pulseelectronics.com
SMT Gate Drive Transformers
>1500VDC Basic and Functional Insulation
SPM2007 (04/14)
>1500VDC isolation between Gate and Drive
Basic insulation (1.4mm creepage/
clearance) and functional available
Operating frequency: 50kHz and up
Electrical Specifications @ 25°C - Operating Temperature -40°C to +130°C
Part
Number
Turns
Ratio
Pri-Sec
Insulation
MAX
V*µsec
Primary
Inductance
(µH MIN)
Leakage
Inductance
(µH MAX)
DCR
Primary
(Ω MAX)
DCR
Secondary
(Ω MAX)
Package Size
(L x W x H)
(mm MAX)
PE-68386NL 1:1 1500 Vdc 9.7 785 0.46 0.60 0.60 8.6 x 6.7 x 2.5
P0926NL 1:1:1 1500 Vdc 23.8 300 0.50 2.00 2.00 8.0 x 6.6 x 5.3
P0544NL 1:1:1 1500 Vdc 45.1 3300 0.80 1.25 1.25 9.0 x 8.6 x 7.6
PA0264NL 1:1:1 1000 Vrms 12.7 1140 0.65 0.75 0.75 8.6 x 6.7 x 3.6
PA1323NL 1:1 1500 Vrms 21.7 600 2.0 1.25 1.25 9.5 x 7.1 x 5.3
PA0173NL 1:1:1 1500 Vrms 17.2 980 0.75 0.62 0.88 11.8 x 8.8 x 4.0
PA0185NL 1:1 1500 Vrms 17.2 980 0.75 0.88 0.62 11.8 x 8.8 x 4.0
PA0184NL 1:1 1500 Vrms 27.2 1200 0.50 0.91 0.91 9.0 x 8.6 x 7.6
PA0297NL 2:1:1 1500 Vrms 27.2 1200 0.60 0.91 0.46 9.0 x 8.6 x 7.6
PA2777NL 1:1 1500 Vrms 9.3 335.2 0.36 0.70 0.70 7.1 x 6.1 x 5.5
PA0510NL 2.5:1:1 1500 Vrms 27.2 1200 0.68 0.91 0.380 9.0 x 8.6 x 7.6
PA3493NL 1.25:1 1650 Vrms 23 656 1.3 1.03 0.85 10.9 x 9.7 x 2.7
Notes:
1. The Maximum volt-µsec rating limits the peak flux density to 2200 Gauss when
used in a unipolar drive application. For bi-polar drive applications, a maximum
volt-sec of two times this rating is acceptable (ie: 2* (volt*µsec rating) = (voltage
applied to the primary) * dutycycle / Frequency = V * alpha / Freq_Hz = V * µsec
2. Leakage inductance is measured at primary terminals with all secondaries shorted.
3. Optional Tape & Reel packaging can be ordered by adding a “T” sux to the part
number (i.e. P0544NL becomes P0544NLT). Pulse complies to industry standard
tape and reel specification EIA481.
3,4 1
2
5
4. The “NL” sux indicates an RoHS-compliant part number. Non-NL suxed parts are not
necessarily RoHS compliant, but are electrically and mechanically equivalent to NL versions.
If a part number does not have the “NL” sux, but an RoHS compliant version is required,
please contact Pulse for availability.
5. The temperature of the component (ambient plus temperature rise) must be within the
stated operating temperature range.
Functional Insulation
113
Basic Insulation (1.4mm creepage and clearance between Primary and Secondary)