Genesys™ 5kW-2U
3|
*1: Minimum voltage is guaranteed to maximum 0.2% of rated output voltage.
*2: Minimum current is guaranteed to maximum 0.4% of rated output current.
*3: For cases where conformance to various safety standards (UL, IEC, etc›) is required, to be
described as 190-240Vac (50/60Hz) for 3-Phase 208V models,
and 380~415Vac (50/60Hz) for 3-Phase 400V models.
*4: 3-Phase 208V models: At 208Vac input voltage, 3-Phase 400V:
At 380Vac input voltage. With rated output power.
*5: Not including EMI filter inrush current, less than 0.2mSec.
*6: 3-Phase 208V models: 170~265Vac, constant load. 3-Phase 400V
models: 342~460Vac, constant load.
*7: From No-Load to Full-Load, constant input voltage. Maximum drop in Remote Sense.
*8: For 8V~300V models: Measured with JEITA RC-9131A (1:1) probe. For 600V model: Measured
with 10:1 probe.
*9: From 10% to 90% or 90% to 10% of Rated Output Voltage, with rated, resistive load.
*10:From 90% to 10% of Rated Output Voltage.
*11:For load voltage change, equal to the unit voltage rating, constant input voltage.
*12:For 8V~16V models the ripple is measured from 2V to rated output voltage and rated output
current. For other models, the ripple is measured at 10~100% of rated output voltage and rated
output current.
*13: The Constant Current programming readback and monitoring accuracy does not include the
warm-up and Load regulation thermal drift.
Genesys ™ 5kW Specifications
1.2 CONSTANT CURRENT MODE
1.Max.line regulation (0.05% of Io rated)(*6)
2.Max.load regulation (0.1% of Io rated)(*11)
3.Ripple r.m.s 5Hz~1MHz. (*12)
4.Temp. coefficient
8V
~
16V models: Less than ±0.5% of rated output current over 30 minutes following power On.
1.3 PROTECTIVE FUNCTIONS
1. OCP
2. OCP Foldback
3. OVP type
4. OVP trip point
6. Over Temp. Protection
0~105% Constant Current
Output shut down when power supply change from CV to CC. User selectable.
Inverter shut-down, manual reset by AC input recycle or by OUT button or by communication port command.
User selectable , latched or non-latched.
5~88.2V 5~110.25V
5~165.3V 5~330.7V 5~661.5V
3.Rated Output Power
1.0 MODEL
1.Rated output voltage(*1)
2.Rated Output Current(*2)
2.Display
3.Indications
Voltage: 4 digits , Accuracy: 0.5% of rated output Voltage ±1 count.
Current: 4 digits, Accuracy: 0.5% of rated output current ±1 count.
Voltage, Current, Alarm, Fine, Preview, Foldback, Local, Output On, Front Panel Lock, CV/CC.
1.5 FRONT PANEL
1.Control functions Vout/ Iout manual adjust by separate encoders (coarse and fine adjustment selectable).
OVP/UVL manual adjust by Volt. Adjust encoder.
Address selection by Voltage (or current) adjust encoder. Number of addresses:31.
On/Off, Output on/off, Re-start modes (auto, safe), Foldback control (CV to CC), Go to local control.
Re-start modes (automatic restart, safe mode).
Baud rate selection: 1200,2400,4800,9600 and 19,200.
5. OVP/UVL Programming
Resolution (0.1% of Vo Rated)
Accuracy (1% of Vo Rated)
4. Readback Current
Resolution (0.012% of Io Rated )
Accuracy (0.4% of Io Rated)(*13)
3. Readback Voltage
Resolution (0.012% of Vo Rated)
Accuracy (0.15% of Vo Rated)
2. Remote Current Programming (16 bit)
Resolution (0.012% of Io Rated)
Accuracy (0.3% of Io Rated+0.1% of Io Actual Output)(*13)
1.6 Interface RS-232&RS-485 or Optional GPIB / LAN Interface
Model
1. Remote Voltage Programming (16 bit)
Resolution (0.012% of Vo Rated)
Accuracy (0.1% of Vo Rated)
1.4 ANALOG PROGRAMMING AND MONITORING
1.Vout Voltage Programming
2.Iout Voltage Programming (*13)
3.Vout Resistor Programming
4.Iout Resistor Programming (*13)
5.On/Off control (rear panel)
6.Output Current monitor (*13)
7.Output Voltage monitor
8.Power Supply OK signal
9. CV/CC Indicator
10. Enable/Disable
0~100%, 0~5V or 0~10V, user select. Accuracy and linearity:±0.5% of rated Vout.
0~100%, 0~5V or 0~10V, user select. Accuracy and linearity:±1% of rated Iout.
0~100%, 0~5/10Kohm full scale,user select.,Accuracy and linearity: ±1% of rated Vout.
0~100%, 0~5/10Kohm full scale,user select. Accuracy and linearity:±1.5% of rated Iout.
By electrical. Voltage: 0~0.6V/2~15V,or dry contact ,user selectable logic.
0~5V or 0~10V , Accuracy:±1% , user selectable.
0~5V or 0~10V ,Accuracy:±1% ,user selectable.
TTL high (4~5V) -OK, 0V-Fail 500ohm series resistance.
Dry contact. Open:off , Short: on. Max. voltage at Enable/Disable in: 6V.
11. Local/Remote analog control
12. Local/Remote analog control Indicator
Open collector, CC mode: On, CV mode: Off, Maximum voltage: 30V, maximum sink current: 10mA
Open collector, Local: Off, Remote: On. Maximum voltage: 30V, maximum sink current: 10mA.
1.Max.line regulation (0.01% of rated Vo)(*6)
2.Max load regulation (0.015% of rated Vo+5mV)(*7)
3.Ripple and noise p-p 20MHz (*8)
4.Ripple r.m.s 5Hz~1MHz
5.Remote sense compensation/wire
8.Warm-up drift
9.Up-prog. response time, 0~Vo Rated (*9)
10.Down-prog response time No-load (*10)
11.Transient response time
100PPM/°C of rated output voltage,following 30 minutes warm-up
30mS
Time for output voltage to recover within 0.5% of its rated output for a load change 10-90% of rated output
current. Output set-point: 10-100%, local sense.
Less than 1mSec for models up to and including 100V. 2msec for models above 100V
80 200
100
100
7.Temp. stability
6.Temp. coefficient
Full-load (*9)
0.05% of rated Vout over 8hrs interval following 30 minutes warm-up. Constant line, load & temp.
Less than 0.05% of rated output voltage+2mV over 30 minutes following power On.
5.Temp. stability
6.Warm-up drift
100PPM/ºC from rated output current, following 30 minutes warm-up.
0.05% of rated Iout over 8hrs. interval following 30minutes warm-up. Constant line, load & temperature.
5. Output Under Voltage Limit Preset by front panel or communication port. Prevents from adjusting Vout below limit.
GEN 8-600 10-500 16-310 20-250 30-170 40-125 600-8.5300-17150-34100-5080-6560-85
4.25
8.5
15
600
60
95
500
120
5
3000
72
34
900
1.02
34
600
72
600
600
6000
1.02
8.5
17
30
300
30
50
300
35
5
2500
36
68
450
2.04
68
300
36
300
300
3000
2.04
17
34
90
150
15
27.5
120
25
5
2000
18
136
225
4.08
136
150
18
150
150
1500
4.08
25
50
100
100
10
20
100
15
5
1500
12
200
150
6.0
200
100
12
100
100
1000
6.0
32.5
65
120
80
8
17
85
12
5
1200
9.6
260
120
7.8
260
80
9.6
80
80
800
7.8
42.5
58
150
5~66.15V
60
6
14
75
10
5
1000
7.2
340
90
10.2
340
60
7.2
60
60
600
10.2
2~44.1V
62.5
125
300
40
4
11
75
10
5
900
4.80
500
60
15
500
40
4.8
40
40
400
15
2~36V
85
170
460
30
3
9.5
75
10
5
800
3.60
680
45
20.4
680
30
3.6
30
30
300
20.4
1~24V
125
250
1000
20
2
8
75
10
2
700
2.40
1000
30
30
1000
20
2.4
20
20
200
30
1~19V
155
310
1400
16
1.6
7.4
75
10
2
50
600
1.92
1240
24
37.2
1240
16
1.92
15
16
160
37.2
0.5~12V
250
500
1800
10
1.0
6.5
75
10
2
500
1.2
2000
15
60
2000
10
1.2
10
10
100
60
0.5~10V
300
600
1950
8
0.8
6.2
75
10
2
15
400
0.96
2400
12
72
2400
0.96
8
8
80
72
mA
mA
mA
V
A
W
mV
mV
mA
mA
mV
mV
mA
mA
V
mV
mV
mV
mV
mV
mV
V
PPM/°C
mS
mS
mS
mS
PPM/°C
50mS
1.1 CONSTANT VOLTAGE MODE
20V
~
600V models: Less than ±0.25% of rated output current over 30 minutes following power On.
8
8.5
5100
A
17
5100
B
34
5100
A
50
5000
C
65
5200
C
85
5100
A
125
5000
B
170
5100
B
250
5000
C
310
4960
B
500
5000
C
600
4800
A
4.Development Priority ---
By electrical signal or Open/Short: 0~0.6V or short: Remote, 2~15V or open: Local.