http://www.tracopower.com
Input Specifications
No load input current – positive output circuit TSRN 1-0525SM: 6 mA typ.
TSRN 1-2433SM: 1.5 mA typ.
other models: 4 mA typ.
– negative output circuit -3.3 / -5.5 Vout models: 3 mA typ.
-9.0 / -12 Vout models: 7 mA typ.
TSRN 1-24150SM: 10 mA typ.
Reflected ripple current 100 mA typ.
Input filter internal capacitors
Output Specifications
Voltage set accuracy ±2 % (at full load)
Regulation – Input variation 0.2 %
– Load variation 0 – 100 % 0.6 %
– Load variation 10 – 90 % 0.3 %
Startup voltage overshoot 1.0 % max.
Minimum load not required
Ripple and noise – |Vout| = 1.2V – 8V 50 mVpk-pk max.
(20 MHz Bandwidth) – |Vout| = 8.1V – 15V 75 mVpk-pk max.
Temperature coefficient ±0.015 % / °C max.
Dynamic load response (change of 50% to 100% load) 150 mV max. peak variation
250 µS max. response time
Startup time – start up time at nominal Vin, constant resistive load 5 mS typ.
Short circuit protection continuous, automatic recovery
Current limitation TSRN 1-0525SM: at 4.0 A typ.
other models: at 2.0 A typ.
Capacitive load 470 µF max.
General Specifications
Temperature ranges – Operating –40°C to +85°C
– case temperature +130°C. max.
– Storage –55°C to +125°C
Derating – positive output circuit 1.7 %/K above +55°C
– negative output circiut 2.5 %/K above +65°C
Thermal shock, mechanical shock & vibration EN 61373, MIL-STD-810F
– Test conditions www.tracopower.com/products/mil810.pdf
Overtemperature protection at +170°C (on internal IC)
Humidity (non condensing) 90 % rel H max.
Reliability, calculated MTBF (MIL-HDBK-217F, at +25°C, ground benign) >4´500’000 h
Isolation voltage none
Switching frequency TSRN 1-0525SM: 410 kHz typ.
TSRN 1-2433SM: 300 kHz typ.
other models: 580 kHz typ.
Safety standards (designed to meet) UL/cUL 60950-1, IEC/EN 60950-1
Remote On/Off – Control pin referance for positive output circuit GND
– Control pin referance for negative output circuit -Vout
– On: 2 – 5 VDC or open circuit.
– Off: 0 – 0.8 VDC or short circuit
– Off idle current: 1.2 mA typ.
Environmental compliance – Reach www.tracopower.com/products/tsrn1sm-reach.pdf
– RoHS RoHS directive 2011/65/EU
DC/DC Converters
TSRN-1SM Series 1 A
All specifications valid at nominal input voltage, full load and +25°C after warm-up time unless otherwise stated.