
Step
Description Display
Set the ber within the
sensing range.
Press MODE key to light
up MODE indicator /
TEACH (yellow).
For FX-305(P), select either Output 1 “ ” or
Output 2 “ ” beforehand, press jog switch
in the object absent condition. If the teaching
is accepted, the read incident light intensity
blinks in the display.
Thru-beam type Reflective type
Beam
incident condition
Background
body
MODE indicator / TEACH (yellow) blinks.
Turn jog switch to the “+” side or “–” side.
If jog switch is turned to the “+” side, “ ” scrolls
(twice) the display from right to left (Note 1), and the
threshold level is shifted to a value
approx. 15 % higher (lower sensitivity)
than that set at . (Note 2)
This is used in case of reective type bers.
If jog switch is turned to the “–” side, “ ” scrolls
(twice) the display from left to right, and the threshold
level is shifted to a value approx.
15 % lower (higher sensitivity)
than that set at . (Note 2)
This is used in case of thru-beam type bers.
After this, the judgment on whether the setting
shift amount can be shifted or not is displayed.
In case shifting is possible: ” blinks.
In case shifting is not possible: ” blinks.
The threshold value is displayed.
” blinks in the digital display.
(only FX-301B/G/H)
The incident light intensity appears in the
digital display and the setting is complete.
Notes: 1) Scrolling display is not available in FX-301B/G/H.
2) The approx. 15 % amount of shift is the initial value. The amount of
shift can be changed in the PRO mode from approx. 5 to 80 %
(5 % step). Refer to the “PRO Mode Operation Guide” for more
details pertaining to setting instructions.
3) Do not move or bend the ber cable after the sensitivity setting.
Detection may become unstable.
Step
Description Display
Press MODE key to light
up MODE indicator / ADJ
(yellow).
For FX-305(P), select either Output 1 “
or Output 2 “ ” beforehand, in case the
threshold value is to be increased (sensitivity
to be reduced), turn the jog switch
to the “+” side to increase the
threshold value slowly. If the
jog switch is turned continuously to the “+”
side, the threshold value increases rapidly.
In case the threshold value is to be decreased
(sensitivity to be increased), turn the jog
switch to the “–” side to decrease the
threshold value slowly. If the jog
switch is turned continuously to
the “–” side, the threshold value
decreases rapidly.
or
When jog switch is pressed,
the threshold value is
conrmed.
Output operation setting
Threshold value ne adjustment
Step
Description Display
Press MODE key to light
up MODE indicator / L/D
ON (yellow). Displays
present setting
For FX-305(P), select either Output 1 “
or Output 2 “ ” beforehand,
if the jog switch is turn to
the “+” or “–” direction,
the output operation setting
will change.
Light state
Dark state
When jog switch is pressed,
the threshold value is
conrmed. Displays
selected setting
Timer operation setting
The setting for whether the timer is used or not can be
done when MODE indicator / TIMER (yellow) lights up.
For FX-301B/G/H, the timer type can be set in PRO
mode.
Further, an OFF-delay (initial value) which is useful when
the response of the connected device is slow, etc., an
ON-delay which is useful to detect only objects taking a
long time to travel, and ONE SHOT, which is useful when
the input specications of the connected device require a
signal of a xed width, are possible with the FX-301□(-HS).
FX-305(P) is also equipped with ON-delay • OFF-delay and
ON-delay • ONE SHOT timers. Refer to the “PRO Mode
Operation Guide” for the setting method of the OFF-delay,
ON-delay and ONE SHOT timer intervals.
Incident light intensity
with object absent
Threshold value
Threshold value
15 %
15 %
ON
OFF
High
Low
100 %
Turn to “+” side
Turn to “–” side
OFF
ON
0
Threshold
value
In case of limit teaching
For the wind comparator mode teaching in FX-305(P), refer to
the separately prepared “PRO Mode Operation Guide”.
Please download the instruction manual from our website for
setting of threshold value when used in combination with liquid
level sensing ber FD-F8Y and with pipe-mountable liquid level
sensing ber FD-F4□.
Refer to p.1458~ for general precautions and to the “PRO mode operation guide”
on our website for details pertaining to operating instructions for the amplier.
163
Digital Fiber Sensor FX-300 SERIES
Selection
Guide
Fibers
Fiber
Ampliers
FX-500
FX-100
FX-300
FX-410
FX-311
FX-301-F7/
FX-301-F
FIBER
SENSORS
LASER
SENSORS
PHOTO-
ELECTRIC
SENSORS
MICRO
PHOTO-
ELECTRIC
SENSORS
AREA
SENSORS
LIGHT
CURTAINS /
SAFETY
COMPONENTS
PRESSURE /
FLOW
SENSORS
INDUCTIVE
PROXIMITY
SENSORS
PARTICULAR
USE
SENSORS
SENSOR
OPTIONS
SIMPLE
WIRE-SAVING
UNITS
WIRE-SAVING
SYSTEMS
MEASURE-
MENT
SENSORS
STATIC
ELECTRICITY
PREVENTION
DEVICES
LASER
MARKERS
PLC
HUMAN
MACHINE
INTERFACES
ENERGY
CONSUMPTION
VISUALIZATION
COMPONENTS
FA
COMPONENTS
MACHINE
VISION
SYSTEMS
UV
CURING
SYSTEMS
PRECAUTIONS FOR PROPER USE
Peripheral units that can be combined
Function table for FX-300 series
Previous models New models
Standard type
High-function type
High-speed type Standard type High-speed type
High-function type
FX-301(P)
(Previous version unit)
FX-302(P)FX-303(P)FX-301(P)
(Updated version unit)
FX-301
(P)
-HS
FX-305(P)
Four-chemical emitting element + APC circuit
No No No Yes Yes Yes
Four-chemical emitting element only
Yes (Note) Yes Yes
Light emitting amount selection function
No No No Yes Yes Yes
Reduced intensity mode (S-D)
Yes (Note) Yes No Yes Yes
9,999 digit display No No No No No Yes
Response time (Max. speed) 150 μs 300 μs 90 μs 65 μs 35 μs 65 μs
Interference prevention function (Effective no. of units)
Incorporated (4) Incorporated (8)
Not incorporated (0)
Incorporated (4)
Not incorporated (0)
Incorporated (16)
Independent 2 outputs No No No No No Yes
Alarm output function No No No No No Yes
Error output function No No No No No Yes
Differential sensing No No No No No Yes
Window comparator mode No Yes No No No Yes
Bank selection unit
FX-CH(-P)Yes Yes No No No No
External input unit
FX-CH2(-P)No No No Yes No Yes
Upper communication unit
SC-GU1-485 No No No Yes No Yes
Note: Except FX-301B/G/H.
Wiring Key-lock function
• Make sure that the power supply is off while wiring.
• Verify that the supply voltage variation is within the rating.
• Take care that if a voltage exceeding the rated range is
applied, or if an AC power supply is directly connected,
the product may get burnt or damaged.
• If power is supplied from a commercial switching
regulator, ensure that the frame ground (F.G.) terminal of
the power supply is connected to an actual ground.
• In case noise generating equipment (switching regulator,
inverter motor, etc.) is used in the vicinity of this
product, connect the frame ground (F.G.) terminal of the
equipment to an actual ground.
• Take care that short circuit of the load wrong wiring may
burn or damage the product.
• Do not run the wires together with high-voltage lines or
power lines or put them in the same raceway. This can
cause malfunction due to induction.
• Make sure to use an isolation transformer for the DC
power supply. If an autotransformer (single winding
transformer) is used, this product or the power supply
may get damaged.
• Make sure to use the optional quick-connection cable for
the connection of the amplier. Extension up to total 100
m 328.084 ft is possible with 0.3 mm2, or more, cable.
(5-8 unit expansion: 50 m 164.042 ft, 9-16 unit
expansion: 20 m 65.617 ft) However, in order to reduce
noise, make the wiring as short as possible.
• Note that the residual voltage will increase when the
cable is extended.
• If jog switch and MODE key are pressed for more than
2 sec. at the same time in ‘RUN’ mode condition, the
key operations are locked, and only the threshold value
conrmation function or the adjust function (valid only
when the adjust lock function is canceled) is valid.
To cancel the lock function, press both the keys for more
than 2 sec. once again.
Others
• When the emission halt of the light emitting amount
selection function is set from “OFF” to “ON”, the output
may be unstable. Do not use the output control for 0.5
sec. after starting emission.
• Do not use during the initial transient time (0.5 sec.) after
the power supply is switched on.
• Take care that the sensor is not directly exposed to
uorescent lamp from a rapid-starter lamp, a high
frequency lighting device or sunlight etc. , as it may affect
the sensing performance.
• Do not use this sensor in places having excessive vapor,
dust, etc., or where it may come in contact with corrosive
gas.
• Take care that the product does not come in direct
contact with water, oil, grease, or organic solvents, such
as, thinner, etc.
• This sensor cannot be used in an environment containing
inammable or explosive gases.
• Never disassemble or modify the sensor.
Note: 3 seconds or more for FX-301B/G/H(P).
Refer to p.1458~ for general precautions and to the “PRO mode operation guide”
on our website for details pertaining to operating instructions for the amplier.
Digital Fiber Sensor FX-300 SERIES
164
Selection
Guide
Fibers
Fiber
Ampliers
FX-500
FX-100
FX-300
FX-410
FX-311
FX-301-F7/
FX-301-F
FIBER
SENSORS
LASER
SENSORS
PHOTO-
ELECTRIC
SENSORS
MICRO
PHOTO-
ELECTRIC
SENSORS
AREA
SENSORS
LIGHT
CURTAINS /
SAFETY
COMPONENTS
PRESSURE /
FLOW
SENSORS
INDUCTIVE
PROXIMITY
SENSORS
PARTICULAR
USE
SENSORS
SENSOR
OPTIONS
SIMPLE
WIRE-SAVING
UNITS
WIRE-SAVING
SYSTEMS
MEASURE-
MENT
SENSORS
STATIC
ELECTRICITY
PREVENTION
DEVICES
LASER
MARKERS
PLC
HUMAN
MACHINE
INTERFACES
ENERGY
CONSUMPTION
VISUALIZATION
COMPONENTS
FA
COMPONENTS
MACHINE
VISION
SYSTEMS
UV
CURING
SYSTEMS
A difference between the updated version unit and
the previous version unit for FX-301(P) (Red LED type)
• The product has been modied as shown below since its
production in June 2004.
Changes in appearance
Before change After change
Top view Top view
Side view Side view
Name
plate
Display
Uses special parts
* “NAVI” is printed on the both sides
Added to
name plate
Change in shape
of jog switch
*
NAVI
is printed only on a side
• Checking minor changes between previous and
updated models can be done by checking whether the
printing is on both sides or only one side.
Upgraded functions
1. Response times added
An ultra high-speed mode (H-SP) has been added to
the existing 4 response time modes [high-speed (FAST),
reduced intensity (S-D), standard (STD) and long range
(LONG)].
This is changed using “ ” in “
2. Extension of timer period
The setting range for the timer period was previously
500 ms, but this has been extended to a new range of
9,999 ms.
Changes in operation
1. Timer selection method
Previous version unit: Timer type was changed using PRO1 mode.
The “TIMER” setting in NAVI mode could
only be turned on or off.
After change: The type of timer can be changed using the “TIMER”
function in NAVI mode.
2. Checking threshold value in RUN mode
The threshold values can be checked by turning the jog switch.
Display changes
1. Checking blinking of sensitivity surplus
The stable surplus display method after teaching has been changed.
Previous version unit: Sensitivity surplus is indicated by the number
of blinks of the stability indicator
.
Digital display only
After change
2. Initial direct code value changed
The factory default settings for the direct codes have been changed.
* The default setting for the timer period is 10 ms, and the direct code for
10 ms is “4”, so this has been changed.
Internal circuit changes
1. Addition of an APC circuit
A four-chemical emitting element which provides stable
sensing over long periods has been added, as well
as an APC (Auto Power Control) circuit that improves
stability during short periods.
Cautions on sensor connection in cascade
When connecting the previous version unit (including
FX-301B/G/H) and updated version unit to be used in a
cascade, refer to “Cautions on sensor connection in
cascade”.
4. Backup, copy lock and key lock functions added
Backup: This selects whether or not threshold values
set by teaching are written to (stored in) an
EEPROM.
Copy lock: This selects whether copy function and data
bank function communication are possible or
not.
Key lock: This disables input using switches to prevent
accidental changing of settings.
3. Light emitting amount selection function
The light emitting amount can be changed to one of
4 levels (5 levels when emission halt is included).
Previous version unit 0000 After change 0004
PRECAUTIONS FOR PROPER USE
Before change After change
4 steps
150 μs (FAST)
250 μs (S-D)
250 μs
(
STD
)
2 ms (LONG)
5 steps
150 μs (FAST)
65 μs (added) (H-SP)
250 μs (S-D)
250 μs (STD)
2 ms (LONG)
Refer to p.1458~ for general precautions and to the “PRO mode operation guide”
on our website for details pertaining to operating instructions for the amplier.
165
Digital Fiber Sensor FX-300 SERIES
Selection
Guide
Fibers
Fiber
Ampliers
FX-500
FX-100
FX-300
FX-410
FX-311
FX-301-F7/
FX-301-F
FIBER
SENSORS
LASER
SENSORS
PHOTO-
ELECTRIC
SENSORS
MICRO
PHOTO-
ELECTRIC
SENSORS
AREA
SENSORS
LIGHT
CURTAINS /
SAFETY
COMPONENTS
PRESSURE /
FLOW
SENSORS
INDUCTIVE
PROXIMITY
SENSORS
PARTICULAR
USE
SENSORS
SENSOR
OPTIONS
SIMPLE
WIRE-SAVING
UNITS
WIRE-SAVING
SYSTEMS
MEASURE-
MENT
SENSORS
STATIC
ELECTRICITY
PREVENTION
DEVICES
LASER
MARKERS
PLC
HUMAN
MACHINE
INTERFACES
ENERGY
CONSUMPTION
VISUALIZATION
COMPONENTS
FA
COMPONENTS
MACHINE
VISION
SYSTEMS
UV
CURING
SYSTEMS
PRECAUTIONS FOR PROPER USE
Diagram of functions and settings
The amplier features and settings are generally classied into two main modes; the “NAVI mode” for items and settings that
are frequently recongured, and the “PRO mode” that contains more detailed settings.
NAVI
mode
PRO
mode
Sets output operation either Light-ON,
or Dark-ON.
L-ON / D-ON
L/D
Configures operation of the timer.
Timer
TIMER
Allows various detailed settings to be
configured, such as optical communications,
save / load and other settings.
Pro
PRO
Switches among response times.
Response Time Change
Configures timer operation.
Timer Setting
Sets hysteresis level.
Hysteresis
The “threshold value” can be set by
utilizing either “2-point teaching”, “limit
teaching”, or “full-auto teaching”.
Teaching
TEACH
Allows fine adjustment of the
“threshold value”.
Adjust
ADJ
This indicates normal sensing operation.
Run
RUN
PRO1
PRO2
PRO3
PRO4
PRO5
Shifts the “threshold value” by a
certain percentage increment in
“limit teaching”.
Shift
Permits selection of stability indicator response
levels for changes in the range for lighting up.
[excluding the FX-305(P)]
Stability
Allows selection of different content
to be indicated in the digital display.
Digital Display Setting
Sets the viewing orientation of the
digital display.
Digital Display Inversion
Sets the digital display to turn
ON / OFF.
ECO Mode
Loads configuration setting from the
data bank.
Data Bank Load
Saves configuration setting into the
data bank.
Data Bank Save
Using optical communications, configuration
settings from the main unit are copied to
connected sub units all at once.
Copy
Using optical communication, configuration
settings can be loaded from respective data
banks all at once.
Using optical communication, current
configuration settings can be saved into
respective data banks all at once.
Remote Data Bank Load Remote Data Bank Save
When using optical communication for carrying out
copy / load / save operations all at once, this function
allows optical communication to pass through the unit.
Communication Change
To Permit / Not to Permit
Allows basic configuration information
to be set in a single step, by inputting
a 4-digit code.
Code
Allows fine adjustment of the “threshold
value” to be directly performed during
RUN mode.
Adjust Lock
All settings, except for data bank
information, revert to factory settings.
Reset
The items that can be set are different for output 1 and output 2.
Output 1
Output 2
Changes the light emitting amount
selection setting.
[FX-301(P)(-HS), FX-305(P) only]
Light Emitting Amount Selection
Allows not to save the threshold value, by
teaching via external input in EEPROM.
[FX-301(P), FX-305(P) only]
Backup
Switches the number of units for which
interference prevention switching is enabled.
* FX-305(P) only.
Interference Prevention
Switching
Sets a threshold value for ON /
OFF operation.
Normal Mode
Judges if set two threshold values are within the
required range or not. This can be selected in
1-point / 2-point / 3-point teaching.
Window Comparator Mode
Sensing mode that cancels out slight changes in
light intensity so that only sudden increases in
incident light intensity are sensed.
Rising Differential Mode
PRO6
Trailing Differential Mode
Sensing mode that cancels out slight changes in
light intensity so that only sudden decreases in
incident light intensity are sensed.
Error Output
Output when overcurrent occurs or when
a communication error occurs from
connected incompletely.
Alarm Output
Be used as alarm output when the threshold
value for output 2 is linked to output 1 and
the light amount drops.
Verifies whether optical communications
have been properly established.
(FX-301B/G/H only)
Test
* When the FX-305(P) is in window comparator mode,
the “threshold value” can be set by either “1-point
teaching”, “2-point teaching” or “3-point teaching”.
Available only in FX-305(P)
* The FX-301(P)-HS is not
equipped with a PRO4
setting function.
The FX-301(P)-HS is not
equipped with a PRO4
setting function.
* The 0-ADJ setting function equipped on the FX-301□ and FX-305(P) has been deleted since the production in May 2005.
Refer to p.1458~ for general precautions and to the “PRO mode operation guide”
on our website for details pertaining to operating instructions for the amplier.
Digital Fiber Sensor FX-300 SERIES
166
Selection
Guide
Fibers
Fiber
Ampliers
FX-500
FX-100
FX-300
FX-410
FX-311
FX-301-F7/
FX-301-F
FIBER
SENSORS
LASER
SENSORS
PHOTO-
ELECTRIC
SENSORS
MICRO
PHOTO-
ELECTRIC
SENSORS
AREA
SENSORS
LIGHT
CURTAINS /
SAFETY
COMPONENTS
PRESSURE /
FLOW
SENSORS
INDUCTIVE
PROXIMITY
SENSORS
PARTICULAR
USE
SENSORS
SENSOR
OPTIONS
SIMPLE
WIRE-SAVING
UNITS
WIRE-SAVING
SYSTEMS
MEASURE-
MENT
SENSORS
STATIC
ELECTRICITY
PREVENTION
DEVICES
LASER
MARKERS
PLC
HUMAN
MACHINE
INTERFACES
ENERGY
CONSUMPTION
VISUALIZATION
COMPONENTS
FA
COMPONENTS
MACHINE
VISION
SYSTEMS
UV
CURING
SYSTEMS
DIMENSIONS (Unit: mm in)The CAD data in the dimensions can be downloaded from our website.
Amplier
FX-301□ FX-305(P)
0.7
0.028
48.2
1.898
12
0.472
26.3
1.0352.5
0.098
8.3
0.327
MODE key
Jog switch
Digital display (Red)
Stability indicator
(Green) (Note 2)
Operation indicator
(Orange) (Note 1)
27.8
1.094 7
0.276
10.5
0.413
3.95
0.156
36.5
1.437
13.5
0.531
64.5
2.539
3
0.118
30.5
1.201
3
0.118
Communication
window
Suitable for 35 mm
1.378 in width DIN rail
7 0.276
7 0.276
10
0.394
Beam-
emitting
part
Beam-
receiving
part
(Note 3)
3.3
0.130
Notes: 1) FX-305□; Output 1 operation indicator (Orange)
2) FX-305□; Output 2 operation indicator (Orange)
3) FX-301□; 3-pin, FX-305□; 4-pin
Main cable (Optional)
CN-73-C□ CN-74-C□ Sub cable (Optional)
CN-71-C□ CN-72-C□
L
ø3.3 ø0.130 cable
5
0
1.969
(Note 1)
2.65
0.104
2.54
0.100
2.54
0.100
10.5
0.413
0.2
0.008
13.6
0.535
10
0.394
14
0.551
7.2
0.283
3
0.118
2.9
0.114
6
0.236
10
0.394
7
0.276
12
0.472
( )
( )
( )
( )
(Note 2)
Length L
Model No. Length L
CN-73/74-C1 1,000 39.370
CN-73/74-C2 2,000 78.740
CN-73/74-C5 5,000 196.850
L
2.65
0.104
2.54
0.100
2.54
0.100
10.5
0.413
0.2
0.008
13.6
0.535
10
0.394
14
0.551
7.2
0.283
3
0.118
2.9
0.114
6
0.236
10
0.394
7
0.276
50
1.969
12
0.472
( )
( ) ( )
(Note 2)
(Note 1)
3
0.118
( )
ø3.3 ø0.130 cable
Model No. Length L
CN-71/72-C1 1,000 39.370
CN-71/72-C2 2,000 78.740
CN-71/72-C5 5,000 196.850
Length L
Notes: 1) CN-74-C□ only
2) CN-73-C□; 3-core
Amplier mounting bracket (Optional)
MS-DIN-2
2-
ø
3.2
ø
0.126 holes
2
0.079
t 1
t 0.039
0.4
0.016
7.5
0.295
4.2 0.165
2
0.079
ø
1.8
ø
0.071
35
1.378
27
1.063
3.2
0.126
5.2
0.205
8.5
0.335
5.2
0.205 3.2
0.126
5
0.197
21.6 0.850
16 0.630
10
0.394
Material: Cold rolled carbon steel (SPCC)
(Uni-chrome plated)
Notes: 1) CN-72-C□ only
2) CN-71-C□: 1-core
End plate (Optional)
MS-DIN-E
2.75
0.108
4
0.157
3
0.118
M3 (length 18 mm 0.709 in) pan head screws
M3 square nut
5.6
0.220
24.7
0.972
1.6
0.063
32
1.260
60
2.362
15
0.591
3
0.118
Suitable for 35 mm 1.378 in width DIN rail
Material: Polycarbonate