Detailed Specifications & Technical Data METRIC MEASUREMENT VERSION 83318E Multi-Conductor - MIL-W-16878/4 (Type E), 2 Conductors Cabled For more Information please call 1-800-Belden1 General Description: 24 AWG stranded (19x36) silver-plated copper conductors, cabled and color-coded, extruded TFE Teflon(R) insulation, silver-plated copper braid shield (85% coverage), TFE teflon tape-wrapped jacket. Physical Characteristics (Overall) Conductor AWG: # Conductors AWG Stranding Conductor Material 2 24 19x36 SPC - Silver Plated Copper Total Number of Conductors: 2 Insulation Insulation Material: Insulation Trade Name Insulation Material Teflon(R) Wall Thickness (mm) TFE - Tetrafluoroethylene 0.254 Insulation Resistance: 100,000 Megaohms/1000 ft. @ 500 V DC Outer Shield Outer Shield Material: Type Outer Shield Material Coverage (%) Braid SPC - Silver Plated Copper 85 Outer Jacket Outer Jacket Material: Outer Jacket Trade Name Outer Jacket Material Teflon(R) Nom. Wall Thickness (mm) TFE - Tetrafluoroethylene 0.2794 Overall Cable Overall Cabling Color Code Chart: Number Color 1 White 2 Black Overall Nominal Diameter: 3.327 mm Mechanical Characteristics (Overall) Operating Temperature Range: -65C To +200C Bulk Cable Weight: 20.835 Kg/Km Max. Recommended Pulling Tension: 140.563 N Min. Bend Radius/Minor Axis: 38.100 mm Applicable Specifications and Agency Compliance (Overall) Applicable Standards & Environmental Programs EU Directive 2011/65/EU (ROHS II): Yes EU CE Mark: Yes EU Directive 2000/53/EC (ELV): Yes EU Directive 2002/95/EC (RoHS): Yes Page 1 of 3 04-23-2014 Detailed Specifications & Technical Data METRIC MEASUREMENT VERSION 83318E Multi-Conductor - MIL-W-16878/4 (Type E), 2 Conductors Cabled EU RoHS Compliance Date (mm/dd/yyyy): 01/01/2005 EU Directive 2002/96/EC (WEEE): Yes EU Directive 2003/11/EC (BFR): Yes CA Prop 65 (CJ for Wire & Cable): Yes MII Order #39 (China RoHS): Yes Military Specification: MIL-W-16878/4 (Type E except stranding, insulated conductors) Other Specification: NEMA HP3 Plenum/Non-Plenum Plenum (Y/N): No Electrical Characteristics (Overall) Nom. Inductance: Inductance (H/m) 0.39372 Nom. Capacitance Conductor to Conductor: Capacitance (pF/m) 86.9465 Nom. Capacitance Cond. to Other Conductor & Shield: Capacitance (pF/m) 139.114 Nom. Conductor DC Resistance: DCR @ 20C (Ohm/km) 75.463 Nominal Outer Shield DC Resistance: DCR @ 20C (Ohm/km) 26.248 Max. Operating Voltage - UL: Voltage 600 V RMS Max. Recommended Current: Current 4 Amps per conductor @ 25C Notes (Overall) Notes: Teflon(R) is a registered trademark of E. I. duPont de Nemours and Co. used under license by Belden, Inc. Put Ups and Colors: Item # Putup Ship Weight Color Notes Item Desc 83318E 009100 30 MT 1.724 KG WHITE E 2 #24 TFE BRD TFE TAPE 83318E 0091000 305 MT 6.804 KG WHITE E 2 #24 TFE BRD TFE TAPE 83318E 009500 152 MT 3.402 KG WHITE E 2 #24 TFE BRD TFE TAPE Notes: E = MAY CONTAIN MORE THAN 1 PIECE. MINIMUM LENGTH OF ANY ONE PIECE IS 25' Revision Number: 5 Revision Date: 09-04-2012 (c) 2014 Belden, Inc All Rights Reserved. Although Belden makes every reasonable effort to ensure their accuracy at the time of this publication, information and specifications described herein are subject to error or omission and to change without notice, and the listing of such information and specifications does not ensure product availability. Belden provides the information and specifications herein on an "AS IS" basis, with no representations or warranties, whether express, statutory or implied. In no event will Belden be liable for any damages (including consequential, indirect, incidental, special, punitive, or Page 2 of 3 04-23-2014 Detailed Specifications & Technical Data METRIC MEASUREMENT VERSION 83318E Multi-Conductor - MIL-W-16878/4 (Type E), 2 Conductors Cabled exemplary damages) whatsoever, even if Belden has been advised of the possibility of such damages, whether in an action under contract, negligence or any other theory, arising out of or in connection with the use, or inability to use, the information or specifications described herein. All sales of Belden products are subject to Belden's standard terms and conditions of sale. Belden believes this product to be in compliance with EU RoHS (Directive 2002/95/EC, 27-Jan-2003). Material manufactured prior to the compliance date may be in stock at Belden facilities and in our Distributor's inventory. The information provided in this Product Disclosure, and the identification of materials listed as reportable or restricted within the Product Disclosure, is correct to the best of Belden's knowledge, information, and belief at the date of its publication. The information provided in this Product Disclosure is designed only as a general guide for the safe handling, storage, and any other operation of the product itself or the one that it becomes a part of. This Product Disclosure is not to be considered a warranty or quality specification. Regulatory information is for guidance purposes only. Product users are responsible for determining the applicability of legislation and regulations based on their individual usage of the product. Belden declares this product to be in compliance with EU LVD (Low Voltage Directive 73/23/EEC), as amended by directive 93/68/EEC. Page 3 of 3 04-23-2014