GENH Series Programmable DC Power Supplies 750W in a 1U half-rack size Built in RS-232 & RS-485 Interface Advanced Parallel Standard Optional Interfaces: IEEE488.2 SCPI (GPIB) Isolated Analog Programming Compliant LAN GenesysTM GENH750W-1U The GenesysTM family of programmable power supplies sets a new standard for flexible, reliable, AC/DC power systems in OEM, Industrial and Laboratory applications. Features include: * High Power Density available: 750W in 1U half-rack size. * Wide Range Input (85 - 265Vac Continuous) * Active Power Factor Correction (0.99 typical) * Output Voltage up to 600V, Current up to 100A * Built-in RS-232/RS-485 Interface * Front Panel Lockout * Last-Setting Memory * High Resolution 16 bit ADCs & DACs * Reliable Encoders for Voltage and Current Adjustment * Constant Voltage/Constant Current auto-crossover * Advanced Parallel reports total current up to four identical units * Global Commands for Serial RS-232/RS-485 Interface * Independent Remote ON/OFF and Remote Enable/Disable * External Analog Programming and Monitoring * Reliable Modular and SMT Design * 19" Rack Mounted ATE benchtop and OEM applications * Side-by-side mounting of two units in a 19" rack * Optional Interfaces Isolated Analog Programming and Monitoring Interface (0-5V/0-10V & 4-20mA) IEEE 488.2 SCPI (GPIB) Multi-Drop Compliant LAN * LabView(R) and LabWindows(R) drivers * Five Year Warranty Worldwide Safety Agency Approvals; CE Mark for LVD and EMC Regulation Front Panel Description 1. AC ON/OFF Switch 2. Air Intake allows zero stacking for maximum system flexibility and power density. 3. Reliable encoder controls Output Voltage and sets Address. 4. Volt Display shows Output Voltage and directly displays OVP, UVL and Address settings. 5. Reliable encoder controls Output Current, sets baudrate and Advanced Parallel mode. 6. Current Display shows Output Current and displays baudrate. 7. Function/Status LEDs: * Alarm * Fine Control * Preview Settings * Foldback Mode * Remote Mode * Output On 8. Pushbuttons allow flexible user configuration * Coarse and Fine adjustment of Output Voltage/Current and Advanced Parallel Master or Slave * Preview settings and set Voltage/Current with Output OFF, Front Panel Lockout * Set OVP and UVL Limits * Set Current Foldback * Local/Remote Mode and select Address and Baudrate * Output ON/OFF and Auto-Start/Safe-Start Mode 1 Applications GenesysTM power supplies have been designed to meet the demands of a wide variety of applications. Test and Measurement Laser Diode Last-Setting memory simplifies test design and requires no battery backup. Built-in RS-232/RS-485 gives maximum system flexibility along with 0-5V and 0-10V, selectable analog programming. Wide range of available inputs allows testing of many different devices. OVP is directly set on Voltage Display, assuring accurate protection settings. Current Limit Fold Back assures load is protected from current surges. Semiconductor Burn-in Safe-Start may be ENABLED to re-start at Output OFF to protect load. Wide range input (85-265Vac) with Active Power Factor correction rides through input transients easily. Component Test Heater Supplies Smooth, reliable encoders enhance front panel control. Remote analog programming is user selectable 0-5V or 0-10V. RF Amplifiers and Magnets Robust design assures stable operation under a wide variety of loads. High linearity in voltage and current mode. High power density, zero stacking and single wire parallel operation give maximum system flexibility. Rear Panel Description 1. 2. 3. 4. 5. 6. Remote/Local Output Voltage Sense Connections. DIP Switches select 0-5V or 0-10V Programming and other functions. DB25 (Female) connector allows (Non-isolated) Analog Program and Monitor and other functions. RS-485 OUT to other GenesysTM Power Supplies. RS-232/RS-485 IN Remote Serial Programming. Wide-Range Input 85-265VAC continuous, 47/63Hz with Active Power Factor Correction (0.99 typical) AC Input Connector: IEC320. 7. Exit air assures reliable operation when zero stacked. 8. Output Connections: Rugged busbars for 6V up to 60V Output; Connector for Outputs >60V. 9. Optional Interface Position for IEEE 488.2 SCPI (shown) or Isolated Analog Interface or LAN Interface. 2 Genesys TM GENH750W Specifications 1.0 MODEL 1.Rated output voltage (*1) 2.Rated Output Current (*2) 3.Rated Output Power 4.Efficiency at 100/200Vac (*3) 1.1 CONSTANT VOLTAGE MODE 1.Max.line regulation ( 0.01% of Vo+ 2mV )(*4) 2.Max load regulation ( 0.01% of Vo+2mV )(*5) 3.Ripple and noise p-p 20MHz (*9) 4.Ripple r.m.s 5Hz~1MHz (*9) 5.Remote sense compensation/line 6.Temp. coefficient 7.Up-prog. response time, 0~Vo Rated 8.Down-prog response time full-load 9.Down-prog response time no-load 10.Transient response time (*8) 1.2 CONSTANT CURRENT MODE 1.Max.line regulation (0.01% of Io+ 2mA)(*4) 2.Max.load regulation (0.02% of Io+5mA)(*6) 3.Ripple r.m.s 5Hz~1MHz . (*7) 4.Temp. coefficient GENH V A W % mV mV mV mV V PPM/C mS mS mS mA mA mA PPM/C 6-100 6 100 600 76/78 8-90 8 90 720 78/81 12.5-60 12.5 60 750 81/84 20-38 20 38 760 82/85 30-25 30 25 750 82/85 40-19 40 19 760 83/87 60-12.5 60 12.5 750 83/87 80-9.5 80 9.5 760 83/87 100-7.5 100 7.5 750 83/87 300-2.5 300 2.5 750 83/87 600-1.3 600 1.3 780 83/87 32 32 150 25 5 62 62 300 60 5 2500 250 250 4000 2.5 6.0 18 2.25 5.5 13 2.13 5.26 8 5~165V 5~330V 5~660V 2.6 2.8 3.3 4 5 6 8 10 12 17 2.6 2.8 3.3 4 5 6 8 10 12 17 60 60 60 60 60 60 60 80 80 100 8 8 8 8 8 8 8 8 8 10 1 1 1 1 1.5 2 3 4 5 5 100PPM/C of rated output voltage,following 30 minutes warm up 150mS , N.L/F.L , resistive load 80mS , N.L/F.L , resistive load 10 50 80 150 500 600 700 800 900 1000 1100 1200 1500 2000 Less than 1mSec for models up to and including 100V. 2msec for models above 100V 12 11 8.0 5.8 4.5 3.9 3.25 25 23 17 12.6 10 8.8 7.5 200 180 120 76 63 48 38 100PPM/C from rated output current, following 30 minutes warm up 2.95 6.9 29 2.75 6.5 23 1.3 PROTECTIVE FUNCTIONS 1. OCP 2. OCP Foldback 3. OVP type 4. OVP trip point 5. Over Temp. Protection 0~105% Constant Current Output shut down when power supply change from CV to CC. User selectable. Inverter shut-down, manual reset by AC input recycle or by OUT button or by communication port 0.5~7.5V 0.5~10V 1~15V 1~24V 2~36V 2~44V 5~66V 5~88V 5~110V User selectable , latched or non latched 1.4 ANALOG PROGRAMMING AND MONITORING 1.Vout Voltage Programming 2.Iout Voltage Programming 3.Vout Resistor Programming 4.Iout Resistor Programming 5.On/Off control (rear panel) 6.Output Current monitor 7.Output Voltage monitor 8.Power Supply OK signal 9. CV/CC indicator 10. Enable/Disable 11. Local/Remote analog control 12. Local/Remote analog control indicator 0~100%, 0~5V or 0~10V, user select. Accuracy and linearity:+/-0.5% of rated Vout. 0~100%, 0~5V or 0~10V, user select. Accuracy and linearity:+/-1% of rated Iout. 0~100%, 0~5/10Kohm full scale,user select.,Accuracy and linearity:+/-1% of rated Vout. 0~100%, 0~5/10Kohm full scale,user select. Accuracy and linearity:+/-1.5% of rated Iout. By electrical. Voltage: 0~0.6V/2~15V,or dry contact ,user selectable logic 0~5V or 0~10V , accuracy:1% , user selectable 0~5V or 0~10V ,accuracy:1% ,user selectable TTL High=OK, 0V-Fail 500ohm impedance CV: TTL high (4~5V) source: 10mA, CC: TTL low (0~0.6V) sink current:10mA Dry contact. Open:off , Short: on. Max. voltage at Enable/Disable in: 6V By electrical signal or Open/Short: 0~0.6V or short: Remote analog, 4~5V or open: Local. Open collector, Local: Open, Remote: On. Maximum voltage: 30V, maximum sink current: 5mA. 1.5 FRONT PANEL 1.Control functions 150-5 150 5 750 83/87 Vout/ Iout manual adjust by separate encoders (coarse and fine adjustment selectable) OVP/UVL manual adjust by Volt. Adjust encoder AC on/off, Output on/off, Re-start modes (auto, safe), Foldback control (CV to CC), Go to local control Front Panel Lock Address selection by Voltage (or current) adjust encoder. Number of addresses:31 RS232/485 and IEEE488.2 selection by IEEE enable switch and DIP switch Baudrate selection: 1200,2400,4800,9600 and 19,200 Voltage 4 digits , accuracy: 0.5%+/-1 count Current 4 digits, accuracy: 0.5%+/-1 count Voltage, Current, Alarm, Fine, Preview, Foldback, Local, Output On, Front Panel Lock 2.Display 3.Indications 1.6 Interface RS-232&RS-485 or Optional GPIB / LAN Interface V Model 1. Remote Voltage Programming (16 bit) Resolution (0.012% of Vo Rated) mV Accuracy (0.05%Vo Rated+0.05% of Vo Actual Output) mV 6 8 12.5 20 30 40 60 80 100 150 300 600 0.72 6.0 0.96 8.0 1.50 12.5 2.40 20 3.60 30 4.80 40 7.2 60 9.6 80 12 100 18 150 36 300 72 600 2. Remote Current Programming (16 bit) Resolution (0.012% of Io Rated) Accuracy (0.1% of Io Rated+0.1% of Io Actual Output) mA mA 12 200 7.2 120 4.56 76 3.0 50 2.28 38 1.50 25 1.14 19 0.90 15 0.60 10 0.30 5.0 0.16 2.6 3. Readback Voltage Resolution (0.012% of Vo Rated) Accuracy (0.1%Vo Rated+0.1% of Vo Actual Output) mV mV 0.72 12 0.96 16 1.50 25 2.40 40 3.60 60 4.80 80 7.2 120 9.6 160 12 200 18 300 36 600 72 1200 4. Readback Current Resolution (0.012% of Io Rated ) mA Accuracy (0.3% of Io Rated+0.1% of Io Actual Output) mA 12 400 10.8 360 7.2 240 4.56 152 3.0 100 2.28 76 1.50 50 1.14 38 0.90 30 0.60 20 0.30 10 0.16 5.2 6 60 8 80 12 125 20 200 30 300 40 400 60 600 80 800 100 1000 150 1500 300 3000 600 6000 5. OVP/UVL Programming Resolution (0.1% of Vo Rated) Accuracy (1% of Vo Rated) mV mV 10.8 180 *1: Minimum voltage is guaranteed to maximum 0.2% of Vo Rated. *2: Minimum current is guaranteed to maximum 0.4% of Io Rated *3: At maximum output power. *4: 85~132Vac or 170~265Vac, constant load. *5: From No-load to Full-load, constant input voltage. *6: For load voltage change, equal to the unit voltage rating, constant input voltage. *7: For 6V models the ripple is measured at 2~6V output voltage and full output current. For other models, the ripple is measured at 10~100% output voltage and full output current. *8: Time for the output voltage to recover within 0.5% of its rated for a load change 10~90% of rated output current, Output set-point:10~100%. *9: For 6V~300V models: measured with JEITA RC-9131A 1:1 probe. For 600V model: measured with 10:1 probe Accuracy -Values have been calculated at Vo Rated & Io Rated 3 General Specifications GenesysTM GENH750W 2.1 INPUT CHARACTERISTICS 1. Input voltage/freq. (*1) 2. Power Factor 3. EN61000-3-2,3 compliance 4. Input current 100/200Vac 5. Inrush current 100/200Vac 6. Hold-up time 85~265Vac continuous, 47~63Hz, single phase 0.99 @100/200Vac, rated output power. Complies with EN61000-3-2 class A and EN61000-3-3 at 20~100% output power. 10.5A / 5A, Less than 25A, More than 20mS , 100Vac , at 100% load. 2.2 POWER SUPPLY CONFIGURATION 1. Parallel Operation 2. Series Operation Up to 4 units in master/slave mode with single wire current balance connection Up to 2 units. with external diodes. 600V Max to Chassis ground 2.3 ENVIRONMENTAL CONDITIONS 1. Operating temp 2. Storage temp 3. Operating humidity 4. Storage humidity 5. Vibration 6. Shock 7. Altitude 0~50C, 100% load. -20~70C 30~90% RH (non-condensing). 10~95% RH (non-condensing). MIL-810E, method 514.4 , test cond. I-3.3.1. The EUT is fixed to the vibrating surface. Less than 20G , half sine , 11mSec. Unit is unpacked. Operating: 10000ft (3000m), Derat output current by 2%/100m above 2000m, Non operating: 40000ft (12000m). 2.4 EMC 1.Applicable Standards: 2.ESD 3.Fast transients 4.Surge immunity 5.Conducted immunity 6.Radiated immunity 7.Conducted emission 8.Radiated emission 9.Voltage dips 10. Conducted emission 11. Radiated emission IEC1000-4-2. Air-disch.-8KV, contact disch.-4KV IEC1000-4-4. 2KV IEC1000-4-5. 1KV line to line, 2KV line to ground IEC1000-4-6, 3V IEC1000-4-3, 3V/m EN55022B,FCC part 15J-B,VCCI-B EN55022A,FCC part 15-A,VCCI-A EN61000-4-11 EN55022B, FCC part 15-B, VCCI-B. EN55022A, FCC part 15-A, VCCI-A. 2.5 SAFETY 1.Applicable standards: 3.Insulation resistance CE Mark, UL60950,EN60950 listed. Vout<60V:Output is SELV , IEEE/Isolated analog are SELV. 6060V. Exit air assures reliable operation when zero stacked. Wide-Range Input 85-265VAC continuous, 47/63Hz with Active Power Factor Correction (0.99 typical). AC Input Connector: 750W (IEC320), 1500W (screw terminal-shown). 9. Optional Interface Position for IEEE 488.2 SCPI (shown) or Isolated Analog Interface or LAN Interface. |2 Genesys TM 750W/1500W Specifications GEN V 1.0 MODEL 1.Rated output voltage(*1) 2.Rated Output Current(*2) 3.Rated Output Power 4.Efficiency at 100/200Vac (*3) A W % GEN V A W 1.0 MODEL 1.Rated output voltage (*1) 2.Rated Output Current (*2) 3.Rated Output Power 1.1 CONSTANT VOLTAGE MODE 1.Max.line regulation ( 0.01% of Vo+ 2mV )(*4) 2.Max load regulation ( 0.01% of Vo+2mV )(*5) 3.Ripple and noise p-p 20MHz (*9) 4.Ripple r.m.s 5Hz~1MHz (*9) 5.Remote sense compensation/line 6.Temp. coefficient 7.Up-prog. response time, 0~Vo Rated 8.Down-prog response time full-load 9.Down-prog response time no-load 10.Transient response time (*8) 1.2 CONSTANT CURRENT MODE 1.Max.line regulation (0.01% of Io+ 2mA)(*4) 2.Max.load regulation (0.02% of Io+5mA)(*6) 3.Ripple r.m.s 5Hz~1MHz . (*7) 4.Max.line regulation (0.01% of Io+ 2mA)(*4) 5.Max.load regulation (0.02% of Io+5mA)(*6) 6.Ripple r.m.s 5Hz~1MHz .(*7) 7.Temp. coefficient mV mV mV mV V PPM/C mS mS mS 750W 6-200 8-180 12.5-120 20-76 6 8 12.5 20 30-50 30 40-38 50-30 40 50 60-25 60 80-19 100-15 150-10 300-5 600-2.6 80 100 150 300 600 200 180 1200 1440 77/79 78/81 76 1520 83/86 50 1500 83/86 38 30 1520 1500 84/88 84/88 25 1500 84/88 19 1520 84/88 12.5-60 20-38 12.5 20 60 38 750 760 30-25 30 25 750 40-19 40 19 760 6-100 6 100 600 8-90 8 90 720 120 1500 81/84 --------- 15 1500 84/88 10 1500 84/88 5 1500 83/87 60-12.5 80-9.5 100-7.5 150-5 300-2.5 600-1.3 60 80 100 150 300 600 12.5 9.5 7.5 5 2.5 1.3 750 760 750 750 750 780 2.6 2.8 3.3 4 5 6 8 10 12 17 32 7 2.6 2.8 3.3 4 5 6 8 10 12 17 32 7 60 60 60 60 60 60 60 80 80 100 150 60 8 8 8 8 8 8 8 8 8 10 25 8 1 1 1 1 1.5 2 3 4 5 5 5 2 100PPM/C of rated output voltage,following 30 minutes warm up 150mS , N.L/F.L , resistive load 80mS , N.L/F.L , resistive load 10 50 150 80 600 800 900 1000 1100 1100 1200 1500 2000 2500 500 700 Less than 1mSec for models up to and including 100V. 2msec for models above 100V 8.0 4.5 3.25 2.95 11 5.8 mA 12 3.9 --17 10 7.5 6.9 23 12.6 mA 25 8.8 --120 63 38 29 180 76 mA 200 48 --14 7.0 4.5 3.9 20 9.6 mA 22 5.8 5 29 15 10 8.8 41 20.2 mA 45 12.6 11 240 125 75 57 360 152 mA 400 95 85 PPM/C 100PPM/C from rated output voltage,following 30 minutes warm up 2.75 6.5 23 3.5 8.0 45 2.5 6.0 18 3.0 7.0 35 2.25 5.5 13 2.5 6.0 25 2.13 5.26 8 2.26 5.52 12 X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X 0~100%, 0~5V or 0~10V, user select. Accuracy and linearity:+/-0.5% of rated Vout. 0~100%, 0~5V or 0~10V, user select. Accuracy and linearity:+/-1% of rated Iout. 0~100%, 0~5/10Kohm full scale,user select.,Accuracy and linearity:+/-1% of rated Vout. 0~100%, 0~5/10Kohm full scale,user select. Accuracy and linearity:+/-1.5% of rated Iout. By electrical. Voltage: 0~0.6V/2~15V,or dry contact ,user selectable logic 0~5V or 0~10V , accuracy:1% , user selectable 0~5V or 0~10V ,accuracy:1% ,user selectable TTL high (4~5V) -OK, 0V-Fail 500ohm series resistance CV: TTL high (4~5V) source: 10mA, CC: TTL low (0~0.6V), sink current: 10mA Dry contact. Open:off , Short: on. Max. voltage at Enable/Disable in: 6V By electrical signal or Open/Short: 0~0.6V or short: Remote, 4~5V or open: Local Open collector, Local: Open, Remote: On. Maximum voltage: 30V, maximum sink current: 5mA. X X X X X X X X X X X X X X X X X X X X X X X X Vout/ Iout manual adjust by separate encoders (coarse and fine adjustment selectable) OVP/UVL manual adjust by Volt. Adjust encoder AC on/off, Output on/off, Re-start modes (auto, safe), Foldback control (CV to CC), Go to local control Address selection by Voltage (or current) adjust encoder. Number of addresses:31 RS232/485 and IEEE488.2 selection by IEEE enable switch and DIP switch Baudrate selection: 1200,2400,4800,9600 and 19,200 Voltage 4 digits , accuracy: 0.5%+/-1 count Current 4 digits, accuracy: 0.5%+/-1 count Voltage, Current, Alarm, Fine, Preview, Foldback, Local, Output On, Front Panel Lock X X X X X X X X X X X X X X X X X X 1.4 ANALOG PROGRAMMING AND MONITORING 1.Vout Voltage Programming 2.Iout Voltage Programming 3.Vout Resistor Programming 4.Iout Resistor Programming 5.On/Off control (rear panel) 6.Output Current monitor 7.Output Voltage monitor 8.Power Supply OK signal 9. CV/CC indicator 10. Enable/Disable 11. Local/Remote analog control 12. Local/Remote analog control indicator 3.Indications 250 250 4000 X X X X X 0~105% Constant Current Output shut down when power supply change from CV to CC. User selectable. Inverter shut-down, manual reset by AC input recycle or by OUT button or by communication port. 0.5~7.5V 0.5~10V 1~15V 1~24V 2~36V 2~44V 5~57V 5~66V 5~88V 5~110V 5~165V 5~330V User selectable , latched or non latched 2.Display 62 62 300 60 5 X X X X X 1.3 PROTECTIVE FUNCTIONS 1. OCP 2. OCP Foldback 3. OVP type 4. OVP trip point 5. Over Temp. Protection 1.5 FRONT PANEL 1.Control functions 2.6 1560 83/87 1500W X X X X X 5~660V 1.6 Interface RS-232&RS-485 or Optional GPIB / LAN Interface V Model 1. Remote Voltage Programming (16 bit) Resolution (0.012% of Vo Rated) mV Accuracy (0.05%Vo Rated+0.05% of Vo Actual Output) mV 6 8 12.5 20 30 40 50 60 80 100 150 300 600 750W X 1500W X 0.72 6.0 0.96 8.0 1.50 12.5 2.40 20 3.60 30 4.80 40 6 50 7.2 60 9.6 80 12 100 18 150 36 300 72 600 X X X X 2. Remote Current Programming (16 bit) Resolution (0.012% of Io Rated) Accuracy (0.1% of Io Rated+0.1% of Io Actual Output) Resolution (0.012% of Io Rated) Accuracy (0.1% of Io Rated+0.1% of Io Actual Output) mA mA mA mA 12 200 24 400 10.8 180 21.6 360 7.2 120 14.4 240 4.56 76 9.12 152 3.0 50 6.0 100 2.28 38 4.56 76 ----3.60 60 1.50 25 3.0 50 1.14 19 2.28 38 0.90 15 1.80 30 0.60 10 1.20 20 0.30 5.0 0.60 10 0.16 2.6 0.32 5.2 X X 3. Readback Voltage Resolution (0.012% of Vo Rated) Accuracy (0.1%Vo Rated+0.1% of Vo Actual Output) mV mV 0.72 12 0.96 16 1.50 25 2.40 40 3.60 60 4.80 80 6.0 100 7.2 120 9.6 160 12 200 18 300 36 600 72 1200 X X 4. Readback Current Resolution (0.012% of Io Rated ) mA Accuracy (0.3% of Io Rated+0.1% of Io Actual Output) mA Resolution (0.012% of Io Rated ) mA Accuracy (0.3% of Io Rated+0.1% of Io Actual Output) mA 12 400 24 800 10.8 360 21.6 720 7.2 240 14.4 480 4.56 152 9.12 304 3.0 100 6 200 2.28 76 4.56 152 ----3.60 120 1.50 50 3.0 100 1.14 38 2.28 76 0.90 30 1.80 60 0.60 20 1.20 40 0.30 10 0.60 20 0.16 5.2 0.32 10.4 X X 6 60 8 80 12 125 20 200 30 300 40 400 50 500 60 600 80 800 100 1000 150 1500 300 3000 600 6000 X X 5. OVP/UVL Programming Resolution (0.1% of Vo Rated) Accuracy (1% of Vo Rated) mV mV X X X X X X X X *1: Minimum voltage is guaranteed to maximum 0.2% of Vo Rated. *3: At maximum output power. *5: From No-load to Full-load, constant input voltage. *2: Minimum current is guaranteed to maximum 0.4% of Io Rated *4: 85~132Vac or 170~265Vac, constant load. *6: For load voltage change, equal to the unit voltage rating, constant input voltage. *7: For 6V models the ripple is measured at 2~6V output voltage and full output current. For other models, the ripple is measured at 10~100% output voltage and full output current. *8: Time for the output voltage to recover within 0.5% of its rated for a load change 10~90% of rated output , Output set-point:10~100%. *9 For 6V~300V models: measured with JEITA RC-9131A 1:1 probe. For 600V model: measured with 10:1 probe Accuracy -Values have been calculated at Vo Rated & Io Rated 3|GenesysTM 750W/1500W-1U General Specifications GenesysTM 750W/1500W 2.1 INPUT CHARACTERISTICS 1. Input voltage/freq. (*1) 2. Power Factor 3. EN61000-3-2,3 compliance 4. Input current 100/200Vac 5. Inrush current 100/200Vac 6. Hold-up time 85~265Vac continuous, 47~63Hz, single phase 0.99 @100/200Vac, rated output power. Complies with EN61000-3-2 class A and EN61000-3-3 at 20~100% output power. 750W :10.5A / 5A, 1500W :21A / 11A 750W :Less than 25A, 1500W :Less than 50A More than 20mS , 100Vac , at 100% load. 2.2 POWER SUPPLY CONFIGURATION 1. Parallel Operation 2. Series Operation Up to 4 units in master/slave mode with single wire current balance connection Up to 2 units. with external diodes. 600V Max to Chassis ground 2.3 ENVIRONMENTAL CONDITIONS 1. Operating temp 2. Storage temp 3. Operating humidity 4. Storage humidity 5. Vibration 6. Shock 7. Altitude 0~50C, 100% load. -20~70C 30~90% RH (non-condensing). 10~95% RH (non-condensing). MIL-810E, method 514.4 , test cond. I-3.3.1. The EUT is fixed to the vibrating surface. Less than 20G , half sine , 11mSec. Unit is unpacked. Operating: 10000ft (3000m), Derat output current by 2%/100m abouve 2000m, Non operating: 40000ft (12000m). 2.4 EMC 1.Applicable Standards: 2.ESD 3.Fast transients 4.Surge immunity 5.Conducted immunity 6.Radiated immunity 7.Conducted emission 8.Radiated emission 9.Voltage dips 10. Conducted emission 11. Radiated emission IEC1000-4-2. Air-disch.-8KV, contact disch.-4KV IEC1000-4-4. 2KV IEC1000-4-5. 1KV line to line, 2KV line to ground IEC1000-4-6, 3V IEC1000-4-3, 3V/m EN55022B,FCC part 15J-B, VCCI-B. EN55022A,FCC part 15-A, VCCI-A. EN61000-4-11 EN55022B, FCC part 15-B, VCCI-B. EN55022A, FCC part 15-A, VCCI-A. 2.5 SAFETY 1.Applicable standards: 2.Withstand voltage 3.Insulation resistance 2.6 MECHANICAL CONSTRUCTION 1. Cooling 2. Dimensions (WxHxD) 3. Weight 4. AC Input connector CE Mark, UL60950,EN60950 listed. Vout<60V:Output is SELV , IEEE/Isolated analog are SELV. 60100V. Exit air assures reliable operation when zero stacked. Input: 230VAC Single Phase (shown), 208 VAC Three Phase, 50/60 Hz AC Input Connector: Phoenix P/N: FRONT-4-H-7.62. 9. Optional Interface Position for IEEE 488.2 SCPI (shown) or Isolated Analog Interface or LAN Interface. 10. Auxiliary Output Voltage. |2 Genesys TM 2.4kW Specifications 1.0 MODEL 1.Rated output voltage(*1) GEN V 2.Rated Output Current(*2) 3.Rated Output Power 4.Development Priority A W --- 8-300 8 300 2400 A 10-240 10 240 2400 C 16-150 16 150 2400 B 20-120 20 120 2400 C 30-80 30 80 2400 B 40-60 40 60 2400 B 60-40 60 40 2400 A 80-30 80 30 2400 C 100-24 100 24 2400 C 150-16 150 16 2400 A 300-8 300 8 2400 B 600-4 600 4 2400 A 8 10 12 17 2.8 3 3.6 4 5 6 14 17 20 27.5 6.2 6.5 7.4 8 9.5 11 60 80 80 100 60 60 60 60 60 60 8 8 8 25 8 8 8 8 8 8 5 5 5 5 2 2 2 2 5 5 100PPM/C of rated output voltage,following 30 minutes warm-up 0.05% of rated Vout over 8hrs interval following 30 minutes warm-up. Constant line, load & temp. Less than 0.05% of rated output voltage+2mV over 30 minutes following power On. 15mS 60mS 30mS 80 10 30 1100 1200 1500 2500 600 800 900 1000 500 700 Time for output voltage to recover within 0.5% of its rated output for a load change 10-90% of rated output current. Output set-point: 10-100%, local sense. Less than 1mSec for models up to and including 100V. 2msec for models above 100V 32 50 150 35 5 62 95 300 75 5 6 5 4.4 3.6 32 26 17 14 10 8 13 11 9.8 8.2 65 53 35 29 21 17 70 50 40 30 1200 960 600 480 220 120 100PPM/C from rated output current, following 30 minutes warm-up. 0.05% of rated Iout over 8hrs. interval following 30minutes warm-up. Constant line, load & temperature. 8V~20V models: Less than 0.5% of rated output current over 30 minutes following power On. 30V~600V models: Less than 0.25% of rated output current over 30 minutes following power On. 2.8 6.6 15 1.1 CONSTANT VOLTAGE MODE mV 1.Max.line regulation (0.01% of rated Vo+2mV)(*6) mV 2.Max load regulation (0.015% of rated Vo+5mV)(*7) mV 3.Ripple and noise p-p 20MHz (*8) mV 4.Ripple r.m.s 5Hz~1MHz V 5.Remote sense compensation/wire PPM/C 6.Temp. coefficient 7.Temp. stability 8.Warm-up drift mS 9.Up-prog. response time, 0~Vo Rated (*9) mS Full-load (*9) 10.Down-prog response time mS No-load (*10) mS 11.Transient response time 1.2 CONSTANT CURRENT MODE 1.Max.line regulation (0.01% of Io rated+2mA)(*6) 2.Max.load regulation (0.02% of Io rated+5mA)(*11) 3.Ripple r.m.s 5Hz~1MHz. (*12) 4.Temp. coefficient 5.Temp. stability 6.Warm-up drift mA mA mA PPM/C 1.3 PROTECTIVE FUNCTIONS 1. OCP 2. OCP Foldback 3. OVP type 4. OVP trip point 5. Output Under Voltage Limit 6. Over Temp. Protection 100mS 100 3000 0~105% Constant Current Output shut down when power supply change from CV to CC. User selectable. Inverter shut-down, manual reset by AC input recycle or by OUT button or by communication port command. 5~66V 0.5~10V 0.5~12V 1~19V 1~24V 2~36V 2~44V 5~88V 5~110V 5~165V 5~330V Preset by front panel or communication port. Prevents from adjusting Vout below limit. User selectable , latched or non-latched. 1.4 ANALOG PROGRAMMING AND MONITORING 1.Vout Voltage Programming 2.Iout Voltage Programming (*13) 3.Vout Resistor Programming 4.Iout Resistor Programming (*13) 5.On/Off control (rear panel) 6.Output Current monitor (*13) 7.Output Voltage monitor 8.Power Supply OK signal 9. CV/CC Indicator 10. Enable/Disable 11. Local/Remote analog control 12. Local/Remote analog control Indicator 2.4 5.8 7 5~660V 0~100%, 0~5V or 0~10V, user select. Accuracy and linearity:0.5% of rated Vout. 0~100%, 0~5V or 0~10V, user select. Accuracy and linearity:1% of rated Iout. 0~100%, 0~5/10Kohm full scale,user select.,Accuracy and linearity: 1% of rated Vout. 0~100%, 0~5/10Kohm full scale,user select. Accuracy and linearity:1.5% of rated Iout. By electrical. Voltage: 0~0.6V/2~15V,or dry contact ,user selectable logic. 0~5V or 0~10V , Accuracy:1% , user selectable. 0~5V or 0~10V ,Accuracy:1% ,user selectable. TTL high (4~5V) -OK, 0V-Fail 500ohm series resistance. Open collector, CC mode: On, CV mode: Off, Maximum voltage: 30V, maximum sink current: 10mA Dry contact. Open:off , Short: on. Max. voltage at Enable/Disable in: 6V. By electrical signal or Open/Short: 0~0.6V or short: Remote, 2~15V or open: Local. Open collector, Local: Off, Remote: On. Maximum voltage: 30V, maximum sink current: 10mA. 1.5 FRONT PANEL 1.Control functions Vout/ Iout manual adjust by separate encoders (coarse and fine adjustment selectable). OVP/UVL manual adjust by Volt. Adjust encoder. On/Off, Output on/off, Re-start modes (auto, safe), Foldback control (CV to CC), Go to local control. Address selection by Voltage (or current) adjust encoder. Number of addresses:31. Re-start modes (automatic restart, safe mode). Baud rate selection: 1200,2400,4800,9600 and 19,200. Voltage: 4 digits , Accuracy: 0.5% of rated output Voltage 1 count. Current: 4 digits, Accuracy: 0.5% of rated output current 1 count. Voltage, Current, Alarm, Fine, Preview, Foldback, Local, Output On, Front Panel Lock, CV/CC. 2.Display 3.Indications 1.6 Interface RS-232&RS-485 or Optional GPIB / LAN Interface Model 1. Remote Voltage Programming (16 bit) Resolution (0.012% of Vo Rated) Accuracy (0.05%Vo Rated+0.05% of Vo Actual Output) V 8 10 16 20 30 40 60 80 100 150 300 600 mV mV 0.96 8 1.2 10 1.92 16 2.4 20 3.6 30 4.8 40 7.2 60 9.6 80 12 100 18 150 36 300 72 600 2. Remote Current Programming (16 bit) Resolution (0.012% of Io Rated) Accuracy (0.2% of Io Rated+0.1% of Io Actual Output) (*13) mA mA 36 900 28.8 720 18 450 14.4 360 9.6 240 7.2 180 4.8 120 3.6 90 2.88 72 1.92 48 0.96 24 0.48 12 3. Readback Voltage Resolution (0.012% of Vo Rated) Accuracy (0.1%Vo Rated+0.1% of Vo Actual Output) mV mV 0.96 16 1.2 20 1.92 32 2.4 40 3.6 60 4.8 80 7.2 120 9.6 160 12 200 18 300 36 600 72 1200 4. Readback Current Resolution (0.012% of Io Rated ) Accuracy (0.3% of Io Rated+0.1% of Io Actual Output) (*13) mA mA 36 1200 28.8 960 18 600 14.4 480 9.6 320 7.2 240 4.8 160 3.6 120 2.88 96 1.92 64 0.96 32 0.48 16 5. OVP/UVL Programming Resolution (0.1% of Vo Rated) Accuracy (1% of Vo Rated) mV mV 8 80 10 100 16 160 20 200 30 300 40 400 60 600 80 800 100 1000 150 1500 300 3000 600 6000 *1: Minimum voltage is guaranteed to maximum 0.2% of rated output voltage. *2: Minimum current is guaranteed to maximum 0.4% of rated output current. *3: For cases where conformance to various safety standards (UL, IEC, etc) is required, to be described as 190-240Vac (50/60Hz) for 3-Phase 208V models. *4: 3-Phase 208V models: At 208Vac input voltage. With rated output power. *5: Not including EMI filter inrush current, less than 0.2mSec. *6: 3-Phase 208V models: 170~265Vac, constant load. *7: From No-Load to Full-Load, constant input voltage. Maximum drop in Remote Sense. *8: For 8V~300V models: Measured with JEITA RC-9131A (1:1) probe. For 600V model: Measured with 10:1 probe. 3|GenesysTM 2.4kW-1U *9: From 10% to 90% or 90% to 10% of Rated Output Voltage, with rated, resistive load. *10:From 90% to 10% of Rated Output Voltage. *11: For load voltage change, equal to the unit voltage rating, constant input voltage. *12: For 8V~16V models the ripple is measured from 2V to rated output voltage and rated output current. For other models, the ripple is measured at 10~100% of rated output voltage and rated output current. *13: The Constant Current programming readback and monitoring accuracy does not include the warm-up and Load regulation thermal drift. General Specifications GenesysTM 2.4kW 2.1 INPUT CHARACTERISTICS 1. Input voltage/freq. (*3) GEN VAC 2. Maximum Input current at 100% load Single Phase,230V models: 3-Phase, 208V models: 3. Power Factor (Typ) 4. Efficiency (*4) 5. Inrush Current (*5) 6. Hold-up time (Typ) A % A mS 8-300 10-240 16-150 20-120 30-80 40-60 60-40 80-30 100-24 150-16 Single Phase,230V models: 170~265Vac, 47~63Hz 3-Phase, 208V models: 170~265Vac, 47~63Hz 17 17 17 16.3 16.3 16.3 16.3 16.3 16.3 16.3 10.5 10.5 10.5 9.8 9.8 9.8 9.8 9.8 9.8 9.8 Single Phase models: 0.99@230Vac, rated output power. 3-Phase models: 0.94@208 Vac, rated output power. 84 84 84 86 86 88 88 88 88 88 Single-Phase and 3-Phase 208V models: Less than 50A 10mSec for Single-Phase and 3-phase 208V models. Rated output power. 2.2 AUXILIARY OUTPUT 1. 15V output 2. 5V output 15V5%, 0.2A Max load, Ripple & Noise 50mVp-p. Referenced internally to the negative output potential. 5V5%, 0.2A Max load, Ripple & Noise 50mVp-p. Referenced internally to IF_com potential. 2.3 POWER SUPPLY CONFIGURATION 1. Parallel Operation 2. Series Operation Up to 4 identical units in master/slave mode Up to 2 identical units. with external diodes. 600V Max to Chassis ground 2.4 ENVIRONMENTAL CONDITIONS 1. Operating temp 2. Storage temp 3. Operating humidity 4. Storage humidity 5. Vibration 6. Shock 7. Altitude 8. RoHS Compliance 2.5 EMC 1.Applicable Standards: 2.ESD 3.Fast transients 4.Surge immunity 5.Conducted immunity 6.Radiated immunity 7.Magnetic field immunity 8.Voltage dips 9.Conducted emission 10. Radiated emission 2.6 SAFETY 1.Applicable standards: 2.Withstand voltage 3.Insulation resistance 2.7 MECHANICAL CONSTRUCTION 1. Cooling 2. Dimensions (WxHxD) 3. Weight 4. AC Input connector (with Protective Cover) 5.Output connectors 300-8 600-4 16.3 9.8 16.3 9.8 88 88 0~50C, 100% load. -20~85C 20~90% RH (non-condensing). 10~95% RH (non-condensing). MIL-810F, method 514.5 , The EUT is fixed to the vibrating surface. Less than 20G , half sine , 11mSec. Unit is unpacked. Operating: 10000ft (3000m), Derate output current by 2%/100m above 2000m, Alternatively, derate maximum ambient temp. by 1C/100m above 2000m. Non operating: 40000ft (12000m). Complies with the requirements of RoHS directive. IEC1000-4-2. Air-disch.-8KV, contact disch.-4KV IEC1000-4-4. 2KV IEC1000-4-5. 1KV line to line, 2KV line to ground IEC1000-4-6, 3V IEC1000-4-3, 3V/m EN61000-4-8, 1A/m EN61000-4-11 EN55022A, FCC part 15-A, VCCI-A. EN55022A, FCC part 15-A, VCCI-A. CE Mark, UL60950,EN60950 listed. Vout40V:Output is SELV , IEEE/Isolated analog are SELV. 40100V. Exit air assures reliable operation when zero stacked. Input: 230VAC Single Phase (shown), 208 & 400VAC Three Phase, 50/60 Hz AC Input Connector: PHOENIX CONTACT Power Combicon PC 6/... Series with strain relief. 9. Optional Interface Position for IEEE 488.2 SCPI (shown) or Isolated Analog Interface or LAN Interface. |2 Genesys TM 3.3kW Specifications 1.0 MODEL 1.Rated output voltage(*1) 2.Rated Output Current(*2) 3.Rated Output Power GEN V 8-400 8 10-330 10 15-220 15 20-165 20 30-110 30 40-85 40 60-55 60 80-42 80 100-33 100 150-22 150 300-11 300 600-5.5 600 A W 400 3200 330 3300 220 3300 165 3300 110 3300 85 3400 55 3300 42 3360 33 3300 22 3300 11 3300 5.5 3300 32 50 150 35 5 62 95 500 120 5 3500 250 500 4000 3.1 7.2 50 2.6 6.1 10 1.1 CONSTANT VOLTAGE MODE mV 1.Max.line regulation ( 0.01% of rated Vo+ 2mV )(*6) mV 2.Max load regulation ( 0.015% of rated Vo+5mV )(*7) mV 3.Ripple and noise p-p 20MHz (*8) mV 4.Ripple r.m.s 5Hz~1MHz V 5.Remote sense compensation/wire PPM/C 6.Temp. coefficient 7.Temp. stability 8.Warm-up drift mS 9.Up-prog. response time, 0~Vo Rated (*9) mS Full-load (*9) 10.Down-prog response time mS No-load (*10) mS 11.Transient response time 1.2 CONSTANT CURRENT MODE 1.Max.line regulation (0.01% of rated Io+ 2mA)(*6) 2.Max.load regulation (0.02% of rated Io+5mA)(*11) 3.Ripple r.m.s 5Hz~1MHz . (*12) 4.Load regulation thermal drift 5.Temp. coefficient 6.Temp. stability 7.Warm-up drift mA mA mA PPM/C 1.3 PROTECTIVE FUNCTIONS 1. OCP 2. OCP Foldback 3. OVP type 4. OVP trip point 5. Output Under Voltage Limit 6. Over Temp. Protection 2.8 3 3.5 4 5 6 10 12 17 8 6.2 6.5 7.25 8 9.5 11 17 20 27.5 14 60 60 60 60 60 60 80 80 100 60 8 8 8 8 8 8 8 8 25 8 2 2 2 2 5 5 5 5 5 5 100PPM/C of rated output voltage,following 30 minutes warm-up 0.05% of rated Vout over 8hrs interval following 30 minutes warm-up. Constant line, load & temp. Less than 0.05% of rated output voltage+2mV over 30 minutes following power On. 150 80 160 300 20 100 500 600 700 800 900 1000 1200 1500 2000 1100 Time for output voltage to recover within 0.5% of its rated output for a load change 10-90% of rated output current. Output set-point: 10-100%, local sense. Less than 1mSec for models up to and including 100V. 2msec for models above 100V 42 35 24 18.5 13 10.5 6.2 5.3 4.2 7.5 85 71 49 38 27 22 13.4 11.6 9.4 16 1300 660 440 300 250 200 120 90 60 100 Less than 0.1% of rated output current over 30 minutes following load change. 200PPM/C from rated output current, following 30 minutes warm-up. 0.05% of rated Iout over 8hrs. interval following 30minutes warm-up. Constant line, load & temperature. 8V~40V models: Less than 0.5% of rated output current over 30 minutes following power On. 60V~600V models: Less than 0.25% of rated output current over 30 minutes following power On. 0~105% Constant Current Output shut down when power supply change from CV to CC. User selectable. Inverter shut-down, manual reset by AC input recycle or by OUT button or by communication port command. 0.5~10V 0.5~12V 1~18V 1~24V 2~36V 2~44V 5~88V 5~110V 5~165V 5~330V 5~66V Preset by front panel or communication port. Prevents from adjusting Vout below limit. User selectable , latched or non-latched. 1.4 ANALOG PROGRAMMING AND MONITORING 1.Vout Voltage Programming 2.Iout Voltage Programming (*13) 3.Vout Resistor Programming 4.Iout Resistor Programming (*13) 5.On/Off control (rear panel) 6.Output Current monitor (*13) 7.Output Voltage monitor 8.Power Supply OK signal 9. CV/CC Indicator 10. Enable/Disable 11. Local/Remote analog control 12. Local/Remote analog control Indicator 5~660V 0~100%, 0~5V or 0~10V, user select. Accuracy and linearity:0.5% of rated Vout. 0~100%, 0~5V or 0~10V, user select. Accuracy and linearity:1% of rated Iout. 0~100%, 0~5/10Kohm full scale,user select.,Accuracy and linearity: 1% of rated Vout. 0~100%, 0~5/10Kohm full scale,user select. Accuracy and linearity:1.5% of rated Iout. By electrical. Voltage: 0~0.6V/2~15V,or dry contact ,user selectable logic. 0~5V or 0~10V , Accuracy:1% , user selectable. 0~5V or 0~10V ,Accuracy:1% ,user selectable. TTL high (4~5V) -OK, 0V-Fail 500ohm series resistance. CV: TTL high (4~5V) source: 10mA, CC: TTL low (0~0.6V), sink current: 10mA. Dry contact. Open:off , Short: on. Max. voltage at Enable/Disable in: 6V. By electrical signal or Open/Short: 0~0.6V or short: Remote, 4~5V or open: Local. Open collector, Local: Off, Remote: On. Maximum voltage: 30V, maximum sink current: 10mA. 1.5 FRONT PANEL 1.Control functions Vout/ Iout manual adjust by separate encoders (coarse and fine adjustment selectable). OVP/UVL manual adjust by Volt. Adjust encoder. On/Off, Output on/off, Re-start modes (auto, safe), Foldback control (CV to CC), Go to local control. Address selection by Voltage (or current) adjust encoder. Number of addresses:31. Re-start modes (automatic restart, safe mode). Baud rate selection: 1200,2400,4800,9600 and 19,200. Voltage: 4 digits , Accuracy: 0.5% of rated output Voltage 1 count. Current: 4 digits, Accuracy: 0.5% of rated output current 1 count. Voltage, Current, Alarm, Fine, Preview, Foldback, Local, Output On, Front Panel Lock, CVCC. 2.Display 3.Indications 1.6 Interface RS-232&RS-485 or Optional GPIB / LAN Interface Model 1. Remote Voltage Programming (16 bit) Resolution (0.012% of Vo Rated) Accuracy (0.05%Vo Rated+0.05% of Vo Actual Output) V 8 10 15 20 30 40 60 80 100 150 300 600 mV mV 0.96 8 1.2 10 1.8 15 2.40 20 3.60 30 4.80 40 7.2 60 9.6 80 12 100 18 150 36 300 72 600 2. Remote Current Programming (16 bit) Resolution (0.012% of Io Rated) Accuracy (0.2% of Io Rated+0.1% of Io Actual Output) (*13) mA mA 48 1200 39.6 990 26.4 660 19.8 495 13.2 330 10.2 255 6.6 165 5.0 126 4.0 99 2.6 66 1.3 33 0.7 16.5 3. Readback Voltage Resolution (0.012% of Vo Rated) Accuracy (0.1%Vo Rated+0.1% of Vo Actual Output) mV mV 0.96 16 1.2 20 1.8 30 2.40 40 3.60 60 4.80 80 7.2 120 9.6 160 12 200 18 300 36 600 72 1200 4. Readback Current Resolution (0.012% of Io Rated ) Accuracy (0.3% of Io Rated+0.1% of Io Actual Output) (*13) mA mA 48 1600 39.6 1320 26.4 880 19.8 660 13.2 440 10.2 340 6.6 220 5.0 168 4.0 132 2.6 88 1.3 44 0.7 22 5. OVP/UVL Programming Resolution (0.1% of Vo Rated) Accuracy (1% of Vo Rated) mV mV 8 80 10 100 15 150 20 200 30 300 40 400 60 600 80 800 100 1000 150 1500 300 3000 600 6000 *1: Minimum voltage is guaranteed to maximum 0.2% of rated output voltage. *2: Minimum current is guaranteed to maximum 0.4% of rated output current. *3: For cases where conformance to various safety standards (UL, IEC, etc) is required, to be described as 190-240Vac (50/60Hz) for single phase and 3-Phase 208V models, and 380~415Vac (50/60Hz) for 3-Phase 400V models. *4: Single-Phase and 3-Phase 208V models: At 208Vac input voltage, 3-Phase 400V: At 380Vac input voltage. With rated output power. *5: Not including EMI filter inrush current, less than 0.2mSec. *6: Single-Phase and 3-Phase 208V models: 170~265Vac, constant load. 3-Phase 400V models: 342~460Vac, constant load. 3|GenesysTM 3.3kW-2U *7: From No-Load to Full-Load, constant input voltage. Maximum drop in Remote Sense. *8: For 8V~300V models: Measured with JEITA RC-9131A (1:1) probe. For 600V model: Measured with 10:1 probe. *9: From 10% to 90% or 90% to 10% of Rated Output Voltage, with rated, resistive load. *10:From 90% to 10% of Rated Output Voltage. *11: For load voltage change, equal to the unit voltage rating, constant input voltage. *12: For 8V~15V models the ripple is measured from 2V to rated output voltage and rated output current. For other models, the ripple is measured at 10~100% of rated output voltage and rated output current. *13: The Constant Current programming readback and monitoring accuracy does not include the warm-up and Load regulation thermal drift. General Specifications GenesysTM 3.3kW 2.1 INPUT CHARACTERISTICS 1. Input voltage/freq. (*3) GEN VAC 2. Maximum Input current at 100% load Single Phase,230V models: 3-Phase, 208V models: 3-Phase, 400V models: A 3. Power Factor (Typ) 4. Efficiency (*4) 5. Inrush Current (*5) % A 6. Hold-up time (Typ) mS 2.2 POWER SUPPLY CONFIGURATION 1. Parallel Operation 2. Series Operation 2.3 ENVIRONMENTAL CONDITIONS 1. Operating temp 2. Storage temp 3. Operating humidity 4. Storage humidity 5. Vibration 6. Shock 7. Altitude 8. RoHS Compliance 8-400 10-330 15-220 20-165 30-110 40-85 60-55 80-42 100-33 150-22 300-11 Single Phase,230V models: 170~265Vac, 47~63Hz 3-Phase, 208V models: 170~265Vac, 47~63Hz 3-Phase, 400V models: 342~460Vac, 47~63Hz 24 24 24 24 24 24 23 23 23 23 23 15 15 15 15 15 15 14.5 14.5 14.5 14.5 14.5 7.5 7.5 7.5 7.5 7.5 7.5 7 7 7 7 7 Single Phase models: 0.99@230Vac, rated output power. 3-Phase models: 0.94@208/380Vac, rated output power. 82 84 84 86 86 88 88 88 88 88 88 Single-Phase and 3-Phase 208V models: Less than 50A 3-Phase 400V models: Less than 20A 10mSec for Single-Phase and 3-phase 208V models, 6mSec for 3-Phase 400V models. Rated output power. 600-5.5 23 14.5 7 87 Up to 4 identical units in master/slave mode Up to 2 identical units. with external diodes. 600V Max to Chassis ground 0~50C, 100% load. -30~85C 20~90% RH (non-condensing). 10~95% RH (non-condensing). MIL-810F, method 514.5 , The EUT is fixed to the vibrating surface. Less than 20G , half sine , 11mSec. Unit is unpacked. Operating: 10000ft (3000m), Derate output current by 2%/100m above 2000m, Alternatively, derate maximum ambient temp. by 1C/100m above 2000m. Non operating: 40000ft (12000m). Complies with the requirements of RoHS directive. 2.4 EMC 1.Applicable Standards: 2.ESD 3.Fast transients 4.Surge immunity 5.Conducted immunity 6.Radiated immunity 7.Magnetic field immunity 8.Voltage dips 9.Conducted emission 10. Radiated emission IEC1000-4-2. Air-disch.-8KV, contact disch.-4KV IEC1000-4-4. 2KV IEC1000-4-5. 1KV line to line, 2KV line to ground IEC1000-4-6, 3V IEC1000-4-3, 3V/m EN61000-4-8, 1A/m EN61000-4-11 EN55022A, FCC part 15-A, VCCI-A. EN55022A, FCC part 15-A, VCCI-A. 2.5 SAFETY 1.Applicable standards: CE Mark, UL60950,EN60950 listed. Vout40V:Output is SELV , IEEE/Isolated analog are SELV. 40100V. Exit air assures reliable operation when zero stacked. Input: 208 & 400VAC Three Phase, 50/60 Hz AC Input Connector: PHOENIX CONTACT Power Combicon PC 6/... Series with strain relief. 9. Optional Interface Position for IEEE 488.2 SCPI (shown) or Isolated Analog Interface or LAN Interface. |2 Genesys TM 5kW Specifications 1.0 MODEL 1.Rated output voltage(*1) 2.Rated Output Current(*2) 3.Rated Output Power 4.Development Priority GEN V A W --- 8-600 8 600 4800 A 10-500 10 500 5000 C 16-310 16 310 4960 B 20-250 20 250 5000 C 30-170 30 170 5100 B 40-125 40 125 5000 B 60-85 60 85 5100 A 80-65 80 65 5200 C 100-50 100 50 5000 C 150-34 150 34 5100 A 300-17 300 17 5100 B 600-8.5 600 8.5 5100 A 30 50 300 35 5 60 95 500 120 5 2500 100 200 3000 1.1 CONSTANT VOLTAGE MODE mV 1.Max.line regulation (0.01% of rated Vo)(*6) mV 2.Max load regulation (0.015% of rated Vo+5mV)(*7) mV 3.Ripple and noise p-p 20MHz (*8) mV 4.Ripple r.m.s 5Hz~1MHz V 5.Remote sense compensation/wire PPM/C 6.Temp. coefficient 7.Temp. stability 8.Warm-up drift mS 9.Up-prog. response time, 0~Vo Rated (*9) mS Full-load (*9) 10.Down-prog response time mS No-load (*10) mS 11.Transient response time 1.2 CONSTANT CURRENT MODE 1.Max.line regulation (0.05% of Io rated)(*6) 2.Max.load regulation (0.1% of Io rated)(*11) 3.Ripple r.m.s 5Hz~1MHz. (*12) 4.Temp. coefficient 5.Temp. stability 6.Warm-up drift mA mA mA PPM/C 1.3 PROTECTIVE FUNCTIONS 1. OCP 2. OCP Foldback 3. OVP type 4. OVP trip point 5. Output Under Voltage Limit 6. Over Temp. Protection 0.8 1.0 1.6 2 3 4 8 10 15 6 6.2 6.5 7.4 8 9.5 11 17 20 27.5 14 75 75 75 75 75 75 85 100 120 75 10 10 10 10 10 10 12 15 25 10 2 2 2 2 5 5 5 5 5 5 100PPM/C of rated output voltage,following 30 minutes warm-up 0.05% of rated Vout over 8hrs interval following 30 minutes warm-up. Constant line, load & temp. Less than 0.05% of rated output voltage+2mV over 30 minutes following power On. 50mS 30mS 80 100 15 50 400 500 600 700 800 900 1200 1500 2000 1000 Time for output voltage to recover within 0.5% of its rated output for a load change 10-90% of rated output current. Output set-point: 10-100%, local sense. Less than 1mSec for models up to and including 100V. 2msec for models above 100V 300 250 155 125 85 62.5 32.5 25 17 42.5 600 500 310 250 170 125 65 50 34 58 1950 1800 1400 1000 460 300 120 100 90 150 100PPM/C from rated output current, following 30 minutes warm-up. 0.05% of rated Iout over 8hrs. interval following 30minutes warm-up. Constant line, load & temperature. 8V~16V models: Less than 0.5% of rated output current over 30 minutes following power On. 20V~600V models: Less than 0.25% of rated output current over 30 minutes following power On. 8.5 17 30 4.25 8.5 15 0~105% Constant Current Output shut down when power supply change from CV to CC. User selectable. Inverter shut-down, manual reset by AC input recycle or by OUT button or by communication port command. 0.5~10V 0.5~12V 1~19V 1~24V 2~36V 2~44.1V 5~66.15V 5~88.2V 5~110.25V 5~165.3V 5~330.7V 5~661.5V Preset by front panel or communication port. Prevents from adjusting Vout below limit. User selectable , latched or non-latched. 1.4 ANALOG PROGRAMMING AND MONITORING 1.Vout Voltage Programming 2.Iout Voltage Programming (*13) 3.Vout Resistor Programming 4.Iout Resistor Programming (*13) 5.On/Off control (rear panel) 6.Output Current monitor (*13) 7.Output Voltage monitor 8.Power Supply OK signal 9. CV/CC Indicator 10. Enable/Disable 11. Local/Remote analog control 12. Local/Remote analog control Indicator 0~100%, 0~5V or 0~10V, user select. Accuracy and linearity:0.5% of rated Vout. 0~100%, 0~5V or 0~10V, user select. Accuracy and linearity:1% of rated Iout. 0~100%, 0~5/10Kohm full scale,user select.,Accuracy and linearity: 1% of rated Vout. 0~100%, 0~5/10Kohm full scale,user select. Accuracy and linearity:1.5% of rated Iout. By electrical. Voltage: 0~0.6V/2~15V,or dry contact ,user selectable logic. 0~5V or 0~10V , Accuracy:1% , user selectable. 0~5V or 0~10V ,Accuracy:1% ,user selectable. TTL high (4~5V) -OK, 0V-Fail 500ohm series resistance. Open collector, CC mode: On, CV mode: Off, Maximum voltage: 30V, maximum sink current: 10mA Dry contact. Open:off , Short: on. Max. voltage at Enable/Disable in: 6V. By electrical signal or Open/Short: 0~0.6V or short: Remote, 2~15V or open: Local. Open collector, Local: Off, Remote: On. Maximum voltage: 30V, maximum sink current: 10mA. 1.5 FRONT PANEL 1.Control functions Vout/ Iout manual adjust by separate encoders (coarse and fine adjustment selectable). OVP/UVL manual adjust by Volt. Adjust encoder. On/Off, Output on/off, Re-start modes (auto, safe), Foldback control (CV to CC), Go to local control. Address selection by Voltage (or current) adjust encoder. Number of addresses:31. Re-start modes (automatic restart, safe mode). Baud rate selection: 1200,2400,4800,9600 and 19,200. Voltage: 4 digits , Accuracy: 0.5% of rated output Voltage 1 count. Current: 4 digits, Accuracy: 0.5% of rated output current 1 count. Voltage, Current, Alarm, Fine, Preview, Foldback, Local, Output On, Front Panel Lock, CV/CC. 2.Display 3.Indications 1.6 Interface RS-232&RS-485 or Optional GPIB / LAN Interface Model 1. Remote Voltage Programming (16 bit) Resolution (0.012% of Vo Rated) Accuracy (0.1% of Vo Rated) V 8 10 16 20 30 40 60 80 100 150 300 600 mV mV 0.96 8 1.2 10 1.92 15 2.4 20 3.6 30 4.8 40 7.2 60 9.6 80 12 100 18 150 36 300 72 600 2. Remote Current Programming (16 bit) Resolution (0.012% of Io Rated) Accuracy (0.3% of Io Rated+0.1% of Io Actual Output)(*13) mA mA 72 2400 60 2000 37.2 1240 30 1000 20.4 680 15 500 10.2 340 7.8 260 6.0 200 4.08 136 2.04 68 1.02 34 3. Readback Voltage Resolution (0.012% of Vo Rated) Accuracy (0.15% of Vo Rated) mV mV 0.96 12 1.2 15 1.92 24 2.40 30 3.60 45 4.80 60 7.2 90 9.6 120 12 150 18 225 36 450 72 900 4. Readback Current Resolution (0.012% of Io Rated ) Accuracy (0.4% of Io Rated)(*13) mA mA 72 2400 60 2000 37.2 1240 30 1000 20.4 680 15 500 10.2 340 7.8 260 6.0 200 4.08 136 2.04 68 1.02 34 5. OVP/UVL Programming Resolution (0.1% of Vo Rated) Accuracy (1% of Vo Rated) mV mV 8 80 10 100 16 160 20 200 30 300 40 400 60 600 80 800 100 1000 150 1500 300 3000 600 6000 *1: Minimum voltage is guaranteed to maximum 0.2% of rated output voltage. *2: Minimum current is guaranteed to maximum 0.4% of rated output current. *3: For cases where conformance to various safety standards (UL, IEC, etc) is required, to be described as 190-240Vac (50/60Hz) for 3-Phase 208V models, and 380~415Vac (50/60Hz) for 3-Phase 400V models. *4: 3-Phase 208V models: At 208Vac input voltage, 3-Phase 400V: At 380Vac input voltage. With rated output power. *5: Not including EMI filter inrush current, less than 0.2mSec. *6: 3-Phase 208V models: 170~265Vac, constant load. 3-Phase 400V models: 342~460Vac, constant load. 3|GenesysTM 5kW-2U *7: From No-Load to Full-Load, constant input voltage. Maximum drop in Remote Sense. *8: For 8V~300V models: Measured with JEITA RC-9131A (1:1) probe. For 600V model: Measured with 10:1 probe. *9: From 10% to 90% or 90% to 10% of Rated Output Voltage, with rated, resistive load. *10:From 90% to 10% of Rated Output Voltage. *11: For load voltage change, equal to the unit voltage rating, constant input voltage. *12: For 8V~16V models the ripple is measured from 2V to rated output voltage and rated output current. For other models, the ripple is measured at 10~100% of rated output voltage and rated output current. *13: The Constant Current programming readback and monitoring accuracy does not include the warm-up and Load regulation thermal drift. General Specifications GenesysTM 5kW 2.1 INPUT CHARACTERISTICS 1. Input voltage/freq. (*3) GEN VAC 2. MaximumInput currentat 100% load 3-Phase, 170V models: 3-Phase, 342V models: (A) 3. Power Factor (Typ) 4. INRUSH PEAK CURRENT 5. EFFICIENCY AT 200V AND 380V (A) 6. EFFICIENCY AT 170V AND 342V (A) 7. HOLD UP TIME (CV MODE) A % % mS % 8. PHASE IMBALANCE 9. LEAKAGE CURRENT 2.2 POWER SUPPLY CONFIGURATION 1. Parallel Operation 2. Series Operation 2.3 ENVIRONMENTAL CONDITIONS 1. Operating temp 2. Storage temp 3. Operating humidity 4. Storage humidity 5. Vibration 6. Shock 7. Altitude 8. RoHS Compliance 8-600 10-500 16-310 20-250 30-170 40-125 60-85 3-Phase 200Vac , 208Vac and 230Vac Models : 170~265Vrms , 47~63Hz 3-Phase, 400V models: 342~460Vac, 47~63Hz 80-65 100-50 150-34 21 22 22 22 22 22 22 22 22 22 10.5 11 11 11 11 11 11 11 11 11 0.94 AT 100% LOAD AND 208V/380V/400V/415V 3-Phase 200V: 50A, 3-Phase 400V: 20A. Not including the EMI filter inrush current, less than 0.2mSec. 83 84 84 86 86 88 90 88 88 88 83 84 84 86 86 88 90 88 88 88 5mS Typical 5% LESS THAN 3mA 300-17 600-8.5 22 11 22 11 88 88 88 88 Up to 4 identical units in master/slave mode Up to 2 identical units. with external diodes. 600V Max to Chassis ground 0~50C, 100% load. -20~85C 20~90% RH (non-condensing). 10~95% RH (non-condensing). MIL-810F, method 514.5 , The EUT is fixed to the vibrating surface. Less than 20G , half sine , 11mSec. Unit is unpacked. Operating: 10000ft (3000m), Derate output current by 2%/100m above 2000m, Non operating: 40000ft (12000m). Complies with the requirements of RoHS directive. 2.4 EMC 1.Applicable Standards: 2.ESD 3.Fast transients 4.Surge immunity 5.Conducted immunity 6.Radiated immunity 7.Magnetic field immunity 8.Voltage dips 9.Conducted emission 10. Radiated emission IEC1000-4-2. Air-disch.-8KV, contact disch.-4KV IEC1000-4-4. 2KV IEC1000-4-5. 1KV line to line, 2KV line to ground IEC1000-4-6, 3V IEC1000-4-3, 3V/m EN61000-4-8, 1A/m EN61000-4-11 EN55022A, FCC part 15-A, VCCI-A. EN55022A, FCC part 15-A, VCCI-A. 2.5 SAFETY 1.Applicable standards: CE Mark, UL60950,EN60950 listed. Vout40V:Output is SELV , IEEE/Isolated analog are SELV. 40