3 Watt
Single
Output
●30mW max of No Load Power Consumption
●High efficiency up to 80%
●Isolated Output 3kVAC / 1 min
●Short Circuit Protection
●Overvoltage Protection
●Meets EN55022 and FCC Class B
●Built-In Fusible Resistor
Features
Regulated
Converters
Selection Guide
Part Output Max. Total Ripple & Max.
Number Voltage Current Regulation (3) Noise (4) Efficiency Capacitive
(VDC) (lo, max) (Typ.) Load (1+2)
RAC03-3.3SC/277 3.3 900mA ±6% 200mV 71% 47000µF
RAC03-05SC/277 5 600mA ±6% 150mV 76% 15000µF
RAC03-12SC/277 12 250mA ±6% 150mV 78% 2200µF
RAC03-24SC/277 24 125mA ±6% 150mV 80% 390µF
Input Voltage Range (with Derating) 80-305VAC or 110-430VDC
Input Frequency 47-440Hz
Input Current (full Load) 115VAC/230VAC 70mA / 45mA typ.
Inrush Current 115VAC/230VAC 15A/30A max.
No Load Power Consumption 80-305VAC / 47-440Hz 30mW max.
Output Voltage (Vout nom.) 3.3V-24V
Output Voltage Tolerance ±6% max.
Minimum Load 2%
Line Voltage Regulation LL-HL at full Load ±1% typ. / ±1.5% max.
Load Voltage Regulation 2-100% Load see Selection Guide
Hold-up Time 115VAC 15ms typ.
230VAC 80ms typ.
Overcurrent Limit 116% - 156%
Switching Frequency at full Load 45kHz typ.
Isolation Voltage Input-Output 3kVAC / 1 minute
Leakage Current 80-305VAC / 47-440Hz 10uA max.
Isolation Resistance 1G Ωmin
Short Circuit Protection Continuous, Auto Restart
Over-Voltage Protection Zener clamp, set at 4.4V-5.0V for 3.3V and others
112-140% of its nominal output voltage
Over Voltage Category OVC II
Operating Temperature (5) natural convection, without derating -25°C to +75°C
natural air convection, with derating -25°C to +85°C
Storage Temperature -40°C to +85°C
Case Material UL94V-0 black plastic
Potting Material Silicon
Relative Humidity 95% RH max.
Package Weight 28g
Package Quantity 12 pcs
MTBF TA = 25°C > 1000x10³ hours
(using MIL-HDBK217F)
TA = 75°C > 100x10³ hours
Physical Dimension (LxWxH) 38.25 x 24.35 x 17.40 mm
EMI EN55022, Class B
Noise Immunity Report: T120816N04-E EN55024
Safety Standard
EC/EN General Safety Report: SPCLVD1208051 IEC/EN-60950-1
UL General Safety Report: E224736-A17-UL UL-60950-1
continued on next page
Specifications (measured at TA 25°C, full load after warm-up)
POWERLINE
AC/DC-Converter
with 3 year Warranty
EN-60950-1 Certified
UL-60950-1 Certified
RAC03-SC/277